Qilin (QL)
Filter
Showing 31–45 of 45 results
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | HW2000C |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | 2.5 kVA High-Frequency Induction Furnace (20 MHz) |
| Carbon Range | 0.0001–25.0000 wt% (extendable to 99.999%) |
| Sulfur Range | 0.0001–15.0000 wt% (extendable to 99.999%) |
| Sensitivity | 0.1 ppm (C/S) |
| Analysis Time | 20–1000 s (typical: 35 s) |
| Compliance | GB/T 20123–2006, ISO 15350:2000 |
| Sample Mass (steel standard) | 0.5 g nominal |
| Optical Path | Gold-Coated Absorption Cell |
| Detection Wavelengths | CO₂ @ 4.26 µm, SO₂ @ 7.4 µm |
| Modulation Frequency | 64 Hz |
| Detector Type | High-Stability Pyroelectric Sensor |
| Filtering | Narrow-Band Interference Filters |
| Dust Filtration | 0.4 µm Sintered Metal Filter |
| Power Supply | Industrial-Grade Linear Module |
| Brand | Qilin (QL) |
|---|---|
| Model | HW2000C |
| Origin | Jiangsu, China |
| Detection Principle | High-Frequency Induction Combustion Coupled with Dual-Wavelength NDIR Spectrometry |
| Measurement Range | C: 0.0001–25.0000 wt% (extendable to 99.999%) |
| S | 0.0001–15.0000 wt% (extendable to 99.999%) |
| Precision | Compliant with GB/T 20123–2006 and ISO 15350:2000 |
| Sample Mass | 0.5 g (standard solid steel reference) |
| Analysis Time | 20–100 s (typical: 35 s) |
| Sensitivity | 0.1 ppm for both C and S |
| HF Generator Output | 2200 W at 20 MHz |
| IR Source | Platinum-heated micro-source (800 °C), CO₂ band: 4.26 µm, SO₂ band: 7.4 µm |
| Detector | Gold-coated absorption cell with high-stability pyroelectric detector |
| Modulation Frequency | 64 Hz |
| Data Acquisition | 24-bit ADS1224 ADC, 20 Hz real-time sampling |
| Communication | USB 2.0 interface between host PC and embedded controller |
| Dust Filtration | 0.4 µm sintered metal filter |
| Furnace Auto-Diagnostics | Leak detection, over-current/over-time alarm, thermal stabilization via stepped motor-driven temperature control |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | HW2000C |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | 20 MHz High-Frequency Induction Furnace (2200 W) |
| Carbon Range | 0.0001–25.0000 wt% (extendable to 99.999%) |
| Sulfur Range | 0.0001–15.0000 wt% (extendable to 99.999%) |
| Sensitivity | 0.1 ppm for both C and S |
| Analysis Time | Adjustable 20–100 s (typical 35 s) |
| Precision | Compliant with GB/T 20123–2006 and ISO 15350:2000 |
| Sample Mass | 0.5 g (standard steel reference) |
| Detection Wavelengths | CO₂ @ 4.26 µm, SO₂ @ 7.4 µm |
| Dust Filter | 0.4 µm sintered metal filter |
| Optical Path | Gold-plated absorption cell, Pt-based infrared source (800 °C), pyroelectric detector, 64 Hz optical chopper |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-HW2000DH |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace |
| Carbon Range | ω(C) 0.0010–10.00% |
| Sulfur Range | ω(S) 0.0005–0.500% |
| Sensitivity | 0.1 ppm (reading resolution) |
| Accuracy | Compliant with GB/T 223.69–1997 (C) and GB/T 223.68–1997 (S) |
| Analysis Time | Adjustable 20–60 s (typical: 35 s) |
| Sample Weighing | Analytical Balance (0.0001 g resolution) |
| Operating Environment | 10–30 °C, RH < 75% |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Line | Nanjing Qilin HW2000 Series |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | 2.5 kVA High-Frequency Induction Furnace (18–20 MHz) |
