Generic
Filter
Showing 2011–2040 of 4965 results
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | J500 |
| Price Range | USD 2,100–7,000 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Refractive Index Range | 1.30000–1.70000 (nD) |
| Refractive Index Accuracy | ±0.00003 |
| Brix Range | 0–100% |
| Brix Accuracy | ±0.1% |
| Temperature Control Range | 5–65 °C |
| Temperature Stability | ±0.02 °C |
| Light Source | LED (589 nm) |
| Prism Material | Sapphire-grade |
| Sample Cell | Stainless Steel |
| Detector | High-resolution linear CCD array |
| Display | 7-inch TFT color touchscreen |
| Interface | USB + RS-232 |
| Power Supply | 220 V / 50 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J60 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min heating rate) |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Display | TFT high-definition color LCD |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 120 W |
| Data Interfaces | USB, RS-232, Ethernet |
| User Accounts | 8 configurable profiles |
| Melting Curve Storage | 10 complete thermal profiles |
| Total Data Storage | 400 melting events |
| Detection Mode | Fully automated optical detection (no manual override) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J600 |
| Price Range | USD 2,100–7,000 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Refractive Index Range | 1.30000–1.70000 (nD) |
| Refractive Index Accuracy | ±0.00002 |
| Brix Range | 0–100.00% |
| Brix Accuracy | ±0.01% |
| Temperature Control Range | 5–90 °C |
| Temperature Stability | ±0.01 °C |
| Light Source | LED (589 nm) |
| Prism Material | Sapphire-grade |
| Sample Cell | Stainless Steel |
| Detector | High-resolution linear CCD array |
| Display | 7-inch TFT color touchscreen |
| Interface | USB + RS-232 |
| Power Supply | 220 V AC / 50 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J70 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 8 GB internal flash |
| Image Storage | 400 frames |
| Video Recording | Yes (TFT-displayed real-time capture) |
| User Accounts | 8 configurable profiles |
| Display | TFT high-definition true-color LCD |
| Interface | USB, RS-232, Ethernet |
| Power | 220 V AC, 50 Hz, 120 W |
| Magnification | 7× optical |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J80 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min ramp rate |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 16 GB internal |
| Melting Curve Records | 600 traces |
| Video Recordings Stored | 20 full sequences |
| User Accounts | 10 configurable profiles |
| Imaging | High-definition CMOS video module (7× optical magnification) |
| Display | TFT true-color touchscreen |
| Connectivity | USB, RS-232, Ethernet |
| Power | 220 V AC, 50 Hz, 120 W |
| Operating Modes | Fully automated + manual override |
| Preloaded Methods | 40 validated protocols |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J90 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 420 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 32 GB internal SSD |
| Image/Video Storage | Up to 1,000 frames + 80 complete melting profiles |
| User Accounts | 20 configurable roles with password protection |
| Operating Interface | 7-inch TFT full-color touchscreen |
| Connectivity | USB 2.0, RS-232, Ethernet |
| Optical Magnification | 7× |
| Integrated Thermal Printer | Yes |
| Reference Standard Set Included | Yes |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JA Series |
| Pricing | Available Upon Request |
| Capacity Range | 120–4100 g |
| Readability | 0.001 g (models up to 4103) / 0.01 g (models 12002 and above) |
| Repeatability | ≤ ±0.001 g (0.001-g readability models) / ≤ ±0.01 g (0.01-g readability models) |
| Linearity | ≤ ±0.002 g (0.001-g models) / ≤ ±0.02 g (0.01-g models) |
