Chemical Analysis Instruments
Filter
Showing 4591–4620 of 10742 results
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | FLA2000 |
| Spectral Range | 200–1100 nm |
| Detector | Hamamatsu CMOS Linear Array (2048 pixels) |
| Optical Resolution | 1.0 nm FWHM |
| Slit Width | 70 µm (standard, customizable) |
| Signal-to-Noise Ratio | 750:1 |
| Dynamic Range | 500,000 |
| Stray Light | < 0.1% |
| Linearity | > 99.8% |
| Sensitivity | 1300 V/(lx·s) |
| Interface | USB 2.0, RS-232, RS-485 |
| Dimensions | 80 × 63 × 34 mm |
| Weight | 320 g |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | FLA3000 |
| Spectral Range | 200–1100 nm |
| Detector | Hamamatsu CMOS Linear Array |
| Optical Resolution (FWHM) | 0.8 nm |
| Sensitivity | 2600 V/(lx·s) |
| Signal-to-Noise Ratio | 500:1 |
| Dynamic Range | 150,000 |
| Stray Light | <0.1% |
| Pixel Count | 1024 |
| Slit Width | 70 µm (standard, optional) |
| Linearity | >99.8% |
| Interface | USB 2.0, RS-232, RS-485 |
| Dimensions | 128 × 72 × 40 mm |
| Weight | 500 g |
| Spectral Range | 200–1100 nm |
|---|---|
| Detector | Hamamatsu CMOS Linear Array (1024 pixels) |
| Optical Resolution (FWHM) | 0.32–0.8 nm (configurable via grating & slit) |
| Slit | Standard 70 µm (optional) |
| Signal-to-Noise Ratio | 380:1 (typ.), up to 500:1 (peak) |
| Dynamic Range | 1.6 × 10⁶ |
| Stray Light | < 0.1% |
| Integration Time | 1 ms – 65 s |
| A/D Converter | 16-bit with auto-zero dark correction |
| FIFO Depth | 4K samples |
| Interface | USB 2.0 (standard), RS232, RS485 |
| Dimensions | 128 × 72 × 40 mm |
| Weight | 500 g |
| Calibration Storage | Onboard EEPROM |
| Linearity | >99.8% |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | FLA4000 (Flash-Triggered) |
| Spectral Range | 200–1100 nm |
| Detector | CMOS |
| Optical Resolution (FWHM) | 0.8 nm |
| Sensitivity | 1300 V/(lx·s) |
| Signal-to-Noise Ratio | 380:1 |
| Dynamic Range | 1,600,000 |
| Stray Light | <0.1% |
| Spectral Range | 350–1100 nm |
|---|---|
| Detector | Hamamatsu CMOS linear array (2048 pixels) |
| Optical Resolution (FWHM) | ≤1.20 nm |
| Stray Light | <0.1% |
| Signal-to-Noise Ratio | 380:1 |
| Dynamic Range | 250,000 |
| Sensitivity | 1300 V/(lx·s) |
| A/D Conversion | 16-bit with auto-zero dark correction |
| Data Buffer | 4K-depth FIFO |
| Interface | USB 2.0, RS232, RS485 |
| Slit Width | 70 µm (standard, optional) |
| Linearity | >99.8% |
| Dimensions | 128 × 72 × 40 mm |
| Weight | 500 g |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Spectral Range | 200–1100 nm |
| Detector | Hamamatsu CMOS Linear Array |
| Resolution | 0.10 nm FWHM |
| Sensitivity | 1300 V/(lx·s) |
| Signal-to-Noise Ratio | 1000:1 |
| Dynamic Range | 1,000,000 |
| Stray Light | < 0.1% |
| Pixel Count | 2048 |
| Slit Width | 30 µm (standard, optional) |
| Linearity | >99.8% |
| Interface | USB 2.0, RS-232, RS-485 |
| Dimensions | 157 × 110 × 50 mm |
| Weight | 1150 g |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Model | FLA6300 |
| Spectral Range | 200–1100 nm |
| Detector | Back-Illuminated CCD Linear Array |
| Optical Resolution | ≤0.1 nm FWHM (at specified slit and grating configuration) |
| Sensitivity | 7 µV/e⁻ |
| Signal-to-Noise Ratio | 600:1 (full well, single acquisition) |
| Dynamic Range | 90,000:1 |
| Stray Light | <0.1% |
| Pixel Count | 2048 pixels |
| Standard Slit Width | 70 µm (optional) |
| Linearity | >99.8% |
| Interface | USB 2.0 |
| Dimensions | 182 × 110 × 50 mm |
