| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNGS-30 |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 50–250 rpm |
| Orbit Diameter | 30 mm |
| Load Capacity | 2 kg |
| Operating Temperature | 4–45 °C |
| Dimensions (W×D×H) | 284 × 264 × 90 mm |
| Input Voltage | AC 100–230 V |
| Power Supply Type | Universal voltage compatible |
| Motor Type | Brushless DC motor |
| Display | LED digital display for speed and timer |
| Platform Options | Interchangeable platforms (conical flask holder, adjustable flask rack, universal tray) |
| Platform Quantity | Up to 4 platforms (optional) |
| Brand | Hanuo |
|---|---|
| Origin | Zhejiang, China |
| Model | HNGYF-150D |
| Working Volume | 150 mL |
| Vessel Material | Stainless Steel (316L typical) |
| Operating Pressure Range | 0.1–12.5 MPa |
| Temperature Range | −10 °C to +100 °C |
| Ultrasonic Power Output | 10–500 W (continuously adjustable) |
| Vacuum Capability | 0.1–12.5 kPa (absolute) |
| Configuration | Jacketed dual-layer vessel with integrated ultrasonic transducer and titanium alloy sonotrode |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNGYF-150G |
| Working Volume | 150 mL |
| Maximum Pressure | 12.5 MPa |
| Temperature Range | Ambient to 300 °C |
| Vacuum Range | 0.1–12.5 kPa (absolute) |
| Construction Material | Stainless Steel (316L typical) |
| Ultrasonic Power Output | 10–500 W (continuously adjustable) |
| Transducer Type | Focused (probe-type) piezoelectric ultrasonic transducer with titanium alloy horn |
| Sealing Method | Dual-seal flange interface with high-temperature elastomer gasket |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNGYF-250D |
| Working Volume | 250 mL |
| Operating Pressure | Up to 12.5 MPa |
| Temperature Range | −10 °C to 100 °C |
| Ultrasonic Power Output | 20–1000 W (continuously adjustable) |
| Vacuum Capability | 0.1 MPa |
| Construction Material | Stainless Steel (316L grade typical) |
| Transducer Type | Titanium alloy sonotrode with focused ultrasonic energy delivery |
| Cooling/Heating Configuration | Double- or triple-jacketed vessel for precise thermal control |
| Sealing Method | Flanged ultrasonic transducer interface with metal gasket sealing |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNJD-0505L |
| Instrument Type | Constant-Temperature Bath Circulator |
| Temperature Range | −5 °C to 100 °C |
| Temperature Stability | ±0.05 °C |
| Bath Volume | 5 L |
| Circulation Mode | Internal Recirculation |
| Temperature Control | Dual-mode (Heating & Refrigeration) |
| Stirring Function | Integrated Magnetic Stirring System |
| Max. Stirred Vessel Capacity | 500 mL |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNJD-0505L |
| Temperature Range | −5 to 100 °C |
| Temperature Stability | ±0.1 °C |
| Bath Volume | 5 L |
| Circulation Mode | Internal & External |
| Temperature Control Type | Refrigeration & Heating |
| Max Stirring Capacity | 500 mL |
| Circulation Flow Rate | 6 L/min |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNLZ-10 |
| Oscillation Modes | Vertical & Tilt (0–22° adjustable) |
| Frequency Range | 10–300 cycles/min (vertical), 20–250 cycles/min (tilt) |
| Amplitude | 40 mm |
| Load Capacity | 2 × 13 kg (including fixtures) |
| Timer Range | 0–999 min |
| Noise Level | ≤55 dB(A) |
| Motor Type | Brushless DC Motor |
| Compatible Vessels | 150 mL, 250 mL, 500 mL, 1000 mL separatory funnels and stoppered bottles |
| Standard Fixtures | 10 pcs |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNM-800 |
