| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | China-sourced (Taiwan) |
| Model | YT-330 |
| Pricing | Available Upon Request |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | YL-1210 |
| Quotation | Available Upon Request |
| Load Capacity Options | 5 / 10 / 20 / 50 / 100 / 200 / 500 kgf |
| Force Resolution | 1/250,000 full scale |
| Force Accuracy | ≤ ±0.5% of reading |
| Displacement Resolution | 0.005 mm |
| Maximum Test Stroke | 700 mm (excluding fixtures) |
| Test Width | 420 mm |
| Speed Range | 0.5–500 mm/min |
| Force Unit Conversion | kgf, g, N, kN, lbf, ton (user-selectable) |
| Safety Stop Modes | Overload stop, specimen rupture detection, emergency stop button, upper/lower limit position stop, over-travel protection |
| Control Interface | PC-based closed-loop control system |
| Dimensions (W×D×H) | 62 × 50 × 140 cm |
| Net Weight | ~65 kg |
| Power Supply | AC 220 V, 50–60 Hz, 4 A |
| Standard Accessories | One set of universal tensile grips, dedicated test software, USB/RS232 interface cable, software installation disc |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | YL-8809A |
| Pricing | Upon Request |
| Sampling Thickness | 0.1–1.5 mm (foam tape), 0.1–0.25 mm (PET protective film), 0.1–0.6 mm (fabric tape) |
| Sampling Width | 15 mm, 24 mm, 25.4 mm (customizable) |
| Sampling Length | 300 mm |
| Sample Quantity per Cycle | 6 strips |
| Sampling Accuracy | ±0.1 mm |
| Dimensions (L×W×H) | 420 × 330 × 145 mm |
| Weight | 8 kg |
| Measurement Range | ±2 kV |
|---|---|
| Test Distance | 5 mm – 25 m |
| Sensing Area Diameter | 25–175 mm |
| Accuracy | ±5% of full scale |
| Resolution | 1 V |
| Operating Temp. | 15–35 °C, RH ≤85% non-condensing |
| Drift | <600 ppm/hour (time), <600 ppm/°C (temp.) |
| Response Time | <25 ms |
| Display | 3.5-digit LCD |
| Dimensions | 31 × 59 × 173 mm |
| Weight | 200 g |
| Power | 9 V battery (8 h continuous operation) |
| Analog Output | Yes |
| Hold Function | Yes |
| Sensor Thickness | Ultra-thin probe design |
| Key Features | Max. crush force: 50 kN (5 T) |
|---|---|
| Sample chamber | W300 × D300 mm |
| Stroke range | 0–300 mm |
| Crush speed | 1–10 mm/s (adjustable, ±1 mm/s accuracy) |
| Force resolution | 1/500,000 FS |
| Force accuracy | ±0.5% of reading |
| Displacement resolution | 0.01 mm |
| Displacement accuracy | ±0.5% of reading |
| Data acquisition rate | ≥30 Hz |
| Voltage measurement | 0–36 V, ±0.1% FS |
| Temperature measurement | 0–600 °C, ±1 °C |
| Compliance | Designed per UN 38.3, GB/T 31485, IEC 62133, and ISO 12405 test protocols |
| Safety features | Dual-layer tempered explosion-proof observation window (350 × 400 mm), automatic pressure relief port, forced exhaust system, integrated LED lighting |
| Structural enclosure | Heavy-gauge cold-rolled steel (gray + blue epoxy finish) with stainless-steel interior |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | YL-S70 |
| Price Range | USD 1,400 – 7,200 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 10 N to 5 kN (dual-range configuration available) |
| Control Mode | Full PC-based closed-loop control |
| Force Resolution | 1/500,000 FS |
| Force Accuracy | Better than ±0.5% of full scale |
| Displacement Resolution | 1/500,000 mm |
| Sampling Rate | 50 Hz |
| Effective Stroke | 450 mm |
| Speed Range | 0.01–500 mm/min (customizable) |
| Test Space Width | 140 mm |
| Drive System | AC Servo Motor + Precision Ball Screw |
| Protection Features | Over-travel limit switch, overload cutoff, emergency stop, automatic fracture detection |
| Data Output Units | Force (N, kN, lbf, kgf), Displacement (mm, inch), Stress (MPa, Pa), Strain (%), and derived metrics (CPK, σ, median, trimmed mean, etc.) |
| Software Functions | Real-time multi-curve overlay (F–δ, F–t, δ–t, σ–ε), user-defined multi-step cyclic protocols, auto-return, auto-zero, bidirectional load cell polarity switching, 7 programmable test zones, 40 manual data points, 120 auto-sampled points |
