Thermo Fisher
Filter
Showing 631–660 of 1004 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | 5028i |
| Measurement Principle | Beta-ray Attenuation |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Measurement Range | 0–10 mg/m³ (0–10,000 µg/m³) |
| Sampling Flow Rate | 1 m³/h (16.67 L/min) |
| Detection Limit | <1 µg/m³ (24-hr, 2σ) |
| Data Output Interval | 1 s |
| Flow Stability | ±2% accuracy, <5% deviation |
| Regulatory Certification | US EPA EQPM for PM₁₀ (EQPM1102-150) and PM₂.₅ (EQPM0609-183) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | Thermo Scientific 5030 |
| Measurement Principle | Simultaneous Optical Scattering (880 nm IR LED) and Beta Attenuation (¹⁴C source, <100 µCi) |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Detection Limit | 0.5 µg/m³ (1-hour resolution) |
| Range | 0–1,000 µg/m³ and 0–10,000 µg/m³ (auto-ranging) |
| Flow Rate | 1 m³/h (16.7 L/min) |
| 24-hr Drift | ±0.002% full scale |
| Accuracy | ±2 µg/m³ for concentrations <80 µg/m³ |
| Light Source | Infrared LED (6 mW, 880 nm) |
| Beta Source | Carbon-14 (<100 µCi) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | 5030 (SHARP) |
| Measurement Method | Beta-ray Absorption + Light Scattering |
| Measured Parameters | PM₁₀ / PM₂.₅ |
| Concentration Range | 0–1,000 µg/m³ and 0–10,000 µg/m³ |
| LOD | <0.5 µg/m³ @ 2σ (1-hr resolution) |
| Accuracy | ±5% vs. 24-hr FRM |
| Time Resolution | 1 min (data updated every 4 s) |
| Drift | ≤0.02% per day |
| Flow Rate | 16.67 L/min |
| Radiation Source | ¹⁴C, 3.7 MBq (100 µCi), t₁/₂ = 5700 yr |
| Optical Source | IR LED, 880 nm, 6 mW |
| Operating Temperature | −30 to +60 °C |
| Power | Instrument: 100–240 VAC, 50/60 Hz, ≤330 W |
| Pump | 220–240 VAC, 50/60 Hz, 100 W |
| Dimensions (Instrument) | 483 × 311 × 330 mm (W×H×D) |
| Weight (Instrument) | 22.5 kg |
| Weight (Pump) | 8.1 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | 5030iQ and 5014iQ |
| Measured Parameters | PM₁₀, PM₂.₅, PM₁.₀ |
| Compliance | HJ 653–2021, US EPA EQPM-0807-195, EN 12341:2014, ISO 20581:2022 |
| Detection Principle | Synchronized Hybrid Ambient Real-time Particulate (SHARP) — dual-method integration of beta-ray absorption and nephelometry |
| Calibration | Dynamic digital filter-based continuous mass calibration |
| Display | 7-inch color touchscreen with localized UI |
| Filter Tape Capacity | ≥1500 measurement points (≥12 months at standard sampling intervals) |
| Warm-up Time | <30 minutes |
| Software | ePort Remote Management Suite with audit trail, predictive diagnostics, and GLP-compliant data logging |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Flame Ionization Detection (FID) |
| Configuration | Multi-range VOC Analyzer |
| Measurement Range | 1, 10, 100, 1000, 5000, 10000 ppmC |
| Resolution | 0.05 ppm carbon |
| Accuracy | ±2% of reading or ±0.1 ppm (whichever is greater) |
| Response Time | 15 s (to 90% of full scale, 1 s averaging time) |
| Noise | <0.025 ppmC (10 s averaging) |
| MDL | 0.05 ppm carbon |
| Zero Drift (24 h) | <0.50 ppmC |
| Sample Flow Rate | 0.75–1.5 LPM |
| Fuel Gas | 25 mL/min high-purity H₂ or 110 mL/min H₂/He mixture |
| Temperature Control Zones | Four independent zones |
| Diagnostic Capability | Real-time operational status monitoring |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Thermo Scientific 55i |
| Detection Principle | Gas Chromatography (GC) with Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Emission Monitor |
| Configuration | Dual-Channel GC-FID for Simultaneous CH₄ and NMHC Quantification |
| Detection Range | 0–5/50/500 ppm |
| Resolution | 0.050 ppm CH₄ |
| Accuracy | ±2% of reading or ±50 ppb (whichever is greater) |
| Response Time (t₉₀) | 70 s |
| Zero Noise | 0.025 ppm RMS (300-s averaging) |
| Span Drift (24 h) | <2% of full scale |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific 55i |
| Detection Principle | Gas Chromatography (GC) with Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Emission Monitor |
| Configuration | Dual-Channel GC-FID for Simultaneous CH₄ and NMHC Quantification |
| Measurement Ranges | 0–5/50/500 ppm |
| Resolution | 0.050 ppm CH₄ |
| Accuracy | ±2% of reading or ±50 ppb (whichever is greater) |
| Response Time (t₉₀) | 70 s |
