| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NX20 |
| Price Range | USD 195,000 – 260,000 (FOB) |
| Instrument Type | Atomic Force Microscope |
| Application Class | Materials Science AFM |
| XY Positional Noise | < 0.25 nm (over 80 µm scan range) |
| Z-Noise Floor | < 0.03 nm |
| Feedback Loop Bandwidth | > 9 kHz |
| Maximum Sample Diameter | 200 mm |
| XY Scan Range | 100 µm × 100 µm |
| Z Scan Range | 15 µm (extendable to 30 µm) |
| Control Software | Park SmartScan™ Automation Suite |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Parker Balston NG Series |
| Price Range | USD 1,400 – 2,800 (FOB) |
| Analyte Scope | Trace Impurity Analysis in Ultra-High-Purity Gases (He, H₂, N₂, CO₂, O₂, CH₄, H₂O, CO, etc.) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | PARNet |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Horizontal Stirred Reactor |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SBH/2 (for dual-block dry baths), SBH/3 (for triple-block and dual-zone temperature-controlled dry baths) |
| Pricing | Available upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | PbSe |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-4000 |
| Pricing | Upon Request |
| Flow Rate | 0.01–20 mL/min |
| Maximum Pressure | 0.0–6000 psi |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Baseline Drift | ≤2 × 10⁻⁴ AU/h |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC4006 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–40 mL/min |
| Maximum Pressure | 10,000 psi |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient +10 °C) to 150 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PCA |
| Price Range | USD 700 – 10,000 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-Purpose |
| Measurement Range | −1000 to +1000 mV |
| Meter Accuracy | ±0.1% of full scale |
| Meter Resolution | 1 mV |
| Titration Precision | ±1 mV |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | XDV-SDD |
| Price Range | USD 27,000 – 68,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PCE-22-LD |
| Price | Upon Request |
| Power Rating | ≤350 W |
| Input Voltage | AC 208–240 V, Single-Phase, 50/60 Hz |
| Chamber Dimensions (W×H×D) | 510 × 350 × 400 mm |
| Net Weight | 28 kg |
| Sample Stage Area | 310 × 320 mm |
| Adjustable Lamp-to-Stage Distance | 20–40 mm |
| Max. Heating Temperature | 150 °C |
| Temperature Control | 20-Step Programmable Ramp/Soak, ±1 °C Accuracy |
| UV Lamp | Dual-Wavelength Hg Lamp (185 nm & 254 nm), 55 W, 200 × 200 mm Irradiation Area, 2500 h Lifetime |
| Ozone Exhaust Port | Ø80 mm (rear-mounted) |
| Ambient Ozone Emission | <45 ppb |
| Operating Environment | Altitude ≤5500 ft |
| Measurement Principle | Mie Scattering Theory (Full-Range) |
|---|---|
| Particle Size Range | 0.1–450 µm (Lab Mode) |
| Detection Channels | 70 Main + 24 Side Array (Lab), 15 User-Configurable Channels (Online) |
| Laser Source | Semiconductor Diode, 760 nm, 5 mW, >20,000 h Lifetime |
| Sample Flow Rate | 70 mL/min (Online) |
| Operating Temperature | 10–50 °C |
| Max Pressure | 100 psi (0.675 MPa) |
| Power Supply | 85–250 VAC, 50–60 Hz |
| Communication Interface | RS-485 |
| Compliance | ISO 13320, NIST-Traceable Calibration |
| Enclosure Materials | Teflon®, Stainless Steel, Borosilicate Glass, BUNA-N |
| Dimensions (Online Unit) | 320 × 110 × 110 mm |
| Weight (Online Unit) | 3 kg |
| Temperature Range | +100 °C to +132 °C |
|---|---|
| Temperature Uniformity | ±1.5 °C |
| Temperature Stability | ±0.5 °C |
| Humidity Range | 75–100 % RH (saturated steam) |
| Humidity Uniformity | ±3.0 % RH |
