Chromatography Instruments
Filter
Showing 811–840 of 1564 results
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LC2000 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.002–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Autosampler Capacity | Not Specified (Front-Panel Manual Injection Interface) |
| Injection Volume Range | Not Specified |
| Column Oven Temperature Control Range | Not Specified |
| Wavelength Range (UV/VIS Detector) | 190–700 nm |
| Data Acquisition Frequency | Not Specified |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (PRC) |
| Model | LC2100 |
| Pricing | Upon Request |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LC2200 |
| Price | Upon Request |
| Pump Flow Range | 0.001–10.0 mL/min |
| Max Pressure | 6000 psi |
| Pump Accuracy | ±1% at 1 µL/min |
| Pump Precision | ±0.25% (0.1–10.0 mL/min) |
| UV Detector Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | <6 nm |
| Baseline Noise | <±2×10⁻⁵ AU |
| Baseline Drift | <4×10⁻⁴ AU (p-p) |
| D₂ Lamp Lifetime | 3500 h (1000 h warranty) |
| UV Detector Output | 0.0005–4 AU/mV (chart recorder), 4 AU/V (data system) |
| Power Supply (Pump) | 85–264 VAC, 47–63 Hz, 60 W |
| Power Supply (UV Detector) | 100–240 VAC, 50–60 Hz, 80 W |
| Dimensions & Weight | Pump — 5.9 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LC3000A |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Maximum Pressure (P3210) | 42 MPa |
| Maximum Pressure (P3220) | 30 MPa |
| Flow Rate Range (P3210) | 0.001–9.999 mL/min |
| Flow Rate Range (P3220) | 0.01–49.99 mL/min |
| Flow Accuracy | ≤0.4% |
| Flow Precision (RSD) | ≤0.1% |
| UV/VIS Detector (UV3000A) | Wavelength Range 190–700 nm |
| Light Source | Deuterium Lamp (standard), Tungsten Lamp (optional) |
| Wavelength Accuracy | ≤±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Absorbance Range | 0–2 AU |
| Absorbance Error | <±5% |
| Baseline Noise (254 nm) | ≤1.5×10⁻⁵ AU (dynamic, 1 mL/min, MeOH/H₂O 80:20) |
| Baseline Drift (254 nm) | ≤4×10⁻⁴ AU/h (dynamic, 1 mL/min, MeOH/H₂O 80:20) |
| Time Constants | 0.1/0.2/0.5/1/2/5/10 s |
| Auto-Zero Function | Full-scale |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LC3000A Preparative Liquid Chromatograph |
| Max. Pressure (P3210) | 42 MPa |
| Max. Pressure (P3220) | 30 MPa |
| Flow Rate Range (P3210) | 0.001–9.999 mL/min |
| Flow Rate Range (P3220) | 0.01–49.99 mL/min |
| Flow Accuracy | ≤0.4% |
| Flow Precision (RSD) | ≤0.1% |
| UV/VIS Detector Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ≤±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Absorbance Range | 0–2 AU |
| Absorbance Error | <±5% |
| Baseline Noise (254 nm) | ≤1.5×10⁻⁵ AU (dynamic, 1 mL/min, MeOH/H₂O = 80:20) |
| Baseline Drift (254 nm) | ≤4×10⁻⁴ AU/h (dynamic, 1 mL/min, MeOH/H₂O = 80:20) |
| Time Constants | 0.1/0.2/0.5/1/2/5/10 s |
| Scan Modes | Programmable stop-and-go wavelength scanning (start/end λ and step size user-definable) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SP-7800 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical GC |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Time | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | Ambient + 4 °C to 450 °C |
| Injector Pressure Setting Range | 0–100 psi (optional 0–150 psi) |
| Injector Total Flow Setting Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | SP6890 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Control Channels | 4 independent zones |
| Temperature Stability | ±0.1 °C |
| FID Detection Limit | ≤5.0×10⁻¹¹ g/s (benzene/CS₂) |
| TCD Sensitivity | ≥2500 mV·mL/mg (benzene) |
| Dimensions | 470 × 430 × 455 mm |
| Weight | ~45 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP6900 |
| Application Field | Petrochemical Industry |
| Temperature Control | 5 independent zones, 5-step programmable ramping |
| Column Oven Range | Ambient +15°C to 399°C |
| Temperature Stability | Better than ±0.1°C |
| Heating Rate | 0.1–40°C/min |
| Time Programming | 0–255 min per step |
| TCD Sensitivity | ≥3500 mV·mL/mg (benzene) |
| Baseline Noise | ≤0.02 mV |
| Drift | <0.1 mV/h |
| Weight | ~60 kg |
| Sample Introduction | 6-port gas sampling valve |
| Data Output | Real-time purity and component quantification via PC interface |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | SP7800 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UP2000 |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) with Online Solid-Phase Extraction (SPE) |
| Flow Rate Range | 0.001–20 mL/min |
| Maximum System Pressure | 25,000 psi |
