SkyRay Instrument
Filter
Showing 1–30 of 94 results
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AAS6000 |
| Instrument Type | Flame Atomic Absorption Spectrometer |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 0.7 / 1.4 nm (auto-switching) |
| Grating | 1800 lines/mm, blaze wavelength 230 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | < 0.10 nm |
| Resolution | < 0.3 nm |
| Characteristic Concentration (Cu) | < 0.025 µg/mL per 1% absorption |
| Detection Limit (Cu) | < 0.006 µg/mL |
| Precision (Cu) | < 0.8% RSD |
| Baseline Stability | 0.003 Abs (static), 0.004 Abs (dynamic) |
| Background Correction | D₂ lamp + Self-absorption (up to 1 A) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AAS9000 |
| Instrument Type | Integrated Flame/GF AAS |
| Monochromator | Czerny-Turner with 1800 lines/mm grating, 230 nm blaze |
| Optical System | Double-beam |
| Detector | Solid-state CCD array |
| Background Correction | D₂ lamp + Self-absorption (AAS) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | < 0.05 nm |
| Spectral Bandwidth | 0.1/0.2/0.4/0.7/1.4 nm (auto-switchable) |
| Flame Cu Detection Limit | < 0.006 µg/mL |
| GF Cd Detection Limit | ≤ 1.0 pg |
| Flame Cu Precision (RSD) | < 0.8% |
| GF Cd Precision (RSD) | ≤ 2% (auto-injection), ≤ 5% (manual) |
| Temperature Control Range (GF) | Room temp – 3000 °C |
| Max GF Ramp Rate | 3000 °C/s |
| Safety Compliance | Integrated gas leak, flame status, cooling water flow, and graphite furnace temperature monitoring per IEC 61010-1 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BIO3000 |
| Price Range | USD 14,000–42,500 |
| Instrument Type | Portable |
| Test Organism | Bioluminescent Bacteria |
| Operating Temperature | 0–40 °C |
| Reagent Storage Temperature | Room Temperature |
| Coefficient of Variation (Repeatability) | <5% |
| Sample Throughput | 1 sample per run |
| Assay Time | <25 min |
| Detection Range | 0–65,535 RLU |
| Inhibition Range | 0–100% (linear response 10–90%) |
| Spectral Sensitivity | 320–1100 nm |
| Power Supply | 220 V ±10%, 50 Hz |
| Weight | 450 g |
| Dimensions | 90 × 220 × 40 mm |
| IP Rating | IP65 |
| Battery Life | >12 h continuous operation |
| Data Storage | 4 GB internal (expandable), >100,000 records |
| Connectivity | USB, Bluetooth, Wi-Fi |
| Software Platform | Android-based embedded OS with guided workflow |
| Compatible Strains | *Vibrio qinghaiensis* sp.-Q67, *Photobacterium phosphoreum*, or *Vibrio fischeri* (ISO 11348-3 compliant) |
| Bacterial Lyophilized Stock Stability | 12 months at –18 °C |
| Environmental Operating Conditions | 5–40 °C, 10–90% RH (at 25 °C) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CEMS-V100 |
| Price Range | USD 42,000–70,000 (FOB) |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ≤±5% F.S. (range >200 μmol/mol) |
| Repeatability | RSD ≤3% |
| Response Time | <5 min |
| Stability | ≤20% (emission standard ≥100 μmol/mol) |
| Analytes | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Total Hydrocarbons (NMHC), BTEX (Benzene, Toluene, Ethylbenzene, Xylenes), Volatile Organic Compounds (VOCs) |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Detection Range | 0–50 / 500 / 5000 ppm (as CH₄, adjustable) |
| LOD | 0.05 ppm (0–50 ppm range) |
| Zero Drift | ±1% F.S. or 0.1 ppm |
| Span Drift | ±1% F.S. or 0.1 ppm |
| Analysis Cycle | 1 min (standard) |
| Sample Flow Rate | 600 mL/min (analysis) |
| Calibration Interval | User-configurable (e.g., daily, weekly, monthly) |
| Output Interface | Modbus TCP, 4–20 mA, RS232, RS485 |
| Operating Environment | 0–45 °C, <90% RH (non-condensing) |
| Storage | −20–60 °C, <90% RH |
| Required Gases | High-purity H₂, zero-air, N₂, CH₄ calibration gas |
| Power Supply | 220 V AC, 50/60 Hz, 1500 W |
| Enclosure | 19″ rack-mount industrial cabinet |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | EDX 2000A |
| Pricing | Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | EDX 3200S PLUS C |
| Form Factor | Benchtop/Floor-Standing |
| Application Domain | Food Safety Testing |
| Elemental Range | S to U |
| Quantification Range | 0.03 ppm – 99.99% |
| Energy Resolution | ≤125 eV (FWHM at Mn Kα) |
| Repeatability | <10% RSD (at 0.2 mg/kg Cd) |
| Detector | FAST-SDD (Silicon Drift Detector with Fast Pulse Processing) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | EDX-V |
| Form Factor | Benchtop/Floor-standing |
| Instrument Type | Conventional EDXRF |
| Application Scope | General-purpose coating & thin-film analysis |
| Compliance | ASTM B568, ISO 3497, DIN EN ISO 3497, IPC-4552 (ENIG), IPC-4556 (ENEPIG) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | EDX2000H |
| Form Factor | Benchtop / Floor-Standing |
| Application Type | General-Purpose |
