Chemical Analysis Instruments
Filter
Showing 3271–3300 of 10730 results
| Brand | GKinst |
|---|---|
| Model | GK-TB01 |
| Construction Material | Stainless Steel |
| Coating Width Range | 15–25 mm (Default: 25 mm) |
| Doctor Blade Gap (Shim Thickness) | 100 µm |
| Stage Temperature Range | Up to 100 °C |
| Maximum Translation Stroke | 100 mm |
| Stage Velocity Range | 100 µm/s – 50 mm/s |
| Stage Flatness | <20 µm |
| Stage Surface Roughness | 3 µm |
| Maximum Substrate Thickness | 20 mm |
| Pump Integration | High-Precision Syringe Pump Compatible |
| Application Scope | R&D, Process Optimization, Ink Formulation, Small-Batch Film Fabrication |
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HPXRD |
| Configuration | Floor-Standing |
| X-ray Source | Liquid-Metal In Target (E1 Type) |
| High-Flux Mode | 90 μm focal spot, 1.9 × 10⁸ ph/s, divergence 3.15 mrad |
| Micro-Focus Mode | 15 μm focal spot, 1.8 × 10⁷ ph/s, divergence 12.6 mrad |
| Ultra-Micro Mode | 10 μm focal spot, 1.0 × 10⁶ ph/s, divergence 2 mrad |
| XY Stage Repeatability | ±0.2 μm, travel ±10 mm |
| Z Stage Repeatability | ±0.2 μm, travel ±10 mm |
| φ Axis Repeatability | 0.002°, travel ±135° |
| X₁Y₁ Stage Repeatability | ±0.2 μm, travel ±12.5 mm |
| Brand | GKInst |
|---|---|
| Model | LaScater 1.0 |
| Origin | Anhui, China |
| Instrument Type | Integrated SAS System |
| Laser Wavelength Range | 390–780 nm |
| Laser Power | 1–100 W (continuously adjustable) |
| Power Stability | < 1% RMS |
| Beam Divergence | < 0.015° |
| Sample Stage Travel (X/Y) | ±75 mm |
| Z-Travel | ±10 mm |
| Positioning Accuracy | 1 µm |
| Angular Axes (β/γ) | ±7.5°, Resolution: 0.001° |
| Rotational Axis (α) | 360°, Resolution: 0.001° |
| Detector | CCD/CMOS hybrid sensor |
| Pixel Size | 10 µm × 10 µm |
| SNR | >40 dB |
| Peak Quantum Efficiency | 0.65 A/W |
| Frame Rate (high-speed mode) | up to 60 fps |
| Cooling | Peltier-based thermoelectric cooling for low-noise acquisition |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LFocus |
| Pricing | Available Upon Request |
| Target Applications | XRD, XRF |
| Anode Materials | Mo, Cu, W, Ag, Cr, Co, Fe, Ti |
| Tube Voltage Range | 20–60 kV |
| Tube Current Range | 5–40 mA |
| Max Power Output | 0.4–3.0 kW (material-dependent) |
| Beam Geometry | Linear focal spot (line focus) |
| Protection Features | Overvoltage, Overcurrent, Overpower shutdown |
| Thermal Management | Adaptive preheat algorithm based on idle time |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MFocus |
| Pricing | Available Upon Request |
| Maximum Tube Voltage | 50–65 kV |
| Maximum Power | 30–200 W |
| Focal Spot Size | 10–70 µm |
| Beam Divergence Angle | 10°–18° |
| Anode Target Materials | Cu, Mo, Ag, W |
| Integrated Features | Active Liquid Cooling System, Motorized X-ray Shutter, Dual-Color (Red/Green) Status Indicator, Hardware Safety Interlock Circuit |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | SAXSFocus |
| Price Range | USD 420,000 – 1,120,000 |
| Instrument Type | Small-Angle X-ray Scattering (SAXS) System |
| Measurement Dynamic Range | 32-bit, 1 × 10⁷ photons/s/pixel |
| Brand | GKinst |
|---|---|
| Model | GK-THMS600V |
| Temperature Range | −195 °C to +600 °C |
| Max. Heating Rate | 180 °C/min (customizable) |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | <0.1 °C |
| Compatibility | Optical Microscopes, Raman Spectrometers, FTIR Microscopy Systems, UV-Vis Microspectrophotometers |
| Brand | GKinst |
|---|---|
| Model | GK-TST350V |
| Force Range | 0–500 N / 0–200 N / 0–20 N |
| Force Resolution | 0.01 N |
| Max. Extension | 80 mm |
| Displacement Resolution | 0.01 mm |