| Weight | 1600 g |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | FLA6500 |
| Spectral Range | 200–1100 nm |
| Detector Type | Hamamatsu CCD Array |
| Optical Resolution | 0.50 nm FWHM |
| Sensitivity | 2.2 µV/e⁻ |
| Signal-to-Noise Ratio | 1000:1 |
| Dynamic Range | 2×10⁶ |
| Stray Light | <0.1% |
| Pixel Count | 1024 pixels |
| Slit Width | 70 µm (standard, optional) |
| Linearity | >99.8% |
| Minimum Integration Time | 3.6 ms |
| ADC | 16-bit with auto-zero dark current correction |
| FIFO Depth | 4K |
| Interface | USB 2.0 |
| Dimensions | 182 × 110 × 50 mm |
| Weight | 1600 g |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop Laboratory Spectrometer |
| Optical Principle | Fixed Grating with Linear InGaAs Array Detector (Non-scanning) |
| Wavelength Range | 1000–1700 nm |
| Measurement Modes | Transmission, Reflection, Absorbance |
| Chemometrics Software | FLA Suite |
| Detector | InGaAs (256-pixel linear array) |
| Pixel Resolution | 256 pixels |
| Slit Width | 200 µm (standard, optional) |
| Optical Resolution (FWHM) | ≤3.2 nm |
| Stray Light | <0.1% |
| SNR | 1200:1 (full signal, 1 s integration) |
| Linearity | >99.8% |
| Dynamic Range | 900,000 (typical, 16-bit digitization) |
| A/D Converter | 16-bit high-speed |
| FIFO Buffer | 4 KB |
| Interface | USB 2.0 |
| Dimensions | 182 × 110 × 50 mm |
| Weight | 1500 g |
| Power Supply | Bus-powered via USB 2.0 (no external power required) |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory-grade |
| Model | FLA6800 |
| Spectral Range | 1000–2500 nm |
| Optical Resolution | ≤3.20 nm (FWHM) |
| Stray Light | <0.1% |
| Detector | InGaAs linear array (512 pixels) |
| Slit Width | 200 µm (standard, optional) |
| SNR | 1200:1 |
| Linearity | >99.8% |
| Dynamic Range | 900,000 |
| Data Acquisition Interval | 12 ms + integration time |
| Sampling Mode | Reflectance / Transmittance |
| A/D Converter | 16-bit |
| FIFO Depth | 4K |
| Interface | USB 2.0 |
| Dimensions | 182 × 110 × 50 mm |
| Weight | 1500 g |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | FLB1001 |
| Interface | SMA905 / 3/8"-24 UNF |
| Lens Material | UV-Fused Silica |
| Focal Length | 10 mm |
| Output Beam Diameter | Ø5 mm |
| Spectral Range | 200–1100 nm |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | FLB1004 |
| Coating Material | Barium Sulfate (BaSO₄) or Polytetrafluoroethylene (PTFE) |
| Diameter | 30 mm |
| Spectral Range | 380–780 nm |
| BaSO₄ Reflectance | >98% (380–780 nm), ≥88% (UV–NIR extended range) |
| PTFE Reflectance | >93% (380–780 nm), ~90% (extended range) |
| Compliance | ASTM E259, ISO 2813, USP <857> |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | FLB1007 |
| Pricing | Available Upon Request |
| Interface | SMA905 |
| Optical Path Length | 10 mm |
| Base Material | Black Anodized Aluminum |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | FLB1012 |
| Price | Upon Request |
| Weight | 1200 g |
| Material | Black Anodized Aluminum |
| Dimensions | 150 mm (L) × 65 mm (W) × 65 mm (H) |
| Optical Interface | SMA905 |
| Adjustable Aperture Width | Up to 120 mm |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | FLB1034 |
| Pricing | Upon Request |
| Material | Aluminum Alloy + Stainless Steel Base |
| Base Dimensions | Ø200 mm × 20 mm |
| Max Adjustable Height | 200 mm |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | FLG1012 |
| Pricing | Available Upon Request |
| Connector Type | SMA905 |
| Core Diameter | 600 µm (customizable) |
| Numerical Aperture | 0.22 |
