Labthink
Filter
Showing 151–180 of 497 results
| Brand | Labthink |
|---|---|
| Model | C640M / C640H |
| Measurement Principle | Mechanical Contact (ISO 4593, GB/T 6672) |
| Test Range (Standard) | 0–2 mm |
| Resolution | 0.1 µm |
| Repeatability | 0.8 µm (C640M) / 0.4 µm (C640H) |
| Applied Pressure | 17.5 ± 1 kPa (film, 50 mm²) / 100 ± 1 kPa (paper, 200 mm²) |
| Sample Travel Distance | 0–1000 mm (adjustable) |
| Feed Speed | 1.5–80 mm/s (adjustable) |
| Power Supply | 220–240 VAC, 50 Hz / 120 VAC, 60 Hz |
| Dimensions | 370 × 350 × 410 mm (L×W×H) |
| Weight | 26 kg |
| Compliance | ISO 4593, ISO 534, ASTM D6988, ASTM F2251, GB/T 6672, GB/T 451.3, TAPPI T411, EN 1942, JIS K6250 |
| Optional | Auto-Feeder, DataShield™ Data Integrity System, GMP-Compliant Software Module (21 CFR Part 11 Audit Trail) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | C650B Handheld |
| Price Range | USD 1,400 – 7,000 |
| O₂ Measurement Principle | Electrochemical Sensor |
| O₂ Range | 0–100% |
| O₂ Resolution | 0.1% |
| O₂ Accuracy | ±0.3% |
| O₂ Sensor Lifetime | ~2 years (in air) |
| O₂ Sample Volume | 6–8 mL (standard mode) |
| CO₂ Measurement Principle | NDIR (Non-Dispersive Infrared) |
| CO₂ Range | 0–100% |
| CO₂ Resolution | 0.01% |
| CO₂ Accuracy | ±(0.03% + 5% of reading) |
| CO₂ Sample Volume | 15 mL (standard mode) |
| Dimensions | 220 mm (L) × 110 mm (W) × 70 mm (H) |
| Power Supply | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Net Weight | 0.6 kg |
| Brand | Labthink |
|---|---|
| Model | C650B |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic Instrument |
| Price Range | USD 1,400 – 7,000 |
| O₂ Measurement Principle | Electrochemical Sensor |
| O₂ Range | 0–100% |
| O₂ Resolution | 0.1% |
| O₂ Accuracy | ±0.3% |
| CO₂ Measurement Principle | NDIR (Non-Dispersive Infrared) |
| CO₂ Range | 0–100% |
| CO₂ Resolution | 0.01% |
| CO₂ Accuracy | ±(0.03% + 5% of reading) |
| Sample Volume (O₂) | 6–8 mL |
| Sample Volume (CO₂) | 15 mL |
| Dimensions | 220 × 110 × 70 mm |
| Weight | 0.6 kg |
| Power Supply | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Brand | Labthink |
|---|---|
| Model | C650B |
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Price Range | USD 4,200 – 7,000 |
| Oxygen Measurement Principle | Electrochemical Sensor |
| CO₂ Measurement Principle (Optional) | Non-Dispersive Infrared (NDIR) |
| O₂ Range | 0–100% |
| O₂ Resolution | 0.1% |
| O₂ Accuracy | ±0.3% |
| CO₂ Range (Optional) | 0–100% |
| CO₂ Resolution (Optional) | 0.01% |
| CO₂ Accuracy (Optional) | ±(0.03% + 5% of reading) |
| Sample Volume (O₂) | 6–8 mL |
| Sample Volume (CO₂) | 15 mL |
| Dimensions | 220 × 110 × 70 mm |
| Weight | 0.6 kg |
| Power Supply | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| O₂ Sensor Lifetime | ~2 years (in ambient air) |
| CO₂ Sensor Lifetime | >15 years |
| Data Storage Capacity | 1200 test records |
| Interface | USB, optional wireless thermal printer, optional PC control software (Labthink Navigator™) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Model | C650B |
| Sensor Type (O₂) | Electrochemical |
| Sensor Type (CO₂, optional) | NDIR (Non-Dispersive Infrared) |
| O₂ Range | 0–100% |
| O₂ Resolution | 0.1% |
| O₂ Accuracy | ±0.3% |
| CO₂ Range | 0–100% |