| Elemental Range | S (16) – U (92) |
| Quantification Range | 0.1 ppm – 99.99 wt% |
| Energy Resolution | ≤125 eV (Mn Kα) |
| Repeatability | ≤0.05% RSD (for major elements >96 wt%) |
| Detector | Si-PIN Semiconductor Detector |
| Operating Temperature | 15–30 °C |
| Sample Chamber Dimensions | 460 × 298 × 98 mm |
| Instrument Dimensions | 550 × 410 × 320 mm |
| Weight | 45 kg |
| Power Supply | AC 220 V ±5 V, recommended with line conditioner |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | EDX3000 |
| Form Factor | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | S (16) to U (92) |
| Quantitative Range | 1 ppm – 99.9 wt% |
| Energy Resolution | 125 eV (at Mn Kα) |
| Repeatability | ≤0.05% RSD (for major elements >96 wt%) |
| Detector | Si-PIN semiconductor detector |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HM-5000P |
| Pricing | Available Upon Request |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) & Direct Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | HM-7000P |
| Pricing | Available upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HM-8000P |
| Instrument Type | Portable |
| Detection Methods | Anodic Stripping Voltammetry (ASV) & Colorimetric Spectrophotometry |
| Supported Elements | 9 standard (expandable to 12) |
| Electrochemical Scan Modes | Linear Sweep Voltammetry (LSV), Square Wave Voltammetry (SWV), Differential Pulse Voltammetry (DPV) |
| Operating System | Android-based embedded OS |
| Display | 7-inch capacitive touchscreen |
| Data Connectivity | Cloud synchronization, OTA firmware updates, wireless method library updates |
| Compliance | EPA Methods 7063, 7472 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HM3000P |
| Pricing | Available Upon Request |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detection Time | <5 min (typical), as fast as 30 s |
| Detection Limits | 0.1–0.5 ppb (depending on element) |
| Upper Detection Range | 10–60 ppm |
| Electrode Type | Disposable or Reusable Screen-Printed Electrodes (SPE) / Mercury-Film Electrodes |
| Power Supply | Rechargeable Li-ion battery (≥10 h continuous operation, ≥100 assays) |
| IP Rating | IP67 |
| Display | Sunlight-readable transflective LCD |
| Data Storage | 2000 measurement records |
| Connectivity | USB 2.0, Bluetooth (optional thermal printer support) |
| Software | PC-based analytical suite with ASV method programming, polarogram visualization, calibration management, and audit-trail-enabled data export (CSV, PDF) |
| Compliance | EPA Methods 7063, 7472 |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | ICP 2060T (Petrochemical-Optimized) |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | 0.5–10 ppb |
| Precision (RSD) | ≤1.5% |
| Long-Term Stability (2 h) | ≤2.0% |
| Wavelength Range | 190–500 nm (with 3600 l/mm grating) |
| Optical Resolution | ≤0.008 nm |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Domestic |
| Model | ICP-3000 |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limits | Zn 213.856 nm: 0.47 µg/L |
| Ni 231.604 nm | 1.73 µg/L |
| Mn 257.61 nm | 0.18 µg/L |
| Cr 267.716 nm | 1.18 µg/L |
| Cu 324.754 nm | 1.1 µg/L |
| Ba 445.403 nm | 0.1 µg/L |
| Precision (RSD) | <0.5% |
| Long-Term Stability (2 h RSD) | <1.0% |
| Wavelength Range | 165–900 nm |
| Optical Resolution | 6.8 pm @ 200 nm |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | ICP-MS 2000 Series |
| Mass Analyzer Type | Quadrupole Mass Spectrometer |
| Intended Use | Laboratory-Based Elemental Analysis |
| Regulatory Compliance | Meets or exceeds GB/T 35791–2018 (Chinese National Standard for ICP-MS Performance Verification) |
| Software Platform | Windows 2000/XP/Vista/7 (32-bit & 64-bit) Compatible Control System |
| Sample Introduction | Integrated Peltier-Cooled Glass Cyclonic Spray Chamber (–20 °C to +20 °C), One-Piece Quartz Concentric Torch, Open-Access Nebulizer Assembly |
| Vacuum Interface | Dual-Conical Interface with Removable Sampling Cone (1.1 mm orifice) and High-Salt/High-Sensitivity Skimmer Cone Options (0.75 mm standard) |
| Ion Optics | Asymmetrically Mounted Extraction & Deflection Lenses, ETP Dual-Mode Detector (Analog/Digital Switching), Computer-Controlled Auto-Tuning |
| Automation | 250-Position Autosampler (Ethernet-Controlled, Positioning Accuracy < 500 µm) |
| RF Generator | Solid-State Frequency-Tunable Generator with Cold Plasma Mode, Collision/Reaction Cell Mode, and Standard Mode Support |
| Collision/Reaction Cell | Hexapole-Based, H₂/He Mixed-Gas KED Mode Enabled |
| Detection Modes | Full-Scan, Peak-Hopping, Time-Resolved Analysis (TRA) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | ICP2060T |
