LabCompanion
Filter
Showing 301–330 of 483 results
| Brand | LabCompanion |
|---|---|
| Model | SA-45 / SA-60 |
| Temperature Range | RT to +200°C (SA-45) / RT to +300°C (SA-60) |
| Uniformity | ±0.5°C |
| Control Accuracy | ±0.3°C |
| Air Exchange Rate | 1–200 times/hour (selectable) |
| Turntable Speed | 8–10 rpm |
| Internal Dimensions (W×H×D) | 450×450×450 mm (SA-45) / 600×600×600 mm (SA-60) |
| Power Supply | 220 V, single-phase, 5 kW (SA-45) / 7 kW (SA-60) |
| Compliance Standards | ASTM D2436, D573 |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | SC-1000 |
| Sand Composition | 97–99% SiO₂ (silicon dioxide) |
| Sand Blowing Concentration | 1.1 g/m³ ±0.25 g/m³ to 2.2 g/m³ ±0.5 g/m³ |
| Sand Blowing Velocity | Adjustable from 1–10 m/s |
| Dust Concentration Control | 0.1–10.6 g/m³ ±7% with real-time monitoring and automatic dust replenishment |
| Internal Chamber Dimensions | 1000 × 1000 × 1000 mm (W×H×D) |
| External Dimensions | 1550 × 1800 × 1400 mm (W×H×D) |
| Power Supply | AC 380 V ±10%, 50 Hz |
| Total Power Consumption | 5 kW |
| Operating Ambient Temperature | −15 °C to +50 °C |
| Relative Humidity Range | 10–80% RH (at 20 °C) |
| Altitude Limit | Up to 3000 m |
| Compliance Standards | IEC 60529:2001, IEC 60068-2-68 (Test La2), GB 2423.37–2006, GB 4208–2008, DIN 40050-9, JIS D 0207, ISO 20653, SAE J575e, GB 10485 |
| IP Rating Validation | IP5X and IP6X |
| Dust Sieve Specifications | Wire diameter 50 µm, nominal mesh spacing 75 µm |
| Talcum Powder Loading | 2–4 kg/m³ |
| Test Duration Range | 0–99 h 59 min (programmable) |
| Data Logging | Battery-backed RAM storage ≥120 days (2-min sampling interval) |
| Interface | USB port for data export (CSV/Excel-compatible), PC software for test programming, curve visualization, and audit-trail-enabled reporting |
| Safety Features | Door interlock, over-temperature cut-off, phase-loss protection, leakage current protection, motor overload protection, vacuum system pressure monitoring, audible/visual fault alerts |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | Yes |
| Model | SC-800 |
| Sand Composition | 97–99% SiO₂ |
| Sand Blasting Concentration | 1.1 g/m³ ±0.25 g/m³ to 2.2 g/m³ ±0.5 g/m³ |
| Sand Blasting Velocity | 0–29 m/s |
| Dust Concentration | 0.1–10.6 g/m³ ±7 g/m³ |
| Dust Velocity | 8.9 m/s ±1.2 m/s |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH-60C / SH-90C / SH-120C / SH-160C / SH-200C |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1.0–2.0 mL/80 cm²/h (averaged over ≥16 h collection period) |
| Nozzle Pressure | 0.7–1.0 kgf/cm² |
| Fog Removal Method | Pneumatic Air-Compression Exhaust |
| Test Chamber Temp. | 35 °C ±1 °C (NSS) / 50 °C ±1 °C (CASS) |
| Saturated Air Chamber Temp. | 47 °C ±1 °C (NSS) / 63 °C ±1 °C (CASS) |
| Salt Solution Temp. | 35 °C ±1 °C (NSS) / 50 °C ±1 °C (CASS) |
| Chamber Volume | 108–1440 L |
| Salt Solution Tank Capacity | 15–40 L |
| NaCl Concentration | 5.0 wt% (NSS) or 5.0 wt% NaCl + 0.26 g/L CuCl₂·2H₂O (CASS) |
| Compressed Air Pressure | 1.00 ±0.01 kgf/cm² |
| Relative Humidity in Chamber | ≥85% RH |
| pH of Salt Solution | 6.5–7.2 (NSS) / 3.0–3.2 (CASS) |
| Power Supply | AC 220 V, 1-phase, 10–30 A (model-dependent) |
| Compliance | GB/T 2423.17, GB/T 2423.18, GB/T 10125, ASTM B117, JIS H8502, IEC 60068-2-11, CNS 4158/4159, GB/T 12967.3 |
