Thermo Fisher
Filter
Showing 661–690 of 1004 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Assembled (China) |
| Model | Thermo Scientific Apreo 2 SEM |
| Price | Upon Request |
| Resolution (30 kV) | 0.7 nm (STEM) |
| Resolution (15 kV) | 0.5 nm (with sample-stage deceleration) |
| Resolution (1 kV, 10 mm WD) | 1.0 nm (with deceleration) |
| Resolution (500 V) | 0.8 nm (with deceleration) |
| Landing Energy Range | 20 eV – 30 keV |
| Sample Stage | 5-axis motorized, ±90° tilt, 110 × 110 mm² XY travel |
| Max Sample Weight | 5 kg |
| Standard Detectors | ETD, T1, T2, T3, IR-CCD, Nav-Cam+ |
| Optional Detectors | DBS, LVD, DBS-GAD, STEM 3+, RGB-CLD, EDS, EBSD, WDS, Raman, EBIC |
| ColorSEM Technology | Real-time EDS-based elemental mapping integrated into imaging interface |
| SmartAlign & FLASH | Automated beam alignment, stigmation, and focus |
| Low Vacuum Mode | Optional, 10–500 Pa chamber pressure |
| Chamber Dimensions | 340 mm internal width, 12 ports, supports up to three EDS detectors (two at 180°), co-planar EDS/EBSD mounting orthogonal to tilt axis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestically Assembled (China) |
| Model | Apreo ChemiSEM |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific AQ4700 |
| Instrument Type | Online |
| Biological Indicator | Bioluminescent Bacteria |
| Detection Time | 5 min |
| Compliance | ISO 11348 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific AQ4700 |
| Instrument Category | Online |
| Biological Indicator | Bioluminescent Bacteria |
| Detection Time | 5 min |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Thermo Scientific AquaClear |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Parameter | Turbidity |
| Compliance | Meets and exceeds USEPA Method 180.1 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | 3110TP |
| Application | Online Water Quality Monitoring |
| Measured Parameter | Total Phosphorus (TP) |
| Measurement Range | 0–1 / 0–2 / 0–10 / 0–50 mg/L |
| Accuracy | <5% for standard solutions |
| Detection Limit | 0.01 mg/L |
| Resolution | < ±5% of Full Scale |
| Instrument Type | Online Automated Analyzer |
| Compliance Context | Designed for continuous operation in compliance with ISO 15681-1 (Water quality — Determination of phosphorus — Part 1: Spectrophotometric determination after digestion) and supports GLP/GMP data integrity requirements via audit-trail-capable software |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | 3110TP |
| Measurement Parameter | Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Acid Digestion + Molybdenum Blue Colorimetry |
| Measurement Ranges | 0–1 / 0–2 / 0–10 / 0–50 mg/L as P |
| Accuracy | <5% for standard solutions |
| Detection Limit | 0.01 mg/L |
| Resolution | < ±5% of Full Scale (F.S.) |
| Repeatability | <5% of reading |
| Data Storage Capacity | 20,000 records with auto-rollover |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Enclosure Rating | IP66 / NEMA 4X |
| Dimensions (W×H×D) | 510 × 775 × 330 mm |
| Weight | 40 kg (instrument only) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | AquaEZ 3130 COD |
| Instrument Type | Online Analyzer |
| Wavelength | 450 nm |
| Measurement Range | 10–4000 mg/L |
| Accuracy | ±10% of reading (for samples >100 mg/L) |
| Repeatability | <5% of reading |
| Limit of Detection | 15 mg/L |
| Analysis Time | 45 minutes per cycle |
| Batch Capacity | 30 samples per 30-minute interval |
| Zero Drift | ≤5 mg/L |
| Protection Rating | IP65 / NEMA 4 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W×H×D) | 510 × 775 × 330 mm |
| Weight | 40 kg (excluding reagents) |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Output Interfaces | Dual 4–20 mA analog outputs, RS232 standard, RS485 optional |
| Digital I/O | 2 digital inputs, 8 digital outputs |
| Calibration Modes | Automatic scheduled, manual, and external-triggered |
| Data Storage | Up to 2 years of time-stamped measurement history with event tagging (M = maintenance, D = fault, C = calibration) |
| Display | Color LCD screen showing real-time results, calibration curves, and historical trends |
| Digestion Conditions | 165 °C, duration adjustable from 10–30 minutes |
| Measurement Modes | Continuous, periodic, timed, or external signal-triggered |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific AquaOZ |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Application | Real-time Dissolved Ozone Monitoring in Process Water Streams |
| Electrode Technology | Clark-type Amperometric Three-Electrode Sensor System |
| Controller Platform | AquaPro Multi-Channel Process Controller (up to 4 channels) |
| Data Logging Capacity | 1,000 data points with USB export |
| Firmware Update | USB-port field-upgradable |
| Language Support | 6 languages including English, Chinese, Spanish, French, German, and Portuguese |
| Membrane Assembly | Pre-filled, disposable membrane cap with electrolyte |
| Temperature Compensation | High-accuracy integrated Pt1000 RTD sensor |
| Housing Material Options | PVC, PVDF, 316L SS, and Hastelloy C-276 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific AquaPro RDO |
| Instrument Category | Online Dissolved Oxygen Analyzer |
| Measurement Principle | Fluorescence Quenching |
| Range | 0–20 ppm / 0–200% saturation |
| Accuracy | ±0.1 ppm (≤8 ppm), ±0.2 ppm (8–20 ppm) |
| Repeatability | ±5% |
| Detection Limit | 0.01 ppm or 0.1% saturation |
| Maintenance Interval | Fluorescence Cap Replacement Every 2 Years |
| Certification | CE Marked |