| Heating Method | Infrared Radiant Heating |
| Max Operating Temperature | 825 °C ± 50 °C |
| Standby Temperature | 480 °C |
| Bore Diameter | φ14 mm |
| Heating Zone Length | 140 mm |
| Temperature Control Accuracy | ±1 °C |
| Temperature Uniformity (across heating zone) | ±50 °C |
| Rated Power | 200 W |
| Input Voltage | AC 220 V ± 10%, 50 Hz |
| Net Weight | 1.3 kg |
| External Dimensions (W×D×H) | 140 mm × 140 mm × 280 mm |
| Operating Ambient | 10–50 °C, ≤90% RH, uncontrolled altitude |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNM-800D |
| Instrument Type | Horizontal Benchtop Infrared Sterilizer |
| Maximum Operating Temperature | 825 °C ± 50 °C |
| Sterilization Chamber Diameter | 35 mm |
| External Dimensions | Not specified (compact benchtop unit) |
| Power Rating | 200 W |
| Net Weight | 1.5 kg |
| Input Voltage | AC 220 V ± 10 %, 50 Hz |
| Standby Temperature | 480 °C |
| Sterilization Time (typical) | 5–7 s |
| Compatible Tool Outer Diameter | ≤35 mm |
| Heating Zone Length | 100 mm |
| Operating Ambient Temperature | 10–50 °C |
| Relative Humidity Limit | ≤90 % RH |
| Altitude | Unrestricted |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HNM4-150 |
| Price | USD 1,800 (excl. VAT & shipping) |
| Chamber Diameter | Ø150 mm (customizable) |
| Arm Count | 4 |
| Desiccant Towers | 4 × 500 mL |
| Glass Reservoirs | 4 × 25 mL, 4 × 50 mL, 4 × 100 mL |
| Flowmeters | 4 precision glass rotameters |
| Tubing | 4 × medical-grade silicone tubing |
| Activated Carbon | 1 kg (replenishable) |
| Optional | Oil-free silent vacuum pump |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNMTC-100 |
| Oscillation Frequency | 300–1800 rpm |
| Oscillation Amplitude | 3 mm (horizontal rotation) |
| Temperature Range | −5°C to 100°C |
| Temperature Uniformity | ≤ ±0.3°C |
| Temperature Stability | ±0.3°C |
| Temperature Display Resolution | 0.1°C |
| Heating Rate | <15 min (20°C → 100°C) |
| Cooling Rate | ≥7°C/min (100°C → 20°C), ≥1.2°C/min (ambient → ambient −20°C at 30°C ambient) |
| Timer Range | 0–99 h 59 min, multi-step programming |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 8.3 kg |
| Standard Plate | 1 interchangeable module included |
| Optional Modules | A–N series (including 96-well PCR plates, 0.2–50 mL tube formats, deep-well plates, and custom cavities) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNMTH-100 |
| Instrument Type | Heated Vortex Mixer / Thermo-Shaker |
| Timer Range | 0–100 h |
| Oscillation Frequency | 300–2000 rpm |
| Oscillation Amplitude | 3 mm (horizontal orbital) |
| Temperature Range | RT + 5°C to 100°C |
| Temperature Uniformity | ≤ ±0.3°C |
| Temperature Stability | ±0.3°C |
| Temperature Display Resolution | 0.1°C |
| Heating Rate | <15 min (20°C → 100°C) |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 6.8 kg |
| Sample Platform | Single interchangeable block platform |
| Drive Motor | Brushless DC motor |
| Safety Features | Over-temperature protection, auto-restart after power interruption, short-pulse mixing mode |
| Calibration Function | Built-in temperature calibration |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNMTH-100 |
| Instrument Type | Heated Orbital Shaker / Incubating Mixer |
| Timer Range | 0–99 h 59 min, multi-segment programming |
| Oscillation Speed | 300–2000 rpm |
| Oscillation Amplitude | 3 mm (horizontal orbital) |
| Temperature Range | Ambient +5 °C to 100 °C |
| Temperature Uniformity | ≤ ±0.3 °C |
| Temperature Stability | ±0.3 °C |