| Autosampler Tray Capacity | 120 positions |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | Ambient +10 °C to 150 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | LABA (Tianjin Lab-Automation) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 440 nm and 570 nm |
| Flow Cell Volume | 10 µL |
| Brand | Lab-Antech (formerly LABA Tianjin) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 440 nm and 570 nm |
| Flow Cell Volume | 10 µL |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| System Model | AA9800 |
| Instrument Type | Post-Column Derivatization Amino Acid Analyzer |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 10 µL |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrumentation |
| Model | AA9800 Plus |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 10 µL |
| Brand | LABA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AA9800 Series |
| Price Range | USD 70,000–100,000 |
| Analyzer Type | Post-Column Derivatization |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 440 nm and 570 nm |
| Flow Cell Volume | 10 µL |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | G5 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal |
| Temperature Control Range | Ambient to 850 °C |
| Oven Ramp Rate | 0.01–500 °C/min |
| Oven Cool-down Rate | ~1 min (850 °C → 0 °C) |
| Carrier Gas Flow Range & Control | 0–25,000 mL/min |
| Carrier Gas Pressure Range & Control | 0.001–100,000 psi |
| Injector Maximum Operating Temperature | 850 °C |
| Injector Pressure Setting Range | 0.001–100,000 psi |
| Injector Total Flow Setting Range | 0.0001–10,000 mL/min |
| Detector Sensitivity (ECD) | ≤10⁻¹⁵ g/s (for γ-HCH) |
| Brand | LABA |
|---|---|
| Model | PC2001 |
| Origin | USA |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.01–100.00 mL/min |
| Maximum Pressure | 0–6000 psi |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | 1–80 µL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Detector Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | LABA (Tianjin LABA Co., Ltd.) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 20 / 80 / 200 / 500 |
| Application Level | Laboratory-Scale Preparative |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0–600 mL/min |
| Flow Accuracy | RSD < 0.06% |
| Flow Precision (Repeatability) | RSD < 0.06% |
| Maximum Operating Pressure | 25,000 psi |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Baseline Noise | 2.0 × 10⁻⁶ AU |
| Data Acquisition Rate | 500 Hz |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | Series 8000 |
| HPLC Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0–10 mL/min |
| Maximum Pressure | 9000 psi |
| Flow Precision | <0.1% RSD |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0–3 mL |
| Column Oven Temperature Range | (Ambient + 20°C) to 200°C |
| UV/Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 500 Hz |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | FC Jr |
| Dimensions | 28 cm (W) × 27 cm (H) × 31 cm (D) |
| Weight | 4.7 kg |
| Temperature Range | 0–40 °C |
| Step Timer Range | 1 s – 99 h 59 min 59 s |
| Drop Counter Range | 1–999,999 |
| Volume Counter Range | 1–999,999 units |
| Peak Detection Modes | Slope-based and/or plateau-based triggering, combinable with time windows |
| Time Windows per Program | Up to 10 |
| Tube Exchange Time (center-to-center) | 200–450 µs (dependent on tube diameter) |
| Program Storage | 9 full collection protocols with internal battery-backed memory |
| Interface | RS232 for LC system integration |
| Collection Modes | Time-based, drop-count-based, volume-based, and peak-triggered (UV/absorbance signal) |
| Collection Patterns | Linear (left-to-right) or spiral |
| Tube Holder Options | Compatible with 12–25 mm diameter tubes |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | Flash 150 |
| Maximum Flow Rate | 150 mL/min |
| Maximum Pressure | 200 psi |
| Detector | VUV14 Fixed-Wavelength UV Detector (254 nm) |
| Method Storage Capacity | 10 Predefined Gradient Methods + User-Programmable Gradients |
| Fluidic Path Material | 316 Stainless Steel |
| Fraction Collection | Integrated, Trigger-Based |
| Control Unit | Dedicated Embedded System with Touchscreen Interface |
| Compliance | Designed for GLP/GMP-adjacent laboratory environments |
| Software | Standalone instrument control with real-time data logging and method export capability |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | R1 |
| Dimensions | 35.6 × 31.1 × 33.0 cm (H×W×D) |
| Weight | 7.7 kg (without rack) |
| Max Flow Rate | 100 mL/min |
