Olympus
Filter
Showing 91–120 of 167 results
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer | Olympus Corporation |
| Product Type | Inverted |
| Imaging System | Integrated digital imaging and analysis software |
| Total Magnification Range | 50×–600× |
| Eyepieces | Two (standard WHN10×, field number 22) |
| Objectives | Five UIS2 infinity-corrected objectives (5×, 10×, 20×, 50×, 100×) |
| Illumination | 6 V/30 W halogen or optional 100 W fiber-optic illuminator |
| Optical System | UIS2 infinity-corrected optics with flat-field plan apochromatic correction |
| Viewing Head | Tilting binocular tube (adjustable inclination for ergonomic standing operation) |
| Compliance | Designed to support ISO 9001-compliant quality control workflows |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | GX53 |
| Configuration | Inverted |
| Integrated Image Analysis System | Yes |
| Total Magnification Range | 50×–2000× |
| Eyepieces | 2 |
| Objective Lenses | 5 |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GX71 |
| Pricing | Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GYZJ-934-1 |
| Pricing | Available Upon Request |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | HBRV-187.5 |
| Type | Combined Brinell, Rockwell & Vickers Hardness Tester |
| Drive | Motorized Load Application |
| Compliance | ASTM E10, ASTM E18, ASTM E92, ISO 6506, ISO 6508, ISO 6507 |
| Application Scope | Ferrous & Non-ferrous Metals, Heat-Treated Surfaces, Thin Hardened Sheets, Cast Iron, Carbides, Annealed & Tempered Steels |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | HBS-3000 |
| Hardness Scale | HBW (Brinell, tungsten carbide ball indenter) |
| Test Force Range | 187.5 kgf to 3000 kgf (standard Brinell load range per ISO 6506-1) |
| Indenter | 10 mm hardened steel or tungsten carbide ball |
| Optical Measurement System | High-magnification eyepiece with calibrated scale or digital image capture (optional) |
| Display | Large LCD screen with real-time test parameter and result visualization |
| Data Output | RS-232 or USB interface for printer or PC connectivity |
| Compliance | Designed to meet ISO 6506-1, ASTM E10, and JIS Z 2243 requirements |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Custom-Configurable C-Scan Platform |
| Pricing | Upon Request |
| Application Domain | Industrial NDT of Metallic Bars and Tubes |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | IX3-ICSI/IMSI |
| Instrument Type | Inverted Fluorescence Microscope |
| Excitation Source | High-Stability LED Illumination |
| Regulatory Classification | Non-Medical Device |
| Instrument Class | Research-Grade Fluorescence Microscope |
| Eyepieces | Widefield Tilting Binocular, Widefield Binocular (FN 22) |
| Objective Lenses | Interchangeable UIS2 Series with Correction Collars (20×, 40× optimized for dish-bottom thickness) |
| Condenser | Motorized Long-Working-Distance (LWD) Condenser with DIC and Relief Contrast Capabilities |
| Observation Heads | Widefield FN 22 Trinocular or Binocular Configurations |
| DIC Components | Integrated Differential Interference Contrast Module |
| Stage Options | Left-Hand Mechanical Stage, Right-Hand Cross-Stage, Right-Hand Mechanical Stage |
| Compliance | Designed for ISO 13485-aligned laboratory environments |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | IXplore IX85 |
| Instrument Type | Inverted Microscope |
| Field Number (FN) | 26.5 mm |
| Optical Design | Widefield, Plan Apochromat-Corrected Optics with Distortion-Free Imaging |
| Immersion Medium Support | Silicone Oil Immersion (Auto-Tracking Silicon Gel), Water, Glycerol, Oil |
| Correction Collar | Motorized, Auto-Adjusting for Coverslip Thickness (0.13–0.22 mm) |
| Dual Port Architecture | Integrated Dual Trinocular Ports (Simultaneous Widefield + Confocal or TIRF Pathways) |
| Modular Expansion | Compatible with Spinning Disk Confocal, TIRF, Super-Resolution (e.g., SIM), and Optogenetic Manipulation Modules |
| Software Platform | cellSens Dimension v3.x with Real-Time Deconvolution, Stitching, and GLP-Compliant Audit Trail (21 CFR Part 11 Ready) |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | IXplore SpinSR |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | IXplore IX85 SpinXL |
| Resolution (Lateral) | ~230 nm (with 1.4 NA objective) |
| Resolution (Axial) | ~600 nm (with 1.4 NA objective) |
| Lasers | 405 nm, 445 nm, 470 nm, 488 nm, 520 nm, 530 nm, 555 nm, 577 nm, 640 nm, 730 nm |
| Detectors | Up to 7 simultaneous channels |
