KANOMAX
Filter
Showing 391–420 of 500 results
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 μm |
| Measurement Range | 0.001–10.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1 V corresponding to 0–1000 CPM or 0–10,000 CPM |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Safety Classification | Non-explosion-proof |
| Compliance | Meets China’s Ministry of Health PM₁₀ monitoring requirements |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Optical Light Scattering (90° detection geometry) |
| Particle Size Range | 0.1–10 μm |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤ ±2% |
| Sampling Duration | Programmable from 10 to 3600 seconds (preset modes: 24 s and 120 s) |
| Data Storage Capacity | 500 records |
| Communication Interface | RS-232C compliant |
| Safety Classification | Non-explosion-proof |
| Compliance | Designed for indoor/outdoor ambient air quality monitoring per ISO 17025-aligned laboratory practices and compatible with GLP data integrity workflows |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3715-06D |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Max. Detectable Concentration | 2,000,000 counts/ft³ |
| Data Storage Capacity | 4,320 records |
| Communication Protocols | RS-485, Modbus RTU/TCP/IP |
| Power Options | DC 12–24 V, AC 100–240 V, PoE, or DC battery |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85 %RH (non-condensing) |
| Dimensions | 217 × 69 × 110 mm |
| Weight | 1.4 kg |
| Internal Vacuum Pump Lifetime | 8,000 h |
| MTBF | ≥10 years |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3715-06D |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Maximum Detectable Concentration | 2,000,000 counts/ft³ |
| Communication Protocols | RS-485, Modbus RTU/TCP/IP |
| Data Storage Capacity | 4,320 records |
| Power Supply Options | DC 12–24 V, AC 100–240 V, PoE, or external DC source |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Dimensions | 217 × 69 × 110 mm |
| Weight | 1.4 kg |
| Built-in Vacuum Pump Lifetime | 8,000 h |
| MTBF | ≥10 years |
| Display | 4.3-inch capacitive touchscreen |
| Status Indicators | Count, Flow, Laser, Alarm |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 3720-06 |
| Price | Upon Request |
| Particle Size Channels | Selectable 2–4 from 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (factory-configured |
| default | 0.5 & 5.0 µm) |
| Flow Rate | 28.3 L/min (1.0 CFM) |
| Light Source | Long-life Class II Laser Diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Maximum Detectable Concentration | 1,000,000 particles/ft³ |
| Data Storage | 5,000 full test records + 2,000 buffered measurements with redundancy backup |
| Housing Material | 316 Stainless Steel Enclosure with VHP- and ethanol vapor-resistant sealing |
| Vacuum Sampling Pump | Removable and serviceable |
| Power Supply | DC 15–28 V, PoE (IEEE 802.3af), or AC 100–240 V |
| Communication Interfaces | Ethernet (Modbus TCP/IP), RS-485 (Modbus RTU), 4–20 mA analog output |
| Alarm Output | Configurable ON/OFF per channel (0–100% threshold) |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Storage Conditions | −10–50 °C, ≤95% RH (non-condensing) |
| Dimensions | 180 × 110 × 190 mm |
| Weight | 4.0 kg |
| MTBF | ≥10 years |
| Warranty | 3 years |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3887D |
| Instrument Type | Handheld Particle Counter |
| Sampling Flow Rate | 2.83 L/min (0.1 cfm) |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0 µm |
| Data Storage Capacity | 7,000 records |
| Operating Interface | Chinese-language LCD display |
| Sampling Duration Range | 10 sec to 99 min 59 sec |
| Count Alarm Range | 1–70,000,000 particles per cubic foot |
| Power Supply | 4× AA Ni-MH rechargeable batteries (charger included) or AC adapter (100–240 V AC) |
| Dimensions | 108(W) × 68(D) × 196(H) mm |
| Weight | ~680 g (without batteries) |
| Compliance Standards | GB/T 16292–2010, ISO 14644-1:2015, China GMP (2010) Annex 1 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Handheld Particle Counter |
| Flow Rate | 2.83 L/min ±5% |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0 µm (3887Pro) |
| Display | 3.5-inch resistive touchscreen |
| Light Source | Laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Maximum Detectable Concentration | 2,000,000 particles/ft³ |
| Coincidence Loss | <5% at 2,000,000 particles/ft³ |
