Thermo Fisher
Filter
Showing 901–930 of 995 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | ULT2586-10HD-V / ULT3280-10HD-V |
| Capacity | 702 L (24.8 cu ft) / 889 L (31.4 cu ft) |
| Internal Dimensions (H×W×D, mm) | 1283×876×616 / 1283×993×693 |
| External Dimensions (H×W×D, mm) | 1975×1092×835 / 1975×1219×835 |
| Electrical | 230 V / 50 Hz |
| Current / Fuse Rating | 12 A / 16 A |
| Net Weight | 358 kg / 478 kg |
| Temperature Range | –86 °C typical operating setpoint |
| Controller | Microprocessor-based with LED display, password-protected parameter access |
| Power Management | Integrated PLUS system with boost/buck voltage regulation, low-voltage compensation, and battery-backed real-time clock & alarm memory |
| Data Logging | Built-in 7-day temperature recorder compliant with 21 CFR Part 11 audit trail requirements |
| Door System | Dual independent door hinges per inner door, CryoLatch™ integrated handle with optional dual-lock capability |
| Insulation | High-density polyurethane foam (≥150 mm thick), vacuum-panel-enhanced perimeter |
| Airflow Design | Stand-off feet, rear pressure-equalization port, cleanable condenser filter |
| Remote Interface | Dry-contact alarm outputs, analog voltage output (0–5 V), RS-485 port for BMS integration |
| Compliance | Designed to meet ISO 13485 manufacturing standards |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Models | REL1204V / REL3004V / REL7504V |
| Price Range | USD 13,500 – 20,300 (FOB USA) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | REB3004V / REB404V / REB1204V |
| Temperature Range | 1–8 °C |
| Control Accuracy | ±0.1 °C |
| Display Resolution | 0.1 °C |
| Compressor | 1/4 HP Industrial Hermetic |
| Insulation | CFC-free High-Density Polyurethane Foam |
| Refrigerant | R134a |
| Power Supply | 230 V, 50 Hz (EU plug) |
| External Dimensions (L×W×H) | 74.3 × 61 × 186.9 cm |
| Internal Volume | 326 L |
| Interior Drawer Count | 6 Stainless Steel Full-Extension Drawers |
| Compliance | UL, CUL, CE, AABB, ANRC, FDA 21 CFR Part 11–Ready (with optional audit trail software) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Global Manufacturing (Non-China) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Orbital Roller Mixer |
| Model | Thermo Scientific Roller Mixer |
| Pricing Range | USD 1,400 – 2,800 (FOB) |
| Timer Range | 0–999 min or Continuous Operation |
| Rotational Speed | 1–80 rpm |
| Temperature Control Range | 4 °C to 60 °C |
| Platform Configuration | Single-roll axis, dual-tier stackable design |
| Compliance | CE, ISO 9001 certified manufacturing |
| Brand | Thermo Fisher |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RT Basic Series Magnetic Stirrers |
| Instrument Type | Magnetic Stirrer |
| Maximum Stirring Volume | 2 L / 4 L / 5 L |
| Speed Range | 150–2500 rpm |
| Temperature Control | None |
| Brand | Thermo Fisher |
|---|---|
| Origin | South Korea |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Magnetic Stirrer |
| Model | RT Touch Series |
| Maximum Stirring Volume | 4 L (170 mm plate) / 5 L (220 mm plate) |
| Speed Range | 30–2000 rpm |
| Control Interface | Digital Touchscreen with Soft-Start Logic |
| Plate Diameter Options | 170 mm / 220 mm |
| Magnetic Coupling Strength | High-Efficiency Permanent Magnet Array |
| Base Material | Chemically Resistant Polymer Housing with Aluminum Heating-Free Plate |
| Accessories | Dual Anti-Slip Silicone Pads Included |
| Compliance | CE, IEC 61010-1, RoHS |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | RT-Elite |
| Price | Upon Request |
| Heating Plate Material | Aluminum |
| Stirring Speed Range | 50–1200 rpm |
| Temperature Range | 5–350 °C |
| Max. Vessel Capacity | 4 L |
| Max. Load Weight | 18 kg |
| Power Supply | 220–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 16.5 × 28.4 × 9.9 cm |
| Heating/Stirring Plate Radius | 13.5 cm |
| Net Weight | 3.4 kg |
| Temperature Setting Accuracy | ±1 °C |