| Scan Module | Integrated spinning-disk unit |
| Scanning Modes | Multi-mode acquisition (e.g., frame scan, line scan, ROI scan, time-lapse, Z-stack) |
| Objective Compatibility | Wide range of high-NA and correction-collared objectives (including silicone/oil/water immersion) |
| Microscope Host | Research-grade fully motorized inverted fluorescence microscope (IX85 platform) |
| Illumination Source | 89 North Laser Diode Illuminator (LDI) with independent intensity control per wavelength |
| Software & Workstation | Intelligent acquisition software with guided setup, hardware synchronization, and real-time feedback |
| Vibration Isolation | Dedicated active or passive anti-vibration optical table included |
| XY Stage Control | Motorized high-precision piezo-enhanced stage with closed-loop feedback |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | LEEB140 |
| Hardness Scales | HL, HB, HRB, HRC, HV, HS |
| Display | Full Chinese LCD Menu Interface |
| Printer | Built-in High-Speed Thermal Printer |
| Environmental Rating | Vibration-Resistant, Shock-Resistant, EMI-Immune |
| Portability | Handheld, Battery-Powered |
| Compliance | ISO 16859, ASTM A956 (Leeb Method) |
| Data Traceability | On-device Printout with Timestamp & Sample ID Support |
| Power Supply | Rechargeable Li-ion Battery |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | Leeb810A |
| Type | Shore A Hardness Tester |
| Display | Digital LCD |
| Application Scope | Rigid Plastics, Hard Rubbers, Coatings, and Polymer-Based Industrial Materials |
| Compliance | ASTM D2240, ISO 7619-1, ISO 868 |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | LEXT OLS4100 |
| Type | Laser Scanning Confocal Microscope |
| Optical Resolution (XY) | 0.12 µm |
| Axial Resolution (Z) | 10 nm |
| Laser Wavelength | 405 nm |
| Detection System | Dual-Confocal Optical Architecture |
| Measurement Modes | 7 |
| Imaging Modes | Confocal, DIC-Laser (Laser Differential Interference Contrast), Multi-Layer Surface Analysis |
| Vibration Isolation | Integrated Composite Damping Mechanism (Spiral Spring + Damping Rubber) |
| Compliance | Designed for ISO/IEC 17025-aligned metrology workflows, supports GLP/GMP documentation traceability |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | LEXT OLS4500 |
| Type | Hybrid Optical/Laser/Probe Microscope |
| Measurement Range | Millimeter to Nanometer Scale |
| Max Magnification | Up to 1,000,000× |
| Objective Lenses | Four Motorized Objectives (Low-to-Ultra-High Magnification) |
| SPM Integration | Integrated Lens-Type SPM Head on Motorized Nosepiece |
| SPM Modes | Contact, Dynamic, Phase, Current, Surface Potential, Magnetic Force (Optional) |
| Alignment | Coaxial and Confocal Objective–Cantilever Configuration |
| Automation | Guided Workflow for Rapid 3D Topography Acquisition and Analysis |
| Compliance | Designed for ISO/IEC 17025-aligned metrology workflows, supports GLP/GMP documentation traceability |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | OLS4500 |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LEXT OLS5100 |
| Pricing | Available Upon Request |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LEXT OLS5500 |
| Instrument Type | Point-Scanning Confocal Microscope |
| Laser Source | 405 nm wavelength, max output 0.95 mW, Class 2 laser (compliant with JIS C 6802:2018, IEC 60825-1:2014, EN 60825-1:2014/A11:2021, GB/T 7247.1-2024) |
| Scanning Module | Integrated design |
| Scan Speed & Resolution | Up to 4096 × 4096 pixels per single measurement |
| Objective Lenses | Interchangeable high-NA objectives including dedicated LEXT confocal and WLI objectives (up to NA 0.8) |
| Illumination | White LED for brightfield and contrast-enhanced imaging |
| Software Platform | Intelligent acquisition and analysis suite with automated parameter optimization |
| XY Stage Control | Motorized precision stage with sub-micron repeatability |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | Magna-Mike 8600 |
| Measurement Principle | Magnetic Induction (Hall Effect) |
| Max Thickness Range | 25.4 mm |
| Display | Full-color VGA (640 × 480) LCD |
| Data Output | USB 2.0, RS-232, VGA |
| Environmental Rating | IP67 |
| Drop/Shock/Vibration Compliance | MIL-STD-810G |
| Battery Life | Up to 16 h (Li-ion) |
| Operating Temperature | –10 °C to 50 °C |
| Resolution | 0.0001 in (0.001 mm) |
| Probe Options | Straight (86PR-1), Right-Angle (86PR-2) |
| Wear Cap Types | Standard, Chisel, Enhanced |