| Count Range | 1–70,000,000 counts |
| Sampling Modes | Single, Repeat, Continuous, Calculate, Remote, GB/T 16292, ISO 14644-1 |
| Data Storage Capacity | 7,000 sample records |
| Power | Rechargeable Li-ion battery (≈5 h operation) + USB-C AC adapter |
| Dimensions | 87 × 200 × 55 mm |
| Weight | ≈600 g |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3888, 3889, 3889-01 |
| Flow Rate | 2.83 L/min |
| Particle Size Channels | 0.3/0.5/5.0 µm (3888) |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Compliance | ISO 21501-4, JIS B9921, GB/T 16292–2010, Annex I of EU GMP Guidelines (2022), FDA Guidance for Aseptic Processing Environments |
| Data Storage | 10,000 sample records (CSV format) |
| Communication | Dual USB (Host/Device), RS485, Ethernet, Wi-Fi (via docking station) |
| Operating Temp. | 10–40 °C |
| RH | 0–85% non-condensing |
| Battery Life | Up to 5 h (single-test mode) |
| Weight | 650 g (body only, no battery) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3888 / 3889 |
| Sampling Flow Rate | 2.83 L/min |
| Detectable Particle Sizes | 0.3, 0.5, 5.0 µm (3888) or 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm (3889) |
| Light Source | Laser Diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Maximum Concentration | 2,000,000 particles/ft³ |
| Sampling Time Range | 6 sec – 99 min 59 sec |
| Sampling Modes | Single, Repeat, Continuous, Calculate, ISO, GB |
| Data Storage Capacity | 10,000 records (CSV format) |
| Communication Interfaces | Dual USB (Host/Device), RS485, Ethernet, WiFi |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 0–85 % RH (non-condensing) |
| Dimensions | 100 × 213 × 55 mm (W × H × D) |
| Weight | 650 g (body only, battery excluded) |
| Battery Life | Up to 5 hours (single-test mode) |
| Language Support | English, Chinese, Japanese, Spanish |
| Regulatory Compliance | ISO 21501-4, JIS B9921, GB/T 16292–2010, Annex 1 of EU GMP, FDA Guidance for Aseptic Processing |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | <1 particle per 5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Detectable Particle Sizes | 0.3, 0.5, 5.0 µm (Model 3888) |
| Maximum Concentration | 2,000,000 particles/ft³ |
| Sampling Duration | 6 sec–99 min 59 sec |
| Count Alarm Range | 1–9,999,999 |
| Compliance | ISO 21501-4, JIS B 9921, GB/T 16292-2010, Annex 1 of EU GMP, FDA Guidance for Aseptic Processing |
| Data Storage | 10,000 records (CSV format) |
| Communication | USB (Host & Device), RS485, Ethernet, Wi-Fi |
| Power | Dual 3.7 V / 2600 mAh rechargeable Li-ion batteries or AC adapter (100–240 V) |
| Battery Life | Up to 5 h (single-test mode) |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Dimensions | 100 × 213 × 55 mm (W × H × D) |
| Weight | 650 g (body only, excluding batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3888 / 3889 |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3888 / 3889 |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | <1 particle per 5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Particle Size Channels | 0.3, 0.5, 5.0 µm (3888) |
| Max Concentration | 2,000,000 particles/ft³ |
| Sampling Duration | 6 sec – 99 min 59 sec |
| Data Storage | 10,000 records (CSV) |
| Communication | Dual USB (Host/Device), RS485, Ethernet, WiFi |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Power | Rechargeable Li-ion battery (3.7 V, 2600 mAh), AC adapter (100–240 V) |
| Battery Life | ~5 h (single-test mode) |
| Dimensions | 100 × 213 × 55 mm (W × H × D) |
| Weight | 650 g (body only, no battery) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3905 |
| Flow Rate | 28.3 L/min |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | ≥50% ±20% at 0.3 µm (ISO 21501-4 compliant) |
| Repeatability | ≤±10% FS |
| Size Resolution | <15% at 0.3 µm (ISO 21501-4) |
| Maximum Concentration | 500,000 particles/ft³ |
| Sampling Time Range | 6 sec – 23 h 59 min 59 sec |
| Data Storage | 10,000 sample records (internal), USB-expandable |
| Display | 6.4-inch full-color touchscreen |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, FDA 21 CFR Part 11 (audit trail enabled), EU GMP Annex 1, JIS B 9921 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3905 |
| Flow Rate | 28.3 L/min |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm (simultaneous) |
