Thermo Fisher
Filter
Showing 871–900 of 1004 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AQ4500 |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Orion AquaMate 7100 |
| Optical Design | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 325–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 5.0 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Wavelength Scanning | Automatic |
| Display | 7-inch High-Resolution Touchscreen |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Orion AquaMate 8100 |
| Optical Design | Double-Beam |
| Detector | CCD Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 2.0 nm |
| Stray Light | <1.0%T @ 198 nm (KCl), <0.05%T @ 220 nm (NaI), <0.03%T @ 340 nm (NaNO₂) |
| Automation Level | Automatic Wavelength Selection |
| Display | 7-inch High-Resolution Touchscreen |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | CFAN10 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | CFSS12 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | ISE Series |
| Instrument Category | Multi-Ion Analyzers |
| Compliance | ASTM D1129, ISO 10523, USP <798>, EPA Method 300.0, EN ISO 10304-1 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ROSS pH |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | Orion Star LogR Series |
| Model | LogR |
| Measurement Principle | Potentiometric pH with integrated LogR temperature sensing via pH electrode membrane resistance |
| pH Range | –2.000 to 19.999 |
| Resolution | 0.001 pH (selectable) |
| Accuracy | ±0.002 pH |
| Calibration Points | 1–5-point, auto-buffer recognition (USA/NIST, EURO/DIN) |
| mV Range | ±1999.9 mV |
| mV Accuracy | ±0.2 mV or ±0.05% of reading, whichever is greater |
| Temperature Range | 0–100 °C (manual or LogR-compensated) |
| LogR Temp Accuracy | ±0.1 °C (10–100 °C) |
| Resistance Range | 0–6000 MΩ |
| Resistance Resolution | 0.1 MΩ (<2000 MΩ), 1 MΩ (≥2000 MΩ) |
| Data Storage | 1000 readings with timestamp |
| Interface | RS232 |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | Orion Star LogR Series |
| Model | LogR pH/ISE |
| Measurement Principle | Potentiometric (Glass Electrode + ISE) with LogR™ Membrane Resistance-Based Temperature Sensing |
| Compliance | ASTM D1293, ISO 10523, USP <791>, EPA Method 150.1, GLP-Ready |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Star RDO |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Reference/Equivalent Method PM Sampler |
| Models | Partisol 2000i (single-channel), Partisol 2000i-D (dual-channel) |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15 L/min (2000i-D), Coarse Particle Flow Rate: 1.67 L/min (2000i-D) |
| Total Flow Range | 5–17 L/min (2000i) |
| Data Storage | 86 days @ 5-min intervals, 32 filter records |
| Operating Temperature | −40 °C to +50 °C |
| Power | 1.1 A @ 240 VAC |
| Dimensions (H×W×D) | 1620 mm × 1175 mm × 927.5 mm (base unit) |
| Weight | 37.2 kg (2000i), 38.6 kg (2000i-D) |
| Compliance | U.S. EPA RFPS-0498-117 (PM₂.₅), RFPS-1298-126 (PM₁₀), RFPS-0509-175 (Coarse PM) |
| Filter Format | Dual 47 mm filter holders (2000i-D), single 47 mm holder (2000i) |
| Cut Points | PM₂.₅ (cyclone or impactor), PM₁₀ (inlet), Coarse PM (PM₁₀–PM₂.₅ via virtual impactor in 2000i-D) |
| Interface | RS-232, USB, Ethernet |
| Software | iPort™ Communications Suite, Activol™ Flow Management System |
| Safety Certification | CE EN 61326 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Models | Partisol 2025i, Partisol 2025i-D |
| Flow Control | Activol Mass Flow Controller |
| Volume Flow Range | 1.67–15 L/min |