| Zero Noise | 0.025 ppm RMS (300-s averaging) |
| MDL | 0.050 ppm CH₄ |
| Span Drift (24 h) | <2% of full scale |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Analyzer |
| Configuration | Multi-component VOC Analyzer |
| Detection Range | 0–50 ppm / 500 ppm / 5,000 ppm / 50,000 ppm / 500,000 ppm (as methane) |
| Resolution | 50 ppb |
| Accuracy | ±1% of full scale or 0.1 ppm (whichever is greater) |
| Response Time | <1 minute for NMHC analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Model | Thermo Scientific 5800 |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Multi-component VOC Analyzer |
| Detection Range | 0–50 ppm / 500 ppm / 5,000 ppm / 50,000 ppm / 500,000 ppm (as methane) |
| Resolution | 50 ppb |
| Accuracy | ±1% of full scale or ±0.1 ppm (whichever is greater) |
| Response Time | <1 minute for NMHC analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | 5800-GO |
| Price Range | USD $42,000–$70,000 (FOB) |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Portable |
| Configuration | Multi-component VOC Analyzer |
| Measurement Ranges | 0–50, 500, 5,000, 50,000 ppm |
| Resolution (as propane) | 30 ppb |
| Response Time | ≤2 min (methane/non-methane hydrocarbons) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Thermo Scientific 5900 VOCs |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Continuous Analyzer |
| Detection Range | NMHC 0–5 ppm |
| Accuracy | ≤ ±10% |
| Response Time | ≤ 15 min |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | 5900-A |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Detection Limit | ≤30 ppb (as methane) |
| Compliance | ASTM D6348, EPA Method 25A, HJ 1012-2018, HJ 38-2017 |
| Installation Form | 19-inch rack-mountable chassis |
| Control System | Integrated EPC (Electronic Pressure Control) for carrier gas and sample flow |
| Data Output | Modbus TCP, RS-232/485, Analog 4–20 mA |
| Software | Thermo Scientific Chromeleon™ CDS (with 21 CFR Part 11 compliance option) |
| Operating Environment | 5–40 °C, <90% RH non-condensing |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | 5900-A |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 6000 VOC |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Multi-Component VOC CEMS |
| Measurement Range | 0–5000 ppm (as methane or NMHC) |
| Accuracy | ±1% F.S. or ±0.1 ppm |
| Response Time | ≤60 s (for NMHC) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | 6000 VOC |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Multi-component VOC CEMS |
| Measurement Range | 0–5000 ppm (as methane or NMHC) |
| Accuracy | ±1% F.S. or ±0.1 ppm |
| Response Time | ≤60 s (for NMHC) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | 3423 / 3429 |
| Price Range | USD $14,000 – $70,000 |
| Chamber Material | Polished Stainless Steel |
| CO₂ Range | 0–20% |
| CO₂ Sensor Options | TC or IR |
| Humidity Control | Passive (Water Pan) |
| Temperature Range | Ambient +5°C to 50°C |
| Internal Volume | 184 L (6.5 cu ft) |
| Interior Dimensions (D×W×H) | 50.8 × 54.1 × 68.1 cm |
| Exterior Dimensions (L×W×H) | 63.5 × 100.3 × 66 cm |
| Net Weight | 166 kg |
| Electrical Requirement | 230 V, 50/60 Hz |
| Certifications | UL, CUL, CE |
| Data Output | Optional 4–20 mA analog signal |
| HEPA Filtration | Rapid 100-level air purification in <5 min |
| Alarm System | Audible/visual alerts for temperature deviation, CO₂ high/low, door open, low water, filter life, and cold ambient conditions |
| User Interface | Graphical “Message Center” with configurable access codes, calibration prompts, and maintenance scheduling |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ADR-1500 |
| Pricing | Upon Request |
| Measurement Principle | Optical Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Enclosure Rating | IP65 |
| Power Options | AC, External DC, Internal Rechargeable Battery |
| Communication Interfaces | USB, RS-232, 0–5 V / 4–20 mA Analog Output, Optional Wireless Module |
| Environmental Compensation | Integrated Temperature, Relative Humidity, and Barometric Pressure Sensors with Active Heating |
| Flow Control | True Volumetric Flow Control via Digital Feedback Loop Using Calibrated Critical Orifice and Differential Pressure Sensor |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific ADR-1500 |