| Counting Efficiency | 50 ± 20% @ 0.3 µm (ISO 21501-4 compliant) |
| Maximum Concentration | 500,000 particles/ft³ |
| Size Resolution | <15% @ 0.3 µm (ISO 21501-4) |
| Display | 6.4-inch full-color touchscreen |
| Data Storage | 10,000 measurement records (internal), USB-expandable |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, USP <788>, FDA 21 CFR Part 11 (audit trail enabled), EC GMP Annex 1, JIS B 9921 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3910 |
| Flow Rate | 50 L/min |
| Flow Accuracy | <1 particle/5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | <±30% FS |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm (simultaneous) |
| Counting Efficiency | 50±20% @ 0.3 µm (ISO 21501-4 compliant) |
| Max Concentration | 300,000 particles/ft³ |
| Size Resolution | <15% @ 0.5 µm (ISO 21501-4) |
| Zero Count | JIS-compliant |
| Data Storage | 10,000 sample records (expandable via USB drive) |
| Display | 6.4-inch true-color touchscreen |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, GB 50333–2013, EU GMP Annex 1, USP <788>, FDA 21 CFR Part 11 (audit trail enabled), JIS B 9921 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3910 |
| Flow Rate | 50 L/min |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | 50 ± 20% @ 0.3 µm (ISO 21501-4 compliant) |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | < ±30% FS |
| Timing Accuracy | ±1 s per 6-min sampling |
| Flow Accuracy | <1 particle deviation per 5 min |
| Data Storage | 10,000 sample records (expandable via USB drive) |
| Display | 6.4-inch true-color touchscreen |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, EU GMP Annex 1, US FDA 21 CFR Part 11 (audit trail enabled), JIS B 9921 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3920 |
| Flow Rate | 100 L/min |
| Simultaneous Channel Count | 6 |
| Detectable Particle Sizes | 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm |
| Compliance | ISO 14644-1, ISO 21501-4, USP <788>, FDA 21 CFR Part 11, GMP (2010), GB/T 16292–2010, EC GMP, British Standard BS EN ISO 14644 |
| Data Storage Capacity | 10,000 measurement records with geotagging (map coding) |
| Display | 6.4-inch full-color touchscreen |
| Power | Rechargeable Li-ion battery (dual-slot), AC 100–240 V |
| Weight | ~4.5 kg (without battery), ~5.0 kg (with battery) |
| Dimensions | 200 × 205 × 250 mm |
| Communication | USB, Ethernet, optional environmental sensor interface |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3920 |
| Flow Rate | 100 L/min |
| Particle Size Channels | 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (simultaneous) |
| Counting Efficiency | ≥50% ±20% at 0.5 µm (ISO 21501-4 compliant) |
| Maximum Concentration | 300,000 particles/ft³ |
| Repeatability | ≤±10% FS |
| Size Resolution | <15% at 0.5 µm (ISO 21501-4) |
| Flow Accuracy | <1 particle deviation per 5 min |
| Timing Accuracy | <±30% FS |
| Indication Error | <±30% FS |
| Data Storage | 10,000 measurement sets with geotagging (map coding) |
| Compliance | ISO 14644-1:2015, ISO 14644-2015, EU GMP Annex 1, USP <788>, FDA 21 CFR Part 11 (audit trail & electronic signature support), GB/T 16292–2010, GB 50333–2013, BS 5295, Federal Standard 209E |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3920 |
| Flow Rate | 100 L/min |
| Particle Size Channels | 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | ≥50% ±20% at 0.5 µm (ISO 21501-4 compliant) |
| Maximum Concentration | 300,000 particles/ft³ |
| Repeatability | ≤±10% FS |
| Flow Accuracy | <1 particle deviation per 5 min |
| Timing Accuracy | <±30% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | <±30% FS |
| Data Storage | 10,000 measurement sets with geotagging (map coding) |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, EU GMP Annex 1, USP <788>, FDA 21 CFR Part 11 (audit trail & electronic signature support), GB/T 16292–2010, GB 50333–2013, British Standard BS EN ISO 14644, Federal Standard 209E (repealed but referenced) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 µm, 0.3 µm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Display | 4.3" Color Touchscreen LCD |
| Communication | RS-485, Ethernet, USB (Host/Device) |
| Data Storage | Up to 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20–70°C (probe), 5–40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature) |