| Displacement Speed | 1–1000 µm/s |
| Force Control Modes | Constant Velocity, Constant Force, Position Hold, Jog, Cyclic Loading |
| Vacuum Compatibility | Customizable for Ultra-High Vacuum (≤1×10⁻⁵ Pa) |
| Temperature Range | –195 °C to +350 °C |
| Origin | Anhui, China |
| Brand | GKINST |
|---|---|
| Model | Customizable DAC Gas Loading System |
| Max Operating Pressure | 200 MPa |
| Compatible Gases | He, Ne, Ar, N₂, CH₄, H₂ (O₂ excluded) |
| DAC Compatibility | Modular Design for Standard & Custom DACs |
| Origin | Anhui, China |
| Supplier Type | Authorized Distributor |
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | X-Ray Reflective Mirror |
| Pricing | Available Upon Request |
| Focal Length | 110 mm |
| Optimized Energies | 8.0 keV (Cu Kα), 17.24 keV (Mo Kα) |
| Output Beam Divergence | ΔΦ ≤ 0.4 mrad |
| Reflectivity | ≥ 65% (integrated, at optimized energy) |
| Dimensions (L × W × H) | 100 mm × 40 mm × 30 mm (custom sizes available) |
| Brand | GKINST |
|---|---|
| Model | XMS-P15-AP-Ta5 |
| Aperture Diameter | 10 mm |
| X-ray Energy Range | 12–30 keV |
| Operating Temperature | 10–50 °C |
| Control Interface | 6-pin aviation connector |
| Drive Voltage/Current | ≤30 V, ≤2 A |
| Supply Voltage | 18 VDC |
| Dimensions (L×W×H) | 200 × 70 × 34 mm |
| Weight | 0.6 kg |
| Brand | GAOMAI |
|---|---|
| Origin | Beijing, China |
| Model | GM Explosion-Proof Analytical Shelter |
| Instrument Type | Portable Gas Chromatograph System Enclosure |
| Application Scope | General-purpose Industrial Process Gas Analysis |
| Explosion Protection Rating | Exd II BT1 to Exd II CT6 (customizable per user specification) |
| Ambient Temperature Control Capability | Integrated HVAC with temperature stabilization |
| Humidity & Dust Protection | IP56-rated enclosure |
| Internal Overpressure Maintenance | 30–100 Pa (gauge) |
| Alarm Function | Audible and visual alarm triggered by hazardous gas concentration exceedance |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Compliance | Designed to meet IEC 60079-1, GB 3836.1–2021, and ISO 8573-1 for compressed air quality in analytical service lines |
| Structural Certification | Fabricated per ASME BPVC Section VIII Div. 1 (optional) |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | APD 2000 PRO |
| Instrument Type | Powder X-ray Diffractometer |
| X-ray Tube Power | 0.0001 kW (100 W) |
| Radiation Source | Fine-focus Ceramic X-ray Tube |
| Monochromator | Johannson-type Kα₁ monochromator |
| Detector Types | Scintillation Counter & Energy-Dispersive Detector |
| Goniometer Control | Optical Encoder |
| Sample Stage | Motorized Multi-Sample Rotating Stage with Low-Background Options |
| Safety System | Dual Redundant Interlock Circuit |
| Compliance | CE, IEC 61010-1, ISO 9001 |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | AreX D |
| X-ray Source | 50 W Mo microfocus tube with Zr filter |
| Cooling | Air-cooled |
| Detection | High-resolution USB camera for precise sample positioning |
| Safety | Interlocked X-ray shielding system |
| Measurable Diffraction Peaks | Austenite (220), (311) |
| Measurement Time | < 3 minutes per sample |
| Compliance | ASTM E975-22 Standard |
| Minimum Detectable Austenite Content | 0.5 vol% |
| Sample Compatibility | Flat, polished metallic specimens (steel, stainless steel, tool steels, bearing alloys) |
| Software | Integrated Windows-based analysis suite with peak integration, phase quantification, and report generation |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | AREX L |
| Compliance | ASTM E975 |
| Measurement Principle | X-ray Diffraction (XRD) |
| Detection Limit | ≤0.5% austenite |