| Temperature Display Resolution | 0.1 °C |
| Setpoint Increment | 1 °C |
| Interface | Triple independent LCD displays (temperature, speed, timer) |
| Connectivity | RS232 port for data logging |
| Safety Features | HOT TOP overtemperature alarm (>50 °C), independent adjustable overtemperature protection, instant stir bar stop upon vessel removal, anti-tamper lock function |
| Brand | Thermo Fisher |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RT2 Advanced Hotplate Stirrer |
| Instrument Type | Magnetic Stirrer |
| Maximum Stirring Volume | 20 L |
| Speed Range | 30–2000 rpm |
| Temperature Control Range | RT + 50 °C to 350 °C |
| Heating Plate Surface | 140 mm diameter, ceramic-coated aluminum |
| Max. Surface Temperature | 450 °C |
| Over-Temperature Protection | Yes, with visual alarm indicator |
| Temperature Control Algorithm | PID microprocessor-based |
| Temperature Control Modes | 5 programmable modes (Optimized, Rapid, Gradual, Setpoint, User-defined with auto-tuning) |
| Dual Independent Timers | Yes |
| Real-Time Display | Simultaneous setpoint and actual values for speed and temperature |
| Adjustable Temperature Limit | Yes |
| Optional Accessories | Slip-resistant heating bath, transparent safety shield |
| Temperature Monitoring | External Pt100 probe compatible |
| Brand | Thermo Fisher |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Equipment |
| Model | RT2 Basic Hotplate Stirrer |
| Instrument Type | Magnetic Stirrer |
| Maximum Stirring Volume | 20 L |
| Speed Range | 50–2000 rpm |
| Temperature Control Range | RT + 50 °C to 350 °C |
| Heating Plate Material | Aluminum with Ceramic Coating |
| Plate Diameter | 140 mm |
| Maximum Plate Surface Temperature | 450 °C |
| Over-Temperature Protection | Yes, with Visual Alarm Indicator |
| Optional Accessories | Anti-Slip Water Bath, Transparent Safety Shield, Support Rod for Sensor Mounting |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Single-Channel Electronic Pipette Controller |
| Model | Scientific S1 |
| Automation Level | Electric |
| Channels | 1 |
| Volume Range | 0.1–5 mL |
| Accuracy | ±1% |
| Power Source | Rechargeable Lithium-Ion Battery |
| Compatibility | Glass and Plastic Serological Pipettes (1–50 mL) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Deployment Options | On-premises or Cloud (managed by Thermo Fisher or customer-owned infrastructure) |
| Core Modules | Laboratory Execution System (LES), Electronic Lab Notebook (ELN), Scientific Data Management System (SDMS), Chromatography & Mass Spectrometry Integration (with Chromeleon CDS), Third-Party Portal, MES/ERP Interoperability, ASTM D6299-23a AQC Automation, Role-Based Training & Access Control |
| Regulatory Compliance | FDA 21 CFR Part 11, ISO/IEC 17025, GMP, GLP |
| Mobile Support | Native tablet application for LES execution and sample handling |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Models | FD910, FD950, FD960, FD900, ID900, PD900 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop & In-line Process |
| Application Focus | Petroleum, Petrochemical, Chemical, LNG, and Power Generation |
| Density Range (Liquid) | 0–2100 kg/m³ |
| Density Range (Gas) | 0–1000 kg/m³ (FD900/ID900), 0–250 kg/m³ (PD900) |
| Accuracy (Liquid) | ±0.1 kg/m³ |
| Repeatability (Liquid) | 0.02 kg/m³ |
| Temperature Compensation | Integrated 4-wire PT100 (1/3 DIN) |
| Operating Temp (Liquid) | −50°C to +180°C |
| Operating Temp (Gas) | −200°C to +200°C |
| Pressure Rating | Up to 170 bar (FD900), 150 bar (ID900), 100–150 bar (PD900) |
| Enclosure Rating | IP65 / NEMA 4X |
| Hazardous Area Certifications | ATEX Ex ia IIC T4/T6, CSA Class I Div 1 Groups B, C, D, IECEx, NACE MR0175/ISO 15156 compliant |
| Output Options | 4–20 mA + HART (HME900), Frequency/Modulated Current (CM515), Dual-Channel PT100 |
| Calibration | NIST-traceable, performed in ISO/IEC 17025-accredited laboratory |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | Thermo Scientific Savant SpeedVac DNA130 Integrated Vacuum Concentrator |