| CO₂ Resolution | 0.01% |
| CO₂ Accuracy | ±(0.03% + 5% of reading) |
| Sample Volume (O₂) | 6–8 mL |
| Sample Volume (CO₂) | 15 mL |
| Dimensions | 220 × 110 × 70 mm |
| Weight | 0.6 kg |
| Power Supply | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| O₂ Sensor Lifetime | ~2 years (in ambient air) |
| CO₂ Sensor Lifetime | >15 years |
| Data Storage Capacity | 1200 test records |
| Interface | USB, optional wireless thermal printer, optional PC control software |
| Compliance | Designed for GLP-compliant environments |
| Brand | Labthink |
|---|---|
| Model | C650B |
| Application | O₂ (standard), CO₂ (optional) |
| Measurement Principle | Electrochemical (O₂), NDIR infrared absorption (CO₂) |
| O₂ Range | 0–100% vol |
| O₂ Resolution | 0.1% |
| O₂ Accuracy | ±0.3% |
| CO₂ Range | 0–100% vol |
| CO₂ Resolution | 0.01% |
| CO₂ Accuracy | ±(0.03% + 5% of reading) |
| Sampling Volume | 6–8 mL (O₂), 15 mL (CO₂) |
| Dimensions | 220 × 110 × 70 mm |
| Weight | 0.6 kg |
| Power Input | 100–240 VAC, 50/60 Hz |
| Sensor Lifetime | ~2 years (O₂), >15 years (CO₂) |
| Data Storage | 1200 test records |
| Compliance | Designed for ISO 8587, ASTM F2096, and USP <1207> guidance on package integrity verification |
| Brand | Labthink |
|---|---|
| Model | C650B |
| Type | Portable Headspace Gas Analyzer |
| Measurement Principle | Electrochemical (O₂), NDIR Infrared (CO₂, optional) |
| O₂ Range | 0–100% vol |
| O₂ Resolution | 0.1% |
| O₂ Accuracy | ±0.3% |
| CO₂ Range (optional) | 0–100% vol |
| CO₂ Resolution | 0.01% |
| CO₂ Accuracy | ±(0.03% + 5% of reading) |
| Sampling Volume | 6–8 mL (O₂), 15 mL (CO₂) |
| Dimensions | 220 × 110 × 70 mm |
| Weight | 0.6 kg |
| Power | 100–240 VAC, 50/60 Hz |
| Sensor Lifespan | ~2 years (O₂), >15 years (CO₂) |
| Data Storage | 1200 records |
| Compliance | ASTM F2096, ISO 11607-2, USP <1207>, GB/T 28118 |
| Brand | Labthink |
|---|---|
| Model | C650H |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Gas Measurement | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0.2–21% (v/v), Accuracy: ±0.2% O₂ |
| CO₂ Range | 2–100% (v/v), Accuracy: ±2% CO₂ |
| Sample Volume | ≥5 mL (O₂), ≥20 mL (CO₂) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Weight | 5.5 kg |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Interface | RS232 |
| Compliance | Designed for ISO 8536-4, ASTM F2476, USP <1207>, and GMP/GLP-aligned workflows |
| Brand | Labthink |
|---|---|
| Model | C650H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Price Range | USD 4,200 – 7,000 |
| Measurement Gases | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0.2–21% vol |
| O₂ Accuracy | ±0.2% vol |
| CO₂ Range | 2–100% vol |
| CO₂ Accuracy | ±2% vol |
| Sample Volume | ≥5 mL (O₂), ≥20 mL (CO₂) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Weight | 5.5 kg |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Interface | RS232 |
| Display | LCD with bilingual (EN/CN) menu interface |
| Data Storage | Internal memory |
| Printer | Integrated thermal printer |
| Sensor Type | Non-consumable ceramic electrochemical O₂ sensor (Labthink proprietary) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink International Co., Ltd. |
| Model | C650H |
| Gas Measurement | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0.2–21% (±0.2% accuracy) |