| Target Material | Ferrous alloys (steel, cast iron, heat-treated components) |
| X-ray Source | High-power ceramic X-ray tube |
| Optics | High-focus single-capillary collimator |
| Detector | High-resolution CCD detector |
| Stability Control | Precision closed-loop feedback circuit for HV/current regulation |
| Data Acquisition | Multi-peak intensity ratio analysis (austenite {220}, {311} / ferrite {200}, {211}) |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | EDGE |
| Compliance | ASTM E915, EN 15305 |
| Detector | Linear silicon strip detector with single-photon counting technology |
| Cooling | Air-cooled |
| X-ray Source | Interchangeable microfocus X-ray tubes |
| Fluorescence Suppression | Integrated X-ray fluorescence rejection |
| Measurement Time | Minutes per point (vs. hours for conventional systems) |
| Portability | Fully integrated into carry-on compliant transport case |
| Safety Options | Optional radiation shielding enclosure for benchtop operation |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | EXPLORER |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 0.0001 kW |
| Optical Configuration | Switchable Bragg-Brentano focusing / Johansson monochromator / Parabolic mirror monochromator |
| Beam Geometry | Parallel-beam optics with low-angle reflection capability |
| Thin-film Thickness Detection Range | 1–500 nm |
| Degrees of Freedom for Sample Manipulation | 5 |
| Modular Units | 7 |
| Primary Applications | Phase identification & quantification, crystallite size and microstrain analysis, residual stress measurement, texture analysis, thin-film characterization, depth profiling, nanocrystalline material assessment |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | HORIZON |
| Configuration | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | Na (11) to Pu (94) |
| Quantification Range | 10 pg – 100% |
| Energy Resolution | 124 eV (at Mn Kα) |
| Repeatability | ≤ 0.1% RSD |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | MagStress5c |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) |
| Sample Type | Ferromagnetic Metals (e.g., carbon steel, alloy steel, cast iron) |
| Portability | Integrated battery-powered handheld system with touch-screen interface and USB connectivity |
| Output | Quantitative residual stress in MPa, graphical trend visualization, calibration curve support |
| Compliance Context | Designed for field-deployable non-destructive evaluation (NDE) in accordance with ASTM E1447, ISO 20956, and EN 10328 guidelines for magnetic methods of stress assessment |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | S5 |
| Instrument Type | Floor-Standing |
| Excitation Method | Spark |
| Focal Length | 500 mm |
| Groove Density | 3600 lines/mm |
| Wavelength Range | 130–900 nm |
| Detection Mode | Full-Spectrum CCD |
| Vacuum Optical Chamber | Integrated, Sealed |
| Elemental Coverage | C, P, S, N, Al, Ni, Cr, Mn, Cu, Mo, V, Ti, Co, Nb, W, Sn, Pb, Zn, Mg, Ca, Si, Fe, As, Bi, Sb, etc. |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | STRESS-X |
| Compliance | ASTM E915, EN 15305 |
| Motion System | 6-axis robotic arm |
| Deployment Options | Benchtop shielded enclosure or mobile four-wheel alloy cart |
| Measurement Principle | Sin²ψ X-ray diffraction (XRD) |
| Application Scope | Non-destructive residual stress mapping on metallic components |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | TX 2000 |
| Configuration | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | Na (11) to Pu (94) |
| Quantification Range | 10 pg – 100% |
| Energy Resolution | 124 eV (at Mn Kα) |
| Repeatability | 0.1% RSD |
