Generic
Filter
Showing 1921–1950 of 5102 results
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | HLH-700II |
| Pricing | Available Upon Request |
| Hydrogen Purity | >99.999% |
| Flow Rate | 0–700 mL/min |
| Output Pressure | 0–0.4 MPa (Factory Set at 0.3 MPa) |
| Max Power Consumption | 250 W |
| Operating Environment | 10–40 °C, RH ≤85%, Non-corrosive, Low-dust Ambient |
| Hydrogen purity | 99.999% |
|---|---|
| Hydrogen flow rate | 0–300 mL/min |
| Hydrogen output pressure | 0.4 MPa |
| Air flow rate | 0–2000 mL/min |
| Air output pressure | 0.4 MPa |
| Power consumption | 275 W |
| Dimensions (W×D×H) | 470 × 260 × 380 mm |
| Net weight | ~28 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EnSURE™ |
| Price | USD 3,800 (approx.) |
| Function Type | Single-Parameter Detection |
| Sample Format | Single-Sample Dedicated |
| Wavelength Range | 400–680 nm |
| Detection Time | <15 s |
| Repeatability | <5% RSD |
| Detection Channels | 1 |
| ATP Detection Limit | 0.1 fmol (1 × 10⁻¹⁶ mol) |
| Dynamic Range | 0–9999 RLU |
| Data Storage Capacity | 2000 records |
| Calibration | Auto-calibration within 60 s on power-up |
| Power Supply | Two AA alkaline batteries |
| Weight | 260 g |
| Display | Backlit LCD |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | HYSMB6-500 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–49.99 mL/min |
| Flow Accuracy | <0.5% |
| Flow Precision (RSD) | ≤0.2% |
| Maximum Operating Pressure | 8 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.4 nm |
| Baseline Noise | 2×10⁻⁵ AU (254 nm, 1 mL/min, methanol) |
| Data Acquisition Frequency | 5 Hz |
| Column Configuration | 8-column rotary valve system |
| Column Volume | 500 mL per column |
| Feed Flow Range | 0.5–10 mL/min |
| Eluent Flow Range | 0.5–15 mL/min |
| Product Flow Range | 0.1–30 mL/min |
| System Voltage | 220 V ±10%, 50 Hz |
| Total Power Consumption | 2 kW |
| Dimensions (W×D×H) | 450 × 450 × 800 mm |
| Weight | 3.0 kg |
| Communication Interface | RS-485 for external control and SCADA integration (e.g., KingView) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | HY-3000 |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Target Gases | CO, CO₂, CH₄, O₂, SO₂, H₂ |
| Response Time | ≤30 s |
| Zero Drift | ±2% FS / 48 h |
| Span Drift | ±2% FS / 48 h |
| Linearity Error | ±2% FS |
| O₂ Range Options | 0–2% or 0–25% vol |
| H₂ Range Options | 0–5% or 0–100% vol |
| CO Range | 0–5000 ppm (expandable) |
| CO₂/CH₄/SO₂ Ranges | 0–500 ppm / 0–500 ppm / 0–2000 ppm (all expandable) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | HZL-250/280 |
| Pricing | USD 3,200 (FOB Jiangsu) |
| Instrument Category | General-Purpose Orbital Shaker Incubator |
| Timer Range | 0–999 hours (digital programmable) |
| Oscillation Speed | 40–280 rpm (stepless adjustment) |
| Orbit Diameter | 25 mm |
| Temperature Range | 5–60 °C (ambient 25 °C) |
| Temperature Uniformity | ±0.1 °C across chamber |
| Chamber Volume | 250 L / 280 L variants |
| Shelf Configuration | Dual-tier stainless steel shaking platform |
| Input Power | 700 W (220 V, 50 Hz) |
| Compressor Power | 180 W (HZL-250) / 250 W (HZL-280) |
| External Dimensions (W×D×H) | 700 × 700 × 1500 mm |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HZL-X160 |
| Quotation | USD 2,200 (FOB) |
| Instrument Type | Benchtop Orbital Shaker-Incubator |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–280 rpm (continuously adjustable) |
| Orbit Diameter | 26 mm |
| Temperature Range | Ambient +5°C to 60°C (at 25°C ambient) |
| Shelf Configuration | Dual independent shelves |