| Pan Diameter | Φ120 mm (JA1203–JA4103) / Φ158 mm (JA12002–JA41002, MP500B, MP1100B) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JA12002 |
| Capacity | 1200 g |
| Readability | 10 mg |
| Repeatability | ±10 mg |
| Linearity | ±20 mg |
| Dimensions (W×D×H) | 200 × 270 × 80 mm |
| Pan Diameter | Φ158 mm |
| Power Options | AC Adapter or 9 V DC Battery |
| Interface | RS232 |
| Display | Backlit LCD |
| Draft Shield | Five-sided glass enclosure |
| Sensor Type | Electromagnetic force compensation |
| Environmental Compensation | Dynamic temperature compensation |
| Functions | Tare, auto-zero tracking, counting, unit conversion (g, oz, ct), overload protection & alarm, under/overload indication |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Models | JA1003 (100 g), JA2003 (200 g), JA3003 (300 g), JA4003 (410 g), JA5003 (500 g) |
| Readability | 1 mg |
| Repeatability | ≤1 mg |
| Linearity | ±2 mg |
| Pan Diameter | Φ110 mm |
| Draft Shield Dimensions | 198 × 225 × 240 mm |
| External Dimensions | 212 × 330 × 323 mm |
| Power Options | AC adapter (included) or 9 V DC battery |
| Interface | RS232 serial port |
| Display | Backlit LCD with adjustable contrast |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J0317 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HD-2.5″ / HD-3.5″ / HD-2.5″G / HD-2.5″GW / HD-3.5″G / HD-3.5″GW |
| Heating Chamber Surface Finish | Stainless Steel / Gold-Plated / Gold-Plated with Integrated Water-Cooling Loop |
| Heating Method | Resistive, Dual-Zone (Top & Bottom) Independent Control |
| Purge Gas | N₂ or He, up to 200 mL/min |
| Cooling System | Integrated Recirculating Water Chiller (W/GW models), 4 kg mass |
| Dimensions (Main Unit) | Ø125 × 230 mm (H), 4 kg |
| Dimensions (Controller) | 170(W) × 140(H) × 220(D) mm, 4.5–6 kg |
| Power Supply | AC 100 V, 5 A or AC 115 V |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JHP-5 |
| Instrument Type | Curie-Point Pyrolyzer |
| Heating Method | High-Frequency Induction (600 kHz, 48 W) |
| Pyrolysis Time Range | 1 s – 99 h |
| Flow Path Switching | Solenoid Valve |
| Sensor Unit Dimensions/Weight | 90 × 280 × 160 mm / 2.5 kg |
| RF Power Supply Dimensions/Weight | 160 × 250 × 380 mm / 8 kg |
| Power Input | AC 100–240 V, 5 A |
| GC Compatibility | Universal (all standard GC systems, excluding proprietary non-standard interfaces) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1602W |
| Price Range | USD 13,500 – 67,500 |
| Instrument Type | Multi-Station Martindale Tribological Tester |
| Test Stations | 2 / 5 / 9 configurable |
| Display | 7-inch capacitive touchscreen interface |
| Counter | Independent station-based digital counter with real-time cycle tracking and estimated end-time prediction |
| Sample Holders | Interchangeable clamping fixtures for flat and contoured specimens |
| Compliance | Designed to meet ISO 12947-1/2/3, ASTM D4966, BS EN ISO 12947, GB/T 21196.1–21196.4 |
| Origin | Japan |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | DM / VA / VF / AGM / VLX / VMX Series Pneumatic Hoists, W-Series Pneumatic Winches |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CG-77 |
| Quotation | Available Upon Request |
| Combustion Method | Thermal Decomposition–Oxidation |
| Combustion Tube Dimensions | 14 mm ID × 120 mm L |
| Heating Method | Curie-Point Induction Heating |
| RF Power Supply | 150 W Output |
| Ignition Coil Material | Nichrome Alloy |
| Operating Modes | Switchable Thermal Decomposition / Combustion via Front Panel Button |
| Combustion Chamber & Insulation Tube Temp Range | Ambient to 200 °C |
| Adsorption Tube Temp Range | Ambient to 200 °C (Optional CryoFocus Cryogenic Focusing Module Compatible) |
| Adsorption Tube Dimensions | 12 mm ID × 120 mm L |
| Auxiliary Gas Flow Rate | 0–500 mL/min, Pressure-Regulated |
| Dimensions (W×H×D) | 280 × 300 × 440 mm |
| Power Supply | 100 V AC, 4 A |