| CO₂ Range | 2–100% (±2% accuracy) |
| Sample Volume | ≥5 mL (O₂), ≥20 mL (CO₂) |
| Dimensions | 350 × 330 × 200 mm |
| Weight | 5.5 kg |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Interface | RS232 |
| Data Storage | Internal memory |
| Printer | Integrated thermal printer |
| Operating Environment | Lab, production line, warehouse |
| Compliance | Designed for ISO 8536-4, ASTM F2476, USP <1207>, and GMP/GLP-aligned workflows |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C650H Headspace |
| Price Range | USD 1,400 – 7,000 |
| O₂ Measurement Range | 0.2–21% (v/v) |
| O₂ Accuracy | ±0.2% (v/v) |
| CO₂ Measurement Range (optional) | 2–100% (v/v) |
| CO₂ Accuracy (optional) | ±2% (v/v) |
| Sample Volume Required | ≥5 mL (O₂), ≥20 mL (CO₂) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Weight | 5.5 kg |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Interface | RS232 |
| Display | LCD with bilingual (EN/CN) menu interface |
| Data Storage | Internal memory |
| Printer | Integrated thermal micro-printer |
| Brand | Labthink |
|---|---|
| Model | C650H |
| Measurement Gases | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0.2–21% vol |
| O₂ Accuracy | ±0.2% vol |
| CO₂ Range | 2–100% vol |
| CO₂ Accuracy | ±2% vol |
| Sample Volume | ≥5 mL (O₂), ≥20 mL (CO₂) |
| Dimensions | 350 × 330 × 200 mm |
| Weight | 5.5 kg |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Sensor Type | Non-consumable ceramic electrochemical O₂ sensor |
| Interface | RS232 |
| Data Storage | Internal memory |
| Printer | Integrated thermal printer |
| Display | LCD with bilingual (EN/CN) menu interface |
| Compliance | Designed for ISO 8573-7, ASTM F2476, and FDA-relevant packaging integrity assessment workflows |
| Brand | Labthink |
|---|---|
| Model | C650H |
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Price Range | USD 1,400 – 7,000 |
| Measurement Gases | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0.2–21% vol |
| O₂ Accuracy | ±0.2% vol |
| CO₂ Range | 2–100% vol |
| CO₂ Accuracy | ±2% vol |
| Sample Volume | ≥5 mL (O₂), ≥20 mL (CO₂) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Weight | 5.5 kg |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Interface | RS232 |
| Display | LCD with bilingual (EN/CN) menu interface |
| Sensor Type | Non-consumable ceramic electrochemical O₂ sensor |
| Data Storage | Internal memory (high-capacity) |
| Output | Thermal mini-printer, PC software export |
| Brand | Labthink |
|---|---|
| Model | C650H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Price Range | USD 4,200 – 7,000 |
| Gas Measurement | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0.2–21% vol |
| O₂ Accuracy | ±0.2% vol |
| CO₂ Range | 2–100% vol |
| CO₂ Accuracy | ±2% vol |
| Sample Volume | ≥5 mL (O₂), ≥20 mL (CO₂) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Weight | 5.5 kg |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Interface | RS232 |
| Display | LCD with bilingual (EN/CN) menu interface |
| Data Storage | Internal memory |
| Printer | Integrated thermal printer |
| Sensor Type | Non-consumable ceramic electrochemical O₂ sensor (Labthink proprietary) |
| Brand | Labthink |
|---|---|
| Model | C650H |