| Included | USB/RS-232 interface cable, proprietary testing software, standard compression platens |
| Optional Accessories | Extensometers, custom fixtures (e.g., ASTM D3574 foam compression plates), dedicated PC workstation |
| Key | Origin: Guangdong, China |
|---|---|
| Manufacturer Type | Distributor |
| Country of Origin | China |
| Model | YL-S90 |
| Max Test Force | 20 kN |
| Force Range | 20 kN (Full Scale) |
| Force Accuracy | ±0.5% FS |
| Travel Distance | 800 mm |
| Displacement Resolution | 1/500,000 mm |
| Drive System | Stepper Motor + Precision Ball Screw |
| Control Interface | PC-based via USB/RS-232 |
| Compliant Standards | GB/T 2792, ASTM D3330, GB/T 12914, GB 13022, GB/T 1040, GB/T 14344, GB/T 2191, QB/T 2171, GB/T 10003 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model Series | YL6-5000EX (RC/DC variants), YL6-6000EX |
| Ionization Energy Options | 8.4 eV, 10.2 eV, 10.6 eV, 11.7 eV |
| Detection Limit | 0.1 ppb (for benzene-equivalent VOCs) |
| Measurement Range | 1–999 ppb |
| Display Units | ppm, ppb, mg/m³ |
| Data Storage Capacity | 20,000 measurement points |
| Certifications | BASEEFA EEx ia IIC T4, CENELEC EN 50020 |
| Intrinsic Safety Compliance | ATEX Directive 2014/34/EU, IECEx Scheme |
| Alarm Functions | STEL (15-min), TWA (8-hr), user-defined thresholds |
| Communication | Infrared (IR) port |
| Weight | < 0.8 kg (typical) |
| Battery Options | Rechargeable Li-ion (RC) or AA alkaline (DC) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | YM30B |
| Quotation | USD 940 (FOB Shanghai) |
| Instrument Type | Lid-Sealing Vertical Autoclave |
| Application Scope | Research & Clinical Laboratories |
| Chamber Volume | 30 L / 50 L / 75 L (Model-Dependent) |
| Sterilization Temperature Range | 105–135 °C |
| Operating Pressure Range | 0–0.22 MPa (gauge) |
| Heating Method | Immersed Electric Heating Elements |
| Sealing System | Radial Self-Inflating Silicone Rubber Gasket |
| Exhaust Method | Gravity Displacement |
| Safety Features | Dual-Stage Pressure Relief Valve, Low-Water-Level Auto-Replenishment with Audible/Visual Alarm, Overtemperature & Overpressure Interlock |
| Vacuum Degree | Not Applicable (Non-Vacuum Sterilizer) |
| Condensate Drain Capacity | Continuous discharge via bottom drain valve |
| Caster System | Lockable Swivel Casters with Brake |
| Key | Origin: Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Model | YN-ZD-Z-10 |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Standard Quartz Glass Distillation Apparatus |
| Output Rate | 10 L/h |
| Power Rating | 7.5 kW |
| Supply Voltage | 380 V AC |
| Construction Material | Electropolished 304 Stainless Steel |
| Safety Mechanism | Imported Dry-Run Detection Sensor |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | YN-ZD-Z-20 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Standard Quartz Glass Distillation Unit |
| Output Rate | 20 L/h |
| Heating Power | 13.5 kW |
| Supply Voltage | 380 V AC |
| Construction Material | AISI 304 Stainless Steel |
| Safety Mechanism | Imported Dry-Run Detection Sensor |
| Cooling Method | Recirculating Tap Water Condensation |
| Compliance | GB/T 11417–2015 (Chinese National Standard for Laboratory Distillers) |
| Max Capacity | 100 g |
|---|---|
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.3% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Plate Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| End-Point Modes | Timed & Automatic |
| Display Parameters | Moisture %, Solid %, Mass (g), Elapsed Time, Date |
| Max Capacity | 50 g |
|---|---|
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.2% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| End-Point Modes | Timer-Controlled & Automatic |
| Display Parameters | Moisture %, Solid %, Mass (g), Elapsed Time, Date |