| Pricing | Upon Request |
| Maximum Vacuum | <10 Torr (13 mbar / 1.3 kPa) |
| Temperature Range | Ambient (17–32°C) to 65°C in 5°C increments |
| Heating Time | 1 min – 9 h 59 min or continuous |
| Run Time | 1 min – 9 h 59 min |
| Sample Capacity | 36 × 1.5–2.0 mL tubes (RD36 rotor), 72 × 0.5 mL tubes, or 2 microplates |
| Chamber Material | PTFE-coated aluminum |
| Vacuum Pump | Oil-free diaphragm pump |
| External Trap | Optional ammonium hydroxide neutralization trap (ANT-100 + ANS121) and radioactive chemical purification columns available |
| Certifications | UL (US/Canada), CE |
| Electrical Requirements | 230 V, 50 Hz, 6 A |
| Plug Type | Schuko CEE 7-7 |
| Dimensions (L×W×H) | 29 × 64 × 31 cm (11.5 × 25 × 12 in) |
| Net Weight | 39 kg (86 lb) |
| Shipping Weight | 48 kg (105 lb) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SKU |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | SOLA II |
| Measurement Principle | Pulsed UV Fluorescence (PUVF) |
| Detection Range | 0.25–9000 ppm S (standard), down to 25 ppb S (Trace variant) |
| Response Time | T90 ≤ 3–5 min |
| Sample Types | Liquid hydrocarbons (e.g., gasoline, diesel, naphtha), gaseous streams (e.g., flare gas, refinery off-gas) |
| Output Signals | 4–20 mA, Modbus RTU/TCP, semi-continuous I/O |
| Density Compensation | Yes (via external densitometer input, e.g., Sarasota FD910) |
| Auto-Calibration | Yes |
| Diagnostic Capabilities | Valve leak detection, UV lamp intensity feedback control, PMT health monitoring, real-time system diagnostics |
| Compliance | ASTM D5453, ISO 20846, USP <621>, GLP/GMP-ready data integrity features (audit trail, user access control, electronic signatures via SOLAWeb) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | SOLA II |
| Measurement Principle | Pulsed Ultraviolet Fluorescence (PUVF) |
| Detection Range | SOLA II: 0–5 ppmS to 0–5000 ppmS |
| SOLA Trace | 0–2 ppmS to 0–5 ppmS |
| SOLA Flare DI | 10 ppmS to 95% S |
| Repeatability | ±2% FS (1 injection/min), ±1% FS (2 injections/min) |
| Response Time (T90) | 3–5 min |
| Communication | 4–20 mA, Modbus RTU/ASCII/TCP, RS-232/RS-485, Ethernet (TCP/IP) |
| Certifications | ATEX Zone 1/2, IECEx, CSA Class I Div 1/2, NEC Class I Div 1/2, CE Mark |
| Environmental Operating Range | 12–40 °C |
| Power | 110/220 VAC, 50/60 Hz, 2000 W |
| Sample Requirements | Liquid or gas (ASTM D5453/D6667 compliant) |
| Auto-Diagnostics | Valve leak detection, flow monitoring, lamp/PMT health tracking, density compensation interface |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model Series | Sorvall LYNX |
| Pricing | Available Upon Request |
| Maximum RCF | 100,605 × g |
| Maximum Capacity | 6 L |
| Available Models | LYNX4000, LYNX6000 |
| Rotor Locking | Auto-Lock™ Quick-Release System |
| Rotor Recognition | Automatic RFID-Based Identification |
| Control Interface | Full-Color LCD Touchscreen |
| Rotor Material | Fiberlite® Carbon-Fiber Composite |
| Biosafety Certification | Third-Party Validated ClickSeal® Biocontainment Lid |
| Compatible Rotors | 19 Configurations (including LEX™ Design) |
| Throughput Options | 6 × 1 L Bottles |
| Acceleration/Deceleration | Optimized for Rapid Ramp Times Without Sample Disturbance |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | LYNX 4000 |
| Maximum Speed | 24,000 rpm |
| Maximum RCF | 100,605 × g |
| Maximum Capacity | 4 × 1000 mL (with A27-8×50 rotor) |
| Dimensions (H×W×D, lid open) | 93 cm × 80.5 cm × 70 cm |
| Rotor Interface | Auto-Lock® self-locking mechanism |
| Rotor Recognition | Auto-ID® instant rotor identification |
| Safety System | ClickSeal® biocontainment lid (third-party certified) |
| Rotor Material | Fiberlite® carbon-fiber composite |
| Available Rotors | 19 configurations |
| Acceleration/Deceleration | Optimized for rapid ramp-up and controlled coast-down |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Benchtop Centrifuge |
