| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRIO.BAS DUO |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Sampling Principle | Isokinetic Impaction via Precision Laser-Drilled Stainless Steel Nozzle Array |
| Flow Rate | 200 L/min (selectable 100/200 L/min) |
| Flow Accuracy | ±2.5% of reading |
| Sampling Duration | 0–10 min (programmable in segments) |
| Operating Temperature | −10 °C to +40 °C |
| Operating Relative Humidity | 0–80 % RH |
| Sample Dish Compatibility | 60 mm and 90 mm Petri Dishes |
| Display | Backlit LCD (32 × 64 mm) |
| Control Interface | 4 Membrane Waterproof Keys |
| Wireless Connectivity | Integrated Bluetooth 5.0 |
| Power Supply | Rechargeable Ni-MH Battery (12 V, 4500 mAh) |
| Charging Input | AC 100–240 V, 50/60 Hz |
| USB Charging Port | 5 V, 500 mA |
| Weight | 1.9 kg (main unit only) |
| Dimensions | 260 × 280 × 140 mm |
| Certifications | CE (EN 61010-1:2010, EN 61326-1:2006, EN 62321:2009), ATEX II 2G Ex eb IIB T4 Gb (EN 60079-0:2012, IEC 60079-15:2010) |
| Data Integrity Compliance | FDA 21 CFR Part 11–ready audit trail & electronic signature support |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OSA-type |
| Pricing | Available Upon Request |
| Key Features | Microprocessor-controlled cryoscopic measurement |
|---|---|
| Sample volume | 30–50 µL (optional 15 µL configuration) |
| Measurement time | <60 s per sample |
| Accuracy | ±0.5% or ±2 digits (at 50 µL), ±1% or ±4 digits (at 30 µL) |
| Resolution | 1 mOsmol/kg |
| Measuring range | up to 3000 mOsmol/kg |
| Cooling system | Dual independent Peltier elements with electronic temperature regulation (±0.1 °C stability) |
| Display | 4½-digit LED |
| Dimensions | 220 W × 205 H × 360 D mm |
| Weight | 7 kg |
| Power supply | 110/230 V, 50/60 Hz |
| Compliance | Designed for GLP/GMP-aligned pharmaceutical QC environments |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | OTC-Auto |
| Price | USD 42,000 (FOB Beijing) |
| Key | Max Temp: 1200°C (<1 hr) |
|---|---|
| Temp Control Accuracy | ±1°C |
| Heating Rate | ≤20°C/min (recommended ≤10°C/min) |
| Heating Zone Length | 40 mm |
| Uniform Temp Zone | 150 mm (±1°C) |
| Tube Dimensions | OD 100 mm × ID 94 mm × L 1450 mm |
| Power | 3 kW |
| Voltage | AC 208–240 V, 1-phase, 50/60 Hz |
| Vacuum Level | ≤0.05 Torr (pump-dependent) |
| Net Weight | ~85 kg |
| External Dimensions | 660 L × 400 W × 1450 H mm |
| Heating Element | Mo-doped Fe-Cr-Al alloy with ZrO₂ coating |
| Cooling Medium Compatibility | Liquid nitrogen, ice water, or quenching oil |
| Compliance | CE, UL/MET/CSA (for components >24 V), optional TÜV or CSA single-unit certification |
| Max Temp | 1100°C |
|---|---|
| Max Pressure | 20 MPa |
| Heating Zone | 250 mm |
| Tube Dimensions | 55 mm O.D. × 20 mm I.D. × 550 mm L |
| Power | 2.5 kW |
| Voltage | AC 208–240 V, 50/60 Hz |
| Temp Uniformity | ±1°C (50 mm), ±2°C (70 mm) |
| Control | 30-Stage PID with Thermocouple Break Protection |
| Pressure Monitoring | Integrated Front-Panel Digital Gauge with Adjustable High/Low Alarm |
| Cooling | Dual-layer Air-Cooled Shell + Aluminum Heat Sink |
| Insulation | High-Purity Al₂O₃ Fiber + Imported High-Temp Al₂O₃ Coating |
| Seal | OFHC Copper O-Ring (CF-Style Flange) |
| Certification | CE, ZL-2011-2-0077158.0 |
| Key Features | Vibration Table Surface: 500 × 500 mm |
|---|---|
| Vibration Axis | Vertical Only |