| Target Options | 6 steel balls (1.58–6.35 mm), 2 discs, 1 steel wire (1.14 mm Ø) |
| Data Logger | File-based alphanumeric recorder with .txt/.csv export to MicroSD |
| Software Interface | WINXL for Excel/SPC integration |
| Calibration Modes | Single-point, multi-point, stored calibration recall |
| Reporting | Onboard report generation, statistical strip chart view |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | MHVSX-50 |
| Loading Method | Electromechanical Closed-Loop Force Control |
| Indentation Measurement | Dual-axis Encoder-equipped Eyepiece (D1/D2) |
| Display | 7-inch High-Sensitivity Touchscreen GUI |
| Optical System | High-Resolution Metallurgical Objective Lens with 10-Step Adjustable LED Illumination |
| Data Output | USB Export to Excel (.xlsx) |
| Hardness Conversion | Vickers (HV), Brinell (HB), Rockwell (HRB/HRC) |
| Compliance | ASTM E92, ISO 6507-1, JIS Z 2244 |
| Automation | Fully Automated Turret Positioning, Motorized Indenter/Objective Switching, Auto-Focus Optional |
| Software Interface | PC Communication via Optional RS-232/USB Protocol with Audit Trail Support |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MX63 / MX63L |
| Pricing | Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | NORTEC 600 |
| Design | Portable |
| Frequency Range | 10 Hz to 12 MHz (standard operation at 60 kHz or 480 kHz for conductivity/coating applications) |
| Display | 5.7-inch VGA (640 × 480), color transflective LCD |
| IP Rating | IP66 |
| Operating Temperature | –10 °C to +50 °C |
| Battery Life | Up to 10 hours (standard mode), 6–8 hours (with rotary scanner) |
| Weight | 1.6 kg (with integrated wrist strap) |
| Compliance | EN 15548, CE, FCC, IC, RoHS, RCM, WEEE |
| Data Storage | 500 files (programs + data) |
| Interface | Dual probe ports — 16-pin LEMO (PowerLink-enabled) and BNC (auto-balancing) |
| Software | NORTEC PC (USB 2.0 connectivity, PDF report export, full-file preview, audit-ready file management) |
| Brand | OLYMPUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | N/A |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | OLS5000 |
| Pricing | Upon Request |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Custom-Integrated OmniScan MX2 Platform |
| Pricing | Upon Request |
| Application Domain | Pressure Vessel NDT, Composite & Thermoplastic Weld Integrity Assessment |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | OmniScan SX |
| Form Factor | Integrated Single-Channel PA/UT Instrument |
| Phased Array Configuration | 16:64 PR |
| UT Channels | 1 (Pulse-Echo, Pitch-Catch, TOFD) |
| Display | 8.4-inch Capacitive Touchscreen |
| Weight | ~3.2 kg (33% lighter than OmniScan MX2) |
| Dimensions | 270 × 195 × 105 mm (50% smaller volume than MX2) |
| Compliance | ASTM E2700, ISO 16810, ISO 2400, EN 12668-1, ASME BPVC Section V, API RP 2X, AWS D1.1/D1.5 |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | OmniScan X3 |
| Detection Principle | Phased Array Ultrasonics (PAUT), Total Focusing Method (TFM), Time-of-Flight Diffraction (TOFD) |
| Maximum Aperture Support | 128 elements (64-element PA probe + synthetic aperture for TFM) |
| Pulse Repetition Frequency (PRF) | Up to 3× higher than OmniScan MX2 |
| Dynamic Range | 800 dB (A-scan amplitude range) |
| Probe Compatibility | Dual-element linear and matrix arrays, encoded PA and TOFD probes |
| Software Platform | OmniPC-compatible, supports ASTM E2700, ISO 13588, EN 12668-1/3, ASME BPVC Section V Article 4 & 5 compliance workflows |
| Data Management | Onboard acquisition with full A/SA/B/C-scan export, GLP/GMP-compliant audit trail (via optional software license), FDA 21 CFR Part 11 ready |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PAUT-TOFD-CONE-S6 |
| Quotation | Available Upon Request |
| Application Domain | Aerospace Composite Structures, Hybrid Metal-Fiber Joints |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Custom PAUT Retrofit Kit |
| Pricing | Available Upon Request |
| Application Domain | Railway Rolling Stock Maintenance & Manufacturing |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | PHB-150 |
| Type | Portable Shear-Pin Operated Brinell Hardness Tester |
| Force Application | Mechanical Screw-Driven & Hammer-Impact Dual Mode |
| Hardness Scale | HBW (Brinell Hardness Number, tungsten carbide ball indenter) |
| Indentation Measurement | Optical Readout via Integrated Eyepiece Microscope |
| Compliance | Designed per ISO 6506-1, ASTM E10, and JIS Z 2243 standards |