| Model | ST1/ST1R Plus |
| Speed Range | Up to 15,200 rpm |
| Max RCF | 25,830 × g |
| Max Capacity | 4 × 400 mL (with TX-400 rotor) |
| Dimensions | 36.2 × 56.6 × 66 cm |
| Rotor Options | 15 interchangeable rotors including horizontal, fixed-angle, and microcentrifuge configurations |
| Compliance | CAMR-certified ClickSeal™ biocontainment system |
| Safety | Auto-Lock™ III rotor auto-engagement, electric lid latch, SMARTSpin™ imbalance compensation |
| Energy Efficiency | Up to 40% lower energy consumption vs. conventional benchtop centrifuges for standard blood and conical tube protocols |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Benchtop Centrifuge |
| Model | Sorvall ST4/ST4R Plus |
| Centrifuge Category | High-Speed Benchtop Centrifuge (10,000–30,000 rpm) |
| Rotor Type | Fixed-Angle & Swinging-Bucket Configurations |
| Maximum Capacity | 6 × 100 mL (with F20-6×100 rotor) |
| Max Relative Centrifugal Force (RCF) | 25,830 × g (fixed-angle, with 30 × 2 mL rotor) / 5,590 × g (swinging-bucket, with BIOShield1000 A rotor) |
| Dimensions | 690 mm × 566 mm × 362 mm |
| Energy Efficiency | Up to 40% lower energy consumption vs. conventional benchtop centrifuges for standard tube processing |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Floor-standing centrifuge |
| Model | Sorvall ST4F / ST4R F Plus |
| Centrifuge Category | High-speed centrifuge (10,000–30,000 rpm) |
| Maximum Capacity | 4 × 1000 mL (with TX-1000 rotor) |
| Maximum Speed | 15,200 rpm (with Microliter 30 × 2 rotor) |
| Maximum RCF | 25,830 × g (with Microliter 30 × 2 rotor) |
| Dimensions | 83.5 × 56.6 × 69 cm |
| Rotor Options | 12 interchangeable rotors |
| Control Interface | High-contrast LCD with programmable memory for up to 6 protocols |
| Safety Certifications | CAMR™-certified ClickSeal™ biocontainment system, IEC 61010-1, EN 61326-1 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | Sorvall ST4R Plus Benchtop Centrifuge |
| Maximum Speed | 15,200 rpm (25,830 × g) |
| Rotor Compatibility | H-Flex HS4 rotor (supports 15 mL & 50 mL tubes, microtiter plates, and blood collection tubes), Fiberlite carbon fiber rotors, up to 24 rotor types |
| Safety Certification | CAMR-certified ClickSeal biocontainment lid |
| Rotor Locking | Auto-Lock™ quick-release system (≤3 s) |
| Control Interface | Full-color touchscreen with multi-step programmability |
| Refrigeration | Yes (ST4R Plus is refrigerated model) |
| Max Capacity | 4 × 400 mL or 4 × 1000 mL (depending on rotor configuration) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Sorvall™ BIOS 16 |
| Instrument Type | Floor-standing centrifuge |
| Speed Range | High-speed (up to 5400 rpm) |
| Cooling Function | Refrigerated centrifuge |
| Configuration | Horizontal rotor centrifuge |
| Separation Level | Cell/bacterial |
| Max Capacity | 8 × 2000 mL |
| Max Speed | 5400 rpm |
| Max RCF | 8500 × g |
| Dimensions (L×W×H) | 900 mm × 816 mm × 1015 mm |
| Weight | 465 kg |
| Temperature Range | −20 °C to +40 °C (adjustable in 1 °C increments) |
| Certifications | UL, CE, FDA-listed |
| Drive Technology | DuraFlex high-torque brushless motor |
| Control Interface | Centri-Touch™ touchscreen |
| Auto-ID | Yes |
| Auto-Door & Auto-Lid | Yes |
| ACE™ (Automatic Centrifugation Efficiency) Integration | Yes |
| Pre-cooling | Yes |
| Imbalance Tolerance | 125 g (opposite loads) |
| Step Runs | Up to 30 speed/time/temperature triplets, max 3 steps per program |
| Warranty | 2 years (unit), 5 years (powertrain & refrigeration) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | Thermo Scientific Stellar |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Producer |
| Origin Category | Domestic |
| Model | STP TDE |
| Instrument Type | Upright |
| Effective Volume | ≥422 L (accommodates 300 × 2" cryoboxes) |
| Inner Chamber Dimensions (mm) | ≥1301 × 452 × 719 |
| External Dimensions (mm) | ≥1981 × 584 × 977 |