| Temperature Display Resolution | 0.1 °C |
| Heating Rate | <15 min (20 °C → 100 °C) |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 6.8 kg |
| Platform | Single interchangeable plate (multiple well-format compatible) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNUV-II |
| UV Wavelength | 254 nm (optional 312 nm / 365 nm lamps) |
| Exposure Time Range | 0–999.9 min |
| Exposure Energy Range | 0–99.99 J |
| UV Source | Five 10 W low-pressure mercury lamps |
| Power Consumption | 60 W |
| Chamber Material | Stainless steel |
| Display | Touch-enabled Chinese LCD interface |
| Memory | Non-volatile storage for up to 9 user-defined time/energy protocols |
| Operating Environment | 5–35 °C, ≤80% RH, 220 V AC ±20%, 50 Hz |
| Compliance | Designed for routine molecular biology workflows under GLP-aligned lab practices |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNUV-II |
| Instrument Type | Darkroom-style UV Crosslinker |
| UV Wavelength | 254 nm |
| UV Lamp Configuration | Five 10 W low-pressure mercury lamps (total nominal output 50 W) |
| Exposure Time Range | 0.1–999.9 min (0.1 min resolution) |
| Exposure Energy Settings | 9 programmable and persistent energy presets |
| Exposure Time Settings | 9 programmable and persistent time presets |
| Display | Monochrome LCD with Chinese interface |
| Control Interface | Touch-sensitive keypad |
| UV Shielding View Window | Yes |
| Chamber Material | Stainless steel interior |
| Chamber Dimensions (L×W×H) | 340 × 260 × 150 mm |
| External Dimensions (L×W×H) | 360 × 340 × 310 mm |
| Power Supply | 220 V AC, 50 Hz |
| Compliance | Designed for laboratory use in nucleic acid immobilization, UV sterilization, and photochemical crosslinking applications per standard molecular biology workflows |
| Brand | Hanuo |
|---|---|
| Model | HNW-D-2 |
| Temperature Range | Ambient to 100°C |
| Heating Power | 500 W |
| Chamber Dimensions (W×D×H) | 300 mm × 160 mm × 130 mm |
| External Dimensions (W×D×H) | 490 mm × 250 mm × 190 mm |
| Temperature Uniformity | ≤ ±1.0°C |
| Temperature Stability (Fluctuation) | ≤ ±0.5°C |
| Temperature Resolution | 0.1°C |
| Origin | Shanghai, China |
| Brand | Hanuo |
|---|---|
| Model | HNW-S-4 |
| Temperature Range | Ambient to 100 °C |
| Heating Power | 1000 W |
| Chamber Dimensions (W×D×H) | 300 mm × 300 mm × 130 mm |
| External Dimensions (W×D×H) | 490 mm × 390 mm × 190 mm |
| Temperature Uniformity | ≤ ±1 °C |
| Temperature Fluctuation | ≤ ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Control System | Microprocessor-based PID with Digital LCD Display |
| Timer Function | Adjustable up to 99 hours 59 minutes |
| Optional Accessory | Magnetic Stirrer Integration |
| Construction | Cold-rolled steel housing with electrostatic powder coating |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNWD-1000 |
| Heating Method | Water Bath |
| Temperature Range | Ambient +5°C to 99°C |
| Temperature Stability | ≤±1°C |
| Sample Capacity | 12 positions |
| Tube Diameter Compatibility | 10–29 mm |
| Gas Flow Rate | 15 L/min |
| Heating Power | 1000 W |
| Maximum Vertical Travel | 200 mm |
| Max Operating Pressure | 200 kPa |
| Display Resolution | ±0.1°C |
| Temp Uniformity (@60°C) | ≤±1°C |
| Warm-up Time (40°C → 99°C) | ≤30 min |
| Dimensions (L×W×H) | 390×300×850 mm |
| Weight | 10 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNWH-500W |
| Ultrasonic Power | 500 W (continuously adjustable, 100–500 W) |
| Ultrasonic Frequency | 30 kHz (auto-tracking) |
