Generic
Filter
Showing 2191–2220 of 5744 results
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HY-939CS |
| Pricing | Available Upon Request |
| Load Capacity Options | 2 / 5 / 10 / 50 / 100 / 200 kgf |
| Load Accuracy | ±0.5% of reading (within 0.4–100% of full scale) |
| Force Resolution | ±1/200,000 of maximum test load |
| Displacement Accuracy | ±0.5% of reading (within 2–100% FS) |
| Displacement Resolution | 0.005 mm |
| Large-Deformation Measurement Range | 10–800 mm |
| Large-Deformation Accuracy | ±0.5% of reading (within 2–100% FS) |
| Large-Deformation Resolution | 0.008 mm |
| Drive System | Panasonic 750 W AC servo motor + HIWIN precision ball screw + rotary encoder |
| Speed Range | 0.05–500 mm/min (optional 0.1–1000 mm/min) |
| Speed Accuracy | ±0.5% of set value |
| Test Stroke | 600 mm or 1000 mm (adjustable gauge length, fixture excluded) |
| Force Sensor Configuration | Up to four interchangeable load cells (max. 2 kN per channel) |
| Software Platform | Windows-based proprietary testing software with modular standard compliance, real-time multi-curve plotting, auto-calculation of mechanical parameters, and export to Excel, TXT, HTML |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | HY603 |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Reciprocating Tribological Tester |
| Maximum Friction Force | 26.7 N |
| Friction Force Resolution | 0.1 N |
| Maximum Test Temperature | 35 °C |
| Standards Compliance | ASTM D4157, ASTM D3597, FED-STD-191A Method 5304, SAE J948, SAE J1530, GM 2756M, Toyota TSL 4L120G, BS EN ISO 12402-2 |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HY780A |
| Price | Upon Request |
| Clamp Sets | 4 |
| Weight Load | 250 ± 3 g per clamp |
| Max Clamp Spacing (movable to fixed) | 310 mm |
| Movable Clamp Stroke | 35 mm |
| Oscillation Frequency | 60 cycles/min |
| Test Geometry | 52.2° angle, 120 mm travel distance |
| Counter | LCD display, 0–999,999, four independent channels |
| Standards Compliance | DIN 4843, QB/T 2226, SATRA PM154, BS 5131 |
| Calibration | CNAS-accredited calibration certificate included |
| Frequency | 2450 MHz ±50 MHz |
|---|---|
| Power Output | 0–1500 W (non-pulsed continuous & adjustable pulsed modes) |
| Temperature Range | 0–300 °C, accuracy ±1 °C |
| Temperature Sensor | Pt100 contact probe with corrosion-resistant tip |
| Timing Control | 0–900 min, resolution 1 s |
| Reaction Volume | 10–1000 mL |
| Stirring | Dual-mode (magnetic & mechanical, speed continuously adjustable) |
| Safety | Microwave leakage < GB 10436-2008 limit |
| Control System | Industrial PLC + full-color Chinese touchscreen HMI |
| Safety Interlocks | Magnetron overtemperature protection, door interlock, cavity shielding |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HYDRO CH4 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HYDRO-CO2 |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Hydro-Watch |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC300, GC600 |
| Hydrogen Flow Rate | 300 mL/min, 600 mL/min |
| Purity | ≥99.9999% (6.0 N) |
| Output Pressure | Up to 200 psig (13.8 bar) |
| Water Feed | Automatic Deionized Water Intake |
| Core Technology | Proton Exchange Membrane (PEM) Electrolysis |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HG Series (HG-80 to HG-1500) |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HLH-1L |
| Pricing | Available Upon Request |
| Hydrogen Purity | >99.999% |
| Flow Rate | 0–1 L/min |
| Output Pressure | 0–0.4 MPa (Factory Set at 0.3 MPa) |
| Max Power Consumption | 400 W |
| Operating Environment | 10–40 °C, Relative Humidity ≤85%, Non-corrosive, Low-dust Ambient |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | HLH-700II |
| Pricing | Available Upon Request |
| Hydrogen Purity | >99.999% |
| Flow Rate | 0–700 mL/min |
| Output Pressure | 0–0.4 MPa (Factory Set at 0.3 MPa) |
| Max Power Consumption | 250 W |
| Operating Environment | 10–40 °C, RH ≤85%, Non-corrosive, Low-dust Ambient |
| Hydrogen purity | 99.999% |
|---|---|
| Hydrogen flow rate | 0–300 mL/min |
| Hydrogen output pressure | 0.4 MPa |
| Air flow rate | 0–2000 mL/min |