| Detector | Peltier-cooled Silicon Drift Detector (SDD) |
| Excitation Source | Switchable Mo/W anode X-ray tube |
| Angular Control | High-precision optical encoder stepper motor |
| Brand | Golden Promise |
|---|---|
| Model | AHS-6890 |
| Type | Semi-Automatic Headspace Sampler |
| Sample Capacity | 12-position vial carousel |
| Vial Size | Standard 20 mL (customizable: 5 mL, 10 mL, 50 mL) |
| Sample Zone Temp Range | Ambient to 200 °C (1 °C increments) |
| Transfer Line Temp Range | Ambient to 160 °C (1 °C increments) |
| Valve & Loop Temp Range | Ambient to 160 °C (1 °C increments) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Uniformity | ±0.5 °C |
| Pressurization Range | 0–0.4 MPa (continuously adjustable) |
| Carryover Reduction | Programmable purge flow and duration |
| Reproducibility | RSD < 3% (dependent on GC system performance and operator technique) |
| Dimensions (W×D×H) | 200 × 380 × 400 mm |
| Weight | ~20 kg |
| Control Interface | Microprocessor-based with LCD display, membrane keypad, and embedded time-programmable logic (8-step sequence, 9 stored methods) |
| GC Synchronization | TTL-compatible event triggering |
| Safety | Low-voltage heating circuitry for transfer lines |
| [Brand | Golden Promise |
|---|---|
| Origin | Shandong, China |
| Model | GC-2011 |
| Detection Principles | Dual-channel gas chromatography with simultaneous TCD and FID detection |
| Temperature Control | 8°C above ambient to 420°C (±0.1°C ≤200°C |
| Programmed Temperature Ramping | 8-step linear ramping, 0.1–30°C/min (0.1°C increment) |
| Detector Sensitivity | FID: ≤1×10⁻¹¹ g/s (benzene) |
| TCD | ≥3500 mV·mL/mg (benzene) |
| Column Compatibility | Dual-inlet system — packed column inlet (TCD-optimized) + dedicated split/splitless capillary inlet with tail-purge |
| Dimensions | 540 × 455 × 465 mm |
| Weight | 50 kg |
| Power | AC 220 V ±10%, 50 Hz, ~2 kW] |
| [Brand | Golden Promise |
|---|---|
| Origin | Shandong, China |
| Model | GC-7890 |
| Instrument Type | Online Gas Chromatograph |
| Application Field | General-Purpose Industrial Process Analysis |
| Temperature Control Range | 5 °C to 450 °C |
| Oven Temperature Stability | ±0.1 °C (≤200 °C), ±0.2 °C (>200 °C) |
| Ramp Rate | 1–30 °C/min |
| Cooling Rate | Variable, enabled by intelligent back-door temperature modulation |
| Carrier Gas Flow Control | Digital mass flow control (MFC) compatible with He, H₂, N₂ |
| Carrier Gas Pressure Control | Electronic pressure control (EPC) with 0–1000 kPa range |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Total Injector Flow Setting Range | 0–200 mL/min |
| Detectors | FID (MDL ≤1×10⁻¹¹ g/s benzene), TCD (Sensitivity ≥3000 mV·mL/mg benzene), optional ECD/FPD/NPD support |
| Column Compatibility | Dual packed-column inlets + dedicated split/splitless capillary inlet with makeup gas and tail-purge capability |
| Thermal Programming | 5-step programmable ramping |
| Safety Features | Power-fail memory, overtemperature cutoff, carrier gas failure protection, real-time fault diagnostics] |
| Brand | Golden Promise |
|---|---|
| Model | GC-8890 |
| Type | Online Gas Chromatograph |
| Origin | Shandong, China |
| Instrument Category | Domestic |
| Control Architecture | Full EPC/EFC (Optional) |
| Temperature Programming | 0.1–80 °C/min |
| Column Oven Cooling | 350 °C → ambient in ≤3 min |
| Detection Compatibility | Simultaneous FID & TCD operation |
| Injector Precision | RSD ≤2% (n=6) |
| Flow Control Resolution | 0.01 sccm / 0.01 kPa |
| Temperature Stability | ±0.1 °C |
| External Event Channels | 8 |
| Auto-Ignition | Hydrogen/Air intelligent sequencing with flame-out detection |
