Polymer Char
Filter
Showing 1–30 of 31 results
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CEF |
| Type | Polyolefin Characterization Analyzer |
| Automation Level | Fully Automated |
| Analysis Time per Sample | ≤25 min |
| Sample Capacity | 42-position autosampler |
| Detection Options | IR4 or IR5 FTIR concentration detectors |
| Optional Detectors | Viscometer, Multi-Angle Light Scattering (MALS) |
| Temperature Range | –20 °C to 160 °C (with low-temp and high-temp accessories) |
| Compliance | Designed for GLP/GMP environments |
| Software | CEF Control & Analysis Suite (21 CFR Part 11 compliant audit trail optional) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CFC |
| Type | Cross-Fractionation Chromatography System |
| Application | Polyolefin Microstructure Characterization |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CFC Instrument for Polymerization Process Optimization Analysis |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFC Microstructural Differentiation Analyzer |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFC |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CRYSTAF |
| Sample Capacity | 5 samples per run |
| Cycle Time | ~6 hours |
| Minimum Operating Temperature | −20 °C |
| Detection | IR4 Infrared Detector |
| Configuration | Benchtop, Fully Automated |
| Solvent Handling | Closed-loop, Minimal Consumption |
| Software Interface | Intuitive GUI with Remote Monitoring & Diagnostics |
| Upgrade Path | Compatible with CRYSTAF-TREF dual-technique configuration |
| Compliance | Designed to support GLP/GMP workflows and ASTM D7283 (Standard Test Method for Determination of Comonomer Content in Polyolefins by Crystallization Analysis) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CRYSTAF QC |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CRYSTAF-TREF |
| Technique | Dual-Mode (Crystallization Analysis Fractionation & Temperature Rising Elution Fractionation) |
| Sample Capacity | 5 samples per run |
| Analysis Time | ≤6 h/sample (TREF mode), ≤8 h for 5 samples (CRYSTAF mode) |
| Minimum Operating Temperature | −20 °C |
| Detector Options | IR4 Fourier-transform infrared detector, Differential Viscometer, Multi-Angle Light Scattering (MALS) |
| Automation Level | Fully automated solvent handling, fraction collection, and system cleaning |
| Software Compliance | Audit-trail enabled, user access control, 21 CFR Part 11–ready configuration available |
| Regulatory Alignment | Designed to support ASTM D7943, ISO 16152, and ISO 16014–4 workflows |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CRYSTEX |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CRYSTEX QC |
| Sample Vessel Capacity | 240 mL |
| Maximum Sample Mass | 4 g |
| Analysis Time per Sample | 150 min |
| Detector Configuration | Dual-channel concentration detector + composition detector |
| Operational Mode | Unattended 7×24 h |
| Solvent Handling | Fully enclosed, operator-free solvent exposure |
| Compliance | Designed for ISO 16152, ASTM D5492, and internal QC/GLP workflows |
| Software | CRYSTEX Control & Evaluation Suite with audit trail and user access levels |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EFS |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-IR Advanced |
| Application | Simultaneous Quantification of Xylene Solubles, Ethylene Content, and Intrinsic Viscosity in Impact Polypropylene |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-IR |
| Instrument Type | High-Temperature GPC System |
| Pump Flow Range | 1 mL/min |
| Maximum System Pressure | 1000 psi |
| Column Oven Temperature Range | Up to 250 °C |
| Detector Configuration | IR4 or IR5 MCT Infrared Detector (C–H selective) |
| Optional Detectors | Four-Capillary Viscometer, Multi-Angle Light Scattering (MALS), Refractive Index (RI) |
| Automation | 42-position Autosampler with Integrated Sample Dissolution, Online Filtration & Backflush, Nitrogen Deoxygenation, Flow Marker Injection |
| Software | GPC-One (Multi-Detector Synchronization, Real-Time Data Acquisition, Mark–Houwink Analysis, Branching Quantification) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GPC-IR5 |
| Service Price Range | USD 5,000–10,000 per comprehensive analysis package |
| Technical Experience | 2+ years delivering ISO-aligned polyolefin characterization services for R&D and production labs |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-IR5 |
| Temperature Range | 160 °C (max) |
| Detection | Dual IR5 Infrared Detectors (CH₂/CH₃ channels) |
| Columns | PL-PEG 10⁶–10⁷ Da & HT-Mixed-B for UHMW polyolefins |
| Solvent Compatibility | 1,2,4-Trichlorobenzene (TCB) |
| Flow Rate | 0.5–1.0 mL/min |
| Calibration Standards | Narrow-distribution polyethylene standards (NIST-traceable) |
| Software | Cirrus GPC/SEC v5.x with ASTM D6474 & ISO 16014-4 compliant reporting |
| Data Security | FDA 21 CFR Part 11–ready audit trail, electronic signatures, and user access levels |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GPC-IR5 |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-QC |
| Operating Temperature Range | 140–160 °C |
| Analysis Time per Sample (incl. dissolution) | ≤30 min |
| Detection | IR5 Selective Infrared Detector (C–H stretch, 3.42 µm) |
| Concentration Sensitivity | 0.125 mg/mL (S/N ≥60) |
| Optional Detectors | Dual Capillary Viscometer (IV), IR4 |