| Price Range | USD 70,000 – 100,000 |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | 1–10 µg/L (ppb) for most elements |
| Precision (Short-Term) | RSD < 0.5% |
| Stability (2-hr) | RSD < 1.0% |
| Wavelength Range | 165–900 nm |
| Optical Resolution | < 0.0068 nm @ 200 nm |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AFS200 |
| Instrument Type | Dual-Channel Atomic Fluorescence Spectrometer |
| Element Coverage | As, Sb, Bi, Hg, Se, Te, Pb, Sn, Ge, Zn, Cd (11 elements) |
| Detection Limit (DL) | As/Sb/Bi ≤ 0.01 ng/mL |
| Precision (RSD) | ≤ 1% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Gas Control | Integrated solenoid valve manifold (AFS200N/P) or dual-channel Mass Flow Controller (MFC), resolution 1 mL/min (AFS200T/S) |
| Hydride Generation | Discontinuous flow with dual peristaltic pumps (N/T) or sequential injection combined with peristaltic pump (P/S) |
| Atomizer | Shielded quartz tube with low-temperature flame ignition |
| Optical System | Non-dispersive design with high-efficiency photomultiplier tube (PMT) detection |
| Software | Proprietary Windows-based AFS workstation with GLP-compliant audit trail, auto-calibration, and report generation |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AFS200T |
| Pricing | Available upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CEMS-X100 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±10% |
| Repeatability | ≤2% |
| Response Time | As low as 5 minutes (dependent on flue gas conditions) |
| Long-term Stability | ≤5% |
| Measurable Elements | Pb, Cu, Cd, Cr, Zn, Ni, and over 20 other heavy metals |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | CS-188 |
| Pricing | Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | EAD-100 Series |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Measurement Principle | Optical Light Scattering |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | EAQM-100S |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Measured Parameters | SO₂, NO₂, CO, O₃, PM₂.₅, PM₁₀, Temperature, Relative Humidity, Wind Speed, Wind Direction, Atmospheric Pressure, TVOC |
| Measurement Principles | Optical Scattering (PM), Electrochemical Sensors (CO, NO₂, SO₂, O₃), Photoionization Detection (TVOC), Capacitive/Thermal Hygrometry & Thermistor-based Temperature Sensing, Ultrasonic Anemometry (Wind), Piezoresistive Barometry |
| Calibration | Dual-mode (Automated Zero/Span Drift Compensation + Manual Field Calibration via Remote Command) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | EDX 3000 PLUS |
| Form Factor | Benchtop |
| Application Scope | General-Purpose |
| Elemental Range | S (16) to U (92) |
| Detection Limit | ppm-level |
| Quantification Range | 0.0001 wt% to 99.99 wt% |
| Energy Resolution | 125 eV (at Mn Kα) |
| Detector | FAST-SDD (25 mm² active area) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | EDX 3200S PLUS |
| Configuration | Benchtop/Floor-standing |
| Industry Application | Energy & Petrochemicals |
| Energy Resolution | 125 eV |
| Detector | FAST-SDD |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | EDX 4500 |
| Form Factor | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | Na (11) to U (92) |
| Quantitative Range | 0.1 ppm – 99.99% (matrix- and element-dependent) |
| Energy Resolution | ≤125 eV at Mn Kα |
| Detector | FAST-SDD (Silicon Drift Detector) |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | EDX 4500A |
| Configuration | Benchtop/Floor-standing |
| Application Scope | General-purpose Inorganic Elemental Analysis |
| Automation | 23-position Automatic Sample Changer Integrated |
| Light Element Capability | Optimized for Na–Cl (Z = 11–17) via Intelligent Vacuum System |
| Regulatory Context | Compliant with ISO 8258 (control charting), ASTM E1621 (XRF for metals), and GB/T 176–2017 (cement analysis) |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Type | Benchtop/ Floor-Standing ED-XRF Spectrometer |
| Model | EDX 4500H |
| Element Range | Na–U |
| Concentration Range | 0.1 ppm – 99.99 wt% |
| Energy Resolution | 125 eV (Mn Kα) |
| Repeatability | RSD ≤ 0.05% for major elements (>96 wt%) |
| Detector | FAST-SDD (Silicon Drift Detector) |
| Tube Voltage | 5–50 kV |
| Tube Current | 50–1000 µA |
| Measurement Time | 30–200 s |
| Sample Chamber Dimensions | 320 × 100 mm |
| Instrument Dimensions | 660 × 510 × 350 mm |
| Weight | 65 kg |
| Operating Environment | 15–30 °C, 35–70% RH |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | EDX 600 PLUS |
| Configuration | Benchtop / Floor-Standing |
| Application Type | General-Purpose |
| Elemental Range | S (16) to U (92) |
| Quantitative Range | 0.1% – 99.9% |
| Energy Resolution | ≤125 eV (Mn Kα) |
| Repeatability | <5% RSD |
| Detector | FAST-SDD (Silicon Drift Detector) |