| Max Load Capacity | 100 kg |
| Frequency Range | 1–600 Hz |
| Sweep Frequency Range | 1–600 Hz |
| Displacement Amplitude | 0–5 mm (peak-to-peak) |
| Max Acceleration | 20 g |
| Time Control Resolution | 1 second (up to 1 year duration) |
| Waveforms | Sinusoidal, Half-Sine |
| Amplifier Power Output | 2.2 kW |
| Input Voltage | 220 V ±10% AC, 50/60 Hz |
| Max Current Draw | 5 A |
| Frequency Display Resolution | 0.01 Hz |
| Vibrator Body Dimensions (H×W×D) | 500 × 500 × 160 mm |
| Chamber Integration | Integrated environmental chamber for simultaneous temperature and humidity control |
| Temperature Range | –40°C to +150°C (typical, per standard configuration) |
| Humidity Range | 10–98% RH (non-condensing, typical) |
| Compliance | Designed to support testing per MIL-STD-810H, IEC 60068-2-6, IEC 60068-2-64, GB/T 2423.10, GB/T 2423.3, ISO 16750-3 |
| Key | Temperature Range: +100°C to +132°C |
|---|---|
| Temperature Uniformity | ±1.5°C |
| Temperature Stability | ±0.5°C |
| Humidity Range | 75–100% RH (saturated steam) |
| Humidity Uniformity | ±3.0% RH |
| Humidity Stability | ±1.5% RH |
| Absolute Pressure Range | 1.0–3.0 kg/cm² |
| Safety Pressure Capacity | 4.0 kg/cm² |
| Test Duration | 0–999 hours |
| Pressurization Time (0 → 2.00 kg/cm²) | ~45 min |
| Heating Time (100°C → 132°C, no-load) | ~10 min |
| Circulation Method | Natural convection of saturated steam |
| Construction | Stainless steel chamber body, extended-shaft high-temp/low-temp resistant circulation motor, aluminum alloy multi-blade centrifugal impeller |
| Cabinet Types | Benchtop and Floor-standing configurations |
| Key | Temperature Range: 105–132 °C (control point) |
|---|---|
| Temperature Uniformity | ±2.0 °C |
| Temperature Stability | ±0.5 °C |
| Humidity Range | 75–100 % RH (control point) |
| Humidity Stability | ±2.5 % RH |
| Humidity Uniformity | ±5.0 % RH |
| Pressure Range | 0.05–0.196 MPa (0.5–2 kgf/cm²) |
| Ramp Time (Ambient → 132 °C) | ≤35 min |
| Pressure Ramp Time (Ambient → 0.196 MPa) | ≤40 min |
| PID Temperature Control Accuracy | ±0.1 °C |
| Safety Features | Dual overheat protection, mechanical safety valve, interlocked door switch, auto-water replenishment, saturated steam purification system, ABS thermal-insulated door, molded silicone door gasket |
| Key | Capacity Options: ∅250×450 mm (HAST-25) |
|---|---|
| Temperature Range | RT+10°C to 132°C |
| Humidity Range | 75–100% RH |
| Pressure Range | 0–2.8 kg/cm² (gauge), max capacity 4.0 kg/cm² |
| Temp. Uniformity | ±1.5°C |
| Temp. Control Accuracy | ±0.5°C |
| Temp. Resolution | 0.1°C |
| Pressurization Time (0→2.0 kg/cm²) | ~30 min |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Cabinet | SECC steel with electrostatic powder coating |
| Key | Temperature Range: 100–132 °C |
|---|---|
| Humidity Range | 75–100 % RH (saturated steam) |
| Pressure Range | 0–4 kg/cm² above atmospheric |
| Chamber Dimensions (ID) | Φ25×40 cm (OK-HAST-25) / Φ30×50 cm (OK-HAST-30) / Φ40×60 cm (OK-HAST-40) / Φ50×70 cm (OK-HAST-50) |
| Temperature Control Accuracy | ±0.1 °C (PID) |
| Safety Features | Dual overheat protection, interlocked door switch, pressure relief valve, ABS thermal shield, integrated silicone gasket, automatic water replenishment, unsaturated steam purge system |
| Compliance | Designed for IEC 60068-2-13, ISO 11737-1, ASTM F1980, and JIS Z 2801 accelerated aging validation protocols |