| Air output pressure | 0.4 MPa |
| Power consumption | 275 W |
| Dimensions (W×D×H) | 470 × 260 × 380 mm |
| Net weight | ~28 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EnSURE™ |
| Price | USD 3,800 (approx.) |
| Function Type | Single-Parameter Detection |
| Sample Format | Single-Sample Dedicated |
| Wavelength Range | 400–680 nm |
| Detection Time | <15 s |
| Repeatability | <5% RSD |
| Detection Channels | 1 |
| ATP Detection Limit | 0.1 fmol (1 × 10⁻¹⁶ mol) |
| Dynamic Range | 0–9999 RLU |
| Data Storage Capacity | 2000 records |
| Calibration | Auto-calibration within 60 s on power-up |
| Power Supply | Two AA alkaline batteries |
| Weight | 260 g |
| Display | Backlit LCD |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | HYSMB6-500 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–49.99 mL/min |
| Flow Accuracy | <0.5% |
| Flow Precision (RSD) | ≤0.2% |
| Maximum Operating Pressure | 8 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.4 nm |
| Baseline Noise | 2×10⁻⁵ AU (254 nm, 1 mL/min, methanol) |
| Data Acquisition Frequency | 5 Hz |
| Column Configuration | 8-column rotary valve system |
| Column Volume | 500 mL per column |
| Feed Flow Range | 0.5–10 mL/min |
| Eluent Flow Range | 0.5–15 mL/min |
| Product Flow Range | 0.1–30 mL/min |
| System Voltage | 220 V ±10%, 50 Hz |
| Total Power Consumption | 2 kW |
| Dimensions (W×D×H) | 450 × 450 × 800 mm |
| Weight | 3.0 kg |
| Communication Interface | RS-485 for external control and SCADA integration (e.g., KingView) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | HY-3000 |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Target Gases | CO, CO₂, CH₄, O₂, SO₂, H₂ |
| Response Time | ≤30 s |
| Zero Drift | ±2% FS / 48 h |
| Span Drift | ±2% FS / 48 h |
| Linearity Error | ±2% FS |
| O₂ Range Options | 0–2% or 0–25% vol |
| H₂ Range Options | 0–5% or 0–100% vol |
| CO Range | 0–5000 ppm (expandable) |
| CO₂/CH₄/SO₂ Ranges | 0–500 ppm / 0–500 ppm / 0–2000 ppm (all expandable) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | HZL-250/280 |
| Pricing | USD 3,200 (FOB Jiangsu) |
| Instrument Category | General-Purpose Orbital Shaker Incubator |
| Timer Range | 0–999 hours (digital programmable) |
| Oscillation Speed | 40–280 rpm (stepless adjustment) |
| Orbit Diameter | 25 mm |
| Temperature Range | 5–60 °C (ambient 25 °C) |
| Temperature Uniformity | ±0.1 °C across chamber |
| Chamber Volume | 250 L / 280 L variants |
| Shelf Configuration | Dual-tier stainless steel shaking platform |
| Input Power | 700 W (220 V, 50 Hz) |
| Compressor Power | 180 W (HZL-250) / 250 W (HZL-280) |
| External Dimensions (W×D×H) | 700 × 700 × 1500 mm |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HZL-X160 |
| Quotation | USD 2,200 (FOB) |
| Instrument Type | Benchtop Orbital Shaker-Incubator |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–280 rpm (continuously adjustable) |
| Orbit Diameter | 26 mm |
| Temperature Range | Ambient +5°C to 60°C (at 25°C ambient) |
| Shelf Configuration | Dual independent shelves |
| Chamber Capacity | 160 L (40 × 250 mL flasks per shelf, double-layer arrangement) |
| Temperature Uniformity | ±0.3°C across chamber |
| Temperature Accuracy | ±0.1°C (at setpoint, calibrated at 37°C) |
| Power Supply | 220 V AC, 50 Hz |
| Drive System | Microprocessor-controlled brushless DC motor |
| Dimensions (W×D×H) | 670 × 620 × 1320 mm |
| Net Weight | 128 kg |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HZL-X160 |
| Price | USD 2,850 (FOB Jiangsu) |
| Instrument Type | Water-Jacketed Constant-Temperature Orbital Shaker / Incubator Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–300 rpm (adjustable in 1-rpm increments) |
| Orbit Diameter | 26 mm |
| Temperature Range | 5–60 °C (ambient ≤25 °C) |
| Shelf Configuration | Single-tier platform (dual-layer capacity via stackable flask racks) |
| Chamber Volume | 160 L |
| Max Flask Load | 40 × 250 mL Erlenmeyer flasks (standard dual-layer arrangement) |
| Control System | Microprocessor-based PID controller with digital display |
| Drive Mechanism | Brushless DC motor |
| Power Supply | 220 V AC, 50 Hz |
