SkyRay Instrument
Filter
Showing 61–90 of 94 results
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LC-310 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0–10 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Sample Vial Capacity | 108 positions (2 mL vials) |
| Injection Volume Range | 0–20 µL |
| Column Oven Temperature Range | Ambient +5°C to 80°C |
| UV-Vis Wavelength Range | 190–680 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OES8000S |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | ≤0.001 wt% |
| Repeatability | ≤1.5% RSD |
| Stability | ≤1.2% RSD |
| Wavelength Range | 140–680 nm |
| Optical Resolution | 10 pm |
| Spectrometer Design | Paschen-Runge mounting with 400 mm Rowland circle diameter |
| Grating | 3600 lines/mm concave holographic grating |
| Detector | High-performance linear CMOS array |
| Excitation Source | Fully digital plasma spark source with HEPS (High-Energy Pre-Spark) technology |
| Analysis Time | <40 s per sample |
| Argon Consumption | Optimized low-flow gas system |
| Operating Temperature | 15–30 °C |
| Relative Humidity | ≤70% RH |
| Power Requirement | 220 V ±5%, 50 Hz, single-phase, ground resistance <1 Ω |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | POW-I |
| Pricing | Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Domestic |
| Model | SEE100 |
| Configuration | Benchtop/Floor-standing |
| Application Domain | Soil & Atmospheric Environmental Monitoring |
| Elemental Range | S (16) to U (92) |
| Quantification Range | 0.1 ppm – 99.99% (matrix-dependent) |
| Energy Resolution | ≤125 eV at Mn Kα |
| Detector | FAST-SDD (Silicon Drift Detector) |
| Excitation Source | Adjustable X-ray Tube (5–55 kV, 50–1000 µA) |
| Measurement Time | 60–300 s per sample |
| Simultaneous Elements | ≥30 |
| Sample Forms | Solid, Powder, Slurry, Liquid |
| Compliance | HJ 780–2015, GBZ 115–2002, ISO 12847, ASTM D6388 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SMART 100 PLUS |
| Form Factor | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | S (16) to U (92) |
| Quantification Range | 0.1 ppm – 99.9 wt% |
| Energy Resolution | 125 eV (Mn Kα) |
| Repeatability | ≤0.03% RSD (for major elements >96 wt%) |
| Detector | FAST-SDD (25 mm² active area) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TDM3000-MS |
| Mass Range | m/z 10–2000 amu |
| Sensitivity | >0.4 pg (positive ion mode), >0.8 pg (negative ion mode) |
| Analyzer Type | Single Quadrupole |
| Application Domain | Therapeutic Drug Monitoring (TDM)–Specific Clinical Use |
| Sample Throughput | Up to 150 samples per day |
| Online Sample Cleanup | Integrated protein/ phospholipid/salt removal via dual-column extraction and valve-switching architecture |
| Extraction Column Lifetime | ≥2000 injections |
| Ionization Source | Electrospray Ionization (ESI) |
| Detection Mode | Quantitative and Qualitative Analysis of Small Organic Molecules in Human Serum |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Thick 800A |
| Pricing | Available Upon Request |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TIC-600 |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Benchtop Laboratory System |
| Maximum Pump Pressure | 42 MPa |
| Flow Rate Range | 0–10 mL/min |
| Eluent Flow Rate Range | 0–10 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Operating Temperature Range | 5–60 °C |
| Temperature Stability | ≤ 0.2 °C/h |
| Eluent Concentration Range | 0–40 mmol/L (Na₂CO₃/NaHCO₃) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TIC-660 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | Universal Multi-Analyte Ion Analysis |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TVOC-800 |
