Generic
Filter
Showing 3481–3510 of 5744 results
| Key Features | Stainless steel test chamber |
|---|---|
| ASTM D1149 / ISO 1431-1 | 2004 / GB/T 7762–2003 compliant design |
| Gas flow velocity | 8–16 mm/s |
| Key Specifications | Temperature Range: 25–40 °C |
|---|---|
| Humidity Range | 30–65 %RH |
| Ozone Concentration | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rotation Speed | 1 rpm (360° continuous rotation) |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek color touchscreen HMI |
| Ozone Generation | Silent discharge tube type |
| Ozone Detection | Non-dispersive UV absorption sensor (≥5-year service life) |
| Compliance | ASTM D1149, ISO 1431-1, GB/T 7762, JIS K 6259 |
| Key Features | Stainless steel test chamber |
|---|---|
| Humidity control | 30–65% RH |
| Rotating sample rack | 1 rpm, 360° continuous rotation |
| Gas flow velocity | 8–16 mm/s |
| Compliant with GB/T 7762-2003, GB/T 2951.21-2008, GB/T 11206-2009, ISO 1431-1 | 2004 |
| Electrical supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Key Features | Stainless steel test chamber |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C, ±0.5 °C stability |
| Humidity range | 30–65 % RH |
| Sample rack rotation | 360°, 1 rpm |
| Gas flow velocity | 8–16 mm/s |
| Compliance with GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1 | 2004 |
| Key Features | Stainless steel ozone test chamber with fully enclosed silent-discharge ozone generation circuit |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C, fluctuation ±0.5 °C |
| Humidity range | 30–65 % RH |
| Sample rack | 360° continuous rotation at 1 rpm (static/dynamic modes optional) |
| Gas flow velocity | 8–16 mm/s |
| Control system | Weilun color touchscreen + Siemens PLC |
| Ozone sensing | Non-dispersive UV absorption analyzer (≥5 yr service life) |
| Output | 4–20 mA analog + RS232 digital interface |
| Safety | Leakage, short-circuit, overtemperature, motor overheat, and overcurrent protection |
| Power supply | AC 380 ±5 V / 50 ±0.5 Hz |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | P-5L2C |
| Price | Upon Request |
| Detection Principle | Light Scattering (Nephelometry) |
| Sensitivity | 0.01 mg/m³ |
| Measurement Range | 0.01–100 mg/m³ |
| Sampling Duration Options | 0.1, 1, 3, 5, 10, 15 min + manual mode |
| Repeatability Error | ±2% |
| Accuracy | ±10% |
| Display | 4-digit LCD showing CPM and mass concentration (mg/m³) |
| Data Output | RS232 serial interface for PC connection or dedicated thermal printer |
| Data Storage | 99 measurement records |
| Environmental Operating Temperature | 0–40 °C |
| Power Supply | NiMH ×9 rechargeable battery (12 h continuous operation) |
| Dimensions | 202 × 85 × 168 mm |
| Weight | 2.4 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | P100 |
| Price Range | USD 1,400 – 7,000 |
| Product Type | Automatic Polarimeter |
| Temperature Control | Integrated Peltier-based Thermostatic Cell Holder (±0.1 °C stability) |
| Display | Backlit LCD with Real-time Dual-Parameter Readout |
| Light Source | Stable 589.3 nm LED (Na-D Line Equivalent) |
| Optical Rotation Range | ±45° |
| Sucrose Scale Range | ±120°Z |
| Accuracy | ±(0.01° + 0.05% of reading) for optical rotation |
| Minimum Resolution | 0.01° / 0.01°Z |
| Repeatability | ≤0.002° (optical rotation), ≤0.006°Z (sucrose scale) |
| Interface | RS-232C for Data Export and Remote Control |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | P16 |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | P200 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Automatic Polarimeter |
| Temperature Control | Integrated Peltier-based Thermostatic Cell Holder |
| Digital Display | 5.6" TFT True-Color Touchscreen |
