| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-CS20D |
| Measurement Principle | Gas Volumetric Method (C), Iodometric Titration (S) |
| Heating System | Arc Furnace |
| Carbon Range | 0.02–6.00 wt% |
| Sulfur Range | 0.005–0.300 wt% |
| Sample Mass Options | 0.25 g / 0.5 g / 1.0 g |
| Analysis Time | 65 s (single absorption) or 85 s (dual absorption) with DL1A arc furnace |
| Compliance | GB/T 223.69–1997 (C), GB/T 223.68–1997 (S) |
| Readout | Direct digital display of mass fraction (%) with thermal printer output |
| Operating Environment | 0–40 °C, 90.658–106.658 kPa |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | CS20D |
| Measurement Principle | Gas Volumetric Method (C), Iodometric Titration (S) |
| Heating System | Arc Furnace |
| Carbon Range | 0.05–6.00 wt% |
| Sulfur Range | 0.005–0.300 wt% |
| Sample Weight Options | 0.25 g / 0.5 g / 1.0 g |
| Analysis Time | 45 s (with DL1A arc furnace) |
| Readout | Direct digital display of mass fraction (%) with thermal printer output |
| Accuracy | Compliant with GB/T 223.69–1997 (C) and GB/T 223.68–1997 (S) |
| Operating Environment | 0–40 °C, 90.658–106.658 kPa |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | QL-HW2000 |
| Price Range | USD 7,000–14,000 (FOB) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Combustion Source | 2.5 kVA High-Frequency Induction Furnace (18–20 MHz) |
| Carbon Range | 0.00001–10.0000 wt% (extendable to 99.999 wt%) |
| Sulfur Range | 0.00001–0.5000 wt% (extendable to 99.999 wt%) |
| Sensitivity | 0.1 ppm (minimum display resolution) |
| Precision | Carbon RSD ≤ 0.5%, Sulfur RSD ≤ 1.0% |
| Analysis Time | 25–60 s (user-adjustable) |
| Compliance | GB/T 20123–2006, ISO 15350:2000 |
| Sample Weighing Accuracy | 0.0001 g (via integrated analytical balance interface) |
| Optical Detection | High-stability pyroelectric infrared detectors with narrow-band interference filters |
| Gas Handling | Precision mass flow control |
| Mechanical Drive | Aerospace-grade synchronous motor in IR absorption cell (rated >100,000 h MTBF) |
| Brand | Qilin/QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | QL-HW2000DH |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | High-Frequency Induction Furnace |
| Carbon Range | ω(C) 0.0010–10.00 wt% |
| Sulfur Range | ω(S) 0.0005–0.500 wt% |
| Sensitivity | 0.1 ppm (as displayed reading) |
| Accuracy | Compliant with GB/T 223.69–1997 (C) and GB/T 223.68–1997 (S) |
| Analysis Time | Adjustable 20–60 s (typical: 35 s) |
| Sample Weighing | Analytical Balance (0.0001 g resolution) |
| Operating Environment | 10–30 °C, RH < 75% |
| Brand | Qilin (QL) |
|---|---|
| Model | BS1000G |
| Origin | Jiangsu, China |
| Type | Benchtop Photometric Elemental Analyzer |
| Optical System | Adjustable-Wavelength Self-Collimating Diffraction Grating (Right-Exit) |
| Wavelength Accuracy | ±3 nm |
| Measurable Elements (typical) | Mn (0.10–65.00 wt%), Si (0.10–75.00 wt%), P (0.005–1.00 wt%), Cu (0.02–85.00 wt%), Cr (0.01–45.00 wt%), Ni (0.01–50.00 wt%), Mo (0.101–6.00 wt%), Mg (0.010–0.100 wt%), Rare Earths (0.01–0.100 wt%) |
| Analytical Method | Photometric Colorimetry with Computer-Controlled Wavelength Selection |
| Measurement Time per Sample | ≤5 s |
| Weighing Device | 0.0001 g Precision Electronic Balance (1/10,000 g resolution) |
| Compliance | GB/T 223 series (Chinese national standards for metallurgical analysis) |
| Operating Environment | 10–30 °C, RH <75% |