| Weight | 27.5 kg |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FI/IR NRS |
| Price | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JAW1 |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Instrument Type | Jaw Crusher |
| Sample Suitability | Brittle to Hard & Tough-Brittle Materials |
| Output Particle Size | ≥ 0.5 mm |
| Maximum Feed Size | < 14 mm |
| Jaw Opening Dimensions | 81 × 51 mm |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JAW2 |
| Instrument Type | Jaw Crusher |
| Sample Applicability | Hard, Brittle, and Medium-Hard Materials |
| Output Particle Size | ≥ 0.5 mm |
| Maximum Feed Size | < 15 mm |
| Batch Processing Capacity | 152 × 76 mm feed opening |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | JB Aqua Plus |
| Price | Upon Request |
| Temperature Range | Ambient + 5°C to 98°C |
| Temperature Setting Range | 10–99°C (0.1°C resolution) |
| Stability | ±1.0°C |
| Control Type | Analog dial |
| Heating Power | 0.13–2.1 kW |
| Working Volume | 2–34 L (including dual-chamber 5+12 L variant) |
| Construction | Stainless steel tank and housing |
| Safety Features | Adjustable overheat cutoff, dry-run protection |
| Standard Accessories | Polycarbonate dome lid, insulated base |
| Drain Valve | Optional on JB Aqua 12 Plus, 18 Plus, 26 Plus (introduced 2010) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | JB |
| Price Range | USD 1,400–2,800 |
| Instrument Type | Pendulum Impact Tester |
| Impact Energy | 2.156 J |
| Impact Velocity | Adjustable |
| Pendulum Torque (Impact Constant) | 120 N·mm |
| Load Cell Range | 100 N |
| Maximum Lifting Height | 120 mm |
| Scale Division Value | 0.028 J |
| Pendulum Raise Angle | 120° |
| Distance from Pendulum Pivot to Impact Point | 300 mm |
| Vertical Travel of Test Table | 120 mm |
| Longitudinal Travel of Test Table | 210 mm |
| Sample Dimensions | Flat plates 6–10.5 inches in diameter |
| Net Weight | 50 kg |
| Overall Dimensions | 890 × 370 × 925 mm |
| Key | Max Test Load: 20 kN |
|---|---|
| Accuracy Class | ISO 7500-1 Class 1 |
| Speed Range | 1–500 mm/min |
| Effective Stroke | ~900 mm |
| Load Resolution | 0.001 N |
| Load Accuracy | ±0.01% FS |
| Displacement Resolution | ±0.005% (JIS-compliant encoder) |
| Control System | Full-digital triple-closed-loop (force, displacement, strain) with adaptive PID algorithm |
| Data Acquisition | 1/300,000 internal resolution, auto-ranging |
| Compliance | ASTM E4, ASTM E8, ISO 6892-1, GB/T 228.1, EN 10002-1 |
| Software | Windows-based, bilingual (EN/CN), CFR Part 11-ready audit trail & user permission management |
| Interface | USB-standard I/O, dual-display mode (touchscreen + PC) |
| Power | 220 V AC |
| Weight | 270 kg |
| Dimensions (W×D×H) | 900 × 400 × 1600 mm |
| Key | Max Test Load: 100 kN |
|---|---|
| Accuracy Class | 0.5 |
| Load Resolution | 0.001 N |
| Speed Range | 0.001–500 mm/min |
| Effective Stroke | ~1000 mm |
| Position Resolution | ±0.005% (encoder-based) |
| Load Accuracy | ±0.05% |
| Control System | Full-digital triple-closed-loop (force, displacement, strain) with adaptive PID algorithm |
| Drive Motor | Panasonic servo motor |
| Mechanical Transmission | High-precision Taiwanese ball screw |
| Software | Windows-based, bilingual (EN/CN), ASTM/ISO-compliant data processing |
| Compliance | Meets ISO 7500-1, ASTM E4, ASTM E8/E21, GB/T 228.1, and GLP-ready audit trail functionality |
| Power Supply | 380 V AC |
| Weight | 860 kg |
| Dimensions (W×D×H) | 1200 × 650 × 1800 mm |
| Key | Pulse Pressure Range: 0–40 MPa |
|---|---|
| Burst Pressure Capacity | 0–500 MPa |
| Pulse Frequency | 0–5 Hz (adjustable) |
| Cycle Count Capability | ≥300,000 cycles |
| Test Media | Water, Oil, or Ethylene Glycol Mixtures |
| Waveform Options | Square, Trapezoidal, Triangular, Sine, or Custom |