| Key | Capacity Options: ∅250×450 mm (OK-PTC-25) |
|---|---|
| Temperature Range | RT+10°C to 132°C |
| Humidity Range | 100% RH (saturated steam) |
| Pressure Range | 0–2.8 bar(g) (max. safety rating: 4.0 bar(g)) |
| Temp. Uniformity | ±1.5°C |
| Temp. Control Accuracy | ±0.5°C |
| Temp. Resolution | 0.1°C |
| Pressurization Time (0→2.0 bar) | ~30 min |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Casing | SECC steel with electrostatic powder coating |
| Compliance | ASTM D2247, IEC 60068-2-66, JIS C 0068, ISO 16750-4, MIL-STD-810H, UL 1598, NACE TM0177, DIN EN 60068-2-66 |
| Key | Chamber Internal Diameter × Depth = ∅250×450 mm (OK-PTC-25) |
|---|---|
| Temperature Range | RT+100°C to 132°C |
| Humidity | 100% RH |
| Pressure Range | 0.0–2.8 kg/cm² (gauge), max working pressure 3.0 kg/cm² (absolute), safety limit 4.0 kg/cm² |
| Temp. Uniformity | ±1.5°C |
| Temp. Control Accuracy | ±0.5°C |
| Temp. Resolution | 0.1°C |
| Pressurization Time (0 → 2.0 kg/cm²) | ~30 min |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Casing | SECC steel with electrostatic powder coating |
| Compliance | ASTM D2247, IEC 60068-2-66, ISO 11357-4, JIS C 0068, MIL-STD-810H, UL 1012, NACE TM0177, DIN 50017, BS EN 60068-2-66 |
| Key | Temperature Range: 105–132 °C (control point) |
|---|---|
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Control Point | 100 % RH |
| Humidity Stability | ±2.5 % RH |
| Humidity Uniformity | ±5.0 % RH |
| Pressure Range | 0.05–0.196 MPa (0.5–2 kgf/cm²) |
| Ramp Time (Ambient to 132 °C) | ≤35 min |
| Pressure Ramp Time (Ambient to 0.196 MPa) | ≤40 min |
| Auto-refill Function | Yes |
| Safety Interlocks | Door latch, overpressure relief, dual overtemperature cutoff, steam quality management via condensate purge |
| Key | Temperature Range: –40 °C to +150 °C (optional down to –120 °C) |
|---|---|
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 color LCD touchscreen controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (customizable to 220 V) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or A3 steel with electrostatic powder coating |
| Compliance | GB/T 5170.2–1996, GB/T 5170.5–1996, GB 2423.1–1989, GB 2423.2–1989, GB 2423.22–1987, GB 10589–1989, GB 10592–1989, GB 11158–1989 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OV2001 / OV2000 |
| Temperature Control | Active Cooling & Heating |
| Safety Features | Over-Temperature Protection |
| Capacity | Accommodates 3–4 Standard HPLC/GC Columns |
| Control Algorithm | Dual-Mode Fuzzy Logic + PID Auto-Tuning |
| Uniformity | ±0.3 °C across column center zone |
| Monitoring | Real-Time Internal Temperature Tracking |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BFOG |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | COBRA |
| Quotation | Upon Request |
| Tank Capacity | 0.5 L |
| Unit Weight | 350 g (empty), 750 g (filled) |
| Dimensions (H × Ø) | 25 cm × 7.3 cm |
| Hose Length | 100 cm |
| Materials | Stainless Steel, Chemically Resistant Plastic & Elastomeric Components |
| Accessories | Shoulder Strap, Cleaning Brush, Filling Funnel |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SMGD |
| Quotation | Upon Request |
| Chamber Volume | N/A |
| Heating Power | N/A |
| Wash Temperature | N/A |
| Cleaning Agent Type | Compatible with dry, enzymatic, and ready-to-use decontaminants |