| Measurement Gases | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0.2–21% vol |
| O₂ Accuracy | ±0.2% vol |
| CO₂ Range | 2–100% vol |
| CO₂ Accuracy | ±2% vol |
| Sample Volume | ≥5 mL (O₂), ≥20 mL (CO₂) |
| Dimensions | 350 × 330 × 200 mm |
| Weight | 5.5 kg |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Sensor Type | Non-consumable ceramic electrochemical O₂ sensor |
| Compliance | Designed for ISO 8536-1/2, USP <1207>, ASTM F2476, and packaging integrity validation under GMP/GLP environments |
| Brand | Labthink |
|---|---|
| Model | C650M |
| Type | Handheld Headspace Gas Analyzer |
| Measurement Principle | Electrochemical (O₂), NDIR Infrared (CO₂, optional) |
| O₂ Range | 0–100% |
| O₂ Resolution | 0.01% |
| O₂ Accuracy | ±0.2% |
| CO₂ Range (optional) | 0–100% |
| CO₂ Resolution | 0.01% |
| CO₂ Accuracy | ±(0.03% + 5% of reading) |
| Sampling Volume | <2 mL (O₂), 15 mL (CO₂) |
| Dimensions | 220 × 110 × 70 mm |
| Weight | 0.6 kg |
| Power | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Sensor Lifetime | ~2 years (O₂), >15 years (CO₂) |
| Data Storage | 1200 test records |
| Compliance | ASTM F2476, ISO 11607-2, GB/T 28118, USP <1207> |
| Brand | Labthink |
|---|---|
| Model | C650M Portable |
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Price Range | USD 1,400 – 4,200 |
| O₂ Measurement Principle | Electrochemical Sensor |
| O₂ Range | 0–100% |
| O₂ Resolution | 0.01% |
| O₂ Accuracy | ±0.2% |
| O₂ Sensor Lifetime | ~2 years (in air) |
| CO₂ Measurement Principle | NDIR (Non-Dispersive Infrared) |
| CO₂ Range | 0–100% |
| CO₂ Resolution | 0.01% |
| CO₂ Accuracy | ±(0.03% + 5% of reading) |
| CO₂ Sensor Lifetime | >15 years |
| Sample Volume (O₂) | <2 mL (standard mode) |
| Sample Volume (CO₂) | 15 mL (standard mode) |
| Dimensions | 220 × 110 × 70 mm (L×W×H) |
| Weight | 0.6 kg |
| Power Supply | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Data Storage Capacity | 1200 test records |
| Interface Options | USB, optional wireless thermal printer, optional PC control software |
| Brand | Labthink |
|---|---|
| Model | C650M Headspace |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Price Range | USD 1,400 – 7,000 |
| O₂ Measurement Principle | Electrochemical Sensor |
| O₂ Range | 0–100% |
| O₂ Resolution | 0.01% |
| O₂ Accuracy | ±0.2% |
| CO₂ (Optional) | NDIR Absorption |
| CO₂ Range | 0–100% |
| CO₂ Resolution | 0.01% |
| CO₂ Accuracy | ±(0.03% + 5% of reading) |
| Sample Volume (O₂) | <2 mL |
| Sample Volume (CO₂) | 15 mL |
| Dimensions | 220 × 110 × 70 mm |
| Weight | 0.6 kg |
| Power | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Brand | Labthink |
|---|---|
| Model | C650M |
| Sensor Type | Electrochemical O₂ (standard), NDIR CO₂ (optional) |
| O₂ Range | 0–100% |
| O₂ Resolution | 0.01% |
| O₂ Accuracy | ±0.2% |
| CO₂ Range | 0–100% |
| CO₂ Resolution | 0.01% |
| CO₂ Accuracy | ±(0.03% + 5% of reading) |
| Sampling Volume | <2 mL (O₂), 15 mL (CO₂, standard mode) |
| Dimensions | 220 × 110 × 70 mm |
| Weight | 0.6 kg |
| Power | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| O₂ Sensor Lifetime | ~2 years (in air) |
| CO₂ Sensor Lifetime | >15 years |
| Compliance | ASTM F2476, ISO 11607-2, USP <1207>, FDA 21 CFR Part 11 (with optional software) |
