Generic
Filter
Showing 2281–2310 of 5744 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | tubing |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PinPort™ Series (PNP3F22, PNP3F25, PNP3M, etc.) |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Swivel |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Catheter |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tether |
| Pricing | Available Upon Request |
| Frame Capacity | 1,000 kN |
|---|---|
| Test Speed | 100 mm/min |
| Actuator Stroke | 254 mm |
| Crosshead Adjusting Speed | 300 mm/min |
| Compression Opening | 0–1000 mm |
| Horizontal Opening (Between Columns) | 741 mm |
| Test Space Configuration | Dual-Space (Tension & Compression) |
| Jaw Interface | Hydraulic Open-Front & Manual Closed-Pocket Crossheads |
| Specimen Flexibility | Multi-size Coverage with Minimal Jaw Face Set |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | INTEGRASLICE-P |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | V4.0 |
| Price | USD 5,300 (FOB Beijing) |
| Power Supply | 100–240 V AC, 50/60 Hz, 110 W |
| Operating Pressure Range | 500–6900 mbar |
| Low Inlet Pressure Threshold | 3000 mbar |
| Dimensions (W × D × H₁ × H₂) | 400 × 380 × 100 × 235 mm |
| Test Accuracy | Net Volume ±4% |
| Environmental Operating Conditions | 5–35 °C, 10–80% RH |
| Test Duration | Water Intrusion Test = preset time + 5 min ±2 min |
| Data Storage | 500 test records (expandable to 1000), including full pressure/flow curves |
| Display | 5.7" monochrome TFT LCD with backlight |
| Communication Interface | RS232 serial port |
| Language Support | English, Chinese |
| Compliance | Designed to support ASTM F838-22, ISO 13408-2, USP <1207>, and EU Annex 1 requirements for filter validation and integrity testing |
| [Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Integtest™ v4.0 |
| Price | USD 5,300 (FOB Beijing)] |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 4160-2 |
| Price | USD 3,650 (FOB) |
| Principle | Electrochemical Sensor |
| Measurement Range | 0–19.99 ppm |
| Extended Low-Range Mode | 0–500 ppb |
| Resolution | 0.01 ppm |
| Accuracy | ±2% Rd ±0.01 ppm |
| Flow Rate | 1.0 L/min |
| Dimensions | 178 × 102 × 225 mm |
| Weight | 2.0 kg |
| Power | Rechargeable Li-ion battery with real-time voltage monitoring |
| Certification | China NIM Type Approval (Certificate No. 2021F012), Evaluated by Chinese Center for Disease Control and Prevention – Institute of Environmental Health and Related Product Safety |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Stomacher® 400 Circulator |
| Instrument Type | Laboratory Paddle Blender |
| Compliance | ISO 6887-1, EN ISO 6887-1, AOAC 990.12, USP <61>, FDA Bacteriological Analytical Manual (BAM) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Intratracheal Inhalation Exposure System |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Models | PE-10, PE-20, PE-50, PE-90, PE-100, PE-160, PE-190, PE-205, PE-240, PE-260, PE-280, PE-320, PE-330, PE-350, PE-380 |
| Length Options | 3 m (10 ft), 30.5 m (100 ft) |
| Material | Medical-Grade Polyethylene (PE), USP Class VI Compliant |
| Inner Diameter Range | 0.28–4.0 mm |
| Outer Diameter Range | 0.61–6.0 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | IBP-2000 |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TIGER |
| Price Range | USD 1,400 – 7,000 (est.) |
| Detection Principle | Photoionization Detection (PID) |
| Instrument Type | Portable |
| Typical Configuration | Total VOC (TVOC) Detector |
| Measurement Range | 1 ppb – 20,000 ppm |
| Resolution | 1 ppb or 0.001 mg/m³ |
| Accuracy | ±5% of reading, ±1 digit |
| Response Time | T90 < 2 seconds |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PTR-TOF 4000 |
| Pricing | Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Origin Region | Netherlands |
| Model | IP2000 |
| Pricing | Upon Request |
| Standards Compliance | ISO 6272, ASTM D2794 |
| Optional Accessories | 1 kg and 2 kg Additional Weights |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | IPCE |