| Flow Accuracy | ±2% of setpoint |
| Operating Temperature | −40 °C to +50 °C |
| Power Requirement | 1.5 A @ 240 VAC |
| Data Storage | 86 days at 5-minute intervals + 32 filter records |
| Compliance | U.S. EPA Reference Methods RFPS-0498-118 (PM₂.₅), RFPS-1298-127 (PM₁₀), RFPS-0509-176 (Coarse PM) |
| Safety Certification | CE / EN 61326 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PDD Detector |
| Instrument Type | Universal Selective Detector for GC |
| Operating Temperature Range | Up to 400 °C |
| Linear Dynamic Range | 10⁵ |
| Method Detection Limit (MDL) | Low-picogram level |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PDM3600 |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™) |
| Safety Rating | Non-explosion-proof |
| Measurement Range | 0–200 mg/m³ |
| Resolution | 0.05 mg/m³ (1σ, 30-sec average) |
| Accuracy | ±25% of reference method (for concentrations >0.2 mg/m³) |
| Relative Humidity Range | 0–100% RH |
| Operating Temperature | −20°C to +40°C |
| Mass Sensor Temperature Range | 0°C to +60°C |
| Sampling Flow Rate | 2.2 L/min (±2% σ in lab |
| Minimum Detectable Load | 0.1 mg |
| Maximum Load Capacity | 4 mg |
| Dimensions (Monitor Housing) | 24.31 cm W × 8.26 cm D (excl. clip) / 8.69 cm D (incl. clip) × 17.15 cm H (excl. PTO) / 19.30 cm H (incl. PTO) |
| Weight (Monitor) | 2.27 kg |
| Umbilical Cable | 167 cm long, 0.51 kg |
| TEOM Sensor Module | 5.82 cm W × 4.9 cm D × 7.75 cm H |
| Charging Module | 7.21 cm W × 15.25 cm D × 19.38 cm H, 1.42 kg |
| Power Supply | Dual internal lithium-ion battery packs |
| Compliance | MSHA Approval No. 19-A040002-0 |
| EN 61326-1 | 2005 |
| Charger | ANSI/UL 1012, Class 2, 7th Ed. (Apr 29, 2005) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | PDM 3700 |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™) |
| Safety Rating | Intrinsically Safe (MSHA/NIOSH Certified) |
| Measurement Range | 0–200 mg/m³ |
| Resolution | ±25% of reference method (for concentrations >0.2 mg/m³) |
| Accuracy | ±2% (2σ, laboratory), ±5% (2σ, underground coal mine) |
| Relative Error | ±25% of reference method (for concentrations >0.2 mg/m³) |
| Sampling Flow Rate | 2.2 L/min (±2% at lab, ±5% in mine) |
| Mass Sensitivity | 0.05 mg/m³ (1σ, 30-sec average) |
| Operating Temperature | −20 °C to +40 °C |
| Sensor Temperature Range | 0 °C to +60 °C |
| Relative Humidity | 0–100% RH (non-condensing) |
| Minimum Detectable Load | 0.1 mg |
| Maximum Load Capacity | 4 mg |
| Power Supply | Rechargeable Li-ion battery pack |
| Compliance | NIOSH TC-74CPDM-02, MSHA 18-A140015-0, PA BFE 2-15, 30 CFR Part 74, EN 61326-1:2005, FCC Part 15 Subpart B, UN 3480 (Li-ion transport) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | pDR-1500 |
| Measurement Principle | Optical Light Scattering (880 nm IR) with Gravimetric Calibration Capability |
| Measured Parameters | PM₁₀, PM₂.₅ (with optional cyclone cutters) |
| Measurement Range | 0.001–400 mg/m³ (auto-ranging) |
| Sampling Flow Rate | 1.0–3.5 L/min |
| Minimum Detectable Concentration | 0.1% of reading or 0.001 mg/m³ (whichever is greater) |
| Flow Stability | ±5% of reading (traceable to SAE test protocols) |
| Resolution | 0.1% of reading or 0.001 mg/m³ (whichever is greater) |
| Accuracy | ±5% of reading (traceable to SAE standards) |
| Precision | ±2% of reading or ±0.005 mg/m³ (1-s avg) |
| Scattering Coefficient Range | ~1.5×10⁻⁶–0.6 m⁻¹ @ λ = 880 nm |
| Aerodynamic Particle Size Range | 1–10 µm |
| Optical Detection Angle | 90° |
| RH Compensation | Built-in relative humidity correction algorithm |
| Operating Temperature | –10°C to +50°C |