| Light Source | High-Stability LED at 589.3 nm (Na-D Line Equivalent) |
| Optical Path | Dual-Beam Balanced Detection |
| Measurement Range | Optical Rotation ±89.99°, Sucrose Concentration ±257°Z |
| Resolution | 0.001° (optical rotation) |
| Accuracy | ±0.01° (within ±45°), ±0.02° (beyond ±45°) |
| Repeatability (Std Dev) | ≤0.002° |
| Temperature Control Range | 15–40 °C (adjustable in 0.1 °C increments) |
| Temperature Stability | ±0.2 °C |
| Sample Tubes | 100 mm (ambient & thermostatted), 200 mm (ambient) |
| Minimum Transmittance | 1% |
| Data Storage | 1000 measurement records |
| Interface | USB 2.0 (host/device) |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz, 250 W |
| Net Weight | 24 kg |
| Origin | USA |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | P3 |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | P300 |
| Price Range | USD 1,400 – 7,200 |
| Product Type | Automatic Polarimeter |
| Temperature Control | Integrated Peltier |
| Digital Display | Yes |
| Light Source | High-Stability LED |
| Optical Rotation Range | ±89.99° |
| Sucrose Scale Range | ±259°Z |
| Measurement Accuracy | ±0.01° (within ±45°), ±0.02° (beyond ±45°) |
| Resolution | 0.001° |
| Repeatability (Std. Dev.) | ≤0.002° |
| Temp. Control Range | 15–35°C |
| Temp. Stability | ±0.2°C |
| Display | 5.6″ TFT True-Color Touchscreen |
| Sample Cells | 100 mm (standard & thermostatted), 200 mm (standard) |
| Minimum Transmittance | 1% |
| Calibration | Manual with Certified Quartz Controls |
| Interface | USB-B |
| Data Storage | 1,000 measurement records |
| Power | 220 V ±10%, 50 Hz ±1 Hz, 250 W |
| Net Weight | 24 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | P400 |
| Price Range | USD 1,400 – 7,000 |
| Product Type | Automatic Polarimeter |
| Temperature Control | Integrated Peltier |
| Digital Display | Yes |
| Light Source | High-Stability LED |
| Optical Rotation Range | ±89.99° |
| Sucrose Scale Range | ±259°Z |
| Measurement Accuracy | ±0.01° (within ±45°), ±0.02° (beyond ±45°) |
| Resolution | 0.001° |
| Repeatability (SD) | 0.002° |
| Temperature Range | 15–45°C |
| Temperature Stability | ±0.2°C |
| Display | 5.6″ TFT True-Color Touchscreen |
| Sample Cells | 100 mm (standard & thermostatted), 200 mm (standard) |
| Minimum Transmittance | 1% |
| Auto-Calibration | Yes |
| Interface | USB |
| Data Storage Capacity | 1,000 measurements |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz, 250 W |
| Net Weight | 24 kg |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | P5-L2C |
| Price | ¥18,600 |
| Operating Principle | Light Scattering (Nephelometric) |
| Safety Rating | Non-Explosive |
| Measurement Range | 0.01–100 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Sampling Duration Options | 0.1, 1, 3, 5, 10, 15 min or user-defined manual interval |
| Display | 4-digit LCD showing CPM and mass concentration (mg/m³) simultaneously |
| Data Output | RS-232 serial interface for PC connection |
| Data Storage | 99 measurement records |
| Environmental Operating Range | 0–40 °C |
| Power Supply | NiMH ×9 rechargeable battery (12 h continuous operation) |
| Dimensions | 202 × 84 × 183 mm |
| Weight | 3.4 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 05-STP-910 |
| Core Type | Gas Laser System |
| Wavelength | 632.8 nm |
| Output Power | 0.5 mW |
| Beam Diameter | 0.48 mm |
| Beam Divergence | 1.70 mrad |
| Polarization Ratio | >1000:1 |
| Amplitude Noise | <0.1% RMS |
| Frequency Tuning Range (Blue Side) | 400–600 MHz |
| Amplitude Tuning Range | 0.35–0.70 mW |
| Coherence Length (1 hr / 8 hr / 30 days) | >300 m / >30 m / >30 m |
| Amplitude Stability (1 hr / 8 hr / 30 days) | ±0.1% / ±0.1% / ±0.2% |