| External Dimensions (L×W×D) | N/A |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Microstat |
| Price Range | USD 42,000 – 70,000 |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat CF (Gas Exchange) / Optistat CF-V (Vacuum) |
| Operating Modes | Pull Mode / Push Mode |
| Sample Temperature Range | 2.3–500 K (CF) / 4.2–500 K (CF-V) |
| Temperature Stability | ±0.1 K |
| Max Sample Chamber Dimensions | 30 mm (W) × 58 mm (L) |
| Sample Holder Dimensions | 20 mm (W) × 50 mm (L) |
| Sample Environment | Vacuum or Controlled Exchange Gas (e.g., He, N₂) |
| Sample Exchange Time | ~60 min |
| Cool-down to 4.2 K | ≤10 min |
| Liquid Helium Consumption at 4.2 K | <0.45 L/h (f/0.9 optical access) |
| Mass | 2 kg |
| Optional Upgrades | 500 K High-Temperature Stage |
| Optical Window Materials | Fused Silica, IR-Grade Quartz, Sapphire, CaF₂, Polyethylene |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat Dry |
| Price Range | USD 42,000 – 70,000 |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat |
| Price Range | USD 42,000 – 70,000 |
| Temperature Range | 77.2–500 K (standard), up to 500 K with sapphire window option |
| Temperature Stability | ±0.1 K |
| Sample Chamber Diameter | 20 mm |
| Sample Stage Dimensions | 19 mm × 30 mm (OptistatDN), 20 mm × 50 mm (OptistatDN-V) |
| Sample Environment | Exchange gas or high vacuum |
| Sample Exchange Time | 5 min (exchange gas), 60 min (vacuum) |
| Cool-down to 77 K | ≤20 min |
| Liquid Nitrogen Capacity | 1.2 L |
| Hold Time at 77 K | ≥15 h |
| Optical Access | f/1 clear aperture |
| Weight | 5 kg |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Oxidograph |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Monitor-Compatible Oximetry Sensor |
| Pricing | Upon Request |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | Plastic Oxygen Index Tester |
| Price | USD 145 (approx.) |
| Gas Flow Total | 10.6 L/min |
| O₂ Concentration Range | 0–100% |
| Resolution | 0.1% |
| Accuracy | ±0.1% |
| Response Time | <3 s |
| O₂ Adjustment Step | 0.2% (v/v) |
| Sensor Type | External Electrochemical O₂ Sensor |
| Display | Digital Concentration Meter (O₂%, N₂ flow, total flow) |
| Standards Compliance | GB/T 2406, GB/T 10707, GB/T 5454, ASTM D2863, ISO 4589-2, BS 2782-1:141, NF T51-071 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Measurement Principle | Metal Oxide Semiconductor (MOS) Sensor |
| Detection Range | 0.000–50.00 ppm (multi-range selectable) |
| Accuracy | ±0.005 ppm (0–0.100 ppm), ±10% (0.100–2.00 ppm), ±15% (2.00–20.00 ppm), ±20% (20.00–50.00 ppm) |
| Resolution | 1 ppb (low-range), 0.01 ppm (mid/high-range) |
| T90 Response Time | <10 s (leak range) to <70 s (ultra-low range) |
| Operating Temp | −5°C to +50°C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Power | 12 VDC, 800 mA |
| Rechargeable Options | 9.4 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Enclosure Rating | IP20 / NEMA 1 |
| Dimensions | 195 × 122 × 54 mm (with probe) |
| Weight | <460 g (with probe and battery) |
| Compliance | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Key Features | Stainless steel sealed test chamber |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C |
| Humidity range | 30–65 %RH |
| Temp. uniformity | ±0.5 °C |
| Sample rotation | 360°, 1 rpm |
| Gas flow velocity | 8–16 mm/s |
| Compliance with GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1 | 2004 |