| Chamber Capacity | 160 L (40 × 250 mL flasks per shelf, double-layer arrangement) |
| Temperature Uniformity | ±0.3°C across chamber |
| Temperature Accuracy | ±0.1°C (at setpoint, calibrated at 37°C) |
| Power Supply | 220 V AC, 50 Hz |
| Drive System | Microprocessor-controlled brushless DC motor |
| Dimensions (W×D×H) | 670 × 620 × 1320 mm |
| Net Weight | 128 kg |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HZL-X160 |
| Price | USD 2,850 (FOB Jiangsu) |
| Instrument Type | Water-Jacketed Constant-Temperature Orbital Shaker / Incubator Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–300 rpm (adjustable in 1-rpm increments) |
| Orbit Diameter | 26 mm |
| Temperature Range | 5–60 °C (ambient ≤25 °C) |
| Shelf Configuration | Single-tier platform (dual-layer capacity via stackable flask racks) |
| Chamber Volume | 160 L |
| Max Flask Load | 40 × 250 mL Erlenmeyer flasks (standard dual-layer arrangement) |
| Control System | Microprocessor-based PID controller with digital display |
| Drive Mechanism | Brushless DC motor |
| Power Supply | 220 V AC, 50 Hz |
| External Dimensions (W×D×H) | 670 × 620 × 1320 mm |
| Temperature Uniformity | ±0.3 °C across chamber (at 37 °C, steady state) |
| Temperature Stability | ±0.1 °C (setpoint deviation under load) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QJICWQ |
| Price | USD 7,700 (FOB Shanghai) |
| Max. Torsion Angle | ±15° ±1° (Bidirectional) |
| Torque Measurement Range | Optional (Configurable per ISO/IEC 7816-1 & GB/T 16649.1) |
| Torque Resolution | 60 measurements/min |
| Angular Displacement Measurement Range | Optional (Programmable up to ±30°) |
| Motor Power | 35 W |
| Bending Speed | 29 rpm |
| Test Cycle Count Range | 1–9999 cycles |
| Dimensions (L×W×H) | 670 × 380 × 220 mm |
| Net Weight | 70 kg |
| Input Voltage | AC 220 V ±5%, 50 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICD-1 |
| Price Range | USD 7,000 – 14,000 |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ID Micro EA |
| Price Range | USD 140,000–280,000 |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer |
| Resolution | >75 at m/z 29 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CHQC-20 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Detection Range | Adjustable |
| Detection Time | 24 h |
| Throughput | Configurable |
| Sampling Frequency | Configurable |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VDH-01 |
| Pricing | Available Upon Request |
| Standard Compliance | IEC 62493:2015+A1:2021 |
| Frequency Range | 20 kHz – 10 MHz |
| Output Impedance | 50 Ω |
| Interface | BNC |
| Sensor Diameter | 210 mm |
| Cable Length | 300 mm |
| Weight | 1.7 kg |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | IF2000 |
| Pricing | Available Upon Request |
| Max Furnace Temperature | 1600 °C (Peak: 1650 °C) |
| Operating Temp Range | 200–1550 °C |
| Atmosphere Control | Oxidizing or Reducing |
| Sample Capacity | 2 crucibles per run |
| Temperature Resolution | 4 °C |
| Image Capture Interval | 5 °C |
| Compliance | ASTM D1857, ISO 540, DIN 51730, AFNOR M03-003, AS 1038.19 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | IFC-2 |
| Price | USD 690 (FOB Beijing) |
| Flow Rate Range | 5–25 L/min (continuously adjustable) |
| Timer Range | 0–99 minutes |
| Power Supply | AC 220 V / DC rechargeable battery (≥3 h continuous operation) |
| Dimensions | 210 × 130 × 90 mm |
| Explosion Protection | Intrinsic Safety “ib I” per GB 3836.4–2021 / IEC 60079-11 |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IGT C1, IGT C1-Orange, IGT G1-5, IGT F1 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 600MR |