| Carbon Range | 0.00001–10.0000 wt% (extendable to 99.999 wt%) |
| Sulfur Range | 0.00001–0.5000 wt% (extendable to 99.999 wt%) |
| Sensitivity | 0.1 ppm (minimum display resolution) |
| Precision | Carbon RSD ≤ 0.5%, Sulfur RSD ≤ 1.0% |
| Analysis Time | 25–60 s (user-adjustable) |
| Weighing Accuracy | 0.0001 g (compatible with Class I analytical balance) |
| Compliance | GB/T 20123–2006, ISO 15350:2000 |
| Key Components | Aviation-grade synchronous motor (≥100,000 h MTBF), narrow-band IR interference filters, pyroelectric IR detectors, Taiwan-made Airtac solenoid valves (rated ≥100,000 cycles), integrated temperature/pressure/flow compensation module |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-S3000C |
| Measurement Principle | Infrared Absorption (C/S) + Photometric Colorimetry (Multi-element) |
| Elemental Range | C (0.001–10.00%), S (0.0005–0.5000%), Mn (0.10–15.00%), Si (0.10–5.00%), P (0.005–0.80%), Cr (0.01–25.0%), Mo (0.101–6.00%), Ni (0.010–30.0%), Mg (0.010–0.100%), Rare Earths (0.01–0.100%), Cu, Al, V, W, Ti, Fe, etc. |
| Analysis Time | ~5 min (combined IR + photometric mode) |
| Wavelength Adjustment | Motor-driven holographic grating, digitally controlled, 400–800 nm, step resolution <1 nm |
| Calibration Curves | Up to 99 user-storable regression curves |
| Compliance | GB/T 223.3–5:1988, GB/T 223.68–69:1997 |
| Sample Handling | Off-line dissolution, variable-mass weighing via optional electronic balance interface |
| Data Output | ASCII/CSV export, direct thermal or dot-matrix printing |
| Software Control | Windows-based GUI with real-time data acquisition, audit trail logging, and GLP-compliant result archiving |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-S3000C |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption for C/S |
| Heating System | High-Frequency Induction Furnace (2.5 kVA peak power) |
| Detection Sensitivity | C/S: 0.1 ppm |
| Analysis Time | C/S: 25–60 s (adjustable) |
| Other Elements | 5–8 s per element |
| Measurement Ranges | C: 0.001–10.0000 wt% |
| S | 0.0005–0.5000 wt% |
| Mn | 0.10–65.00 wt% |
| Si | 0.10–75.00 wt% |
| P | 0.005–1.000 wt% |
| Cu | 0.02–85.00 wt% |
| Cr | 0.01–45.0 wt% |
| Mo | 0.10–6.00 wt% |
| Mg | 0.01–0.100 wt% |
| Ni | 0.01–50.0 wt% |
| Rare Earths | 0.01–0.100 wt% |
| Precision | Compliant with GB/T 20123–2006 (C/S), GB/T 223.69–1997 (C), GB/T 223.68–1997 (S), and GB/T 222–2006 (other elements) |
| Sample Weighing Accuracy | 0.0001 g (integrated analytical balance interface) |
| Brand | Qilin (QL) |
|---|---|
| Model | QL-S3000D |
| Measurement Principle | Non-dispersive Infrared (NDIR) for C/S |
| Analysis Time | ~2 min per sample |
| Compliance | GB/T 223.3–5:1988, GB/T 223.68–69:1997 |
| Elemental Range (Typical) | C: 0.001–10.00 wt%, S: 0.0005–0.5000 wt%, Mn: 0.10–15.00 wt%, Si: 0.10–5.00 wt%, P: 0.005–0.80 wt%, Cr: 0.01–25.0 wt%, Ni: 0.010–30.0 wt%, Mo: 0.101–6.00 wt%, Ti: 0.01–1.00 wt%, Cu: 0.01–10.00 wt%, Al: 0.01–8.00 wt% |
| Calibration | 99 programmable calibration curves (regression-based), expandable |
| Data Output | PC-controlled interface, customizable export formats (CSV, TXT, XML), thermal desktop printer support |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-TS-3 |
| Measurement Time | 240 s |
| Carbon Equivalent (CEL) | 3.2–4.8 wt%, ±0.2 wt% |
| Total Carbon (C) | 2.8–4.2 wt%, ±0.08 wt% |
| Silicon (Si) | 0.9–3.0 wt%, ±0.2 wt% |