| Measurement Principle | Optical Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀, PM₂.₅, PM₄, PM₁ |
| Measurement Range | 0.001–400 mg/m³ (Auto-ranging) |
| Detection Limit | 0.1 µg/m³ |
| Sampling Flow Rate | 1.0–3.5 L/min |
| Flow Stability | ±2% of reading or ±0.005 mg/m³ (whichever is greater), 1-s averaging |
| Accuracy | ±5% of reading (traceable to SAE test standards) |
| Precision | ±2% (1 s), ±0.5% (10 s), ±0.2% (60 s) |
| Scatter Coefficient Range | 1.1×10⁻⁶ to 0.6 m⁻¹ (@ λ = 880 nm) |
| Aerodynamic Particle Size Cut Points | 1.0–10 µm (with optional cyclone cutters: GK2.05 for PM₄–PM₁₀ |
| Operating Environment | IP65-rated weatherproof enclosure |
| Power Options | AC, external DC, or internal rechargeable battery (up to 100 h continuous operation) |
| Data Connectivity | Wireless/3G, USB, RS-232, analog output |
| Onboard Display | Dual-line LCD showing real-time concentration, start time, date, average concentration, and runtime |
| Temperature & Humidity Compensation | Integrated heated sensor assembly with RH/T correction |
| True Volumetric Flow Control | Enabled via digital feedback from barometric pressure, temperature, and calibrated orifice ΔP sensors |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Industrial Online Conductivity Analyzer |
| Model | Thermo Scientific Alpha CON1000 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Industrial Online Conductivity/Resistivity Analyzer |
| Model | Thermo Scientific Alpha RES1000 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Alpha Conductivity Electrode |
| Pricing | Available Upon Request |
| Cell Constants Available | 0.01 cm⁻¹, 0.1 cm⁻¹, 0.3 cm⁻¹, 1.0 cm⁻¹ |
| Compatible Transmitter | CON2000 only (for specific part numbers) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific Alpha |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Thermo Scientific Alpha pH/ORP |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | Thermo Scientific AnalogPlus |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AnalogPlus pH/ORP |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | APDPHYL500 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific APDSOIL |
| Instrument Category | Online Analyzer |
| Measurement Principle | Ultraviolet Fluorescence (UVF) |
| Measurement Ranges | 0.1–10 ppm, 0.2–100 ppm, 1–1000 ppm |
| Detection Limits | 0.1 ppm, 0.2 ppm, 1 ppm |
| Accuracy | ≤3% |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | APIX |
| Detection Targets | Conventional + Specialty Gas Trace Impurities |
| Detection Method | Atmospheric Pressure Ionization Mass Spectrometry (API-MS) |
| Mass Range | 1–300 AMU |
| Ion Source | Atmospheric Pressure Ionization (API) |
| Background Level | <1 ppt |
| Detector | 100 MHz Pulse-Counting Electron Multiplier |
| Noise Floor | 10 counts per 10⁶ pulses |
| LOD | <10 ppt (compound-dependent) |
| Analysis Time per Component | <1 s |
| Typical Cycle Time | <5 s |
| Flow Path Switching Time | <15 min (to sub-ppb stability) |
| Compatible Bulk Gases | UHP H₂, N₂, Ar, He |
| Dimensions (δQ) | 1.9 m (H) × 0.7 m (W) × 0.65 m (D) |
| Dimensions (Quattro) | 1.9 m (H) × 2.1 m (W) × 0.65 m (D) |
| Communication Protocols | OPC UA, Modbus TCP/RTU, PROFIBUS DP, Siemens 3964R, DDE, EtherNet/IP |
| Software Platform | Thermo Scientific GasWorks® v5.x |
| Compliance | Designed for ISO 9001-certified manufacturing |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APIX |
| Detection Range | 1–300 AMU |
| Brand | Thermo Fisher |
|---|---|
| Origin | Czech Republic |
| Model | Apreo 2 |
| Instrument Type | Floor-standing SEM |
| Electron Gun | Schottky Field Emission |
| Microscope Class | Ultra-High-Resolution FE-SEM |
| Magnification Range | 5× to 1,000,000× |
| Accelerating Voltage | 200 V – 30 kV |
| Maximum Sample Width | 340 mm (horizontal chamber dimension) |
| Expandable Chamber Ports | 12 total, including 3 EDS-compatible ports (2 at 180° opposing positions) |
| Stage | 5-axis motorized eucentric stage (X = 110 mm, Y = 110 mm, Z = 65 mm, Tilt = −15° to +90°, Rotation = 360° continuous) |
| Standard Detectors | In-chamber Everhart-Thornley SE detector (ETD), in-column backscattered electron detector (T1), in-column secondary electron detector (T2) |