| Power Supply | 230 V / 50 Hz |
| Rated Power Consumption | ≥1357 W |
| Energy Consumption | as low as 9.2 kWh/day (at –80°C setpoint, 20°C ambient) |
| Noise Level | ≤50 dB(A) |
| Refrigerant | Hydrocarbon (HC-290/HC-600a blend), SNAP & EU F-gas compliant |
| Insulation | Non-HFC polyurethane foam, SNAP & EU F-gas compliant |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Super Nuova+ |
| Instrument Type | Magnetic Hotplate Stirrer |
| Maximum Stirring Volume | 4 L / 6 L |
| Speed Range | 50–1500 rpm |
| Temperature Control Range | 30–300 °C / 400 °C / 450 °C |
| Panel Options | Ceramic or Anodized Aluminum |
| Standard Accessories | External Stainless Steel PT1000 Temperature Probe, Support Rod, Clamp Holder, LED Display, Integrated StirTrac Technology, Over-Temperature Alert (>50 °C Surface), Splash Guard (Optional), Assorted Stir Bars |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TEOM 1405-D |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™) |
| Measured Parameters | PM₁₀, PM₂.₅, and PM<sub>coarse</sub> (PM₁₀ − PM₂.₅) |
| Data Averaging Intervals | 10 s to 24 h |
| Mass Concentration Range | 0–1,000,000 µg/m³ |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg) |
| Mass Measurement Uncertainty | ±0.75% |
| Sampling Flow Rates | Fine channel: 3.0 L/min |
| Coarse channel | 1.67 L/min |
| Bypass | 12.0 L/min |
| Operating Ambient Temperature | −40 °C to +60 °C (sensor/control unit maintained at 2–40 °C) |
| Communication Interfaces | Ethernet, USB, RS-232, RS-485, FTP server |
| Analog I/O | 8 configurable 0–1 V or 0–5 V outputs |
| Power Requirements | Main unit: 100–240 VAC, 440 VA, 47–63 Hz |
| Vacuum pump | 120 VAC/60 Hz (4.25 A) or 240 VAC/50 Hz (2.25 A) |
| Dimensions (W×D×H) | 42.5 in × 47.5 in × 73.8 in (1080 mm × 1207.5 mm × 1875 mm) |
| Weight | 18 kg |
| Compliance | CE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | TEOM 1405-F |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Regulatory Designation | U.S. EPA Equivalent Method for PM2.5 (EQPM-0609-181) |
| Particle Size Fractions | PM2.5, PM10, PM1, TSP |
| Data Interfaces | Ethernet, USB, RS232, RS485, FTP Server |
| User Interface | Touchscreen LCD |
| Flow Control | Activol™ Dynamic Mass Flow Control |
| Integrated System | Filter Dynamic Measurement System (FDMS), Sensor Module, and Control Unit in Single Enclosure |
| Environmental Compensation | Heated Sample Inlet with Relative Humidity and Temperature Regulation |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific TEOM 1405DF / 1405F |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Measured Parameters | PM₁₀, PM₂.₅, TSP, PM₁.₀ |
| Measurement Range | 0–1,000,000 µg/m³ |
| Detection Limit | 0.1 µg/m³ |
| Sampling Flow Rate | 3 L/min (main), 12–13.67 L/min (bypass) |
| Flow Stability | ±75% for mass measurement |
| Data Storage Capacity | 5,000,000 records |
| Reporting Interval | 6-minute updates with 1-hour rolling averages |
| Accuracy | ±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg) |
| Resolution | 0.1 µg/m³ |
| Calibration Traceability | NIST-traceable mass and flow standards |
| Compliance | Designed to meet U.S. EPA Reference Method EQPM-0899-007 (PM₂.₅), EQPM-0899-008 (PM₁₀), ISO 20581, and applicable EN 12341 requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Series | Thermo Scientific TEOM |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Measurement Range | 0–1,000,000 µg/m³ |
| Measurement Interval | Real-time mass measurement with 6-minute data updates and 1-hour rolling averages |
| Sample Flow Rate | 3 L/min (1405F) |
| Fine-mode flow | 3 L/min / Coarse-mode flow: 1.67 L/min (1405DF) |
| Detection Limit | 0.1 µg/m³ |
| Flow Stability | ±75% during mass measurement |
| Data Storage Capacity | 5,000,000 records |
| Accuracy | ±2.0 µg/m³ (1-hr average), ±1.0 µg/m³ (24-hr average for 1405F) |
| Resolution | 0.1 µg/m³ |
| Bypass Flow | 12 L/min (1405DF), 13.67 L/min (1405F) |