| Detection Principle | Photoionization Detection (PID) |
| Instrument Type | Portable |
| Typical Configuration | TVOC Analyzer |
| Detection Range | 0–20 / 200 / 1000 ppm (field-selectable) |
| Resolution | ≤10 ppb |
| Accuracy | ≤±10% of Full Scale |
| Response Time | ≤20 s |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | UPY-6800 |
| Quotation | Upon Request |
| Mass Analyzer Type | Single Quadrupole |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Sample Introduction | Integrated Pyrolyzer Module (Thermal Desorption/Pyrolysis Interface) |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Analyzer |
| Configuration | TVOC Detection System |
| Detection Principle | Flame Ionization Detection (FID) + Photoionization Detection (PID) |
| FID Range | 0–50,000 ppm |
| PID Range | 0–4,000 ppm |
| FID Resolution | 0.5 ppm |
| PID Resolution | 0.1 ppm |
| FID Accuracy | ±5% of reading or ±3 ppm (whichever is greater) |
| PID Accuracy | <±5% |
| FID T90 Response Time | ≤3.5 s |
| PID T90 Response Time | <3 s |
| Zero Recovery Time | ≤4 s |
| Battery Life | ≥10 h |
| H₂ Cylinder Capacity | 100 mL @ 20 MPa |
| H₂ Runtime | >12 h (full charge) |
| Ignition System | Dual spark igniters |
| Displayed Parameters | Flame temperature, battery level, pump power, H₂ pressure |
| CPU | Octa-core Cortex-A53 (64-bit, 2.3 GHz) |
| Memory | 64 GB ROM + 4 GB RAM, expandable via 128 GB microSD |
| OS | Android 9.0 |
| Connectivity | USB Type-C, Wi-Fi 802.11 a/b/g/n, Bluetooth 4.0 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WAOL2000 |
| Pricing | Upon Request |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | WDX200 |
| Pricing | Available Upon Request |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | WDX400 |
| Pricing | Upon Request |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | WDX4000 |
| Price Range | USD 210,000 – 280,000 |
| Instrument Type | Sequential Scanning |
| X-ray Tube Power | 4 kW |
| Elemental Coverage | Standard: C–U (Z = 6–92) |
| Enhanced | Be–U (Z = 4–92) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole LC-MS |
| Mass Range | m/z 10–2000 amu |
| Sensitivity | ≥50:1 S/N (RMS) for 10 pg reserpine in ESI+ mode |
| Resolution | Unit mass resolution (peak width at 10% height: ≤0.7 amu) |
| Mass Accuracy | ≤±0.20 amu |
| Ionization Sources | ESI (standard), APCI & APPI (optional) |
| Polarity Switching Time | ≤20 ms (−10 kV to +10 kV) |
| Vacuum System | High-speed imported turbomolecular pump |
| Software | ChemAnalyst v3.x with 21 CFR Part 11 compliance modules, audit trail, user privilege management, and GLP/GMP-ready workflow support |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LIBS8000 |
| Instrument Type | Handheld |
| Weight | 1.9 kg |
| Display | 5.0-inch Touchscreen |
| IP Rating | IP54 |
| Laser Wavelength | 1064 nm |
| Plasma Temperature | >10,000 K |
| Spatial Resolution | <1 µm |
| Spectral Range | Typically 190–900 nm (standard configuration) |
| Language Support | 8 languages (English, Chinese, French, Italian, Spanish, German, Indonesian, Polish) |
| Data Integration | MES/LIMS/ERP-compatible via Ethernet/USB/Wi-Fi |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | microTyper MS |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Mass Resolution | R ≥ 500 |
| Sensitivity | Signal-to-Noise Ratio ≥ 100 |
| Mass Stability | ≤ 800 ppm |
| Mass Accuracy | ≤ 500 ppm |
| Mass Range | > 16,000 u |
| Repeatability | ≤ 0.06% |
| Ion Source | Matrix-Assisted Laser Desorption/Ionization (MALDI) |
| Detector | Large-Area Microchannel Plate (MCP) |