| Data Output | Integrated thermal printer (Chinese-language interface), PC-based data logging |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL HW2000B |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | 2.5 kVA High-Frequency Induction Furnace (18–20 MHz) |
| Carbon Range | 0.00001–10.0000 wt% (extendable to 99.999 wt%) |
| Sulfur Range | 0.00001–0.5000 wt% (extendable to 99.999 wt%) |
| Sensitivity | 0.1 ppm (minimum display resolution) |
| Precision | Carbon RSD ≤ 0.5% |
| Analysis Time | 25–60 s (user-adjustable) |
| Sample Weighing Accuracy | 0.0001 g |
| Compliance | GB/T 20123–2006 & ISO 15350:2000 |
| Detector Type | High-Stability Pyroelectric Infrared Detector with Narrow-Band Optical Filters |
| Gas Control | Precision Mass Flow Controllers + Airtac Solenoid Valves (rated for ≥100,000 cycles) |
| Drive Mechanism | Aerospace-Grade Synchronous Motor in IR Absorption Cell (MTBF > 100,000 h) |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | HW2000BA |
| Measurement Principle | Infrared Absorption (C/S), Photometric Colorimetry (Mn, P, Si, Cr, Ni, etc.) |
| Heating System | High-Frequency Induction Furnace |
| Rated Output Power | 2.5 kVA |
| Carbon Range | 0.0001–99.999 wt% |
| Sulfur Range | 0.0001–99.999 wt% |
| Manganese | 0.10–65.00 wt% |
| Silicon | 0.10–75.00 wt% |
| Phosphorus | 0.005–1.80 wt% |
| Chromium | 0.01–65.0 wt% |
| Nickel | 0.010–30.0 wt% |
| Molybdenum | 0.101–6.00 wt% |
| Magnesium | 0.010–0.100 wt% |
| Rare Earth Elements | 0.01–0.100 wt% |
| Wavelength Range (Colorimetric Module) | 400–800 nm (motorized grating, step resolution <1 nm) |
| Calibration Curves | Up to 99 user-storable regression curves |
| Compliance | GB/T 223.3–5:1988, GB/T 223.68–69:1997 |
| Operating Environment | 0–40 °C |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | HW2000E(D) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace |
| Carbon Range | 0.001–10.000 wt% (extendable to 99.999 wt%) |
| Sulfur Range | 0.0005–0.5000 wt% (extendable to 99.999 wt%) |
| Analysis Time | 25–60 s (typical: 35 s) |
| Power Consumption | <2.5 kVA |
| Weight | 135 kg |
| Compliance | Meets GB/T 20123–2006 and ISO 15350:2000 requirements for solid metallic materials |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | QL-5800A |
| Instrument Type | Floor-standing |
| Excitation Method | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 130–600 nm |
| Number of Analytical Channels | 32 |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QL-5800E |
| Price | USD 23,500 (FOB Nanjing) |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | High-Performance CCD Array |
| Focal Length | 401 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 140–680 nm |
| Number of Spectral Channels | 60 |
| Optical System | Paschen-Runge Mount with Vacuum-Enclosed Roland Circle |
| Light Source | Digital Plasma Spark Source with High-Energy Pre-Ignition (HEPS) |
| Discharge Frequency | 100–1000 Hz |
| Power Supply | AC 220 V, 50/60 Hz, 1000 W |
| Dimensions (W×D×H) | 780 × 565 × 360 mm |
| Weight | 78 kg |
| Typical Analysis Time | ~20 s per sample |
| Electrode Material | Tungsten Jet Electrode |
| Inter-Electrode Gap | 4 mm |
| Vacuum System | Multi-Stage Oil-Backstream Prevention with Differential Pressure Valve and In-Line Oil Trap |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | QL-5800E |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | CCD Array |
| Focal Length | 401 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 140–680 nm |