| Storage Temperature | –20°C to +70°C |
| Humidity Range | 10–95% RH (non-condensing) |
| Data Logging Interval | 1 s to 1 h |
| Total Memory Capacity | >500,000 data points |
| Power Supply | Internal rechargeable Li-ion battery (≥12 h field operation) + external DC input |
| Connectivity | Wi-Fi 802.11 b/g/n, iOS/Android mobile app support |
| Physical Dimensions | 181 mm (H) × 143 mm (W) × 84 mm (D) |
| Weight | 1.2 kg |
| Filter Medium | 37 mm glass fiber filter (for gravimetric validation) |
| Flow Control | Active volumetric flow control with linear flow path design |
| Inlet Configuration | Helical inlet for representative sampling without cyclone |
| Zero Calibration | Integrated HEPA-filtered zero air source |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | pDR/ADR-1500 |
| Measurement Principle | Nephelometric Light Scattering (880 nm LED) |
| Measured Parameter | PM₂.₅ (also configurable for PM₁, PM₄, PM₁₀ via interchangeable cyclones) |
| Flow Control | True Volumetric Flow Control with Digital Pressure Feedback |
| Humidity Compensation | Integrated Heated RH Sensor & Algorithmic Correction |
| Compliance | NIOSH Methods 0500 & 0600, ACGIH-Traceable Cyclones |
| Data Storage | >500,000 records |
| Display | Dual-line LCD (16×2 characters) |
| Dimensions (pDR-1500) | 181 × 143 × 84 mm |
| Dimensions (ADR-1500) | 533 × 431 × 215 mm |
| Weight (ADR-1500) | 12.9 kg |
| IP Rating | IP65 (ADR-1500) |
| Power Options | AC, DC, or Internal Rechargeable Battery |
| Communication Interfaces | USB, RS-232, 0–2 V / 4–20 mA Analog Outputs, Optional Wireless Module |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | Forma FDE50086FV / Revco RDE50086FV / Thermo Scientific TDE50086FV |
| Net Capacity | 682 L |
| Internal Dimensions (W×D×H) | 719 × 730 × 1301 mm |
| External Dimensions (W×D×H) | 977 × 864 × 1981 mm |
| Power Supply | 220 V, 50 Hz |
| Rated Power Consumption | 400 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Models | FDE60086FV, RDE60086FV, TDE60086FV |
| Net Capacity | 816 L |
| Internal Dimensions (W×D×H) | 719 × 873 × 1301 mm |
| External Dimensions (W×D×H) | 977 × 1006 × 1981 mm |
| Power Supply | 220 V / 50 Hz |
| Rated Power Consumption | 400 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PM CEMS |
| Measurement Principle | Dual-Method (Beta Attenuation + Tapered Element Oscillating Microbalance, TEOM™) |
| Measured Parameter | Particulate Matter Mass Concentration (PM₁₀, PM₂.₅, or Total Suspended Particulates) |
| Range | 0–250 mg/m³ |
| Accuracy | ±20% (uncorrected), ±10% (source-corrected) |
| Detection Limit | 0.25 mg/m³ (15-min integration) |
| Response Time (T₉₀) | 15 min |
| Operating Flue Gas Temperature | ≤200 °C |
| Ambient Operating Temperature (Controller) | 4–50 °C |
| Power Supply | 200–240 VAC, 50/60 Hz, 30 A |
| Instrument Air | 80 slpm at 0.55–0.7 MPa (75–100 psi) |
| Probe Dimensions | 1117.85 mm W × 914/1524 mm L (sheath length options) × 474.73 mm H × 307.09 mm D |
| Probe Weight | 59 kg (130 lbs) |
| Controller Dimensions | 482.6 mm W × 218.95 mm H × 655.32 mm D |
| Controller Weight | 25 kg (55 lbs) |
| Analog Outputs | 6 voltage (0–100 mV, 1/5/10 V), 6 current (0–20 mA, 4–20 mA) |
| Digital/Relay Outputs | 1 power-fail alarm, 10 configurable relay outputs |
| Compliance | EPA PS-11, QA Procedure 2, Method 5/17 verified |
| Calibration Traceability | NIST-traceable mass reference |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Models | 6051, 6053, 6054, 6055 |
| Temperature Range | 15°C to 325°C |
| Temperature Uniformity | ±0.5°C |