| Spectral Range | 180–2500 nm (customizable) |
| Standard Lengths | 0.5 m, 1.5 m (custom lengths available) |
| Fiber Type Options | UV-grade quartz, VIS-grade quartz, UV-VIS fused silica, armored fiber assembly |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | FLT1002 |
| Interface Options | Q9, 4-pin Aviation Connector, BNC, SMA |
| Spectral Range | 200–1100 nm (customizable) |
| Illuminance Measurement Range | 0.1–200,000 lx (dependent on integrating sphere configuration) |
| Relative Illuminance Error | < ±3% |
| Dimensions | 30 × 30 mm (customizable) |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | FLA Series |
| Detector Type | CCD |
| Configuration | Integrated with Sphere Series Integrating Sphere and FLA1200 Photometer |
| Application Scope | Real-time in-line laser characterization |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | FLA5100 |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | 722 |
| Price | USD 70 (approx.) |
| Optical Design | Single-beam |
| Detector | Photodiode Array |
| Wavelength Range | 330 nm – 1000 nm |
| Wavelength Adjustment | Manual |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Stray Light | ≤0.5% T at 360 nm |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SP7800 BTX & Oxygenates GC System |
| Pricing | Available Upon Request |
| Brand | Jingke Ruida |
|---|---|
| Model | WQF-520 |
| Type | Laboratory FTIR Spectrometer |
| Spectral Range | 400–7800 cm⁻¹ |
| Resolution | <0.85 cm⁻¹ |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Scan Speed | 0.2–2.5 cm/s (motor-controlled, continuously adjustable) |
| SNR | >15,000:1 (RMS, at 2100 cm⁻¹, 4 cm⁻¹ resolution, 60 s acquisition, DTGS detector) |
| Beamsplitter | Ge-coated KBr |
| Detector | Standard DTGS, optional MCT |
| Source | Air-cooled infrared source |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (PRC) |
| Model | UV-765 |
| Price | ¥2500 |
| Optical Design | Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Automation | Motorized Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | ≤0.05%T (at 220 nm with NaI |
| Brand | Jingpu Technology |
|---|---|
| Origin | Henan, China |
| Model | JP-AFL25B |
| Instrument Type | Portable |
| FTIR Architecture | Interferometric (Michelson-type) |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Wavenumber Accuracy | ≤0.01 cm⁻¹ |
| Signal-to-Noise Ratio (SNR) | >45,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Beam Splitter | Multi-layer coated KBr with hydrophobic coating |
| Detector | Dual-mode DTGS / MCT (user-selectable) |
| IR Source | Long-life air-cooled high-intensity broadband source |
| Scan Speed | Software-selectable, continuously variable (0.1–2.5 cm/s) |
| Optical Platform | Monolithic hardened aluminum base with integrated interferometer and detector chambers |
| Mirror System | Gold-coated corner-cube retroreflectors (monolithic, adhesive-free) |
| Environmental Protection | Industrial-grade resistive humidity control + physical desiccant barrier |
| Data Interface | USB 2.0/3.0 |
| OS Compatibility | Windows 7/10/11 (64-bit) |
| Software | IRPro v5.x (database-driven, ASTM E2412 & EN 14078 compliant modules included) |
| Certified Compliance | ISO 9001, AAA Measurement Management System, EMC-compliant per GB/T 18268.1–2010 (CNAS-verified) |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | GC_8890 |