| Number of Detection Channels | 60 |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | QL-5800E |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | High-Performance CMOS Array (CCD-compatible architecture) |
| Focal Length | 401 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 140–680 nm |
| Number of Detection Channels | 60 |
| Power Supply | AC 220 V, 50/60 Hz, 1000 W |
| Dimensions (W×D×H) | 780 × 565 × 360 mm |
| Weight | 78 kg |
| Typical Analysis Time | ~20 s per sample |
| Inter-electrode Gap | 4 mm |
| Electrode Material | Tungsten |
| Vacuum System | Integrated oil-free vacuum with differential pressure valve and multi-stage oil-trap protection |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QL-BS3B |
| Price | USD 1,380 (FOB Nanjing) |
| Measurement Principle | Photometric Colorimetry with Cold Light Sources |
| Elements Measured | Si, Mn, P, Ni, Cr, Cu, Rare Earths, Mg, Fe, Al, V, W, Ti |
| Typical Range (w/w) | Mn 0.10–15.00%, Si 0.10–5.00%, P 0.005–0.80%, Cr 0.010–25.0%, Mo 0.010–6.00%, Mg 0.010–0.99% |
| Detection Method | Dual-beam photometry using imported silicon photodiodes |
| Calibration | Automatic zero & full-scale self-calibration |
| Curve Storage | 15 user-programmable calibration curves |
| Input Interface | Touch-sensitive membrane keypad with audible feedback |
| Sample Preparation | External fusion (crucible-based), valve-free and tubing-free design |
| Optical Source | Interchangeable cold-light sources for spectral adaptability |
| Brand | Qilin/QL |
|---|---|
| Origin | Jiangsu, China |
| Model | HW2000B |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | 2.5 kVA High-Frequency Induction Furnace (18–20 MHz) |
| Carbon Range | 0.00001–10.0000 wt% (extendable to 99.999 wt%) |
| Sulfur Range | 0.00001–0.5000 wt% (extendable to 99.999 wt%) |
| Sensitivity | 0.1 ppm (minimum display resolution) |
| Precision | Carbon RSD ≤ 0.5%, Sulfur RSD ≤ 1.0% |
| Analysis Time | 25–60 s (user-adjustable) |
| Sample Weighing Accuracy | 0.0001 g |
| Compliance | GB/T 20123–2006, ISO 15350:2000 |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | S3000C |
| Price | USD 9,500 (FOB Jiangsu) |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-TS-6 |
| Measurement Time | 90 s |
| CE Range | 3.2–4.8 wt% (±0.08 wt%) |
| C Range | 2.8–4.2 wt% (±0.04 wt%) |
| Si Range | 0.9–3.0 wt% (±0.04 wt%) |
| Data Storage | 3,000 measurements |
| Display | 17″ industrial-grade LCD |
| Software | Proprietary casting-specific analysis suite with automatic charge calculation, 8 calibration curves, 8 target compositions, differential curve visualization, and USB data export capability |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | QL-TS-8 |
| Price | USD 5,300 (FOB Jiangsu) |
| CE Range | 3.2–4.8 wt% (±0.08 wt%) |
| C Content | 2.8–4.2 wt% (±0.04 wt%) |
| Si Content | 0.9–3.0 wt% (±0.04 wt%) |
| Analysis Time | ≤60 s |
| Data Storage Capacity | 3,000 measurements |
| Calibration Lines | 8 user-defined |
| Target Compositions | 8 configurable |
| Graphical Output | Solidification curve, derivative curve (dT/dt), trend plots |
| USB Export | Optional |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QL2000 |
| Price Range | USD 7,000–14,000 (FOB) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Combustion System | High-Frequency Induction Furnace (2.2 kW, 20 MHz) |
| Carbon Range | 0.0001–25.0000 wt% (extendable to 99.999 wt%) |
| Sulfur Range | 0.0001–15.0000 wt% (extendable to 99.999 wt%) |
| Sensitivity | 0.1 ppm for both C and S |