| Dual Back-Door Mechanism | Motorized, temperature-responsive actuation |
| Safety Protections | Overtemperature cutoff, TCD filament safeguard, gas-loss alarm, power-fail retention, short/open circuit diagnostics |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Brand | Golden Promise |
|---|---|
| Model | GC-8890SD |
| Origin | Shandong, China |
| Weight | 60 kg |
| Dimensions (L×W×H) | 565 × 505 × 500 mm |
| Detection Limit | ≤1×10⁻¹² g/s (n-C₁₆, FID) |
| Connectivity | 10/100M Ethernet (IEEE 802.3) |
| Column Oven Temp Range | 5–400 °C (0.1 °C increment, ±0.1 °C stability) |
| Max Heating Rate | 40 °C/min (programmable up to 20 steps) |
| Cooling Rate | ≤3 min (200 → 100 °C) |
| Detector Options | FID, TCD (configurable) |
| Power Supply | 220 V ±10%, 50 Hz ±0.5 Hz, 2500 W max |
| [Brand | Golden Promise |
|---|---|
| Model | LC-3000 |
| Pump Type | Dual-plunger reciprocating high-pressure gradient system |
| Max Pressure | 42 MPa (P3110), 30 MPa (P3120) |
| Flow Range | 0.002–9.998 mL/min (P3110), 0.01–49.99 mL/min (P3120) |
| Flow Accuracy | ±2% (2–5% of set flow, MeOH/H₂O 80:20) |
| Flow RSD | <0.1% |
| Detector | UV/VIS (UV3000) |
| Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Scan Modes | Programmable stop-flow scanning (start/end/step configurable) |
| Absorbance Range | 0–2 AU |
| Baseline Noise | 2×10⁻⁵ AU/h (1 mL/min, MeOH/H₂O 80:20, 254 nm) |
| Baseline Drift | 15×10⁻⁵ AU/h (1 mL/min, MeOH/H₂O 80:20, 254 nm) |
| Time Constants | 0.1/0.2/0.5/1/2/5/10 s |
| Lamp Options | Deuterium (standard), Tungsten (optional) |
| Display | 320×240 dot-matrix LCD with adjustable blue backlight |
| Communication | RS-232 interface |
| Power | 220 V ±10%, 50 Hz (pump: 400 W |
| detector | 60 W) |
| Dimensions (D×H×W) | 398×149×267 mm |
| Weight | 14 kg |
| GLP Features | Lamp operating time logging, lamp cycle count, lamp replacement history, serial number traceability] |
| [Brand | Golden Promise |
|---|---|
| Model | LC-3000 |
| Type | HPLC-Based Melamine Quantification System |
| Origin | Shandong, China |
| Instrument Class | Benchtop Liquid Chromatograph for Targeted Small-Molecule Analysis |
| Detection Principle | UV-Vis Absorption at 240 nm with Diode Array or Fixed-Wavelength UV Detector |
| Column Compatibility | Reversed-Phase C8/C18 (e.g., 250 mm × 4.6 mm, 5 µm) |
| Flow Rate Range | 0.1–2.0 mL/min |
| Column Oven Temperature Control | Ambient to 60 °C |
| Sample Injection Volume | 5–100 µL (manual or optional autosampler-ready) |
| Regulatory Alignment | Designed for ASTM D7968-19, ISO 17394:2015, and GB/T 22388–2008 compliant workflows |
| Software | PC-based chromatography data system (CDS) with peak integration, calibration curve generation (linear/non-linear), audit trail, and report export (PDF/CSV)] |
| Brand | Golden Promise |
|---|---|
| Model | OG-2000V |
| Origin | Shandong, China |
| Instrument Type | Rock Pyrolysis Analyzer for Geochemical Evaluation of Source Rocks |
| Compliance | Designed for ASTM D5307 / ISO 10374 / SY/T 5115-2014 |
| Detection Principle | Controlled-Temperature Pyrolysis coupled with Flame Ionization Detection (FID) and Thermal Conductivity Detection (TCD) |
| Sample Form | Crushed core or cuttings (dry, <1 mm particle size) |
| Temperature Range | Ambient to 650 °C (programmable ramp rates) |
| Data Interface | USB 2.0 (Windows-compatible, driver-free operation) |
| Measurement Output | S1 (free hydrocarbons), S2 (kerogen-derived hydrocarbons), S3 (CO₂ from organic carbon), Tmax (peak pyrolysis temperature), HI/OI (Hydrogen Index / Oxygen Index) |
| Accuracy | ±2% FS for S1/S2 |
| Power Supply | 220 VAC, 50 Hz, 1.5 kW |