Sable
Filter
Showing all 17 results
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AD-2 |
| Price Range | USD 7,200 – 14,300 |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CA-10 |
| Pricing | Upon Request |
| Brand | Sable |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | DR4-Series Dynamic Respirometer |
| Pricing | Upon Request |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FMS Portable |
| Pricing | Available Upon Request |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FMS |
| Pricing | Upon Request |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FMS- |
| Price Range | USD 7,200 – 14,300 |
| Dimensions | 35 × 30 × 15 cm |
| Weight | 4.0 kg |
| Power Supply | 12–15 VDC (AC adapter included) |
| Data Storage | Removable SD card (up to 32 GB) |
| Sampling Interval | 0.1 s – 1 h (user-configurable) |
| Gas Flow Control | 10–1500 mL/min (microelectronic thermal feedback loop, ±2% accuracy) |
| O₂ Sensor | Fuel cell, 0–100%, resolution 0.001%, drift <0.02%/h |
| CO₂ Sensor | NDIR dual-wavelength, 0–5%, resolution 0.0001–0.01%, drift <0.001%/h |
| H₂O Sensor | Platinum-electrode capacitive, 0–100% RH (non-condensing), resolution 0.001% RH, drift <0.01% RH/h |
| Temperature Compensation | Automatic (0–100 °C, ±0.2 °C accuracy) |
| Pressure Compensation | Automatic (30–110 kPa) |
| Analog Inputs | 8-channel bipolar voltage, 4-channel temperature |
| Digital I/O | 8 TTL control outputs, RS-232/USB + SableBus high-speed interface |
| Brand | Sable |
|---|---|
| Origin | USA |
| Model | FOXBOX |
| Gas Analyzers | Fuel Cell O₂ Sensor & NDIR CO₂ Sensor |
| O₂ Range | 0–100% |
| CO₂ Range | 0–5% |
| O₂ Accuracy | ±0.1% |
| CO₂ Accuracy | ±1% |
| O₂ Drift | <0.02%/hr (stable temp) |
| CO₂ Drift | <0.001%/hr (stable temp) |
| O₂ Resolution | 0.001% |
| CO₂ Resolution | 0.0001–0.01% (concentration-dependent) |
| Flow Control | Microprocessor-Regulated Thermal Feedback Loop |
| Flow Range (Internal Pump) | 10–1700 mL/min |
| Flow Accuracy | ±2% |
| Flow Resolution | 0.1 mL/min (0–99.9 mL/min), 1 mL/min (>100 mL/min) |
| Data Storage | 8,190 points |
| Logging Interval | 0.1 s to 1 hr (user-selectable) |
| Interface | RS-232, 2× BNC analog inputs, 3× BNC analog outputs |
| Display | 4-line LCD (real-time O₂, CO₂, flow) |
| Power | 12–15 VDC, 50–500 mA |
| Dimensions | 31 × 18 × 31 cm |
| Weight | 5 kg |
| Brand | Sable |
|---|---|
| Origin | USA |
| Model | SoilBox-FGA |
| Instrument Type | Multi-parameter Soil Respiration & Gas Exchange Analyzer |
| O₂ Analyzer | Fuel Cell Technology |
| CO₂ Analyzer | Nondispersive Dual-Wavelength Infrared (NDIR) |
| O₂ Range | 0–100% |
| CO₂ Range | 0–5% |
| O₂ Accuracy | ±0.1% |
| CO₂ Accuracy | ±1% of reading |
| O₂ Resolution | 0.001% |
| CO₂ Resolution | 0.0001–0.01% (range-dependent) |
| O₂ Drift | <0.02%/hr (constant temperature) |
| CO₂ Drift | <0.001%/hr (constant temperature) |
| Flow Control | Microprocessor-regulated thermal feedback loop with integrated diaphragm pump and thermal-mass flowmeter |
| Flow Range | 10–1700 mL/min |
| Flow Accuracy | ±2% |
| Flow Resolution | 0.1 mL/min (0–99.9 mL/min), 1 mL/min (>100 mL/min) |
| Data Storage | 8,190 points |
| Logging Interval | 0.1 s to 1 h (user-configurable) |
| Display | 4-line LCD (real-time CO₂, O₂, flow rate, status) |
| I/O | 2× BNC analog inputs, 3× BNC analog outputs (O₂, CO₂, user-defined), RS-232 digital interface |
| Power | 12–15 VDC, 50–500 mA |
| Operating Temperature | 0–50 °C (non-condensing) |
| Dimensions (FGA unit) | 31 × 18 × 31 cm |
| Weight (FGA unit) | 5 kg |
| Soil Chamber | Aluminum or transparent acrylic, 20 cm ID × 20 cm height, low thermal inertia design |
| Optional Sensors | Soil temperature (thermistor, –5 to 60 °C, ±0.2 °C), air humidity (±2% RH), PAR/solar radiation (±5%), soil moisture (TRIME-PICO TDR), external CH₄ analyzer (dual-wavelength IR, 0–10%, 1 ppm resolution, ±1% accuracy, pressure-compensated) |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SoilBox-FMS |
