ProOpto
Filter
Showing all 12 results
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | DO |
| Pricing | Upon Request |
| Lenslet Pitch | 150 µm |
| Lenslet Focal Length | 5.2 mm (customizable) |
| Dynamic Range | ≥30 µm |
| Sensitivity | λ/100 @ 633 nm |
| Measurement Accuracy | <10 nm RMS |
| Repeatability | λ/200 @ 633 nm |
| Sensor Active Area | 11.3 mm × 7.12 mm |
| Pixel Resolution | 1920 × 1200 |
| Spectral Response | 400–1000 nm |
| Frame Rate | up to 700 fps |
| Physical Dimensions | 42.6 mm × 29 mm × 29 mm |
| Supported Camera Interfaces | 20+ industrial camera types |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Model | DUV/EUV |
| Spectral Range | 190–1100 nm (with quantum conversion coating) |
| Field of View | 9 mm × 6.7 mm (customizable) |
| Dynamic Range | 14-bit |
| Hartmann Plate | precision pinholes Ø75 µm, 250 µm pitch |
| Tilt Range | ±10° |
| XY Adjustment Range | ±10 mm |
| UHV Compatibility | CF63 flange |
| Single-Pulse Repeatability (EUV) | λ/116 wrms at λ = 13.5 nm |
| Camera Support | >20 models |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EUV |
| Pricing | Upon Request |
| Standards Compliance | ISO 11551, ISO 11254, ISO 13696, ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Radiation Sources Supported | Excimer lasers (351 nm, 308 nm, 248 nm, 193 nm, 157 nm) |
| Measurement Capabilities | Absorptance (thermal lensing in fused silica @193 nm), LIDT, wavefront distortion (thermal lensing & mechanical stress), transmission, reflection, bidirectional scatter distribution (@248 nm), color center formation, fluorescence/luminescence emission |
| Imaging Support | 2D scatter mapping, LIDT site micrography, compatibility with ~20 camera types |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EUV/UV |
| Pricing | Upon Request |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Type | Imported Instrument |
| Model | EUV/XUV |
| Core Light Source Compatibility | Free-Electron Laser (FEL) |
| Wavelength Range | 1–60 nm |
| Field of View | 9 mm × 6.7 mm (optional larger FOV) |
| Dynamic Range | 14-bit |
| Hartmann Plate | Precision pinholes Ø75 µm, pitch 250 µm |
| Tilt Range | ±10° |
| XY Translation Range | ±10 mm |
| UHV-Compatible Flange | CF63 |
| Single-Pulse Wavefront Repeatability | λ/116 wrms @ 13.5 nm |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Camera Interface | Supports ~20 commercial scientific camera models |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTA |
| Pricing | Available Upon Request |
| Measurement Principle | Photothermal Deflection + Hartmann-Shack Wavefront Sensing |
| Sensor Resolution | <10 pm (≈ λ/10,000) |
| Absorption Sensitivity | Real-time ppm-level detection |
| Supported Camera Interfaces | ~20 standard scientific camera types |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Application Domain | Optical thin-film metrology, high-power laser component qualification, transient thermal distortion analysis |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NIR/EUV |
| Pricing | Upon Request |
| Spectral Range | 1100 nm – 1 nm |
| Dynamic Range | up to 100λ |
| Sensitivity | <100 pm |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Camera Compatibility | >20 industrial and scientific camera models supported |
| Micro-lens Array Options | Multiple pitch/focal-length configurations available |
| Software | ISO-compliant beam analysis suite with Zernike decomposition, M² real-time calculation, and Fresnel–Kirchhoff propagation engine |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Model | UV |
| Spectral Range | ~1–1100 nm (EUV, UV, VIS, NIR) |
| Sensor Types | >20 interchangeable CCD/CMOS cameras (small/large area, high resolution, high dynamic range) |
| Interface | USB 3.0 or GigE |
| Bit Depth | 12-bit / 14-bit |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Software | Full remote control & automation support (adaptive optics, motorized attenuators, shutters, power meters) |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Type | Imported Instrument |
| Model | UV/VIS |
| Price | Upon Request |
| Spectral Range | 190–1100 nm |
| Measurement Principle | Shack-Hartmann Wavefront Sensing |
| Dynamic Range | up to 100λ |
| Sensitivity | <100 pm |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Camera Compatibility | >20 industrial camera models supported |
| Zernike Polynomial Analysis | Yes |
| Real-time M² Calculation | Yes |
| Single-shot Acquisition | Yes |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Model | UV/VUV |
| Wavelength Range | 100–1100 nm (quantum conversion coating active <320 nm |
| Field of View | 20 mm × 14 mm (custom FOVs available) |
| Sensor | 4 MP CMOS, 12-bit, USB 3.0 interface |
| Frame Rate | up to 15 fps |
| Exposure Time | 20 µs – 1 s |
| Attenuation | prism-based attenuator (1000:1), optional ND filters |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Software | ISO-compliant beam analysis suite supporting ≥20 camera types |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | Astronomical Telescope Dedicated |
| Pricing | Upon Request |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EUV/NIR |
| Pricing | Upon Request |
| Camera Interface | USB 3.0 |
| Spatial Resolution | <10 µm |
| Spectral Range | 1100 nm (NIR) to 1 nm (soft X-ray) |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Supported Camera Types | >20 models |