| Frequency Stability (1 hr / 8 hr / 30 days) | ±1 MHz / ±1 MHz / ±10 MHz |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | PAL-Cleaner |
| Product Type | Handheld Refractometer |
| Temperature Control | None |
| Digital Display | Yes |
| Measurement Range | 0.00–25.00% (w/w) |
| Accuracy | ±0.10% (refractive index equivalent) |
| Temperature Accuracy | ±1°C |
| Operating Temperature Range | 10–100°C |
| Dimensions | 55(W) × 31(D) × 109(H) mm |
| Weight | 100 g (body only) |
| IP Rating | IP65 |
| Resolution | 0.01% (0.00–1.99%), 0.10% (2.00–25.00%) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PES |
| Price Range | USD 140 – 1,400 (FOB) |
| Filtration Ratings | 0.1 µm, 0.22 µm, 0.45 µm, 0.65 µm |
| Filter Area | 0.60 m² |
| Bubble Point (Water) | 0.42 MPa @ 0.1 µm |
| Water Flow Rate (ΔP = 0.01 MPa, 1 cP) | ≥5 L/min @ 0.1 µm |
| Max Operating Pressure | 0.42 MPa (forward), 0.21 MPa (reverse) |
| Sterilization | Steam-in-place (SIP) at 121°C, 0.1 MPa, 30 min × 30 cycles |
| Max Temp | 65°C (standard), 95°C (high-temp grade, 0.1 MPa) |
| Housing Material | Polypropylene (PP) or PVDF |
| Core Support | Imported polyester nonwoven |
| Seal Material | Silicone or FKM (Viton®) |
| Chemical Compatibility | Broad—refer to certified compatibility chart |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S40 |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Light Obscuration (LO) |
| Particle Size Channels | 8 user-configurable thresholds |
| Compliance Standards | ISO 4406:1987, ISO 4406:1999, SAE AS4059D, NAS1638 (12-class cleanliness grading) |
| Flow Control | Integrated piston pump, capable of sampling from ambient pressure up to 420 bar system pressure |
| Display | Backlit touchscreen interface |
| Data Output | RS-232C serial interface, 8-bit ASCII protocol |
| Printer | Built-in 32-column thermal printer |
| Storage Capacity | 500 measurement records |
| Power Supply | 90–230 V AC, 50 Hz |
| Weight | ~9 kg |
| Dimensions | 300 × 140 × 300 mm |
| Viscosity Range | ≤200 cSt (unpressurized), ≤350 cSt (pressurized), ≤1000 cSt (lubricating oil systems) |
| Security | User-level password protection |
| CPU | 32-bit high-performance controller |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EPOCH LT |
| Pricing | Available Upon Request |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Panlab Drinko-Lick |
| Price | USD 13,800 (approx.) |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE116 |
| Price | USD 14,000 (approx.) |
| Sensor Sensitivity | 10 mg – 2 kg |
| Chamber Dimensions | 250 × 250 × 250 mm (W×D×H) |
| Sound Frequency Range | 200–10,000 Hz |
| Sound Intensity | Up to 120 dB SPL |
| White Noise Range | 60–120 dB SPL |
| Max Channels per PC | 8 |
| Floor Grid Options | 6 mm or 10 mm spacing |
| Construction Materials | Sandwiched acrylic, aluminum alloy, stainless steel |
| Compliance | CE Marked |
| Power Supply | 110/220 V, 50/60 Hz |
| Animal Weight Range | 15–500 g |
| Software | PACKWIN V2.0 with STARTLE and FREEZING modules |
| Optional Hardware | Pneumatic startle (LE119), electric shock generator (LE10026), environmental configuration kits (LE115), species-specific restraints (LE117 series), stimulus interface modules (LE118 / LE1188) |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | LE5001 |
| Pricing | Available Upon Request |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE870 (Rat), LE872 (Mouse) |
| Price | USD 13,500 (FOB) |
| Power Supply | 110–220 V AC, 50/60 Hz |
| Construction Materials | Acrylic (PMMA), Anodized Aluminum, Stainless Steel |
| Animal Compatibility | Mice (min. 10 g), Rats (min. 40 g) |
| Chamber Dimensions (White/Black) | Mouse — 250 × 250 × 240 mm / 195 × 108 × 120 mm |