| Brand | LabCompanion |
|---|---|
| Model | SH Series |
| Type | Environmental Test Chamber |
| Origin | Guangdong, China |
| Manufacturer | LabCompanion (Guangdong Hongzhan Instrument Co., Ltd.) |
| Compliance | GB/T 10586–1989, GB/T 2423.3–1993 (IEC 60068-2-3) |
| Temperature Range | R.T.+10 to 100 °C |
| Temp. Uniformity | ±2 °C |
| Temp. Fluctuation | ±0.5 °C |
| Humidity Range | 60–98% RH |
| Humidity Deviation | ±2 / −3% RH |
| Interior Dimensions (mm) | 400×450×650 / 500×550×700 / 700×800×900 |
| Interior Volume | ~100 L / ~200 L / ~500 L |
| Power Supply | 220 V, 50 Hz |
| Heating System | Ni-Cr Alloy Wire Heater |
| Humidification | Stainless Steel Sheathed Surface Evaporation Heater |
| Insulation | High-Density Polyurethane Foam + Glass Wool |
| Controller | Microcomputer-Based Fuzzy Logic PID Control with PT100 Sensors |
| Safety Protections | Dry-run protection for humidifier, independent overtemperature cutoff, low-water level detection, compressor overload/overcurrent protection, high-pressure refrigerant switch, circuit breaker, and earth leakage protection |
| Brand | LabCompanion |
|---|---|
| Model | SH Series |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Application | Corrosion Resistance Testing of Coated & Surface-Treated Materials |
| Compliance | ASTM B117, ISO 9227 (formerly ISO 3768/3769/3770), JIS Z 2371, JIS D 0201, K 5400, HB 8610 |
| Chamber Volume | 480 L / 270 L / 108 L (SH-120 / SH-90 / SH-60) |
| Test Temperature | 35 °C ±1 °C (Neutral Salt Spray) or 50 °C ±1 °C (Acidified Salt Spray) |
| Saturated Air Temperature | 47 °C ±1 °C or 63 °C ±1 °C |
| pH Range | 6.5–7.2 (NSS) or 3.0–3.2 (ASS/CASS) |
| NaCl Solution Concentration | 5.0 wt% ±0.1 wt% |
| Fog Deposition Rate | 1.0–2.0 mL/h/80 cm² |
| Relative Humidity in Chamber | >85% RH |
| Salt Solution Reservoir Capacity | 40 L / 25 L / 15 L |
| Power Supply | AC 220 V, 1-phase, 20 A / 15 A / 10 A |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH-60 / SH-90 / SH-110 / SH-130 / SH-160 / SH-200 |
| Temperature Range | RT + 10 °C to 55 °C |
| Test Temperatures | 35 °C ± 1 °C (NSS), 50 °C ± 1 °C (CASS) |
| Temp. Uniformity | ±2 °C |
| Temp. Stability | ±0.5 °C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Control Method | PID + PWM + SSR |
| Chamber Material | 8 mm PVC board with circumferential reinforcement |
| Saturated Air Tank | SUS#304 stainless steel |
| Heating Element | Stainless steel tubular heater |
| Viewing Window | Transparent acrylic lid |
| Drainage System | Front-mounted independent drainage ports |
| Safety Protection | Dual EGO + PT100 sensor, low-water cutoff, over-temp protection for chamber & saturator, over-current breaker |
| Fog Generation | Bernoulli-effect air-driven atomization |
| De-fogging System | Integrated post-test fog removal |
| Water Supply | Manual or auto-fill option |
| Compliance | ASTM B117, ISO 9227, JIS Z2371, CNS 4797, GB/T 2423.17 |
| Power Supply | 220 V / 380 V, 50 Hz |
| Volume Range | 100–1080 L |
| Brand | LabCompanion |
|---|---|
| Model | SH-60 / SH-90 / SH-110 / SH-130 / SH-160 / SH-200 |
| Origin | Guangdong, China |
| Manufacturer | LabCompanion (Guangdong Hongzhan Instrument Co., Ltd.) |
| Temperature Range | R.T. +10 °C to 55 °C |
| Test Temperatures | 35 °C ±1 °C (NSS), 50 °C ±1 °C (CASS) |
| Temp. Uniformity | ±2 °C |
| Temp. Stability | ±0.5 °C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Control Method | PID + PWM + SSR |
| Chamber Material | 8 mm PVC board with circumferential reinforcement |
| Saturated Air Tank | SUS#304 stainless steel |
| Heating Element | Stainless steel tubular heater |
| Chamber Cover | Transparent acrylic |
| Protection | Over-current breaker, chamber over-temp protection, saturated tank over-temp protection, low-water-level cutoff |
| Timer Range | 0–9999 h/min/sec (user-configurable) |
| Power Supply | 220 V/50 Hz or 380 V/50 Hz |
| Internal Volume | 100–1080 L |
| Compliance | ASTM B117, ISO 9227, JIS Z2371, CNS 12214 |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | Yes |
| Model | SH Series |
| Temperature Control Accuracy | ±0.5°C |
| Chamber Uniformity | ±1°C |
| Fog Deposition Rate | ±0.3 mL/80 cm²·h |
| Test Temperatures | 35±1°C / 50±1°C |
| Construction Material | PVC Board with Ring-Band Structural Reinforcement |
| Saturation Tower | Henry’s Law-Based Humidification |
| Spray Nozzle | Bernoulli-Principle Atomization |
| Low-Solution Alert | Yes |
| Fault Detection System | Visual & Audible Indication |
| Power Supply | 220 V, 1-phase |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH-110 |
| Construction Material | Imported corrosion-resistant, high-strength PVC/PP inner chamber |
| Sealing Method | Water-seal design (zero salt fog leakage) |
| Standard Accessories | One round-bar & one V-shaped sample rack, two nozzles, two funnels + calibrated collection cylinders |
| Safety Protections | Leakage current, short-circuit, over-temperature, low-water, end-of-test, and over-current protection |
| Power Supply | AC220V±10% 50Hz or AC380V±10% 50Hz |
| Operating Ambient | 5°C–30°C, ≤85% RH |
| Temperature Range | +5°C to 55°C |
| Temperature Uniformity | ≤±2°C |
| Temperature Fluctuation | ≤±0.5°C |
| Salt Fog Deposition Rate | 1–2 mL / 80 cm²·h |
| Spray Mode | Continuous or programmable cyclic spray |
| Timer Range | 1–999 hours (adjustable in seconds/minutes/hours) |
| Humidity Range (optional wet-salt mode) | 85–95% RH |
| Compliance | GB/T 2423.17, GB/T 10125–1997, GB/T 10587, ASTM B117, ISO 3768/3769/3770, DIN 50021, JIS Z 2371, MIL-STD-810, IEC 60068-2-11 |
| Brand | LabCompanion |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH-160 |
| Chamber Volume | 900 L |
| Internal Dimensions (L×W×D) | 1600 × 1000 × 900 mm |
| External Dimensions (L×W×D) | 1740 × 1140 × 1000 mm |
| Test Solution Capacity | 60 L |
| Temperature Control Accuracy | ±0.3 ℃ |
| Spray Method | Continuous & Programmable Cyclic Spray |
| Heating Method | Steam Direct Injection via Titanium Heater |
| Humidity Generation | Henry’s Law-Based Saturated Air Humidification in Pressure Tank |
| Nozzle Material | Precision Borosilicate Glass (≥4000 hr crystallization-free operation) |
| Control System | Digital PID Controller with Dual Over-Temperature Protection |
| Water Supply | Auto/Manual Refill with Low-Level Alarm |
| Fog Seal | Water-Lock Sealing Trough with Auto-Fill |
| Viewing Window | Auto-Demisting System |
| Lid Actuation | Pneumatic Cylinder-Assisted Lift |
| Timer Range | 0.01 s to 9999 h |
| Compliance | ASTM B117, ISO 9227, JIS Z2247, GB/T 2423.17 |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH-60 |
| Power | 1.3 kW |
| Temperature Range | +5°C to 55°C |
| Temp. Uniformity | ≤ ±2°C |
| Temp. Stability | ≤ ±0.5°C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Spray Mode | Continuous or Cyclic |
| Test Timer | 1–999 (s/min/h) adjustable |
| Chamber Dimensions (D×W×H) | 450×600×400 mm |
| External Dimensions (D×W×H) | 560×1140×1000 mm |
| Compliance | ASTM B117, ISO 9227, GB/T 2423.17, GB/T 10125, JIS Z 2371, DIN 50021, IEC 60068-2-11 |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH-60 |
| Temperature Range | R.T. +10 °C to 55 °C |
| Test Temp | 35 °C ±1 °C (NSS), 50 °C ±1 °C (CASS) |
| Temp. Uniformity | ±2 °C |
| Temp. Stability | ±0.5 °C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Spray Mode | Continuous or Cyclic |
| Timer Range | 0–9999 h/min/sec |
| Chamber Material | 8 mm PVC board with reinforced banding |
| Saturated Air Tank | SUS#304 stainless steel |
| Heating Element | Stainless steel tubular heater |
| Control System | PID + PWM + SSR, digital display, ±0.3 °C accuracy |
| Safety Protections | Overcurrent breaker, chamber overtemperature protection, saturated air tank overtemperature protection, low-water-level cutoff |
| Power Supply | 220 V/50 Hz or 380 V/50 Hz |
| Internal Volume | 100 L |
| Dimensions (W×D×H) | 600×450×400 mm (chamber) |
| Standard Accessories | Sample racks, calibrated collection funnel, glass nozzle, spray tower assembly, operation manual |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH-60 |
| Temperature Range | R.T. + 10 °C to 55 °C |
| Test Temperatures | 35 °C ± 1 °C (NSS), 50 °C ± 1 °C (CASS) |
| Temp. Uniformity | ±2 °C |
| Temp. Stability | ±0.5 °C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Control Method | PID + PWM + SSR |
| Chamber Material | 8 mm PVC board with ring-reinforced structure |
| Saturated Air Tank | SUS#304 stainless steel |
| Heating Element | Stainless steel tubular heater |
| Safety Protections | Over-current breaker, chamber over-temp protection, saturated tank over-temp protection, low-water-level cutoff |
| Compliance | ASTM B117, ISO 9227, JIS Z2243, CNS 12217 |
| Brand | LabCompanion |
|---|---|
| Model | SH-90 |
| Chamber Internal Dimensions (L×W×D) | 900 × 600 × 500 mm |
| External Dimensions (L×W×D) | 1600 × 860 × 1300 mm |
| Temperature Control Range | Ambient to 50°C |
| PID Temperature Accuracy | ±0.1°C |
| Heating Method | Direct Steam Injection |
| Saturated Air Tank | Henry’s Law-Based Humidification System |
| Nozzle Material | Precision Borosilicate Glass |
| Spray Uniformity | Conical Diffuser-Enhanced Distribution |
| Water Supply | Dual Auto/Manual Refill with Low-Level Alarm |
| Safety Features | Dual Over-Temperature Protection, Visual/Audible End-of-Test Alert, Vapor Seal via Water-Trough Lid Seal |
| Compliance Support | ASTM B117, ISO 9227, JIS Z2371, GB/T 2423.17 |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | SH-90 |
| Voltage | 220V/50Hz or 380V/50Hz |
| Chamber Material | Imported PVC rigid plastic board |
| Saturated Air Tank Material | SUS304 stainless steel |
| Heating Method | Direct steam heating |
| Temperature Control | Microcomputer PID controller with SSR output |
| Temperature Accuracy | ±0.1°C |
| Spray Nozzle | Precision PYREX glass nozzle |
| Spray Distribution | Conical disperser + adjustable fog settling rate |
| Safety Protections | Dual overtemperature protection (chamber & saturated air tank), low-water-level cutoff, overcurrent breaker |
| Compliance | GB/T 10587–2006, GB/T 2423.17–2008, IEC 60068-2-11:1987 |
| Internal Volume Options | 100 L to 1080 L |
| Power Consumption | 1.5 kW to 8 kW |
| Brand | LabCompanion |
|---|---|
| Model | SH+TH Series |
| Construction Material | SUS#316L inner chamber (1.0 mm), SUS#304 outer casing & saturation tank |
| Internal Dimensions (W×H×D) | 960 × 860 × 620 mm |
| Operating Temperature Range | –20 °C to +80 °C |
| Humidity Range | 25 %RH to 98 %RH |
| Temperature Control Accuracy | ±1 °C |
| Humidity Control Accuracy | ±2 %RH |
| Ramp Rate | 1 °C/min |
| Salt Fog Collection Rate | 1–2 mL/80 cm²/h |
| Control System | Japanese-made digital temperature/humidity programmable controller with LCD interface, integrated saturation tank controller (0–99.9 °C), timer (0–9999.9 hr), high-pressure recirculating pump |
| Program Capacity | Up to 99 steps per cycle, 99 cycles repeatable, individual step duration: 1 min to 99 h 59 min |
| Safety Protection | Comprehensive interlock system including over-temperature, over-pressure, low-water-level, and leakage detection |
| De-fogging System | Pneumatic air-pressure assisted fog exhaust |
| Compliance | Designed to meet ASTM B117, ISO 9227, JIS Z2371, and GB/T 2423.17 test method requirements |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH1-60 |
| Internal Dimensions (W×H×D) | 600 × 450 × 400 mm |
| External Dimensions (W×H×D) | 1070 × 600 × 1180 mm |
| Chamber Material | 5 mm imported gray-white PVC board |
| Pressure Vessel | Seamless welded 2.0 mm SUS201 stainless steel |
| Heating Element | Corrosion-resistant titanium heater tube |
| Temperature Control | DHC digital PID controller with platinum RTD sensor (±1 °C accuracy during salt spray test) |
| Humidity Control | Henry’s Law-based pressurized saturation chamber (≥95% RH) |
| Timer Range | 0.001 s – 999.9 h with power-failure memory and built-in 10-year battery backup |
| Spray Nozzle | Precision quartz glass nozzle (≥4000 h crystallization-free operation) with conical disperser for uniform fog distribution |
| Fog Collection | Integrated internal corrosion-resistant fog collector |
| Water Supply | Dual-mode automatic/manual refill system (auto-fill compatible with municipal water line) |
| Control Interface | Five-key tactile panel (Power, Operation, Spray, Timer, De-mist) with real-time fault diagnostics and LED status indicators |
| Sample Rack | 9.5 mm SUS304 stainless steel tubing (3 mm wall thickness), V-shaped plastic-steel support frame ensuring 30° specimen inclination |
| Structural Frame | SECC channel steel + angle iron, powder-coated finish, equipped with four swivel casters (mobile design applicable to SH1-120 and larger models) |
| Viewing Window | 5 mm imported transparent acrylic lid with high optical clarity and precision fabrication |
| Brand | LabCompanion |
|---|---|
| Model | SH15-90 |
| Origin | Guangdong, China |
| Manufacturer | LabCompanion (OEM/ODM Producer) |
| Chamber Internal Dimensions (W×D×H, mm) | 600×450×400 to 2000×900×600 |
| External Dimensions (W×D×H, mm) | 1080×800×1080 to 2700×1300×1550 |
| Internal Volume | 100–1080 L |
| Power Consumption | 1.5–8 kW |
| Supply Voltage | 220 V / 380 V, 50 Hz |