| Pricing | Upon Request |
| Measurement Range | 0–1000 g |
| Resolution | 1 g |
| Test Duration | 5–999 s (user-adjustable) |
| Platform Dimensions | 18″ × 18″ |
| Animal Weight Capacity | 180–270 g (optimized for adult mice and small rats) |
| Input Method | Keypad + Optional Footswitch |
| Data Output | RS-232 Serial Interface, Optional Thermal Printer Support |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 390 or 390G (Capacity: 6 Rats or 12 Mice) |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MRBP-R01 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IITC |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CP300 |
| Price | Upon Request |
| Heating Surface Material | Glass Ceramic |
| Housing Material | PTFE-Coated Stainless Steel |
| Heating Plate Dimensions (mm) | 300 × 300 |
| Effective Heating Area (mm) | 200 × 200 |
| Maximum Temperature | 400 °C |
| Power Rating | 900 W |
| Voltage/Frequency | 230 V / 50 Hz |
| Weight | 11 kg |
| Control Unit Dimensions (mm) | 150 × 160 × 65 |
| Main Unit Dimensions (mm) | 320 × 360 × 60 |
| Temperature Safety Indicator | “HOT” LED (activates ≥50 °C, remains active as long as mains power is connected) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | E2K |
| Operating Temperature Range | 0–60 °C |
| Temperature Repeatability | ≤0.1% RSD |
| Temperature Resolution | 1 µK |
| Gross Calorific Value Resolution | 0.001 MJ/kg |
| Calibration | 10 stored calibration curves per smart bomb vessel, automatic standard deviation correction, integrated calibration sensors per vessel |
| Sample Throughput | Up to 10 samples/hour (standard configuration) |
| Measurement Time | 1.5–3 min per test |
| Dimensions (W×D×H) | 280×400×290 mm |
| Weight | 9 kg |
| Data Storage Capacity | >1000 test records with full metadata (operator ID, ambient conditions, calibration traceability) |
| Connectivity | Ethernet-enabled for multi-unit network (up to 7 units) |
| Ignition Control | Adjustable ignition energy, programmable high/low sample mass limits, customizable test cycle parameters |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RV10 Basic / Digital / Control |
| Capacity | 3 L |
| Ultimate Vacuum | 2 mbar |
| Rotational Speed | 20–280 rpm |
| Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±1 K (Control/Digital models) |
| Condenser Surface Area | 1200 cm² |
| Lift Stroke | 140 mm |
| Heating Power | 1300 W |
| Input Power | 1400 W |
| Dimensions (W × D × H) | 500 × 430 × 410 mm |
| Weight | 19.6–21.5 kg |
| Protection Class | IP20 |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH |
| Compliance | DIN EN 12697-3 (Hot Bitumen Testing), DIN EN 60529 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HiSeq 2500 |
| Warranty Period | 6 months |
| Instrument Age | 3–4 years |
| Software Compatibility | Illumina BaseSpace, CASAVA v1.8.2+ |
| Run Modes | High-Throughput Mode (6-day run), Rapid Mode (27-hour run) |
| Output Capacity | Up to 1 TB (HT mode) or 120 GB (Rapid mode) per run |
| Read Length | SE >100 bp (HT), SE >150 bp (Rapid), PE >2×100 bp (HT), PE >2×150 bp (Rapid) |
| Input DNA Requirement | ≥0.1 µg |
| Raw Read Accuracy | ≥98.5% |
| Consensus Accuracy (3× coverage) | ≥99.99% |
| Homopolymer Resolution | ≥12 consecutive identical bases with ≥99% accuracy |
| Compliance | CE-IVD, FDA-listed device (for RUO use), GLP/GMP-ready workflow support |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ILW Series |
| Price Range | USD 2,700 – 6,800 (FOB) |
| Temperature Range | 0°C to +70°C (standard) |