| Column Configuration | Pre-packed High-Throughput GPC Columns (macroporous crosslinked polystyrene/divinylbenzene, calibrated for polyolefins) |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11–ready data handling |
| Sample Throughput | Up to 24 samples unattended |
| Dimensions | Benchtop (W × D × H: 750 × 600 × 550 mm) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | HT-GPC System for Molecular Weight, Long-Chain Branching (LCB), and Short-Chain Branching (SCB) Distribution Analysis |
| Detection Modes | Infrared (IR5), Differential Viscometry, Composition-Sensitive Detection |
| Temperature Range | Up to 160 °C |
| Solvent Compatibility | 1,2,4-Trichlorobenzene (TCB), ODCB |
| Calibration Standards | Narrow-MWD PE/PP Reference Standards |
| Data Output | Mw, Mn, Mz, Đ, LCB frequency (λ), SCB density (branches/1000C), Branch Length Distribution, Compositional Heterogeneity Index (CHI) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | IR4 |
| Instrument Type | Laboratory-Scale Infrared Auxiliary Detector |
| Wavenumber Range | 3500–2500 cm⁻¹ |
| Resolution | 1 cm⁻¹ |
| Scan Speed | 12 scans/sec |
| Signal-to-Noise Ratio | 1000 |
| Flow Cell Volume | 13 µL |
| Maximum Pressure | 50 bar |
| Operating Temperature (Flow Cell & Transfer Line) | Up to 170 °C |
| Detection Modes | Concentration, Reference, Compositional (CH₃/1000C), Carbonyl (C=O/1000C) |
| Sensitivity (Concentration) | >0.3 AU·mL/mg |
| Compositional LOD | 5 CH₃/1000TC |
| Carbonyl LOD | 5 C=O/1000TC |
| Detector Noise | <1×10⁻³ AU |
| Analog Output | Four single-ended, 16-bit, 0–2.5 V / 0–10 V |
| Digital Input | TTL |
| Communication Interface | RS-232 |
| Power Supply | 90–260 VAC, 50–60 Hz |
| Control Unit Dimensions (W×H×D) | 19×6×25 cm, 4 kg |
| Spectral Unit Dimensions (W×H×D) | 15×12×9 cm, 2 kg |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | IVA |
| Dissolution Temperature Range | Up to 200 °C |
| Sample Capacity | 42 positions |
| Capillary System | Dual stainless-steel capillary viscometer |
| Optional Detector | IR4 infrared detector for C–H bond quantification |
| Solvent Handling | Fully automated solvent addition, dissolution, and system cleaning |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | IVA Versa |
| Compliance | ASTM D5225, ISO 1628-1 |
| Operating Temperature Range | 20–45 °C |
| Solvent Compatibility | Decalin, Chloroform, THF, Trichlorobenzene, and other common organic solvents |
| Sample Preparation Options | Single-sample dissolution station, High-throughput autosampler (42 vials), High-speed autosampler (15 vials) |
| Automation Level | Fully automated dissolution, filtration, dilution, and viscometric measurement |
| Cleaning | Self-cleaning dual-capillary relative viscometer design |
| Safety | Solvent-handling automation eliminates manual solvent exposure |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | Microstructural Differentiation Analyzer for Polyolefin Films and Fish-Eye Defects |
| Application Domain | Polyolefin Film Quality Control & Defect Root-Cause Analysis |
| Compliance Framework | ASTM D1238, ISO 1133, ISO 1628-1, ISO 15270, USP <1058> Analytical Instrument Qualification |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | C20 |
| Fractionation Capacity | 10–20 g per run |
| Operating Modes | TREF (Temperature Rising Elution Fractionation) and Molar Mass Fractionation |
| Cycle Time | ≤48 h including dissolution |
| Fraction Collection | Up to 9 fractions per run |
| Detection | Integrated IR detector for real-time fraction monitoring |
| Control | Remote operation and interactive diagnostics enabled |
| Compliance | Designed for GLP-compliant laboratories |
| Software | Fully automated method sequencing with audit trail capability |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | PREP C20 |
| Application | Automated Temperature Rising Elution Fractionation (TREF) and Crystallization Analysis Fractionation (CRYSTAF) of Polyolefins |
| Throughput | 10–20 g per run |
| Fraction Number | Up to 9 discrete fractions |
| Cycle Time | ~60 hours per full fractionation sequence |
| Compliance | Designed for ASTM D6964 (TREF), ASTM D7282 (CRYSTAF), ISO 16152, ISO 16014-3 |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PREP mc2 |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model Compatibility | GPC-IR5, IR4, TREF, CRYSTAF, and Related Polyolefin Analyzers |
| Lead Time | Up to 4 weeks (standard stock available for high-turnover items) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SFD |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TGIC Analysis Service |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | TGIC |
| Application Field | Polyolefin Characterization (Elastomers, Block Copolymers, Amorphous Fractions) |
| Operating Principle | Temperature-Programmed Adsorption/Desorption Chromatography in High-Temperature Solvent (e.g., 1,2,4-Trichlorobenzene) |
| Detection Options | IR4/IR5 FTIR Detectors, Viscometer, Multi-Angle Light Scattering (MALS), MCT-enhanced IR Sensitivity |
| Automation | Robotic Autosampler (42-position), Fully Integrated Solvent Delivery, Online Filtration, Remote Diagnostics |
| Software Platform | Cirrus GPC/SEC + TGIC Module (Compliant with 21 CFR Part 11 Audit Trail & User Access Control) |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Sample Throughput | Up to 42 samples unattended with method-independent sequencing |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TGIC-200 for Block Polyolefin Characterization |