| Display | Dual-parameter (wind speed + temperature), battery level (4-segment), averaging mode (FAST/SLOW), unit toggle (m/s/°C ↔ fpm/°F), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm with sheath) × 205 mm |
| cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 30 mm |
| Weight | ~180 g (including batteries) |
| Compliance | Designed for ISO/IEC 17025-aligned environmental monitoring workflows, compatible with GLP documentation practices |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1.0 °C (temperature) |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20–70°C (probe), 5–40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature at 1 m/s) |
| Display | Dual-parameter (wind speed + temperature), unit switchable (m/s/°C ↔ fpm/°F), FAST/SLOW averaging, battery level indicator (4-segment), hold function |
| Dimensions (probe) | Ø6.1 mm (Ø10.6 mm at tip) × 205 mm |
| cable | Ø3.3 mm × ~1.5 m |
| Dimensions (main unit) | 60 × 120 × 30 mm |
| Weight | ~180 g (including batteries) |
| Compliance | Designed for ISO/IEC 17025-aligned environmental monitoring workflows, compatible with GLP documentation practices |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s) |
| Accuracy | ±5% of reading (wind speed) |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20–70°C (probe), 5–40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature) |
| Display | Dual-parameter (wind speed + temperature), selectable units (m/s/°C or fpm/°F), FAST/SLOW averaging, battery level indicator (4-segment), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm at tip) × 205 mm |
| Cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 30 mm |
| Weight | ~180 g (including batteries) |
| Compliance | Designed per JIS B 7554 and IEC 61260-1 Class 2 requirements for environmental air velocity instrumentation |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20–70°C (probe), 5–40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature) |
| Display Features | Battery level (4-segment), FAST/SLOW averaging (1 s / 5 s), unit toggle (m/s/°C ↔ fpm/°F), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm at tip) × 205 mm |
| cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 30 mm |
| Weight | ~180 g (including batteries) |
| Compliance | Designed for ISO 7726-compliant thermal environment assessment, suitable for HVAC commissioning and indoor air quality (IAQ) surveys per ASHRAE Standard 111 and EN 13790 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20–70°C (probe), 5–40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature) |
| Display | Dual-parameter (wind speed & temperature), 4-segment battery indicator, FAST/SLOW averaging (1 s / 5 s), unit toggle (m/s/°C ↔ fpm/°F), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm at tip) × 205 mm |
| cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 30 mm |
| Weight | ~180 g (incl. batteries) |
| Compliance | Designed for ISO 5801, ISO 17713, and ASTM D1076-compliant airflow verification in HVAC, cleanroom, and industrial hygiene applications |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20 to +70°C (air), 5 to 40°C (main unit), 0 to 50°C (probe) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature at 1 m/s) |
| Display | Dual-parameter (wind speed & temperature), unit switchable (m/s/°C ↔ fpm/°F), FAST/SLOW averaging, battery level indicator (4-segment), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm with sheath) × 205 mm |
| cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 34 mm |
| Weight | ~180 g (including batteries) |
| Storage Temperature | −10 to +50°C |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20–70°C (probe), 5–40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature) |
| Display | Dual-parameter (wind speed + temperature), unit switchable (m/s/°C ↔ fpm/°F), FAST/SLOW averaging, battery level indicator (4-level), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm tip) × 205 mm |
| Cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 30 mm |
| Weight | ~180 g (including batteries) |
| Accessories | Instruction manual, carrying case |
| Optional Accessories | Extension rod, spare probe |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Type | Thermal Anemometer |
| Model | 6006 |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (air velocity), ±1.0 °C (temperature) |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |