Labthink
Filter
Showing 61–90 of 497 results
| Brand | Labthink |
|---|---|
| Model | C230H |
| Measurement Principle | Coulometric Sensor + Isobaric Method |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 0% RH, 5–90% RH ±1% RH, 100% RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L (optional) |
| Carrier Gas | ≥99.999% high-purity N₂, inlet pressure ≥0.28 MPa |
| Data Management | DataShield™ audit-trail-enabled software |
| Regulatory Support | Optional 21 CFR Part 11 compliance package |
| GMP/Computer System Validation Support | Optional |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | C230H |
| Test Principle | Isobaric Method with Coulometric Oxygen Sensor |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015 |
| Measurement Range | 0.01–200 cm³/(m²·day) [film], 0.0007–12.9 cc/(100 in²·day), 0.00005–1 cm³/(pkg·day) [package] |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Test Temperature | 10–55 °C ±0.2 °C |
| RH Control | 0%, 5–90% ±1% (O₂ side), 100% RH option |
| Carrier Gas Humidity | 0%, 5–90% ±2% (optional) |
| Sample Area | 50 cm² |
| Max Sample Size | 108 mm × 108 mm |
| Max Thickness | ≤3 mm |
| Test Chamber Count | 3 |
| Package Testing Capacity | Up to 3 L |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Modules | DataShield™ Audit Trail, CFR 21 Part 11 Compliance, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | C230H |
| Principle | Isobaric Coulometric Sensor Method (ASTM D3985 compliant) |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2% (whichever is greater) |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 0% RH, 5–90% RH (±1% RH), 100% RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L (optional) |
| Carrier Gas | ≥99.999% N₂, ≥0.28 MPa (40.6 psi) |
| Interface | 1/8″ stainless steel tubing |
| Data Compliance | CFR 21 Part 11, GMP-ready, DataShield™ audit-trail enabled |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Labthink C230H OTR Tester |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Coulometric Oxygen Sensor + Isobaric Method |
| Standards Compliance | ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 0% RH, 5–90% RH ±1% RH, 100% RH |
| Test Chambers | 3 independent chambers |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Sample Thickness | ≤3 mm |
| Package Testing Capacity | Up to 3 L (optional) |
| Carrier Gas | ≥99.999% high-purity N₂, inlet pressure ≥0.28 MPa (40.6 psi) |
| Interface | 1/8″ stainless steel tubing |
| Data Management | DataShield™ audit-trail-enabled software with CFR 21 Part 11 support (optional) |
| Operating System | Windows 10 on 12″ capacitive touchscreen |
| Connectivity | Ethernet, Wi-Fi (optional), third-party API integration supported |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic |
| Model | C230H |
| Pricing | Upon Request |
| Test Principle | Coulometric Oxygen Sensor + Isobaric Method |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927 (optional), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015 |
| Film OTR Range | 0.01–200 cm³/(m²·day) |
| Container OTR Range | 0.00005–1 cm³/(pkg·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Test Temperature | 10–55 °C (±0.2 °C) |
| RH Control | 0%, 5–90% (±1%), 100% (O₂ side) |
| Test Chambers | 3 independent chambers |
| Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Standard Test Area | 50 cm² |
| Carrier Gas | ≥99.999% high-purity N₂ (user-supplied) |
| Inlet Pressure | ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Max Container Volume | 3 L (optional) |
| DataShield™ Data Integrity Module | Optional |
| GMP-Compliant Software & Audit Trail | Optional |
| 21 CFR Part 11 Compliance Support | Optional |
| Brand | Labthink |
|---|---|
| Model | C230H |
| Test Principle | Isobaric Method with Coulometric Oxygen Sensor |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 0% RH, 5–90% RH (±1% RH), 100% RH |
| Test Chambers | 3 independent |
| Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Standard Test Area | 50 cm² |
| Carrier Gas | ≥99.999% high-purity N₂ (user-supplied) |
| Gas Inlet Pressure | ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Features | Package testing (up to 3 L), DataShield™ Data Integrity System, CFR 21 Part 11 compliance package, GMP-compliant computer system validation support |
| Brand | Labthink |
|---|---|
| Model | C230H |
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Isobaric Method with Coulometric Oxygen Sensor |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927 (optional), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.01–200 cm³/(m²·day) [film] |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 0–90% RH (±1% RH), 100% RH (optional) |
| Test Chambers | 3 independent chambers |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L |
| Carrier Gas | ≥99.999% high-purity N₂ |
| Inlet Pressure | ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Features | DataShield™ Data Integrity System, CFR 21 Part 11 Compliance Module, GMP Computer System Validation Support, Package Testing Mode |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Labthink C230H |
| Price Range | USD 14,000 – 85,000 |
| Brand | Labthink |
|---|---|
| Model | C230H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Coulometric Sensor + Isobaric Method (ASTM D3985) |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 0% RH, 5–90% RH (±1% RH), 100% RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L (optional) |
| Carrier Gas | ≥99.999% N₂, ≥0.28 MPa (40.6 psi) |
| Interface | 1/8″ stainless steel tubing |
| Data Compliance | Optional 21 CFR Part 11, GMP-compliant audit trail, DataShield™ secure data management |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | C230H |
| Price Range | USD 14,000 – 70,000 |
| Test Principle | Isobaric Coulometric Oxygen Sensor Method (ASTM D3985 compliant) |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Temp Control | 10–55 °C ±0.2 °C |
| RH Control | 0%RH, 5–90%RH ±1%RH, 100%RH |
| Sample Capacity | 3 cavities |
| Max Package Volume | 3 L |
| Standard Test Area | 50 cm² |
| Specimen Size | 108 mm × 108 mm |
| Max Thickness | ≤3 mm |
| Carrier Gas | ≥99.999% N₂, ≥0.28 MPa |
| Interface | 1/8″ stainless steel tubing |
| Data Compliance | Optional 21 CFR Part 11, GMP audit trail, DataShield™ secure export |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | C230H |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Isobaric Method with Coulometric Oxygen Sensor |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 0% RH, 5–90% RH (±1% RH), 100% RH |
| Test Area | 50 cm² |
| Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Chamber Count | 3 |
| Package Testing Capacity | Up to 3 L (optional) |
| Carrier Gas | ≥99.999% N₂, ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Data Management | DataShield™ audit-trail-enabled software |
| Regulatory Support | Optional 21 CFR Part 11 compliance package |
| OS | Windows 10 on 12″ industrial touchscreen |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Labthink-C230H |
| Price Range | USD 14,000 – 70,000 |
| Test Principle | Isostatic (Equal-Pressure) Method with Coulometric Oxygen Sensor |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range (Film) | 0.01–200 cm³/(m²·day) |
| Test Range (Package) | 0.00005–1 cm³/(pkg·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 0% RH, 5–90% RH ±1% RH, 100% RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Package Volume | 3 L |
| Sample Size | 108 mm × 108 mm |
| Max. Sample Thickness | ≤3 mm |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Modules | DataShield™ Data Integrity System, CFR 21 Part 11 Compliance Package, GMP Computer System Validation Support, Package Testing Kit |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | C230H |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Coulometric Oxygen Sensor + Isostatic (Equal-Pressure) Method |
| Standards Compliance | ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.01–200 cm³/(m²·day) (film) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2% (whichever is greater) |
| Test Temperature | 10–55 °C ±0.2 °C |
| Test Humidity | 0% RH, 5–90% RH ±1% RH, 100% RH |
| Chamber Count | 3 |
| Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Standard Test Area | 50 cm² |
| Carrier Gas | ≥99.999% high-purity N₂ (user-supplied) |
| Inlet Pressure | ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Modules | Package Testing (up to 3 L), DataShield™ Data Integrity System, CFR 21 Part 11 Compliance Package, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | C303H |
| Measurement Principle | Infrared Detection (ASTM F1249, ISO 15106-2 compliant) |
| Test Range | Standard WVTR range for high-to-medium barrier films |
| Sample Types | Flexible packaging films, laminates, coated papers, pharmaceutical blister foils, PV encapsulation films |
| Compliance | GB/T 26253, ASTM F1249, ISO 15106-2, ISO 2528 |
| Data Output | Real-time WVTR (g/m²·day), permeability coefficient, temperature & RH control logging |
| Environmental Control | Dual-zone temperature and relative humidity regulation |
| Sensor Type | High-stability infrared moisture sensor with auto-zero calibration |
| Throughput | Up to 3 simultaneous test stations (configurable) |
| Interface | Ethernet + USB |
| Software | Labthink TRS v4.2 with 21 CFR Part 11 compliance mode, audit trail, user permission levels |
| Brand | Labthink |
|---|---|
| Model | C303H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Infrared Detection per ASTM F1249 & ISO 15106-2 |
| Test Area | 50 cm² (standard), optional 5 cm² or 1 cm² MASK fixtures |
| WVTR Range | 0.02–40 g/(m²·day) (50 cm²), 0.2–400 g/(m²·day) (5 cm²), 1–2000 g/(m²·day) (1 cm²) |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (standard), 5–60 °C (custom) |
| Temp Stability | ±0.05 °C |
| RH Range | 5–90 %RH ±2 %RH |
| Chamber Configuration | Triple independent test chambers |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Thickness | 3 mm |
| Carrier Gas | 99.999% N₂ (user-supplied) |
| Gas Inlet | 1/8″ stainless steel tube |
| Power | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions | 600 × 500 × 700 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C303H |
| Measurement Principle | Infrared Detection (ASTM F1249 / ISO 15106-2) |
| Test Range | 0.02–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 15–50 °C (±0.05 °C stability) |
| RH Control | 5–90 %RH (±2 %RH) |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Thickness | 3 mm |
| Carrier Gas | 99.999% N₂ (user-supplied, ≥280 kPa) |
| Power | 120/220 VAC, 50/60 Hz |
| Dimensions | 600 × 500 × 700 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C303H |
| Measurement Principle | Infrared Detection (ASTM F1249, ISO 15106-2 compliant) |
| Test Range | 0.005–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 15–50 °C (±0.05 °C stability) |
| RH Control | 5–90 %RH (±1 %RH) |
| Test Chambers | 3 independent chambers (50 cm² standard area each) |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Carrier Gas | 99.999% N₂ (user-supplied, ≥280 kPa) |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions | 600 × 500 × 700 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C303H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Range | 0.005–40 g/(m²·day) (50 cm²), 0.005–100 g/(m²·day) (50 cm²), 0.05–400 g/(m²·day) (5 cm² mask), 0.25–2000 g/(m²·day) (1 cm² mask) |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (standard), optional 5–60 °C |
| Temp. Stability | ±0.05 °C |
| RH Range | 5–90 %RH ±1 %RH |
| Test Area | 50 cm² (standard), 5 cm² / 1 cm² (optional masks) |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Thickness | 3 mm |
| Carrier Gas | ≥99.999% N₂, ≥280 kPa inlet pressure |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions | 600 × 500 × 700 mm |
| Weight | 100 kg |
| Compliance | ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015 |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Measurement Principle | Infrared Detection (ASTM F1249, ISO 15106-2) |
| Test Range | 0.02–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 15–50 °C (optional: 5–60 °C), stability ±0.15 °C |
| RH Control | 5–90 %RH ±2% |
| Test Chambers | 6 independent chambers |
| Standard Test Area | 50 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Sample Thickness | 3 mm |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥280 kPa |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions (W×D×H) | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Measurement Principle | Infrared Absorption Spectroscopy (ASTM F1249 / ISO 15106-2) |
| Test Range | 0.02–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (optional: 5–60 °C) |
| Temp. Stability | ±0.15 °C |
| RH Range | 5–90 %RH ±2% (at standard temp.) / 100 %RH |
| Test Area | 50 cm² (standard), optional 5 cm² or 1 cm² MASKs |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Thickness | 3 mm |
| Carrier Gas | ≥99.999% N₂, ≥280 kPa inlet pressure |
| Power Supply | 120 VAC ±10% 60 Hz or 220 VAC ±10% 50 Hz |
| Dimensions | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Measurement Principle | Infrared Detection of Water Vapor |
| Standards Compliance | ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015 |
| Test Area | 50 cm² (standard), optional 5 cm² or 1 cm² MASK fixtures |
| WVTR Range | 0.02–40 g/(m²·day) [50 cm²], 0.2–400 g/(m²·day) [5 cm²], 1–2000 g/(m²·day) [1 cm²] |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (standard), 5–60 °C (optional) |
| Temp. Stability | ±0.15 °C |
| Humidity Range | 100% RH, or 5–90% RH ±2% RH |
| Test Chambers | 6 independent |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Carrier Gas | 99.999% N₂, ≥280 kPa inlet pressure |
| Power Supply | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz |
| Dimensions | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 57,000 |
| Test Principle | Infrared Detection (ASTM F1249, ISO 15106-2) |
| Test Range | 0.02–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (optional: 5–60 °C) |
| Temp. Stability | ±0.15 °C |
| RH Range | 5–90 %RH ±2% (at standard temp.) / 100 %RH |
| Chamber Count | 6 independent test chambers |
| Standard Test Area | 50 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Carrier Gas | 99.999% N₂ (user-supplied) |
| Gas Inlet Pressure | ≥280 kPa |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions (W×D×H) | 600 mm × 490 mm × 660 mm |
| Net Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Range | 0.02–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Temperature Range | 15–50 °C (±0.15 °C stability) |
| Humidity Range | 5–90 %RH (±2 %RH) |
| Test Area | 50 cm² (standard), optional 5 cm² or 1 cm² MASK fixtures |
| Chamber Configuration | 6 independent test cells |
| Carrier Gas | 99.999% N₂ |
| Power Supply | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz |
| Dimensions | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90% RH ±1% RH (with optional 100% RH capability) |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L (optional) |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| Inlet Pressure | ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Compliance | ISO 15106-3, ASTM F3299, GB/T 21529, YBB 00092003–2015 |
| Optional Features | DataShield™ Data Integrity System, CFR 21 Part 11 Compliance Module, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Measurement Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 5–90% RH (±1% RH), optional 100% RH |
| Test Chambers | 3 independent chambers |
| Standard Test Area | 50 cm² |
| Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | 3 mm |
| Package Testing Capacity | up to 3 L |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Compliance | ISO 15106-3, ASTM F3299, GB/T 21529, YBB 00092003-2015 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | C330H |
| Quotation | Upon Request |
| Test Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90 %RH ±1 %RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² |
| Max Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Package Testing | Optional (up to 3 L) |
| Data Management | DataShield™ Audit-Trail Enabled |
| Compliance Options | 21 CFR Part 11, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Origin | Shandong, China |
| Manufacturer | Labthink Co., Ltd. |
| Test Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| RH Control | 5–90% RH (±1% RH), optional 100% RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Package Volume | 3 L |
| Sample Size | 108 mm × 108 mm |
| Max. Thickness | ≤3 mm |
| Carrier Gas | ≥99.999% N₂, ≥0.28 MPa (40.6 psi) |
| Interface | 1/8″ stainless steel tubing |
| Optional Compliance | 21 CFR Part 11, GMP Data Integrity, DataShield™ Audit-Trail System |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Measurement Principle | Coulometric Electrolytic Sensor (ISO 15106-3) |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 5–90 %RH (±1 %RH), optional 100 %RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Sample Thickness | ≤3 mm |
| Packaging Test Capacity | up to 3 L |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Compliance Modules | DataShield™ Data Integrity System, 21 CFR Part 11 Audit Trail, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Measurement Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 5–90 %RH (±1 %RH), optional 100 %RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² |
| Max Sample Thickness | ≤3 mm |
| Sample Size | 108 mm × 108 mm |
| Packaging Test Capacity | up to 3 L (optional) |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa |
| Gas Inlet Port | 1/8″ stainless steel tubing |
| Data Compliance | Optional CFR 21 Part 11, GMP-compliant audit trail, DataShield™ secure data management |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Price Range | USD 28,000 – 70,000 |
| Test Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90 %RH ±1 %RH (100 %RH optional) |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L |
| Carrier Gas | ≥99.999% N₂, min. pressure 0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Compliance Modules | DataShield™ Data Integrity System, 21 CFR Part 11 compliance package, GMP-compliant computer system validation support |