| Safety Protections | Overcurrent Circuit Breaker, Test Chamber Overtemperature Protection, Saturated Air Tank Overtemperature Protection, Low-Water-Level Cut-off |
| Standard Accessories | Sample Rack, Calibrated Graduated Cylinder, Fog Collection Funnel, Borosilicate Glass Nozzle, Spray Tower Assembly, User Manual |
| Optional Accessories | Oil-free Air Compressor, Additional Glass Nozzles |
| Brand | LabCompanion |
|---|---|
| Model | SHA |
| Origin | Guangdong, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Power Supply | AC220V±10% 50Hz or AC380V±10% 50Hz |
| Temperature Range | +5°C to 55°C |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Salt Spray Deposition Rate | 1–2 mL/80 cm²·h |
| Spray Mode | Continuous or Cyclic (adjustable) |
| Spray Duration | 1–9999 minutes/hours (SMH format) |
| Humidity Range (optional wet-salt mode) | 85–95% RH |
| Chamber Material | Imported corrosion-resistant, aging-resistant, high-strength PVC / PP / PC |
| Sealing Method | Water-seal design (zero salt fog leakage) |
| Compliance | GB/T 2423.17, GB/T 10125, IEC 60068-2-11, ASTM B117, ISO 9227, DIN 50021, JIS Z 2371, MIL-STD-810G |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Solar PV Series (PHP & PL Series) |
| Temperature Range | -40 °C to +100 °C |
| Humidity Range | 30–98 % RH |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Deviation | +2 % RH / −3 % RH (≥75 % RH), ±5 % RH (<75 % RH) |
| Internal Dimensions (D×W×H) | 1400×750×2350 mm to 1400×2550×2350 mm |
| Sample Capacity | 3–12 standard PV modules (up to 1000×50×2000 mm) |
| Controller | TEMI300 (Korean) or Japanese touchscreen PID controller |
| Refrigerant | R404A/R23 |
| Cooling Method | Water-cooled |
| Power Supply | 380 V, 50 Hz, 3-phase 5-wire |
| Compliance | IEC 61215:2005, IEC 61646:2008, GB/T 2423.3–2016, GB/T 10586–2018, GB/T 10592–2008 |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SP-1000U |
| Pricing | Upon Request |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-120U |
| Internal Volume | 120 L |
| Internal Dimensions (W×H×D) | 500 × 600 × 400 mm |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 10 %RH to 98 %RH (with optional dehumidification module) |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤ ±2.0 °C |
| Humidity Deviation | ±2.5 %RH |
| Heating Rate | −70 °C → +150 °C in ≤60 min (~3 °C/min) |
| Cooling Rate | +20 °C → −70 °C in ≤90 min (~1.2 °C/min) |
| Control System | ETAC820 Touchscreen PLC-based Controller (50 programs / 2500 segments) |
| Refrigerant | R507 (HFC, ozone-friendly) |
| Construction | SUS304 stainless steel interior & exterior with powder-coated cold-rolled steel option |
| Insulation | High-density polyurethane foam + glass fiber |
| Safety Protections | Dry-heater cutoff, independent over-temperature cutoff, low-water detection, compressor overload/overcurrent, high-pressure refrigerant switch, earth-leakage protection |
| Power Supply | AC220±10% V / 50±0.5 Hz (single-phase) or AC380±10% V / 50±0.5 Hz (three-phase) |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-120U |
| Internal Volume | 120 L |
| Internal Dimensions (W×H×D) | 500 × 600 × 400 mm |
| Temperature Range | −70 to +150 °C |
| Humidity Range | 10–98% RH (with optional dehumidification module) |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤ ±2.0 °C |