| External Dimensions | 71.1 × 114.3 × 73.7 cm |
| Internal Chamber Dimensions | 48.3 × 48.3 × 48.3 cm |
| Chamber Material | Stainless Steel (304) |
| Heating Method | Forced-Air Convection with Turbo Blower |
| Temperature Sensor | High-Sensitivity RTD (±0.1°C accuracy) |
| Control System | Microprocessor-Based PID Controller with LED Display |
| Timer | Mechanical 12-Hour Timer |
| Safety Features | Adjustable Over-Temperature Cut-Off, Built-in Circuit Breaker, Fiberglass Door Gasket, Low-Density Heating Elements |
| Shelf Spacing | 4 cm (1.6″), Non-Sharp Nickel-Plated Shelves (2 included) |
| Optional Configurations | Model 605P (Low-Flow Baffle Kit), Model 625S (Rear Pressure Relief Panel, Snap-Latch Front Door) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Models | SWB27 / SWB15 / SWB15S / DUB15 |
| Instrument Category | Water Bath / Oil Bath Constant-Temperature Tank |
| Circulation | Internal Recirculation |
| Temperature Control | Heating-Only |
| Bath Capacity | 15 L / 27 L |
| Temperature Range | +5 °C to 100 °C |
| Temperature Stability | ±0.1 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Circulating Water/Oil Bath |
| Models | GP02, GP2S, GP05, GP10, GP20, GP28, GP15D |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Bath Capacity | 2 L, 5 L, 10 L, 20 L, 28 L (dual-chamber option: 5 L + 10 L) |
| Circulation | Internal & External |
| Construction | Seamless Stainless Steel Interior, Epoxy-Powder-Coated Exterior |
| Safety Features | Over-Temperature Cut-Off, Low-Level Fluid Protection, Auto-On/Auto-Off Timer, Audible Alarm |
| Control Interface | Icon-Based Graphical Display with Four User-Programmable Temperature Presets |
| Drain Valve | Quick-Release for 10 L, 20 L, 28 L and Dual-Chamber Units |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Thermo Scientific Prima BT |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Thermo Scientific Prima BT |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Prima PRO |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Electron Gun Type | Cold Field Emission |
| Model | Prisma E SEM |
| Vacuum Modes | High Vacuum, Low Vacuum, Environmental SEM (ESEM) Mode |
| Sample Chamber Capacity | Up to 18 samples per load |
| Detector Flexibility | Multiple detector options including SE, BSE, EDS, and optional STEM-in-SEM |
| Software Integration | ColorSEM real-time elemental mapping, image navigation, customizable UI with Undo/Redo functionality |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Q Exactive Focus LC-MS/MS |
| Price Range | USD 260,000 – 390,000 (based on configuration and regional duties) |
| Instrument Type | Hybrid Quadrupole-Orbitrap Mass Spectrometer |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Q Exactive™ GC Orbitrap |
| Instrument Category | Orbitrap-based GC-MS/MS System |
| Chromatography Type | Conventional Gas Chromatography Coupled Mass Spectrometry |
| Mass Range | Not Specified |
| Resolution | Up to 100,000 (FWHM) at m/z 272 |
| Mass Accuracy | < 1 ppm (typical, internal calibration) |
| Sensitivity | < 6 fg OFN (octafluoronaphthalene) LOD under EI mode |
| Scan Speed | Not Specified |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Q Exactive HF LC-MS System |
| Instrument Type | Orbitrap-based Hybrid Quadrupole-Orbitrap Mass Spectrometer |
| Scan Speed | Up to 12 Hz MS/MS in 1 s |
| Resolution (at m/z 200) | 240,000 FWHM (standard mode), up to 500,000 FWHM (enhanced mode) |
| Mass Accuracy | < 1 ppm RMS (internal calibration), < 3 ppm RMS (external calibration) |
| Mass Range | m/z 50–6,000 |