| Regulatory Compliance | Designed for compliance with ISO 5814:2012 (Water quality — Determination of dissolved oxygen — Electrochemical probe method), ASTM D888-22 (Standard Test Methods for Dissolved Oxygen in Water), and supports GLP/GMP data integrity requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | AquaPro |
| Instrument Category | Online Water Quality Analyzer |
| Measurement Flexibility | Configurable Input Channels for Any Parameter |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Thermo Scientific AquaPro |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | DataStick Digital Sensor |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific AquaSensors |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AquaTurb / AquaSol |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Turbidity, Suspended Solids (SS) Concentration |
| Optical Method | ISO 7027-compliant Nephelometric & Backscatter Detection |
| Light Source | Infrared LED (850 nm) |
| Detection Angles | 90° and 180° |
| Output | Digital (RS-485, Modbus RTU), Optional 4–20 mA Analog |
| Temperature Compensation | Integrated Pt1000 sensor |
| Enclosure Rating | IP68 |
| Cleaning Option | Optional Automatic Wiper or Air-Pulse Self-Cleaning Module |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model Numbers | CK50920, CK50921, CK50922 |
| Price Range | USD $2,600 – $6,500 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | ARGUS VI |
| Instrument Category | Stable Gas Isotope Ratio Mass Spectrometer |
| Measurement Precision | High Precision |
| Analyte Range | Noble Gases (He, Ne, Ar, Kr, Xe) |
| Mass Range | Full Mass Range for Noble Gases (m/z 2–132) |
| Resolution | High Mass Resolution (M/ΔM > 300 at 10% valley) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ARL 9900 |
| Instrument Type | Floor-standing |
| X-ray Tube Power Options | 1.2 kW, 2.5 kW, 3.6 kW, 4.2 kW |
| Elemental Range | Be to U (with appropriate analyzing crystals) |
| Sample Introduction | 8-position, 12-position or 98-position autosampler |
| Weight | ~750 kg |
| Max. Power Consumption | 4.8 kVA |
| Configuration | Scanning-type WDXRF spectrometer with optional simultaneous XRD channel |
| Brand | Thermo Fisher |
|---|---|
| Origin | France |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Powder X-ray Diffractometer |
| Model | ARL EQUINOX 100 |
| Power Stability | < 0.0001 (unitless relative stability, typical for high-stability X-ray tube power supply) |
| Detector | Integrated EQUINOX curved position-sensitive detector (CPSD) |
| Cooling | Fully integrated internal water-cooling system |
| Sample Handling | Optional 6-position autosampler, transmission powder holders, thin-film accessories |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ARL EQUINOX Pro |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 3000 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | ARL EQUINOX Pro Vertical X-ray Diffractometer |
| Instrument Type | X-ray Crystal Orientation Analyzer |
| Angular Accuracy | ±0.0001° |
| Resolution | FWHM < 0.026° (2θ, LaB₆ (110)) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | ARL EQUINOX Pro Vertical X-ray Diffractometer (XRD) |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Floor-standing |
| Excitation Source | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Grating Line Density | 1080, 1667, and 2160 lines/mm |
| Wavelength Range | 200–760 nm |
| Number of Analytical Channels | 80 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | ARL iSpark Plus Series OES |
| Pricing | Available upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | ARL Optim’X |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 50 W / 200 W (equivalent via UCCO™ technology) |
| Elemental Range | F to U (73 elements) |
| Analysis Mode | Simultaneous (fixed-channel) and Sequential (scanning) |
| Cooling | Air-cooled, no external water circulation required |
| Sample Handling | Standard 1-position manual loader |
| Software | Thermo Scientific OXSAS with OptiQuant™ quantitative package |
| Compliance | Designed to meet ASTM E1361, ISO 2936, ISO 8258, and GLP/GMP data integrity requirements (21 CFR Part 11-ready audit trail) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ARL PERFORM'X Sequential |
| Price Range | USD 135,000–205,000 (FOB) |
| Instrument Type | Sequential WDXRF |
| X-ray Tube Power | 1.5 kW (ARL PERFORM'X 1500W), 2.5 kW (ARL PERFORM'X 2500W), 4.2 kW (ARL PERFORM'X 4200W) |
| Elemental Range | F (Z=9) to U (Z=92), plus C (Z=6) |
| Detection Limit | Sub-ppm for most elements in optimized matrices |
| Angular Positioning Accuracy | ≤0.0005° (Moiré fringe encoder-based goniometer) |
| Sample Form | Solids (pressed pellets, fused beads), Liquids (sealed cells), Powders, Coatings |
| Automation | Integrated XYZ sample changer with up to 120-position capacity |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China-manufactured under Thermo Fisher global quality standards) |
| Model | ARL PERFORM'X |
| Power Options | 1500 W, 2500 W, 4200 W |
| Optical Design | Ultra-Close Coupling Optics (UCCO) |
| Angular Positioning | Gearless digital goniometer with Moiré fringe optical encoder |
| Software Platform | OXSAS v8.x with QuantAS™, UniQuant™, and PetroilQuant™ application packages |
| Compliance | Designed to support GLP/GMP workflows, ASTM E1361, ISO 2936, ISO 8258, USP <233>, and FDA 21 CFR Part 11 audit-trail readiness |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | ARL X'TRA Companion |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | ARL™ iSpark Plus Series |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Armadillo PCR Plate |
| Pricing | Upon Request |