| Temperature Display | Selectable °C or °F |
| Temperature Compensation Range | 0–40 °C |
| Compatible Cup Types | S, R, B, K |
| EMC Compliance | EN 50081-2 & EN 50082-2 |
| Display Digit Height | 50 mm |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | QL-TS-6 |
| Price Range | USD 2,800 – 7,000 |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | TS-6 |
| CE Range | 3.2–4.8 wt%, ±0.08 wt% |
| C Range | 2.8–4.2 wt%, ±0.04 wt% |
| Si Range | 0.9–3.0 wt%, ±0.04 wt% |
| Analysis Time | ≤60 s |
| Data Storage | 3000 measurements with time stamp |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-TS-6 |
| CE Range | 3.2–4.8 wt%, ±0.08 |
| C Range | 2.8–4.2 wt%, ±0.04 |
| Si Range | 0.9–3.0 wt%, ±0.04 |
| Measurement Time | ≤90 s |
| Data Storage | 3,000 measurements with timestamped sequence |
| Calibration Lines | 8 user-definable |
| Target Compositions | 8 preset alloys |
| Output | USB export supported |
| Industrial Display | 17″ ruggedized LCD |
| Thermal Compensation | Integrated high-stability thermocouple wiring |
| EMC Design | Enhanced EMI/RFI shielding for foundry floor deployment |
| Compliance | Designed to support ISO 9001 process control documentation and ASTM A781/A781M for cast iron analysis workflows |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-TS-6 |
| Measurement Principle | Thermal Analysis (Solidification Curve Monitoring via Immersion Thermocouple) |
| Measurement Time | ≤90 s per sample |
| CE Range | 3.2–4.8 wt%, ±0.08 wt% accuracy |
| C Range | 2.8–4.2 wt%, ±0.04 wt% accuracy |
| Si Range | 0.9–3.0 wt%, ±0.04 wt% accuracy |
| Data Storage Capacity | 3,000 measurements with timestamped sequence |
| Output Interface | USB flash drive export optional |
| Compliance | Designed for foundry floor deployment under ISO 9001 and ASTM E1157 (Standard Practice for Sampling and Testing Cast Iron) environments |
| Operating Environment | Industrial-grade embedded PC with fanless motherboard, 17″ ruggedized LCD display, EMI-hardened signal acquisition architecture |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-TS-6 |
| CE Measurement Range | 3.2–4.8 wt%, ±0.08 |
| C Measurement Range | 2.8–4.2 wt%, ±0.04 |
| Si Measurement Range | 0.9–3.0 wt%, ±0.04 |
| Analysis Time | 90 s |
| Data Storage Capacity | 3,000 measurements |
| Calibration Lines | 8 user-definable |
| Target Compositions | 8 programmable |
| Output | USB flash drive export supported |
| Industrial Display | 17″ ruggedized LCD |
| Thermal Compensation | Imported compensated thermocouple wiring |
| EMC Design | EMI-shielded enclosure with anti-interference mounting base |
| Software | Proprietary molten iron analysis platform with cooling curve visualization, differential solidification analysis, and automated charge calculation |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | TS-6 |
| Measurement Principle | Thermal Analysis (Solidification Curve-Based Inverse Calculation) |
| CE Range | 3.2–4.8 wt%, ±0.08 |
| C Range | 2.8–4.2 wt%, ±0.04 |
| Si Range | 0.9–3.0 wt%, ±0.04 |
| Analysis Time | ≤90 s |
| Data Storage | 3000 measurements with timestamped sequence |
| Calibration Lines | 8 user-definable |
| Target Compositions | 8 pre-set |
| Output | USB export supported |
| Display | 17″ industrial-grade LCD (fanless embedded PC platform) |
| Environmental Rating | Designed for foundry floor operation (EMI-hardened, temperature-compensated thermocouple interface) |