| Instrument Type | Multifunctional Soil Analyzer |
| Key Specifications | CO₂ resolution ≤0.0001%, O₂ resolution 0.001%, H₂O resolution 0.001% RH, flow control 10–1500 mL/min (±2% accuracy), 14-channel data logger, dual-path baseline switching, integrated T/P compensation, 0.1 s–1 h user-defined logging interval, 32 GB SD storage, 12–15 VDC operation (AC adapter & optional Li-ion battery), operating temp 3–50 °C, dimensions 35 × 30 × 15 cm, weight 4 kg |
| Brand | Sable |
|---|---|
| Origin | USA |
| Model | SoilLab |
| Instrument Type | Multi-channel Laboratory Soil Respiration System |
| Gas Analyzers | CO₂ (NDIR), O₂ (Fuel Cell), Optional CH₄ (TCD), H₂O (Capacitive) |
| Channel Configurations | 4, 8, 16, or 24 channels |
| Compliance | ISO 14240-1 (Substrate-Induced Respiration for Microbial Biomass), ASTM D5039 (Soil Respiration Testing), GLP-Compatible Data Logging |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Scientific Instrument |
| Model | SSI Drosophila |
| Instrument Type | Research-Grade Small Animal (Drosophila & Micro-Invertebrate) Respirometry System |
| Key Measurement Parameters | Real-time CO₂ production (VCO₂), O₂ consumption (VO₂), respiratory quotient (RQ), water vapor pressure (H₂O), activity (via IR beam interruption), optional temperature & feeding behavior |
| Channel Configurations | 8-channel standard (7 sample + 1 baseline), expandable to 16-, 24-, or custom N-channel modular configurations |
| Analytical Principle | Open-flow indirect calorimetry with dual-wavelength NDIR CO₂ detection, paramagnetic or fuel-cell O₂ sensing, differential gas analysis architecture for single-fly resolution |
| Compliance Framework | Designed for GLP-compliant metabolic phenotyping |
| Software Platform | ExpeData™ (Windows-based, real-time acquisition, automated RQ/EE calculation, event-triggered sampling, batch analysis, export to CSV/MAT/Excel) |
| Optional Modules | AD-2 Infrared Activity Monitor, FLIC Feeding Behavior Module, MAVEn™ High-Density Integration Chassis, RH-300 Water Vapor Analyzer, SS4 Secondary Sampling Unit, MFC-2 Mass Flow Controller |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SSI Modular |
| Instrument Type | Research-grade Rodent Metabolic Phenotyping System |
| Sample Capacity | Configurable Multi-channel (Standard 8-channel: 7 animal + 1 baseline) |
| Core Analytes | O₂, CO₂, H₂O vapor |
| Measurement Principle | Open-circuit respirometry with dual-wavelength NDIR CO₂ detection, paramagnetic O₂ sensing, and chilled-mirror dew-point H₂O analysis |
| Compliance Framework | Designed for GLP-compliant metabolic phenotyping |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SSI |
| Price Range | USD 7,200 – 14,300 |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SSI-System |
| Price Range | USD 7,200 – 14,300 (FOB USA) |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SSI-High-Throughput |
| Pricing | Upon Request |
| Brand | Sable |
|---|---|
| Origin | USA |
| Model | MAVEn™ High-Throughput 16-Channel |
| Flow Rate Range | 5–200 mL/min (mass flow controlled, ±2% accuracy) |
| Measurement Interval per Fly | 15 s (programmable from 15 s to 3 h) |
| O₂ Analyzer | Dual-channel fuel-cell sensor, 0–100% range, ±0.1% accuracy (2–100% O₂), 0.0001% resolution, <0.01%/h drift |
| CO₂ Analyzer | 0–3000 ppm, <1% accuracy, 0.01 ppm resolution |
| H₂O Analyzer | 0–60 mmol/mol, ±1% accuracy |
| Pressure Sensor | 1 Pa resolution, ±0.05% FS accuracy |
| Temperature Sensor | 0–50 °C, ±0.25 °C accuracy, 0.01 °C resolution |
| Illuminance Control | 0.1–5000 lux |
| Analog Inputs | 6 channels, 16-bit, −5 to +5 V |
| Data Output | CSV via SD card (up to 32 GB), RS-232, 0–5 V BNC analog outputs |
| Dimensions (O₂ Unit) | 43.2 × 35.6 × 20.3 cm |
| Weight (O₂ Unit) | 6.4 kg |
| Operating Temp | 5–45 °C, non-condensing |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SSI-Human |
| Pricing | Upon Request |