| Instrument Type | Online Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient + 8 °C to 420 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | GC-2011 (Latest Revision) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Chemical Analysis |
| Oven Temperature Range | 8–420 °C |
| Oven Ramp Rate | 0.1–30 °C/min (0.1 °C/min increments) |
| Temperature Stability | ±0.1 °C within 200 °C |
| Carrier Gas Flow Control | Electronic Pressure Control (EPC)-compatible design |
| Carrier Gas Pressure Control | Supports precision pressure regulation |
| Cooling Rate | Rapid cool-down to near-ambient (≤200 °C) via intelligent variable-frequency rear door system |
| Column Compatibility | Packed columns and capillary columns (split/splitless injection) |
| Standard Detectors | FID and/or TCD |
| Dimensions | 540 × 455 × 465 mm |
| Weight | 50 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, 2 kW |
| Brand | Jinpu |
|---|---|
| Model | GC-2011 |
| Detector Options | FID or TCD |
| Temperature Control Range | 8 °C above ambient to 420 °C |
| Temperature Stability | ±0.1 °C (≤200 °C), ±0.2 °C (>200 °C) |
| Ramp Rate | 1–30 °C/min |
| Programmed Temperature | 5-step |
| FID Sensitivity | ≤2×10⁻¹¹ g/s (benzene), Linear Range: 10⁷ |
| TCD Sensitivity | ≥2500 mV·mL/mg (benzene) |
| Noise | ≤0.02 mV |
| Drift | ≤0.1 mV/h |
| Column Configuration | Single-column, dual-gas-path |
| Injector | Packed-column vaporizer + dedicated capillary inlet |
| Oven Cooling | Intelligent variable-frequency rear-door cooling to near-ambient |
| Safety Features | Overtemperature cutoff, gas failure/leak detection, power-fail parameter retention, anti-surge protection |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Online Gas Chromatograph |
| Model | GC-2011 |
| Detection Modes | FID & TCD |
| Column Compatibility | Packed Columns & Capillary Columns (Split/Splitless) |
| Oven Temperature Range | Ambient +8°C to 420°C |
| Temperature Control Accuracy | ±0.1°C (≤200°C), ±0.2°C (>200°C) |
| Programmable Ramp Stages | 8-step linear ramp |
| Ramp Rate | 0.1–30.0°C/min (0.1°C increments) |
| Detector Operating Temperatures | Up to 420°C |
| Injector Max Temp | 420°C |
| Carrier Gas Control | Digital pressure/flow regulation (N₂, H₂, He) |
| Power Supply | AC 220 V ±10%, 50 Hz, ~2 kW |
| Dimensions (W×D×H) | 540 × 455 × 465 mm |
| Weight | 50 kg |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose / EO Residual Testing |
| Temperature Control Range | 5°C above ambient to 400°C (adjustable in 0.1°C increments) |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increment) |
| Oven Cool-Down | 450°C → 50°C in ≤6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Signal Outputs | Dual analog (A/B), RJ45 Ethernet interface |
| Gas Inlets | H₂, Air, Optional H₂ supply lines |
| Power Input | Standard AC mains with integrated fuse and charging circuitry |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | GC-7890 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Coal Mining Industry |
| Detection Targets | H₂, O₂, N₂, CO, CO₂, CH₄, C₂H₄, C₂H₆, C₂H₂ |
| Minimum Detectable Concentrations | H₂ ≤ 5 ppm |
| TCD Sensitivity | ≥ 2500 mV·mL/mg (n-hexadecane) |
| FID Detection Limit | 5 × 10⁻¹² g/s (n-hexadecane) |
| Column Oven Temp Range | 10–399 °C (1 °C increment) |
| Control Accuracy | ±0.1 °C |
| Detector Temp Range | 10–399 °C |
| TCD Control Accuracy | ±0.01 °C |
| Data Acquisition | 24-bit A/D, USB interface, 6–50 Hz sampling rate, dynamic range 10⁶ |
| Dimensions | 606 × 450 × 450 mm (W×H×D) |
| Weight | 45 kg |
| Power Supply | 220 V, 50 Hz, 2100 W |