| Brand | Labthink |
|---|---|
| Model | C650M |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Sensor Principle | Electrochemical (O₂), NDIR Infrared (CO₂, optional) |
| O₂ Range | 0–100% |
| O₂ Resolution | 0.01% |
| O₂ Accuracy | ±0.2% |
| CO₂ Range (optional) | 0–100% |
| CO₂ Resolution | 0.01% |
| CO₂ Accuracy | ±(0.03% + 5% of reading) |
| Sampling Volume | <2 mL (O₂), 15 mL (CO₂) |
| Dimensions | 220 × 110 × 70 mm |
| Weight | 0.6 kg |
| Power | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Labthink C660B |
| Price | Upon Request |
| Vacuum Range | 0 to −90 kPa (0 to −13 psi) |
| Vacuum Accuracy | ±0.25% FS |
| Vacuum Resolution | 0.1 kPa / 0.01 psi |
| Vacuum Hold Time | 0–9999 min 59 sec |
| Standard Vacuum Chamber Dimensions | Φ270 mm × 210 mm (H) |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz |
| Net Weight | 6.5 kg (main unit), 9 kg (standard chamber) |
| Air Supply Requirement | 0.5–0.7 MPa (73–101 psi), external source via Ø6 mm polyurethane tubing |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | C660B |
| Vacuum Range | 0 to –90 kPa (0 to –13 psi) |
| Vacuum Accuracy | ±0.25% FS |
| Vacuum Resolution | 0.1 kPa / 0.01 psi |
| Vacuum Hold Time | 0–9999 min 59 sec |
| Standard Vacuum Chamber Dimensions | Φ270 mm × 210 mm (H) |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz |
| Net Weight | 6.5 kg (host), 9 kg (standard chamber) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | C660B |
| Pricing | Upon Request |
| Vacuum Range | 0 to –90 kPa (0 to –13 psi) |
| Vacuum Accuracy | ±0.25% FS |
| Vacuum Resolution | 0.1 kPa / 0.01 psi |
| Vacuum Hold Time | 0–9999 min 59 sec |
| Standard Vacuum Chamber Dimensions | Φ270 mm × 210 mm (H) |
| Optional Chamber Sizes | Φ360 mm × 585 mm (H), Φ460 mm × 330 mm (H) |
| Air Supply Requirement | Compressed air (user-supplied), 0.5–0.7 MPa (73–101 psi) |
| Host Dimensions | 334 × 230 × 170 mm (L×W×H) |
| Power Supply | 220 VAC ±10%, 50 Hz OR 120 VAC ±10%, 60 Hz |
| Net Weight | Host: 6.5 kg |
| Standard Chamber | 9.0 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | C660B |
| Price Range | USD 1,400 – 4,200 |
| Vacuum Range | 0 to −90 kPa / 0 to −13 psi |
| Vacuum Accuracy | ±0.25% FS |
| Vacuum Resolution | 0.1 kPa / 0.01 psi |
| Vacuum Hold Time | 0–9999 min 59 sec |
| Standard Vacuum Chamber Dimensions | Φ270 mm × 210 mm (H) |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz |
| Net Weight | Host: 6.5 kg |
| Standard Chamber | 9 kg |
| Brand | Labthink |
|---|---|
| Model | C660B |
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic Instrument |
| Price Range | USD 1,400 – 4,200 |
| Vacuum Range | 0 to −90 kPa (0 to −13 psi) |
| Vacuum Accuracy | ±0.25% FS |
| Vacuum Resolution | 0.1 kPa / 0.01 psi |
| Vacuum Hold Time | 0–9999 min 59 sec |
| Standard Vacuum Chamber Dimensions | Φ270 mm × 210 mm (H) |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz |
| Net Weight | 6.5 kg (host), 9 kg (standard chamber) |
| Compliance Standards | GB/T 15171, ASTM D3078 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | C660M |
| Test Range | 0–600 kPa (standard) / 0–1.6 MPa (customizable) |
| Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.25% FS |
| Inflation Flow Rate | 0.01–10 L/min |
| Hold Time | 0.1 s – 999999.9 s |