| Price | €40,000 |
| Measurement Mode | AC |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | IPS |
| Pricing | Upon Request |
| Core Components | Semiconductor Laser Source & Integrated Packaging |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | IPX-LC |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IQ-350 |
| Pricing | Available Upon Request |
| Power Supply | 4×C alkaline batteries, optional NiCd rechargeable battery or AC adapter/charger |
| Battery Life | 20 hrs (alkaline), 12 hrs (NiCd) |
| Sensor Options | Solid-state, electrochemical, IR, PID |
| Gas Selection | User-configurable from >150 toxic, combustible, or volatile organic compounds |
| Resolution | 0.01 ppm (0–10 ppm), 0.1 ppm (10–100 ppm), 1 ppm (100–1000 ppm) |
| Accuracy | ±5% of reading |
| Sampling Method | Integrated diaphragm pump with 1.2 m sampling tube |
| Display | 3-digit LED |
| Alarm | Dual adjustable threshold (low/high), visual & audible |
| Operating Temperature | –20 °C to +50 °C |
| Storage Temperature | –20 °C to +60 °C |
| Humidity Range | 0–99% RH (non-condensing) |
| Enclosure | Anodized aluminum housing |
| Dimensions | 181.1 × 85.9 × 101.6 mm |
| Weight | 1.14 kg (incl. batteries) |
| Standard Accessories | Host unit, sampling probe, alkaline batteries, 110 VAC adapter/charger, operator manual, calibration certificate, washable carry case |
| Optional Accessories | NiCd rechargeable battery pack, 110/220 VAC universal converter |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | IQ-Thermo |
| Pricing | Upon Request |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment Mode | Ground-based |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 7 nm |
| Spatial Resolution (IFOV) | 512 pixels |
| Field of View (TFOV) | 31° |
| LWIR Band | 7.5–13.5 µm |
| IR Detector Resolution | 640 × 512 px |
| Thermal Sensitivity | ≤0.03 °C (30 mK) @ 30 °C |
| Temperature Range Options | −25 to +150 °C or +40 to +550 °C (optional up to +1500 °C) |
| Frame Rate Options | 9 / 30 / 60 Hz |
| Optical Aperture | f/1.7 |
| Spectral Bands | 204 (with optional binning: 2× or 3×) |
| GPS Integration | Yes (geotagged data cubes) |
| Enclosure Rating | IP65 |
| Data Interfaces | USB 3.0, GigE, Wi-Fi |
| Output Formats | CSV, radiometric JPEG, non-radiometric JPEG, radiometric video, AVI, MP4 |
| Software Features | SAM algorithm, ROI temperature profiling, isotherm mode, thermal 3D surface mapping, report generation |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | IR 400-KA |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IR 400KA |
| Pricing | Available Upon Request |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | IR VIVO NIR-II Multispectral In Vivo Imaging System |
| Price Range | USD 13,500 – 27,000 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | IR-2 |
| Pricing | Available Upon Request |
| Measurement Principle | Normal Reflectance Method (via Integrated Blackbody Source) |
| Spectral Bands | 3–5 µm, 8–14 µm, 1–22 µm |
| Emissivity Range | 0.100–0.990 |
| Sensitivity (NEΔε) | 0.001 |
| Accuracy | ±0.02 (for ε > 0.50) |
| Repeatability | ±0.01 |
| Sample Temperature Range | Ambient to 300 °C (with optional heating stage) |
| Sample Diameter | Ø50 mm |
| Measurement Time | <3 s after trigger |
| Display Resolution | 0.001 (LED digital) |
| Interface | RS-232 serial port |
| Power Supply | AC 220 V, 50 Hz |
| Key | Origin: Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | IR-2 |
| Pricing | Available Upon Request |
| Measurement Bands | 3–5 µm, 8–14 µm, 1–22 µm |
| Emissivity Range | 0.100–0.990 |
| NEΔε (Noise-Equivalent Emissivity Change) | 0.001 |
| Accuracy | ±0.02 (for ε > 0.50) |
| Repeatability | ±0.01 |
| Sample Temp. Range | Ambient to 300 °C (optional heated stage) |
| Max. Sample Diameter | 50 mm |
| Measurement Time | < 3 s after trigger |
| Display Resolution | 0.001 (LED) |
| Power Supply | AC 220 V, 50 Hz |
| Interface | RS-232 serial port |
| Optical Method | Normal-incidence reflectance-based emissivity derivation using calibrated blackbody source |