| Laser | Long-Life Nitrogen UV Laser (1–60 Hz Tunable) |
| Acquisition Rate | Up to 3 GHz sampling rate |
| Vacuum System | 320 L/s Turbo Molecular Pump |
| Sample Target | 96-well Reusable Stainless Steel Plate with 6 QC Spots |
| Exhaust Treatment | Triple-Stage Sterilization Unit |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Laboratory Ion Chromatograph |
| Model | TIC-680 |
| Configuration | Benchtop Dual-Channel IC System with Electrolytic Eluent Generator and Multi-Detector Compatibility |
| Intended Use | General-purpose anion/cation analysis, speciation coupling (AFS/ICP/ICP-MS), and regulatory-compliant water testing per GB 5750.10–2023 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (PRC) |
| Model | UPY-100 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose RoHS Compliance Testing |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Oven Ramp Rate | 0–120 °C/min |
| Oven Cooling Rate | <10 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1250 mL/min, Electronic Flow Control (EFC) |
| Carrier Gas Pressure Range & Control | 0–100 psi, Electronic Pressure Control (EPC) at Column Inlet |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–1250 mL/min |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VEM-100 |
| Instrument Type | Portable |
| Measurement Principle | Optical Transmission (Light Absorption) |
| Max. Permissible Error | ±2.0% |
| Zero Drift | ≤1.0% |
| Span Drift | ≤1.0% |
| Repeatability | ≤1.0% |
| Light Absorption Coefficient (k) Resolution | 0.001 m⁻¹ |
| Opacity (N) Resolution | 0.01% |
| Operating Temperature Compensation | Integrated |
| Optional NOₓ Module | Available |
| Remote Control Interface | Industrial-grade Wi-Fi (up to 100 m) & Bluetooth |
| Data Output | Real-time cloud upload, QR code sharing, thermal printing |
| Dimensions | 470 × 195 × 280 mm |
| Weight | ~7.5 kg |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | VOC-2000 |
| Detection Principle | Photoionization Detection (PID) |
| Instrument Type | Portable |
| Typical Configuration | Total VOC (TVOC) Analyzer |
| Measurement Range | 0–40,000 ppm (isobutylene equivalent) |
| Resolution | 0.1 ppm |
| Accuracy | ±10% of reading |
| Response Time (T90) | <4 seconds |
| Operating System | Android-based embedded OS |
| Display | 4-inch capacitive touchscreen |
| Compliance | HJ 1019–2019 (China Technical Guideline for Sampling VOCs in Soil and Groundwater) |
| Data Export | USB mass storage & wireless (Wi-Fi/Bluetooth) |
| Connectivity | Built-in Wi-Fi, Bluetooth 4.2, QR code sharing |
| Power | Rechargeable Li-ion battery (≥8 h typical operation) |
| Environmental Rating | IP54 |
| Weight | ≤420 g |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Detection Principle | Flame Ionization Detection (FID) |
| Configuration | Total VOC Analyzer |
| Measurement Range | 0–500,000 ppm |
| Resolution | 0.5 ppm |
| Accuracy | ±0.5% of reading |
| Response Time (T90) | 3.6 s |
| Compliance | GB 37822–2019, HJ 733–2014 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | VOC-3800 |
| Detection Principle | Flame Ionization Detection (FID) & Photoionization Detection (PID) |
| Instrument Type | Portable |
| Configuration | Dual-sensor VOC Analyzer (FID + PID) |
| Response Time | FID: ≤3.5 s, PID: ≤3.5 s |
| Safety Certification | Intrinsically Safe (Ex ib IIB T4 Gb) |
| Hydrogen Supply | Solid-state hydrogen storage cartridge (rechargeable with deionized water) |
| Compliance | GB 20950–2020, GB 20951–2020, GB 20952–2020, HJ 733–2014, GB 37822–2019, HJ 1230–2021 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | VOC-5000 |