| Inflation Nozzle Diameter | Φ10 mm (standard), Φ4 mm / Φ1.6 mm (optional) |
| Air Supply Requirement | 0.6–0.7 MPa (87–101 psi), Φ8 mm polyurethane tubing |
| Dimensions (H×W×D) | 200 × 334 × 230 mm (main unit) |
| Power | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz |
| Weight | 8 kg (unit), 16 kg (fixture) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Labthink C660M |
| Price Range | USD 4,200 – 7,000 (FOB Qingdao) |
| Test Range | 0–600 kPa (standard) |
| Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.25% FS |
| Inflation Nozzle | Φ10 mm (standard) |
| Airflow Control | 0.01–10 L/min |
| Hold Time | 0.1 s – 999999.9 s |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz |
| Dimensions (H×W×D) | 200 × 334 × 230 mm (main unit) |
| Weight | 8 kg (unit), 16 kg (fixture) |
| Compliance | ISO 11607-1/2, ASTM F1140/F2054, GB/T 10440, GB/T 17876, YBB 00252005, USP <1207>, FDA 21 CFR Part 11 (with optional DataShield™ and GMP-compliant software) |
| Brand | Labthink |
|---|---|
| Model | C660M |
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Price Range | USD 1,400 – 4,200 |
| Test Range | 0–600 kPa (standard), up to 1.6 MPa (optional) |
| Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.25% FS |
| Inflation Nozzle Diameter | Φ10 mm (standard) |
| Airflow Rate | 0.01–10 L/min |
| Hold Time | 0.1 s – 999999.9 s |
| Power Supply | 220 VAC ±10% 50 Hz or 120 VAC ±10% 60 Hz |
| Dimensions (H×W×D) | 200 × 334 × 230 mm (main unit) |
| Weight | 8 kg (unit), 16 kg (fixture) |
| Compliance Standards | ISO 11607-1, ISO 11607-2, ASTM F1140, ASTM F2054, GB/T 10440, GB 18454, GB 19741, GB 17447, GB/T 17876, GB/T 10004, BB/T 0025, QB/T 1871, YBB 00252005, YBB 00162002 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C660M |
| Price Range | USD 1,400 – 4,200 |
| Test Range | 0–600 kPa (standard) / 0–1.6 MPa (optional) |
| Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.25% FS |
| Inflation Nozzle Diameter | Φ10 mm (standard), Φ4 mm / Φ1.6 mm (optional) |
| Airflow Control Range | 0.01–10 L/min |
| Hold Time | 0.1 s – 999999.9 s |
| Air Supply Requirement | 0.6–0.7 MPa (clean, dry compressed air, user-supplied) |
| Interface | Φ8 mm polyurethane tubing |
| Dimensions (H×W×D) | 200 × 334 × 230 mm (main unit) |
| Power | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz (selectable) |
| Weight | 8 kg (unit), 16 kg (fixture) |
| Compliance | ISO 11607-1, ISO 11607-2, ASTM F1140, ASTM F2054, GB/T 10440, GB 18454, GB 19741, GB 17447, GB/T 17876, GB/T 10004, BB/T 0025, QB/T 1871, YBB 00252005, YBB 00162002 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | C660M |
| Pricing | Upon Request |
| Test Range | 0–600 kPa (standard), up to 1.6 MPa (customizable) |
| Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.25% FS |
| Inflation Nozzle Diameter | Φ10 mm (standard), optional Φ4 mm / Φ1.6 mm |
| Airflow Control | 0.01–10 L/min |
| Hold Time | 0.1 s – 999999.9 s |
| Power Supply | 220 VAC ±10% 50 Hz or 120 VAC ±10% 60 Hz |
| Dimensions (H×W×D) | 334 × 230 × 200 mm (host) |
| Weight | 8 kg (host), 16 kg (fixture) |
| Compliance | ISO 11607-1/2, ASTM F1140/F2054, GB/T 10440, GB 18454, GB 19741, GB 17447, GB/T 17876, GB/T 10004, BB/T 0025, QB/T 1871, YBB 00252005, YBB 00162002 |