| Precision | Compliant with GB/T 20123–2006 and ISO 15350:2000 |
| Analysis Time | Adjustable from 20–100 s (typical: 35 s) |
| Sample Mass | 0.5 g (standard steel reference material) |
| Continuous Operation | 24 h unattended |
| Brand | Qilin (QL) |
|---|---|
| Model | QL-28W |
| Type | Portable Emission Spectroscopic Analyzer (Arc/Spark Excitation) |
| Wavelength Range | 390–700 nm |
| Operating Voltage | AC 220 V, 50 Hz |
| Arc Current | ~5 A |
| Host Weight | 4.5 kg |
| Generator Weight | 3.0 kg |
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Compliance | Domestic GB/T Standards for Metal Spectral Analysis Instruments |
| Pricing | USD 1,780 (FOB Jiangsu) |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 4XC |
| Price Range | USD $1,400 – $7,200 |
| Configuration | Inverted |
| Integrated Image Analysis Software | Yes |
| Total Magnification Range | 100× – 1250× |
| Eyepieces | 10×, 12.5× wide-field |
| Objective Lenses | 10×, 40×, 100× (oil immersion), with optional 20× and 50× objectives |
| [Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector | CCD Array |
| Focal Length | 400 mm |
| Groove Density | 2400 lines/mm |
| Wavelength Range | 130–900 nm |
| Number of Channels | 60] |
| Brand | Qilin (QL) |
|---|---|
| Model | QL-5800E |
| Instrument Type | Benchtop OES |
| Excitation Source | Spark Discharge |
| Detector | CCD Array |
| Focal Length | 401 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 140–680 nm |
| Number of Detection Channels | 60 |
| Optical System | Paschen–Runge Mount with Vacuum-Enclosed Roland Circle |
| Base Materials Supported | Fe, Cu, Al, Ni, Co, Mg, Ti, Zn, Pb, Sn, Ag |
| Analysis Time | ~20 s per sample |
| Dimensions | 780 × 565 × 360 mm |
| Weight | 78 kg |
| Power Supply | AC 220 V, 50/60 Hz, 1000 W |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-BS1000 |
| Wavelength Range | 400–800 nm (continuously adjustable) |
| Absorbance Range | 0–1.999 A |
| Concentration Display Range | 0.000–99.99% (auto-ranging) |
| Wavelength Accuracy | ±3 nm |
| Photometric Resolution | 0.001 A |
| Data Storage | Onboard EEPROM (retains data for ≥10 years without power) |
| Display | 1-inch numeric LED display |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Power Consumption | ≤45 W |
| Net Weight | ≤15 kg |
| Compliance | Designed per GB/T 20001.4–2015 (Chinese Standard for Analytical Instrument Documentation), compatible with ASTM E306 and ISO 4943 methodologies for optical emission and absorption-based metal analysis |
| Brand | Qilin (QL) |
|---|---|
| Model | QL-BS1000 |
| Origin | Jiangsu, China |
| Wavelength Range | 400–800 nm (continuously adjustable) |
| Absorbance Range | 0–1.999 A |
| Concentration Display Range | 0.000–99.99% (auto-ranging) |
| Wavelength Accuracy | ±3 nm |
| Data Storage | Onboard EEPROM (retains data for ≥10 years without power) |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Power Consumption | ≤45 W |
| Net Weight | ≤15 kg |
| Display | 1-inch numeric LED display |
| Calibration | Auto-zero and full-scale calibration using cold light source and imported photodetectors |
| Curve Storage | Up to 9 pre-programmed calibration curves |
| Sample Handling | External dissolution |
| Optical System | Adjustable-wavelength monochromatic light source with microprocessor-controlled spectral selection |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-BS1000G |
| Wavelength Range | 400–750 nm (motorized auto-adjustable) |
| Absorbance Range | 0–1.999 A |