| External Dimensions (W×D×H) | 670 × 620 × 1320 mm |
| Temperature Uniformity | ±0.3 °C across chamber (at 37 °C, steady state) |
| Temperature Stability | ±0.1 °C (setpoint deviation under load) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ONLINE (IBR) |
| Pricing | Upon Request |
| Instrument Type | Online Real-Time Analyzer |
| Measurement Principle | Laser Light Absorption / Particle Shadow Imaging |
| Particle Size Range | 2–400 µm |
| Number of Adjustable Channels | 8 |
| Sensitivity Threshold | 2 µm |
| Resolution | ≤9% @ 2 µm, ≤5% @ 10 µm |
| Signal-to-Noise Ratio | 3:1 |
| Counting Efficiency | ≥50% @ 1 µm, 98% @ 1.5 µm, 99.9% @ 2 µm |
| Max Particle Concentration | 18,000 counts/mL |
| Coincidence Loss (at max concentration) | ≤10% |
| Flow Accuracy | ≤2% |
| Light Source | High-Stability Laser Diode |
| Sample Flow Rate | 60 mL/min (controlled via overflow tube & hydraulic pressure) |
| Flow Path Cleaning | Semi-Automatic Rinse |
| Sensor MTBF | 60,000–80,000 hours |
| Communication Interfaces | RS-485 (2-wire/4-wire), Modbus RTU, 4–20 mA analog output, custom protocols |
| Data Transmission Rate | 9600 bps |
| Output Modes | Cumulative count or time-segmented distribution |
| Maximum Display Value | 9,999,999 (cumulative) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QJICWQ |
| Price | USD 7,700 (FOB Shanghai) |
| Max. Torsion Angle | ±15° ±1° (Bidirectional) |
| Torque Measurement Range | Optional (Configurable per ISO/IEC 7816-1 & GB/T 16649.1) |
| Torque Resolution | 60 measurements/min |
| Angular Displacement Measurement Range | Optional (Programmable up to ±30°) |
| Motor Power | 35 W |
| Bending Speed | 29 rpm |
| Test Cycle Count Range | 1–9999 cycles |
| Dimensions (L×W×H) | 670 × 380 × 220 mm |
| Net Weight | 70 kg |
| Input Voltage | AC 220 V ±5%, 50 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICD-1 |
| Price Range | USD 7,000 – 14,000 |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ID Micro EA |
| Price Range | USD 140,000–280,000 |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer |
| Resolution | >75 at m/z 29 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CHQC-20 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Detection Range | Adjustable |
| Detection Time | 24 h |
| Throughput | Configurable |
| Sampling Frequency | Configurable |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VDH-01 |
| Pricing | Available Upon Request |
| Standard Compliance | IEC 62493:2015+A1:2021 |
| Frequency Range | 20 kHz – 10 MHz |
| Output Impedance | 50 Ω |
| Interface | BNC |
| Sensor Diameter | 210 mm |
| Cable Length | 300 mm |
| Weight | 1.7 kg |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | IF2000 |
| Pricing | Available Upon Request |
| Max Furnace Temperature | 1600 °C (Peak: 1650 °C) |
| Operating Temp Range | 200–1550 °C |
| Atmosphere Control | Oxidizing or Reducing |
| Sample Capacity | 2 crucibles per run |
| Temperature Resolution | 4 °C |
| Image Capture Interval | 5 °C |
| Compliance | ASTM D1857, ISO 540, DIN 51730, AFNOR M03-003, AS 1038.19 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | IFC-2 |
| Price | USD 690 (FOB Beijing) |
| Flow Rate Range | 5–25 L/min (continuously adjustable) |
| Timer Range | 0–99 minutes |
| Power Supply | AC 220 V / DC rechargeable battery (≥3 h continuous operation) |
| Dimensions | 210 × 130 × 90 mm |
| Explosion Protection | Intrinsic Safety “ib I” per GB 3836.4–2021 / IEC 60079-11 |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IGT C1, IGT C1-Orange, IGT G1-5, IGT F1 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 600MR |
| Pricing | Upon Request |
| Measurement Range | 0–1000 g |
| Resolution | 1 g |
| Test Duration | 5–999 s (user-adjustable) |
| Platform Dimensions | 18″ × 18″ |
| Animal Weight Capacity | 180–270 g (optimized for adult mice and small rats) |
| Input Method | Keypad + Optional Footswitch |
| Data Output | RS-232 Serial Interface, Optional Thermal Printer Support |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 390 or 390G (Capacity: 6 Rats or 12 Mice) |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MRBP-R01 |
| Pricing | Upon Request |