| Humidity Stability | ±1.5 % RH |
| Pressure Range (gauge) | 0–4 kg/cm² |
| Internal Chamber Pressure | 0–2.8 kg/cm² |
| Operating Pressure Band | 1.0–3.0 kg/cm² |
| Safety Pressure Capacity | 4 kg/cm² (1 atm + 3 kg/cm²) |
| Steam Circulation | Natural convection |
| Timer Range | 0–999 h |
| Pressurization Time (0 → 2.00 kg/cm²) | ~45 min |
| Heating Time (100 °C → 132 °C, no-load) | ~10 min |
| Temperature Ramp Rate | Air temperature average, not sample temperature |
| Key | Test Volume: 90 × 90 × 90 cm (W×D×H) |
|---|---|
| Net Weight | 320 kg |
| External Dimensions | 900 × 700 × 1600 mm (W×D×H) |
| Internal Chamber | Cylindrical, Ø400 mm × L600 mm (HAST-45 type) |
| Inner Liner Material | SUS316 stainless steel (3 mm thick) |
| Insulation | Rockwool + rigid polyurethane foam |
| Heating Element | Titanium steam generator tube |
| Temperature Range | 20°C ±15°C |
| Humidity Range | 75–100% RH |
| Dust Concentration Options | 100 mg/m³, 3000 mg/m³, 5000 mg/m³, 60000 mg/m³ |
| Dust Velocity | 5 m/s (for selected concentrations) |
| Cycle Timing | 0–999 sec / 0–99 hr (dual-range programmable) |
| Control System | Color touchscreen PLC with PT-100 sensors, P.I.D. saturation control, analog pressure gauge, manual fill valve with auto-refill capability |
| Compliance | GB/T 10586–1989, GB 2423.3–1993 (IEC 60068-2-3), MIL-STD-810D Method 502.2, GJB 150.9–1986, GB 2423.34–1986, MIL-STD-883C Method 1004.2 |
| Temperature Range | +100 °C to +132 °C (saturated steam temperature) |
|---|---|
| Humidity | 100% RH (saturated steam) |
| Operating Pressure | 1.5–3.2 kg/cm² (absolute pressure) |
| Time Setting Range | 000–999 hours |
| Pressure Ramp Time | ~45 minutes to reach 1.04 kg/cm² from ambient |
| Temperature Uniformity | ±0.5 °C |
| Temperature Display Resolution | 0.1 °C |
| Pressure Stability | ±0.2 kg/cm² |
| Controller | Microprocessor-based PID with PT-100 platinum RTD sensor |
| Safety Features | Interlocked door switch, mechanical safety valve, ABS thermal-insulated door cover, integrated silicone gasket |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PCY-III-X |
| Price Range | USD 1,400–7,200 (FOB) |
| Temperature Range (°C) | -30 to 1700 (selectable configurations) |
| Heating Rate (°C/min) | 0.1–20 (standard setpoint: 5) |
| Temperature Accuracy (°C) | ±1 |
| Sample Diameter (mm) | 5–10 |
| Sample Length (mm) | ≤50 |
| Measurement Range | 5 mm |
| Resolution | 1 µm (optional 0.1 µm digitization) |
| Atmosphere Options | Air, Vacuum (down to 10⁻¹ mbar), Static/Dynamic Inert (N₂, Ar), Reactive Gas (customizable) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PCY-SP |
| Pricing | Available Upon Request |
| Max Operating Temperature | 1000 °C (1200 °C Furnace Limit) |
| Temperature Control | Dual K-Type Thermocouples (Control + Sample Sensing) |
| Control System | Intelligent PID with Programmable Ramp Rates & Segmented Profiles |
| Temperature Accuracy | ±1 °C |
| Heating Element | Ni–Cr (2080) Resistance Wire (Theoretical Max: 1350 °C) |
| Displacement Detection | Optical Grating-Based Linear Encoder |
| Displacement Accuracy | ±0.5% FS |
| Data Acquisition | Real-Time PC-Based System |
| Software Platform | Windows 7/XP Compatible (Bilingual UI), ASTM C338–Compliant Workflow & Reporting Engine |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Pd-300 |
| Pricing | Upon Request |
| Feed H₂ Purity | >99% |
| Ultra-High-Purity H₂ Output | >99.99999% |
| Feed Gas Pressure Range | 0–1 MPa |
| Purified H₂ Delivery Pressure | 0–0.6 MPa |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Power Consumption | 250 W |
| Operating Temperature | 350 °C |