| Humidity Deviation | ±2.5% RH |
| Heating Rate | −70 → +150 °C in ≤60 min (~3 °C/min) |
| Cooling Rate | +20 → −70 °C in ≤90 min (~1.2 °C/min) |
| Refrigerant | R507 (HFC-based, ozone-safe) |
| Control System | ETAC820 Touchscreen PLC Controller (50 programs, 2500 segments) |
| Compliance | GB/T 10586, GB/T 10592, GB/T 2423.1/3/4/34, MIL-STD-810D, GJB 150.9, IEC 60068-2-3 |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-120U |
| Internal Volume | 120 L |
| Internal Dimensions (W×H×D) | 500 × 600 × 400 mm |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 10 %RH to 98 %RH (with optional dehumidification module) |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤ ±2.0 °C |
| Humidity Deviation | ±2.5 %RH |
| Heating Rate | −70 °C → +150 °C in ≤60 min (~3 °C/min) |
| Cooling Rate | +20 °C → −70 °C in ≤90 min (~1.2 °C/min) |
| Control System | ETAC820 Touchscreen PLC-Based Controller (50 programs, 2500 segments) |
| Refrigerant | R507 (HFC-based, ozone-safe) |
| Construction | SUS304 Stainless Steel Interior & Exterior |
| Insulation | High-Density Polyurethane Foam + Glass Fiber |
| Compressor | Imported Sealed Rotary Compressor (EU/US Origin) |
| Humidification | Stainless Steel UL-Type Steam Generator |
| Data Interface | LAN (SCADA/IPC-compatible), USB 2.0 Port |
| Safety Protections | Dry-run protection for humidifier, independent overtemperature cutoff, water shortage detection, compressor overcurrent/overpressure protection, earth leakage circuit breaker, thermal fuse |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-408 |
| Internal Volume | 408 L |
| Internal Dimensions (H×W×D) | 850×600×800 mm |
| External Dimensions (H×W×D) | 1100×1780×1250 mm |
| Temperature Range | −40 °C to +150 °C |
| Humidity Range | 20 %RH to 98 %RH |
| Temperature Uniformity | ±0.5 °C |
| Humidity Uniformity | ±1.0 %RH |
| Heating Rate | −70 °C to +150 °C in <90 min |
| Cooling Rate | +20 °C to −40 °C in <60 min |
| Control Method | BTHC (Balanced Temperature and Humidity Control) |
| Sensor Type | PT100 Dry/Wet Bulb Sensors |
| Heating System | Nickel-Chromium Alloy Wire Heaters |
| Humidification System | Shallow-Tank Electric Heater Type |
| Refrigeration System | Hermetic Twin-Screw Compressor (Tecumseh, Eco-Friendly Refrigerant R404A/R23) |
| Controller | TEMI Touchscreen HMI (Korea) |
| Insulation | Rigid Polyurethane Foam + Glass Wool |
| Inner Chamber Material | Mirror-Finished Stainless Steel (SUS304) |
| Outer Chamber Material | Powder-Coated Steel or Stainless Steel |
| Safety Protections | Compressor Overheat/Overcurrent/High-Pressure, Dry-Burn Prevention, Over-Temperature Alarm, Low-Water Level Alert, Circuit Isolation for Humidification Lines |
| Power Supply | 3φ5W 380 VAC ±10 % or 2φ3W 220 VAC ±10 % |
| Standard Accessories | Fluorescent Illuminated Viewing Window, φ50 mm Cable Port (Left Side), Two Adjustable Sample Racks, Castor Wheels, Integrated Water Reservoir (Rear-Mounted) |
| Optional | RS-485 Interface, Data Logger, Inner Glass Door with Glove Ports |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | SST-90 |
| Internal Chamber Dimensions | 600 × 450 × 400 mm (L×W×H) |
| Chamber Volume | 108 L |
| Salt Solution Tank Capacity | 15 L |
| Test Temperature | NSS/ACSS: 35 ±1 °C |
| CASS | 50 ±1 °C |