| Detection Principle | Flame Ionization Detection (FID) & Photoionization Detection (PID) |
| Instrument Type | Portable |
| Typical Configuration | Total Volatile Organic Compounds (TVOC) Analyzer |
| Detection Range (FID) | 0–50,000 ppm |
| Detection Range (PID) | 0–4,000 ppm |
| Resolution | 0.1 ppm (PID), 0.1 ppm (FID) |
| Accuracy | ±5% of reading or ±3 ppm (whichever is greater) |
| Detection Limit (FID) | 0.5 ppm |
| Detection Limit (PID) | 0.1 ppm |
| T90 Response Time (FID) | ≤3.5 s |
| T90 Response Time (PID) | <3 s |
| Zero Recovery Time (FID) | ≤4 s to 10% of baseline |
| H₂ Cylinder Capacity | 100 mL at 20 MPa |
| H₂ Runtime | >12 h per full charge |
| Battery Life | 10 h (typical operation) |
| Ignition System | Dual spark igniters |
| Displayed Parameters | Flame temperature, battery level, pump power, H₂ pressure |
| CPU | Octa-core ARM Cortex-A53 (64-bit, 2.3 GHz) |
| Memory | 64 GB ROM + 4 GB RAM, expandable via 128 GB microSD |
| OS | Android 9.0 |
| Connectivity | USB Type-C, Wi-Fi 802.11 a/b/g/n, Bluetooth 4.0 |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | VOC-9000 |
| Instrument Type | Portable |
| Detection Principle | Infrared Absorption Imaging (Mid-Wave IR, 3.2–3.5 µm spectral band optimized for hydrocarbon VOCs) |
| Target Analytes | Volatile Organic Compounds (VOCs), including but not limited to methane, propane, butane, benzene, toluene, xylene, and C2–C4 aliphatic/aromatic hydrocarbons |
| Detection Range | Quantitative leak rate from 0.001 mL/s to >100 mL/s (per ISO 21876:2022 Annex B reference methodology) |
| Thermal Sensitivity (NETD) | ≤0.01 °C @ 30 °C |
| Spatial Resolution | ≤1.3 mrad (with 24° lens) |
| Minimum Detectable Leak Rate | ≤0.001 mL/s (as verified per HJ 733–2014 protocol using calibrated methane/propylene challenge gas) |
| Response Time | <4 s (T90, per IEC 60079-29-1) |
| Operating Temperature Range | –20 °C to +50 °C |
| Enclosure Rating | IP54 |
| Explosion Protection | Ex ic nC op is IIC T4 Gb / Ex ic nC op is IIIC T130°C Db (IEC 60079-0, -11, -15, -31) |
| Weight | 2.5 kg (including battery and standard lens) |
| Data Storage | Internal SD card (up to 512 GB, FAT32 formatted), supporting synchronized thermal + visible image pairs and time-stamped video (.mp4, H.264) |
| Software Compatibility | SkyRay LDAR Pro v3.2 (Windows 10/11), supports ASTM D7039–23 compliant reporting, US EPA OOOOa audit-ready export, and GLP-compliant metadata logging (operator ID, GPS coordinates, timestamp, ambient conditions) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VOCs-800P |
| Detection Target | NMHC (Non-Methane Hydrocarbons) |
| Detection Limit | ≤0.07 mg/m³ |
| Response Time | ≤60 s |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WDX3300 |
| Pricing | Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | WM-3000P |
| Instrument Type | Portable |
| Measurement Principle | Colorimetric Spectrophotometry (DAP/DPD-based for chlorine species |
| Measured Parameters | Free Chlorine, Total Chlorine, Chemical Oxygen Demand (COD) |
| Measurement Range | 0.02–1000 mg/L |
| Accuracy | ≤ ±5% of reading |
| Repeatability | ≤ ±5% RSD |
| Resolution | 0.01 ppm |
| Limit of Detection | 0.01 ppm |
| Power Supply | Two 1.5 V AA batteries (72 h continuous operation) or 220 VAC-to-3 VDC adapter |
| Data Storage | Internal non-volatile memory with timestamped records (date, time, parameter ID, sample ID, result) |
| Ingress Protection | IP41 (dust-protected, vertically dripping water resistant) |
| Compliance | Designed to support ASTM D1253, ISO 7393-2 (chlorine), and ISO 6060 (COD) methodology alignment |