| Max Capacity | 50 g |
|---|---|
| Readability | 10 mg |
| Repeatability (3 g sample) | ±0.5% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| End-Point Modes | Timed & Automatic |
| Display Parameters | Moisture %, Solid %, Weight (g), Elapsed Time, Date |
| Max Capacity | 50 g |
|---|---|
| Readability | 5 mg |
| Repeatability (3 g sample) | ±0.3% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| End-point Modes | Timed & Automatic |
| Display Parameters | Moisture %, Solid %, Mass (g), Elapsed Time, Date |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YP1002 |
| Capacity | 0–100 g |
| Readability | 10 mg |
| Pan Diameter | 130 mm |
| Dimensions (W×D×H) | 320 × 280 × 150 mm |
| Power Supply | AC/DC dual-mode |
| Interface | RS232C serial output |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | YP-1400 |
| Pricing | Upon Request |
| Tablet Diameter Range | 3–20 mm |
| Production Speed | 10–140 tablets/min |
| Maximum Compression Force | 40 kN (4000 kgf) |
| Motor Power | 1.2 kW |
| Electrical Supply | 220/240 V AC, 50/60 Hz, Single-Phase |
| Net Weight | 150 kg |
| Dimensions (L×W×H) | 650 × 400 × 650 mm |
| Frame Material | 304 Stainless Steel |
| Contact Parts Material | 316 Stainless Steel |
| Control System | Fully Automated, Stepless Speed Regulation |
| Optional Accessories | Custom-shaped tooling sets, gravity-fed hopper, casters for mobility |
| Compliance | Designed to meet core GMP design principles for laboratory-scale solid dosage manufacturing |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | YP-1400 |
| Pricing | Upon Request |
| Tablet Diameter Range | 3–20 mm |
| Compression Speed | 10–140 tablets/min |
| Maximum Compression Force | 4000 kgf |
| Motor Power | 1.2 kW |
| Voltage/Frequency | 220–240 V AC, 50/60 Hz |
| Dimensions (L×W×H) | 650 × 400 × 650 mm |
| Net Weight | 150 kg |
| Frame Material | 304 Stainless Steel |
| Contact Parts Material | 316 Stainless Steel |
| Control Mode | Fully Automatic, Stepless Speed Regulation |
| Optional Accessories | Custom-shaped punches, Hopper extension, Manual jog & reverse function |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | YP-1400 |
| Price | Upon Request |
| Tablet Diameter Range | 3–20 mm |
| Production Speed | 10–140 tablets/min |
| Maximum Compression Force | 4000 kgf |
| Motor Power | 1.2 kW |
| Voltage/Frequency | 220–240 V AC, 50/60 Hz |
| Dimensions (L×W×H) | 650 × 400 × 650 mm |
| Net Weight | 150 kg |
| Frame Material | 304 Stainless Steel |
| Contact Parts Material | 316 Stainless Steel |
| Control Mode | Fully Automatic, Stepless Speed Regulation |
| Optional Accessories | Custom-shaped punches, Hopper extension, Manual jog & reverse function |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | YP-1400 |
| Pricing | Upon Request |
| Production Speed | 10–140 tablets/min |
| Maximum Compression Force | 4000 kgf |
| Tooling Compatibility | Interchangeable Punches (3–20 mm diameter) |
| Motor Power | 1.2 kW |
| Electrical Supply | Single-phase, 220/240 V, 50/60 Hz |
| Dimensions (L×W×H) | 650 × 400 × 650 mm |
| Net Weight | 150 kg |
| Construction | 304 stainless steel frame |
| Control System | Fully automated, stepless speed regulation with jog-reverse function |
| GMP Compliance | Designed to meet core requirements of WHO-GMP and ISO 9001 for laboratory-scale pharmaceutical processing |
| Capacity | 2000 g |
|---|---|
| Readability | 0.1 g |
| Repeatability | ±0.1 g |
| Linearity | ±0.2 g |
| Pan Dimensions | 188 × 160 mm |
| Overall Dimensions | 270 × 190 × 75 mm |
| Power | AC adapter or 9 V DC battery |
| Interface | RS232 |
| Features | Auto-calibration, tare, counting mode, unit conversion, backlit LCD, level indicator, all-range tare, single-key operation |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | YP20K-1 |
| Price | USD 605 (approx.) |
| Capacity | 20 kg |
| Readability | 0.1 g |
| Repeatability | ±0.1 g |