| Compliance Standards | ISO 6802:1991, SAE J157, SAE J2044, BS EN ISO 6803:2008, GB/T 5568–2006, GB 7939–2008, GB/T 12722–2008, GB/T 5563–1994, GB/T 10544–2003, GB/T — Hydraulic Burst & Pressure Hold Testing for Plastic Pipes |
| Key | Origin: Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JC-300B |
| Quotation | Available Upon Request |
| Max Impact Energy | 300 J |
| Max Drop Height | 2 m |
| Hammer Displacement Accuracy | ±2 mm |
| Max Combined Hammer Mass | 15 kg |
| Mass Tolerance per Weight | ±5 g |
| Hammer Tip Radii | SR=5, 10, 20, 30, 50 mm |
| Adjustable Hammer Masses | 1–10 kg (1 kg increments), plus 15 kg |
| Lifting Force Limit | ≤20 kgf |
| Impact Center Alignment Tolerance | ≤2 mm |
| Test Chamber Dimensions | 250 mm (H) × 300 mm (W) |
| Ring Clamps for Sheet Specimens | Φ40±1.0 mm, Φ80±2.0 mm, Φ130±2.5 mm |
| V-Notch Fixture for Pipes | 300 mm length, 120° opening angle |
| Recommended Sample Range | Pipes Φ20–Φ200 mm |
| Power Supply | AC 220 V |
| Overall Dimensions | 600×600×3100 mm |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | XJY6 / XJY10 / XJY16 / XJY20 |
| Pricing | Available Upon Request |
| Measurement Range | 0–180° |
| Angular Resolution | <0.25° |
| Image Magnification | 266 pixels/mm |
| Measurement Methods | Sessile Drop, Pendant Drop |
| Temperature Control | Integrated Thermostatic Stage with External Circulating Bath Interface |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biogas 5000 |
| Price | USD 6,800 (FOB UK) |
| Certification | ATEX II 2G Ex ib IIA T1 Gb, IECEx, MCERTS (under application), UKAS ISO/IEC 17025 (Accreditation No. 4533) |
| Gas Channels | CH₄, CO₂ (dual-channel NDIR), O₂, CO (H₂-compensated), H₂S (optional ranges: 0–500 / 0–5,000 / 0–10,000 ppm), NH₃, H₂ (configurable) |
| Accuracy | CH₄ & CO₂ ±0.5% vol (0–70% / 0–60%), O₂ ±1.0% vol (0–25%), CO ±2.0% FS (0–500 ppm), H₂S ±2.0% FS (0–500 ppm) |
| Response Time (T90) | CH₄/CO₂ ≤10 s, O₂ ≤20 s, CO/H₂S ≤30 s |
| Battery | Rechargeable NiMH pack, 8 h continuous operation, 3 h full charge |
| Data Storage | 10,000 sample IDs, 10,000 datasets, 10,000 event logs |
| Environmental Rating | IP65, operating temp –10 to +50 °C, RH 0–95% non-condensing |
| Dimensions | 220 × 155 × 60 mm |
| Weight | 1.5 kg |
| Pressure Range | ±500 mbar (rel.), atmospheric 500–1500 mbar (±5 mbar), vacuum limit –375 mbar |
| Flow Rate | 550 mL/min (pump), integrated well-flow probe: 0–20 L/h |
| Accessories | Removable 2.0 µm PTFE filter, optional temperature probe (–10 to +75 °C, ±0.5 °C), GPS module, Bluetooth/USB interface |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Jerome 631X |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Jerome-860 |
| Pricing | Available Upon Request |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | 1156A |
| Detection Parameter | Single-parameter (Conductivity) |
| Portability | Portable |
| Conductivity Range | 0–1999 pS/m |
| Resistivity Range | 0–1999 pS/m (inverted scale) |
| Temperature Range | 32–165 °F (0–75 °C) |
| Accuracy | ±2% of reading |
| Minimum Resolution | 1 pS/m |
| Calibration | Internal auto-calibration |
| Display | LCD with over-range indicator ("1" on left) |
| Power Supply | Three 6 V alkaline batteries |
| Enclosure | Anodized aluminum housing with corrosion-resistant coating |
| Probe | Detachable, ruggedized for field use |
| Compliance | ASTM D2624, ASTM D4308, ISO 6297, GB/T 6539, GB 6950, GB 13348 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JF-3000 |
| Price | Upon Request |
| Measurement Range | CO: 0–5% vol, O₂: 0–10% vol |
| Alarm Setpoint Range | 10–90% of Full Scale |
| Zero Drift | ≤ ±1% FS (after 8-hr warm-up, 48-hr continuous operation) |
| Sensitivity Drift | ≤ ±1% FS |
| Temperature Influence | ≤ 3% FS over 5–40°C |
| Response Time (T₉₀) | ≤ 2 min |
| Sample Flow Rate | 0.5 L/min |
| Output Relay Capacity | 220 V AC / 5 A |
| Dimensions | 1800 × 610 × 700 mm |
| Weight | ~180 kg |