| Pressure Tank Temperature | NSS/ACSS: 47 ±1 °C |
| CASS | 63 ±1 °C |
| Salt Solution Temperature | 35 ±1 °C |
| Salt Concentration | 5% NaCl (w/v) or 5% NaCl + 0.26 g CuCl₂·2H₂O per liter |
| Compressed Air Pressure | 1.00 ±0.01 kgf/cm² |
| Fog Output Rate | 1.0–2.0 mL / 80 cm² / h |
| 雾喷雾 Mode | Continuous |
| Power Supply | AC 220 V, 50 Hz, 10 A |
| Heating Element | Corrosion-Resistant Titanium Tube |
| Control System | Digital PID Temperature Controller with ±0.3 °C Accuracy |
| Timer Range | 0.01 s to 999 h, Programmable Segment Timing & Countdown Mode |
| Safety Features | Dual Over-Temperature Protection, Auto-Cut-Off, Water-Level Monitoring with Visual/Audio Alert |
| Chamber Material | Reinforced PVC Board with Acid-Alkali Resistance & Thermal Stability |
| Nozzle | Precision Borosilicate Glass Nozzle (Rated >100,000 h Service Life) |
| Humidification | Henry’s Law-Based Saturated Air Humidification in Pressure Tank |
| Sealing | Water-Seal Fog Containment Trough with Auto-Replenishment |
| Exhaust Interface | Ø50 mm Outlet for External Ventilation Ducting |
| Chamber Door | Pneumatic Cylinder-Assisted Lift Mechanism |
| Optional De-Misting System | Integrated Post-Test Fog Extraction Module (Requires External Duct Connection) |
| Brand | LabCompanion |
|---|---|
| Model | STS-A / STS-B / STS-C / STS-D |
| Temperature Range Options | −60 °C to +150 °C |
| Shock Configuration | Dual-Zone (Low/High) or Triple-Zone (Low/Ambient/High) |
| Temperature Recovery Time | ≤ 5 min |
| Control System | Microprocessor-Based Programmable Controller with LCD Display |
| Internal Dimensions (W×D×H, cm) | STS-A: 40×35×30 |
| STS-B | 50×40×40 |
| STS-C | 60×50×50 |
| STS-D | 70×60×60 |
| External Dimensions (W×D×H, cm) | STS-A: 135×150×180 |
| STS-B | 155×152×190 |
| STS-C | 168×162×200 |
| STS-D | 178×172×210 |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | T-150-5 |
| Price Range | USD 14,000 – 28,000 (FOB) |
| Temperature Range | -70 °C to +150 °C |
| Cooling Method | Compressor-Based Refrigeration |
| Explosion-Proof Design | Standard (Non-Explosion-Proof) |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Deviation | ±2.0 °C |
| Heating Rate | 5.0 °C/min |
| Cooling Rate | 5.0 °C/min |
| Internal Chamber Dimensions | 500 mm × 600 mm × 500 mm (W×H×D) |
| Brand | LabCompanion |
|---|---|
| Model | T-150 / T-225 / T-408 / T-800 / T-1000 |
| Temperature Range | -70 °C to +150 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ≤ ±1.5 °C (standard models), ≤ ±2 °C (T-800/T-1000) |
| Temperature Accuracy | ±0.1 °C to ±0.3 °C |
| Heating Rate (20 °C → +150 °C, no-load, nonlinear) | ~3.0 °C/min (T-150–T-408), ~2.5 °C/min (T-800/T-1000) |
| Cooling Rate (20 °C → -70 °C, no-load, nonlinear) | ~1.2 °C/min (T-150–T-408), ~1.0 °C/min (T-800/T-1000) |
| Internal Volume | 150 L, 225 L, 408 L, 800 L, 1000 L (customizable) |
| Refrigerant | R404A (ozone-friendly, non-CFC) |
| Control System | 7-inch color touchscreen interface with AI-enhanced thermal field compensation algorithm |
| Programmability | Up to 100 user-defined test profiles |
| Data Traceability | Network-enabled data logging, exportable CSV/Excel reports, audit-ready for GLP/GMP environments |
| Compliance | Fully aligned with GB/T 2423.1, GB/T 2423.2, IEC 60068-2-1, IEC 60068-2-2, ISO 16750-4, and GJB 150A-2009 |