| Stimulus Delivery | Programmable DC current pulse generator (0–2 mA, adjustable step resolution ≤ 0.01 mA) |
| Detection Method | High-precision load-cell-based weight sensing (no optical beams or tilt switches) |
| Software Control | SHUTAVOID v3.2 (supports up to 8 independent chambers via USB interface, no PCI card required) |
| Primary Output Metric | Latency-to-enter black compartment (ms resolution) |
| Application Scope | Short-term & long-term memory assessment, fear-motivated passive avoidance learning, neuropharmacological screening, hippocampal-dependent behavioral phenotyping |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Panlab LE8815 (45×45 cm, 2.5 cm beam spacing) / LE8816 (25×25 cm, 1.3 cm beam spacing) |
| Control Unit | LE8825 (supports up to 2 IR frames) |
| Data Logger Memory | 200 h |
| Communication | RS232 (with CONRS232USB adapter) |
| Software Options | SEDACOM V2.0 (instrument control & data export), ACTITRACK V2.7 (trajectory analysis across up to 32 frames) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Panlab LE902 |
| Price | USD 13,800 (FOB) |
| Sensor Resolution | Adjustable from 4 to 36 segments per full rotation |
| Bidirectional Detection | Left-rotation and right-rotation counted independently |
| Data Output | TTL-compatible digital signal |
| Software | SeDaCom V2.0 (optional, requires separate license) |
| Container Options | Bowl (Ø400 mm × H200 mm) or Cylinder (Ø400 mm × H300 mm) |
| Mounting | Adjustable soft-loop tether with low-torque swivel interface |
| Counter Unit | LE902CC76-0242 Dual-Channel Rotational Counter (L/R) or LE380676-0243 Programmable MultiCounter (up to 15 independent rotational inputs) |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE916 (Mouse), LE918 (Rat) |
| Price Range | USD 13,500 – 68,000 |
| Max Channel Capacity | 8 units |
| Stimulus Modalities | Auditory (programmable tone), Visual (LED light), Aversive (constant-current foot shock) |
| Detection Method | Dual-load-cell weight sensing (no optical or tilt-based artifacts) |
| Interface | USB 2.0, no internal PCI/PCIe card required |
| Compliance | Designed for GLP-compliant behavioral labs |
| [Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | TQY500 |
| Price | Upon Request |
| Measurement Range | 0–40,000 Coresta |
| Resolution | 0.1 Coresta |
| Accuracy | ≤ ±2% of reading |
| Repeatability | ≤ ±1% of reading |
| Test Area | 2 cm² |
| Adjustable Test Spacing | 0–999 mm |
| Max Test Count | 5,000 cycles |
| Avg. Test Time | 5 s per point |
| Air Supply | 0.5–0.7 MPa, oil-free, water-free, particle-free |
| Dimensions | 540 × 500 × 300 mm |
| Weight | 33 kg |
| Compliance | GB/T 23227, GB/T 12655, ISO 2965:2009, JJG(Tobacco) 08–2014] |
| Origin | USA |
|---|---|
| Type | Box-Type Muffle Furnace |
| Model | PMT21 |
| Max Temperature | 1287°C |
| Temperature Uniformity | ±3°C |
| Max Power | 9600 W |
| Heating Rate to Max Temp | 60 min |
| Heating Element | Kanthal A1 Resistance Wire |
| Internal Dimensions (W×D×H) | 533 × 533 × 330 mm |
| Effective Chamber Volume | 93.45 L |
| Controller | Sentry 12-Key Digital Programmable Controller |
| Voltage/Frequency/Current | 230 V / 50 Hz / 40 A |
| Net Weight | 290.3 kg |
| Insulation Thickness | 150 mm Refractory Ceramic Fiber |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | Paragon XHD |
| Price Range | USD 0–140,000 (FOB) |
| Spatial Resolution | 80–100 µm |
| Temporal Resolution | 30 fps |
| Gray Scale | 256 levels |
| Time-Gain Compensation (TGC) | 8 adjustable segments |
| Measurement Functions | Distance, Circumference, Area, Volume, Depth, Angle |
| Dynamic Range | 30–150 dB |
| Display Modes | B-mode + Color Doppler + Pulsed-Wave Doppler (B+C+PW) |
| Maximum Penetration Depth | 50 mm |