| Concentration Display Range | 0.000–99.99% (auto-ranging) |
| Measurement Time | ~2 minutes per sample |
| Analytical Accuracy | Compliant with GB/T 223.3–223.5–1988 and equivalent ISO/ASTM elemental analysis standards |
| Detection Elements | Si, Mn, P, Cr, Ni, Mo, Cu, Ti, V, Mg, Al, W, Rare Earths (Ce, La), Fe, etc. |
| Calibration Curves | Up to 99 user-definable, regression-based calibration curves stored in PC memory |
| Sample Introduction | Off-instrument acid dissolution (external digestion) |
| Detection Principle | Photometric colorimetry with tunable-wavelength optical system |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Power Consumption | 350 W |
| Interface | PC-controlled via USB/RS232 |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-DS3C |
| Magnification Range | 100×–1250× |
| Illumination | 6 V / 20 W Halogen Lamp |
| Focusing Travel | 26 mm |
| Fine Focus Graduation | 0.002 mm |
| Stage Travel | 75 mm × 50 mm |
| Objective Lenses | 10×, PL 40×, 100× (Oil Immersion) |
| Eyepieces | Wide-Field 10×, 12.5× |
| Digital Imaging Interface | USB 2.0 CMOS Camera Support |
| Software Compatibility | Windows-based metallurgical image analysis suite (optional) |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-HW2000 Series |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | 2.5 kVA, 18 MHz High-Frequency Induction Furnace |
| Carbon Range | 0.00001%–99.999% |
| Sulfur Range | 0.00001%–99.999% |
| Sensitivity | 0.1 ppm |
| Analysis Time | Adjustable 25–60 s (typical 35 s) |
| Weighing Capacity | 0–120 g |
| Balance Resolution | 0.0001 g |
| Compliance | GB/T 20123–2006, ISO 15350:2000, ISO 9556:1989 (C), ISO 4935:1989 (S) |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | HW2000B |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | 2.5 kVA High-Frequency Induction Furnace (18–20 MHz) |
| Carbon Range | 0.00001–10.0000 wt% (extendable to 99.999 wt%) |
| Sulfur Range | 0.00001–0.5000 wt% (extendable to 99.999 wt%) |
| Sensitivity | 0.1 ppm (minimum detectable increment) |
| Precision | Carbon RSD ≤ 0.5%, Sulfur RSD ≤ 1.0% |
| Analysis Time | 25–60 s (user-adjustable) |
| Sample Weighing Accuracy | 0.0001 g |
| Compliance | GB/T 20123–2006, ISO 15350:2000 |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-HW2000B |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace (2.5 kVA, 18 MHz) |
| Measurement Range | C: 0.00001–99.999 wt%, S: 0.00001–99.999 wt% |
| Sensitivity | 0.1 ppm |
| Accuracy | Compliant with GB/T 20123–2006 and ISO 15350:2000 |
| Analysis Time | Adjustable from 25 to 60 s (typical: 35 s) |
| Balance Integration | Automatic linkage with 0–120 g capacity, 0.1 mg readability |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-HW2000B |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | 2.5 kVA High-Frequency Induction Furnace (18–20 MHz) |
| Carbon Range | 0.00001–10.0000 wt% (extendable to 99.999 wt%) |
| Sulfur Range | 0.00001–0.5000 wt% (extendable to 99.999 wt%) |
| Sensitivity | 0.1 ppm (minimum display resolution) |
| Precision | Carbon RSD ≤ 0.5%, Sulfur RSD ≤ 1.0% |
| Analysis Time | 25–60 s (user-adjustable) |
| Compliance | GB/T 20123–2006, ISO 15350:2000 |
| Sample Weighing Accuracy | 0.0001 g |
| Detector Type | High-Stability Pyroelectric Infrared Detector with Narrow-Band Interference Filters |
| Gas Control | Precision Mass Flow Controllers + Airtac (Taiwan) Solenoid Valves (rated for ≥100,000 cycles) |
| Optical Drive | Aerospace-Grade Synchronous Motor (MTBF > 100,000 h) |