| Nebulization Capacity | 5–10 L/h |
| Tank Volume | 1000 mL |
| Nebulizer Tip Material | Titanium Alloy |
| Operation Mode | Pulse or Continuous |
| Control Interface | 4.3-inch TFT Touchscreen |
| PC Connectivity | Optional |
| Vacuum Filtration Pump | Optional |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNX-1500 |
| Type | Orbital Microplate Shaker |
| Timing Range | 0–99 h 59 min or Continuous Mode |
| Speed Range | 300–1500 rpm (300–1000 rpm under full load) |
| Orbit Diameter | 3 mm |
| Platform Capacity | 4 standard microplates (96-well format) |
| Dimensions (W×D×H) | 284 × 264 × 121 mm |
| Weight | 6 kg |
| Drive System | Brushless DC Motor |
| Display | LED Digital Display |
| Alarm | Audible End-of-Timer Alert |
| Compliance | CE-marked for laboratory use in EU |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNX-1500 |
| Instrument Type | Microplate Orbital Shaker |
| Timer Range | 99 h 59 min |
| Oscillation Frequency | 300–1500 rpm (standard range: 300–1000 rpm under full load) |
| Oscillation Amplitude | 3 mm (orbital, horizontal rotation) |
| Capacity | 4 standard microplates (96-well or 384-well) |
| Dimensions (W×D×H) | 284 × 264 × 121 mm |
| Weight | 6 kg |
| Drive System | Brushless DC motor |
| Display | LED digital display |
| Alarm | Audible end-of-program alert |
| Power Supply | AC 220 V, 50 Hz |
| Certifications | CE-compliant design |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HNX-1500 |
| Price | USD 760 (est.) |
| Instrument Type | Microplate Shaker |
| Timer Range | 0–99 h 59 min |
| Oscillation Speed | 300–1500 rpm |
| Amplitude | 3 mm (orbital) |
| Temperature Control | None |
| Capacity | 4 standard microplates (e.g., 96-well, 384-well, 24-well, 48-well plates) |
| Dimensions | 284 × 264 × 121 mm |
| Weight | 6 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNX-2500P |
| Instrument Type | Benchtop Microplate Centrifuge |
| Function | General-purpose microplate centrifugation |
| Max RCF | 797 × g |
| Max Speed | 2500 rpm |
| Capacity | 2 standard microplates (96-well) or deep-well plates |
| Speed Range | 500–2500 rpm |
| RCF Range | 32–797 × g |
| Timer Range | 1–30 min |
| Noise Level | ≤55 dB(A) |
| Multi-step Programming | up to 5 segments |
| Cycle Repetition | up to 99 cycles |
| Auto Re-start After Power Failure | Yes |
| Imbalance Detection | Real-time dynamic monitoring with audible/visual alarm |
| Safety Features | Electronic lid lock, overspeed protection, self-diagnostic system |
| Motor | Brushless DC motor |
| Power Input | AC 220 V, 50–60 Hz |
| Max Power Consumption | 150 W |
| Dimensions (W×D×H) | 463 × 340 × 248 mm |
| Weight | 16 kg |
| Operating Environment | 0–35 °C, ≤70% RH |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HNX-2500P |
| Instrument Type | Benchtop Microplate Centrifuge |
| Function | Standard Microplate Centrifugation |
| Maximum RCF | 797 × g |
| Maximum Speed | 2500 rpm |
| Sample Capacity | 2 × 96-well PCR plates (or deep-well plates) |
| Operating Noise | ≤55 dB(A) |
| Speed Range | 500–2500 rpm |
| RCF Range | 32–797 × g |
| Timer Range | 1–30 min |
| Multi-step Programming | Up to 5 segments |
| Cycle Repetition | Up to 99 cycles |
| Auto Restart After Power Failure | Yes |
| Imbalance Detection | Real-time electronic monitoring with audible/visual alarm |
| Drive System | Brushless DC motor |
| Power Input | AC 220 V, 50–60 Hz |
| Max. Power Consumption | 150 W |
| Dimensions (W×D×H) | 463 × 340 × 248 mm |