| Delay Volume | Micro-liter level (valve positioned at outlet of flow path) |
| Communication | Ethernet (TCP/IP) & RS-232 |
| Power | 100/117 VAC or 234 VAC, 50/60 Hz |
| Rack Options | 144×12 mm tubes |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HPLC 1500 Series |
| Price | Upon Request |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure | 6,000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.075% RSD |
| Gradient Precision | ±1% |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Range | D₂ Lamp (190–380 nm), W Lamp (366–800 nm) |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | HPLC 1500 |
| Flow Rate Range | 0.001–5 mL/min and 0.01–10 mL/min |
| Maximum Pressure | 6,000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.075% RSD |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Range | 190–380 nm (D₂ lamp), 366–800 nm (W lamp) |
| UV-Vis Detector Sensitivity | 0.0005–2.0 AUFS |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CP |
| Pricing | Available Upon Request |
| Pump Flow Range | 1–24 mL/min |
| Maximum Pressure | 10,000 or 18,000 psi |
| Pump Control Interface | RS-232 with pressure/flow sensors |
| Construction | Stainless Steel (SS) |
| Voltage | 110/220 V AC |
| Column Hardware Included | Two 4.6 × 150 mm stainless steel column assemblies (including endfittings, frits, and 2 µm stainless steel frits) |
| Slurry Vessel | 20 mL agitated slurry reservoir |
| Packing Accessories | Compression ferrules, metal bands, reducing adapters, O-rings, 1/16″ OD × 0.03″ ID stainless steel tubing |
| Stationary Phase | 10 g C18 silica-based packing material |
| Software | Quick-Set pump control software |
| Compliance | Designed for GLP-compliant column manufacturing environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-2000 |
| Pricing | Available Upon Request |
| Maximum Pressure | 6000 psi |
| Flow Rate Range | 0.01–9.99 mL/min |
| Flow Accuracy | ±0.1% |
| Baseline Noise (UV-VIS) | 0.2 × 10⁻⁵ AU |
| Baseline Drift (UV-VIS) | 2 × 10⁻⁴ AU/hr |
| Pump Technology | SSI III Dual-Piston Positive Displacement with Patented Online Self-Cleaning Mechanism |
| Upgrade Path | Compatible with Second Pump for Binary Gradient Configuration |
| Detector Standard | Model 500 UV-Vis Variable Wavelength Detector (190–700 nm) |
| Software | LabAlliance Chromatography Data System (CDS) with Audit Trail & Electronic Signature Support per FDA 21 CFR Part 11 |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | PC-2000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–40 mL/min |
| Maximum Pressure | 6000 psi |
| Sample Injection Positions | 120 |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 99 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | PC2001 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–20.000 mL/min (configurable for 10 mL/min or 80 mL/min total flow via pump head interchange) |
| Maximum Pressure | 6000 psi |
| Injection Positions | 120 |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 150 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Pressure Accuracy | ±1% of full-scale pressure |
| Flow Accuracy | ±2% |
| Flow Precision | ≤0.2% RSD |
| Baseline Noise | <±1.0×10⁻⁵ AU |
| Baseline Drift | <2.0×10⁻⁴ AU/hr |
| Wavelength Accuracy | ±1.0 nm |
| Brand | LabAlliance |
|---|---|
| Origin | USA |
| Model | SCS-200 |
| Instrument Type | Ambient-Temperature GPC Cleanup System |
| Pump Flow Rate | 0.01–9.99 mL/min |
| Maximum Pressure | 2500 psi (pump), 1500 psi (column) |
| Flow Path Materials | 316 Stainless Steel, Ceramic, Inert Polymer |
| Injector | Adjustable 2 mL Manual Injector with Valve Position Sensing & Loop Interface |
| Column Dimensions | 250 × 16 mm (customizable) |
| Packing Material | PS-DVB Copolymer |
| Pore Size | 50 nm |
| Particle Size | 10 µm |
| Max Operating Temperature | 60 °C |
| Sample Load Capacity | 300 mg |
| Fraction Collector | Three-Position Electronic Solenoid Valve |
| Control Interface | Front-Panel SCU + RS-232 Serial Communication |
| Brand | LabAlliance |
|---|---|
| Origin | USA |
| Model | SSI/LabAlliance 340 |
| Flow Rate | Up to 40 mL/min |
| Detector | UV201 Variable Wavelength Detector with Adjustable Flow Cell (0–3 mm pathlength) |
| Pump Type | Dual-piston syringe pump with integrated low-pulse dampener |
| Sample Introduction | Rheodyne 3725(i) manual injection valve |
| Construction | Stainless steel fluidic path |
| Compliance | Designed for GLP-compliant preparative workflows |
| Software Control | Fully automated system control via dedicated chromatography software |