| Temperature Uniformity | ±0.4°C |
| Humidity Control | Not integrated (dry-air forced convection only) |
| Chamber Capacity | 53 L, 112 L, 245 L, or 749 L configurations available |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | IM Series |
| Measurement Parameters | Gasoline Octane Number (ON), Diesel Cetane Number (CN) |
| Portability | Handheld Field-Deployable |
| Measurement Range | 40–120 ON, 40–60 CN |
| Accuracy | ±0.5 ON, ±1.0 CN |
| Analysis Time | <10 s per sample |
| Sample Volume | 10 mL |
| Temperature & Cloud Point Measurement | Integrated digital thermometry and diesel cloud point estimation |
| Compliance | ASTM D2699-86, ASTM D2700-86, ASTM D4737-03, ASTM D613, EN ISO 5165 |
| Calibration Interface | RS-232 serial connection for PC-based calibration using Windows Mobile-compatible software (Pocket PC 2000/2002) |
| Power Supply | 5.2 V DC internal / 5.8 V external |
| Dimensions (Main Unit) | 100 × 210 × 40 mm |
| Probe Dimensions | Ø60 × 100 mm |
| Battery Life | Up to 1000 hours of cumulative operational time |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Image-Pro |
| Price Range | USD 25,000 – 62,500 (based on configuration and modules) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SP-2100 |
| Price Range | USD 70,000 – 140,000 |
| Force Capacity | 25 lbf (111 N) |
| Speed Range | 0.2–300 in/min (0.5–762 mm/min) |
| Measurement Modes | Static Peak, Dynamic Peak, Valley, Average, RMS Force |
| Unit Systems | English, Metric, SI |
| Power Input | 90–264 VAC, 47–63 Hz |
| Compliance Standards | ASTM D1894, ASTM D3330, PSTC-1, PSTC-101, TLMI Test Method 7, FINAT FTM 1 & 2, TAPPI T 815 |
| Software | ExLink21 (Excel®-integrated data logging & plotting), StatsLink21 (statistical analysis: mean, SD, CV, batch reporting) |
| Drive System | Precision Servo Motor with Ball Screw Actuator |
| Control Architecture | Embedded Microprocessor with Standalone Operation Capability |
| Fixture Standard | 180° Peel Jig, COF Horizontal Test Fixture, Adjustable-Angle Peel Fixture |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iSCOUT |
| Price Range | USD 1,400 – 7,000 |
| Camera Resolution | 10 MP |
| Memory | 1 GB |
| Imaging Frequency | Up to 3 times per day (configurable) |
| GPS Integration | Built-in |
| Power Supply | Rechargeable Li-ion battery + 7.2 V / 333 mA solar panel (18 × 13 cm) |
| Dimensions | 20 × 15.5 × 17 cm |
| Weight | 930 g |
| Wireless Connectivity | Cellular (LTE-M/NB-IoT) or LoRaWAN |
| Data Platform | FieldClimate® cloud service |
| Coverage per Unit | 1–5 hectares |
| Trap Types | Pheromone-based, Drosophila-specific, General insect, Chromatic (blue/yellow/white) |
| Key | Table Surface Dimensions: 200 × 200 mm |
|---|---|
| Maximum Payload | 10 kg |
| Pulse Duration Range | 0.2–100 ms (programmable, auto-controlled) |
| Peak Acceleration Range | 50–9999 m/s² (programmable, auto-controlled) |
| Pulse Waveform | Half-sine (compliant with IEC 60068-2-27, GB/T 2423.5, GJB 150.18A, GJB 360B, JJG 497) |
| Shock Direction | Vertical |
| Dual-Impact Prevention | Hydraulic-friction braking system |
| Height Control | Digital preset + hydraulic lifting |
| Sampling Rate | 200 kHz |
| Signal Conditioning | Analog filtering + 160 dB/oct digital anti-aliasing filter |
| Repetition Rate | 0–100 shocks/min (±1% accuracy) |
| Power Supply | AC 380 V ±10%, 50 Hz, 3 kVA |
| System Mass | 2800 kg |
| Overall Dimensions | 750 × 2600 × 1000 mm |
| Software Platform | Windows XP-based, DAO data engine, automated Word report generation, real-time display of lift height, peak acceleration, pulse width, and Δv |