| Ambient Operating Temperature | 1–40 °C |
| Ambient Relative Humidity | <85% RH |
| Dimensions (W×D×H) | 340 × 200 × 360 mm |
| Net Weight | ~6 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | PDO-1000 |
| Price Range | USD 0.14–714 (based on ¥1–4999) |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching |
| Measurement Range | 0.00–80.00 mg/L |
| Accuracy | ±0.2 mg/L |
| Repeatability | 0.05% RSD |
| Detection Limit | ±2 ppb |
| Resolution | 0.01 mg/L / 0.01% air saturation / 0.1 °C |
| Response Time | <30 s |
| Temperature Range | 0–50 °C |
| Calibration | Factory-pre-calibrated, optional field calibration |
| Data Storage | 4 MB Flash memory (≥500 data sets) |
| Interface | USB 2.0 |
| Power | Rechargeable battery (≈1000 min operation per charge) |
| Sensor Material | Stainless steel |
| Cable Length | 8 m |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PDTM Series Desktop Vibration Isolation Platform |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PEA |
| Price Range | USD 14,000 – 70,000 |
| Dosing Capacity | Not Applicable (Integrated VHP Generation) |
| Airflow Rate | 40–95 m³/h (Customizable) |
| Sterilization Chamber Volume | External Application (No Fixed Chamber) |
| Vaporization Temperature | Not Specified (Catalytic Vaporization at Ambient-to-Moderate Temperatures) |
| Dehumidification RH Control | Dual-Stage Condensation System |
| Filtration Efficiency | HEPA H14 Integrated in Recirculation Path |
| Sterilant | Aqueous Hydrogen Peroxide (30–35% w/w) |
| Log Reduction | ≥6 log₁₀ for Geobacillus stearothermophilus and Bacillus atrophaeus (Validated per ISO 14644-3 & ISO/IEC 17025) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | PELCO LatticeAx 420 |
| Price Range | USD 0–15,000 |
| Maximum Scribe Speed | 500–600 mm/min |
| Application Scope | Laboratory Use |
| Positioning Accuracy | ±10 µm |
| Indentation Step Resolution | 5 µm |
| Optical Magnification | 0.58–7× (zoom, parfocal, monocular) |
| Camera | Color CCD |
| Diamond Scribing Tip | Polished Single-Point Diamond |
| Focusing Mechanism | Coarse + Fine Focus Stage |
| Footprint | Compact Industrial Platform |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 600-SA |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YIQI037 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Peregrine 486 |
| Pricing | Available Upon Request |
| CCD Format | 4096 × 4096 pixels |
| Pixel Size | 15 µm × 15 µm |
| Illumination Type | Front- or Back-Illuminated |
| Readout Ports | 4 |
| Readout Speeds | 250 kHz and 1 MHz per port |
| Readout Noise | <7 e⁻ at 1 MHz |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PeriIont Iontophoresis System |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 200 |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months limited parts and labor |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 210VGP |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | 0.1 nm |
| Sensitivity | Cu 5 ppm, Absorbance > 0.3 A |
| Repeatability (RSD) | < 0.3% |
| Detection Limit | Cu ≤ 0.005 mg/L |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±0.1 nm |
| Slit Widths | 0.2 / 0.7 / 2.0 nm |
| Background Correction | Deuterium Lamp (190–350 nm) and Self-Reversal HCL (190–900 nm) |
| Atomization | Air/Acetylene, N₂O/Acetylene, Ar/H₂ premixed flame |
| Furnace Max Temp | 3000 °C in <1 s |
| Data Interface | RS-232C, IEEE-488 (GPIB), Parallel Printer Port |
| Dimensions (L×W×H) | 991 × 279 × 305 mm |
| Net Weight | 23 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 411 |
| Pricing | Available Upon Request |