| Weight | 16 kg |
| Ambient Operating Temperature | 0–35 °C |
| Relative Humidity | ≤70 % RH |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HSP1000 |
| Automation Level | Semi-Automatic |
| Sealing Temperature Range | 80–200 °C |
| Temperature Accuracy | ±1 °C |
| Sealing Time | 0.5–10.0 s (adjustable in 0.1 s increments) |
| Plate Height Accommodation | 9–48 mm |
| Max Input Power | 300 W |
| Dimensions (D×W×H) | 370 mm × 180 mm × 330 mm |
| Weight | 12 kg |
| Compatible Plate Types | Standard microplates (96-well, 384-well), PCR plates (full-skirted, half-skirted, non-skirted), deep-well storage plates, cell culture plates, ELISA plates |
| Compatible Plate Materials | Polypropylene (PP), Polystyrene (PS), Polyethylene (PE) |
| Compatible Sealing Films | Adhesive foil, thermal sealing film, pierceable thermal film, optical-grade transparent film (for qPCR) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HT856 |
| Instrument Type | Circulating Constant-Temperature Bath |
| Temperature Range | −5 °C to 100 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | ~10 L |
| Cooling/Heating Function | Yes |
| Circulation Mode | Internal Recirculation |
| Emissivity (Blackbody Cavity) | ≥0.99 |
| Sensor | Pt100 RTD |
| Control Algorithm | PID |
| Display | LCD |
| Ambient Operating Temperature | 0–40 °C |
| Power Supply | 220 VAC, 50 Hz |
| Compliance | JJF 1030–2010, JJG 856–2015 |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Type | Upright Ultra-Low Temperature Freezer |
| Model Designation | HU-40L (50 L capacity) |
| Rated Voltage | 220 V AC, 50 Hz |
| Rated Power | 350 W |
| Operating Temperature Range | –15 °C to –40 °C |
| Net Capacity | 50 L |
| External Dimensions (W×D×H) | 540 × 630 × 1080 mm |
| Internal Chamber Dimensions (W×D×H) | 360 × 405 × 405 mm |
| Net Weight | 70 kg |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HWS-150 |
| Capacity | 150 L |
| Temperature Range (with humidity active) | 0–50 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 30–95 %RH |
| Humidity Control Accuracy | ±2 %RH |
| Construction | Stainless steel interior chamber, triple-pane insulated glass door with mechanical lock |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HWS-600 |
| Capacity | 600 L |
| Temperature Range (with humidification) | 0–60 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 20–95 %RH |
| Humidity Control Accuracy | ±2 %RH |
| Door Configuration | Dual-door, triple-pane insulated glass |
| Interior Material | Stainless steel (AISI 304) |
| Compressor Type | Hermetic refrigeration system with delayed start and high/low pressure protection |
| Humidification Method | Ultrasonic humidifier |
| Air Circulation | Forced convection via stainless steel ducted airflow system |
| Safety Features | Over-temperature protection, sensor fault detection |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HWS-80 |
| Capacity | 80 L |
| Temperature Range (with humidification) | 0–50 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 30–95 %RH |
| Humidity Control Accuracy | ±2 %RH |
| Construction | Stainless steel interior, triple-pane insulated glass door, single-door configuration |
| Humidification Method | Ultrasonic humidifier |
| Cooling System | Hermetically sealed compressor with delayed start and high/low pressure protection |
| Air Circulation | Forced convection via stainless steel ducted airflow system |
| Safety Features | Over-temperature protection, sensor fault detection, door lock mechanism |