| Linearity | ±0.2 g |
| Dimensions (W×D×H) | 310 × 285 × 100 mm |
| Pan Size | 238 × 286 mm |
| Power | AC adapter or 9 V DC battery |
| Display | Backlit LCD |
| Interface | RS232 |
| Features | Auto-calibration, full-range tare, piece counting, unit conversion, level indicator, one-key function activation |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | YPQYQ-6 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | YQ-580 |
| Pricing | Available Upon Request |
| Measurement Principle | Laser Backscatter Photometry |
| Output Signal | 4–20 mA (max. load 500 Ω) |
| Power Supply | DC 16–24 V ±10% |
| Power Consumption | ≤3 W |
| Dimensions | 160 × 160 × 250 mm |
| Weight | 4 kg |
| Operating Temperature | −40 °C to +65 °C |
| Relative Humidity | 0–100% RH |
| Measurement Range | 0–200 mg/m³ (standard), extendable to 0–10 g/m³ (custom configuration) |
| Detection Limit | 2 mg/m³ |
| Accuracy | ±2% FS |
| Maximum Stack Diameter | 15 m |
| Minimum Stack Diameter | 1 m |
| Max. Flue Gas Temperature | 300 °C (high-temp version available upon customization) |
| Installation | Single-ended, tool-free mechanical mounting |
| Compliance | Designed for continuous emission monitoring (CEMS) integration per GB/T 16157, HJ 75–2017, and compatible with ISO 12141, ASTM D6216, and EU BREF reference methods |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | YQ3000C |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Portable Flue Gas & Particulate Emission Analyzer |
| Sampling Principle | Isokinetic Pitot Tube Sampling + Gravimetric Collection + Potentiostatic Electrolytic Gas Sensing |
| Compliance | HJ/T 48–1999, JJG 968–2002, JJG 680–2007 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Origin | Domestic (China) |
| Model | YQH-100 / YQH-200 / YQH-1000 |
| Measuring Range | 0–100 µm / 0–200 µm / 0–1000 µm |
| Weight | 0.2 kg |
| Dimensions | Ø50 mm × 27 mm |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | YSD130(A) |
| Price Range | USD 140–280 |
| Frequency Range | 31.5 Hz – 8 kHz |
| Measurement Range | 30 dB – 130 dB |
| Accuracy | ±1.4 dB |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | YSD130 |
| Price Range | USD 280–700 |
| Frequency Range | 31.5 Hz–8.5 kHz |
| Measurement Range | 30 dB–130 dB |
| Accuracy | ±1.4 dB |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YSI 30 / YSI 30M |
| Price | Upon Request |
| Conductivity Range | 0–499.9 µS/cm (0.1 µS/cm res., ±0.5% FS), 0–4999 µS/cm (1.0 µS/cm res., ±0.5% FS), 0–49.99 mS/cm (0.01 mS/cm res., ±0.5% FS), 0–200.0 mS/cm (0.1 mS/cm res., ±0.5% FS) |
| Salinity Range | 0–80 ppt (0.1 ppt res., ±2% or ±0.1 ppt) |
| Temperature Range | −5 to +95 °C (0.1 °C res., ±0.1 °C ±1 LSD) |
| Cell Constant | 5.0 cm⁻¹ ±4% |
| Reference Temperature | Adjustable between 15–25 °C |
| Temp. Compensation Coefficient | 0–4% (adjustable) |
| IP Rating | >IP65 |
| Power | 9 V DC (six AA alkaline batteries, ~100 h typical life) |
| Dimensions | 24.1 × 8.9 × 5.6 cm |
| Weight | 0.77 kg |
| Data Storage | 50 readings (YSI 30M only, non-volatile memory) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YSI 3100 |
| Price | Upon Request |
| Conductivity Range | 0–49.99 µS/cm (0.01 µS/cm res., ±0.50%), 0–499.9 µS/cm (0.1 µS/cm res., ±0.50%), 0–4999 µS/cm (1 µS/cm res., ±0.50%), 0–49.99 mS/cm (0.01 mS/cm res., ±0.50%), 0–499.9 mS/cm (0.01 mS/cm res., ±0.50%) |
| Salinity Range | 0–80 ppt (0.1 ppt res., ±0.1 ppt or 2%) |
| Temperature Range | −5 to +95 °C (0.1 °C res., ±0.1 °C + 1 LSD) |
| Temperature Compensation | Linear, adjustable reference temp. 15–25 °C, coefficient 0–4 %/°C |
| Cell Constants | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| Calibration | Single-point |
| Display | LCD |
| Connector | 7-pin mini-DIN |
| Platinum Plating Function | Yes |
| Power Supply | 220 V AC |
| Certifications | UL, CSA, CE |
| Operating Humidity | Up to 95% RH (non-condensing) |