Cleaning & Disinfection Equipment
Filter
Showing 1081–1110 of 1144 results
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T25 |
| Tank Capacity | 25.8 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 400 W |
| Adjustable Power Range | 0–500 W (heating + ultrasonics combined) |
| Temperature Control Range | 20–80 °C |
| Timer Range | 1–20 min |
| Sound-Dampening Lid | Included |
| Drain Valve | Integrated |
| Construction | Full SUS304 Stainless Steel Tank & Housing |
| Internal Dimensions | 530 × 325 × 150 mm |
| External Dimensions | 550 × 330 × 310 mm |
| Net Weight | 14.5 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T25D |
| Type | General-purpose ultrasonic cleaner |
| Capacity | 25.8 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 500 W |
| Adjustable Power | Fixed at 500 W |
| Temperature Range | 0–80 °C |
| Timer Range | 1–99 min 59 sec |
| Sound-dampening Lid | Yes |
| Drain Port | Yes |
| Heating Power | 500 W |
| Inner Tank Dimensions | 530 × 325 × 150 mm |
| Overall Dimensions | 550 × 330 × 310 mm |
| Net Weight | 14.5 kg |
| Construction | Full SUS304 stainless steel tank and housing |
| Control System | Industrial-grade microcontroller with digital LED display |
| Rack | Stainless steel welded mesh basket included |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T3 |
| Tank Capacity | 3.3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 100 W (fixed) |
| Timer Range | 1–20 min |
| Lid | Sound-dampening cover included |
| Drain | Manual valve |
| Construction | Stainless steel (SUS304) tank and housing |
| External Dimensions | 270 × 170 × 240 mm |
| Internal Tank Dimensions | 240 × 140 × 100 mm |
| Net Weight | ~3.45 kg |
| Heating Function | Not available |
| Power Adjustment | Not applicable (fixed 100 W) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T34 |
| Type | General-purpose ultrasonic cleaner |
| Capacity | 34.4 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 500 W |
| Adjustable Power | Fixed at 500 W |
| Temperature Range | 20–80 °C |
| Timer Range | 1–20 min |
| Sound-reducing Lid | Yes |
| Drain Port | Yes |
| Tank Dimensions (L×W×H) | 530 × 325 × 200 mm |
| Overall Dimensions (L×W×H) | 550 × 330 × 358 mm |
| Heating Power | 500 W |
| Construction | SUS304 stainless steel tank and housing |
| Net Weight | ~14.5 kg |
| Gross Weight | ~15.5 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T34D |
| Type | General-purpose ultrasonic cleaner |
| Tank Capacity | 34.4 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 500 W (adjustable in fixed-step mode) |
| Heating Range | 0–80 °C (digitally adjustable) |
| Timer Range | 1 min – 99 min 59 sec |
| Sound-dampening Lid | Included |
| Drain Port | Integrated |
| Tank Dimensions (L×W×H) | 530 × 325 × 200 mm |
| Overall Dimensions (L×W×H) | 550 × 330 × 358 mm |
| Net Weight | 14.5 kg |
| Gross Weight | 15.2 kg |
| Construction | Full SUS304 stainless steel tank and housing |
| Control System | Industrial-grade microcontroller with digital LED display |
| Basket | Welded stainless steel mesh rack |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T3D |
| Tank Capacity | 3.3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 100 W |
| Heating Power | 100 W |
| Temperature Range | 0–80 °C |
| Timer Range | 1–99 min 59 sec |
| Adjustable Power | No |
| Adjustable Temperature | Yes |
| Adjustable Timer | Yes |
| Sound-Reducing Lid | Included |
| Drain Port | None |
| Construction | SUS304 Stainless Steel Tank & Housing |
| Control System | Industrial-Grade Microcontroller |
| Display | Digital LED (Time & Temperature) |
| Net Weight | ~5.5 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T7 |
| Type | General-purpose ultrasonic cleaner |
| Capacity | 7.0 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 150 W |
| Adjustable Power | Up to 300 W (heating only) |
| Temperature Control Range | 20–80 °C |
| Timer Range | 1–20 min |
| Sound-dampening Lid | Included |
| Drain Port | Yes |
| Tank Dimensions (L×W×H) | 300 × 155 × 150 mm |
| Overall Dimensions (L×W×H) | 330 × 180 × 310 mm |
| Net Weight | 5.45 kg |
| Construction | Full SUS304 stainless steel tank and housing |
| Stainless Steel Mesh Basket | Included |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T7D |
| Tank Capacity | 7.0 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 150 W |
| Heating Power | 300 W |
| Temperature Range | 0–80 °C |
| Timer Range | 1–99 min 59 sec |
| Built-in Drain Port | Yes |
| Sound-Insulating Lid | Yes |
| Construction | Full SUS304 Stainless Steel |
| Internal Tank Dimensions | 300 × 155 × 150 mm |
| External Dimensions | 330 × 180 × 310 mm |
| Net Weight | 5.5 kg |
| Brand | TTL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TTL-100 |
| Chamber Volume | 10 L |
| Heating Power | 120 W |
| Temperature Control | Thermostatically Maintained |
| Compatible Cleaning Solvents | Organic Solvents (e.g., Acetone, Methanol, Isopropanol) |
| External Dimensions (L×W×D) | 540 × 500 × 845 mm |
| Power Supply | AC 220 V, 50 Hz |
| Max. Batch Capacity | ≤97 × 2 mL Chromatography Vials (OD 11.05 ± 0.5 mm, Height 32 ± 1 mm) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CS-24 |
| Price | USD 4,500 (FOB Jiangsu) |
| Capacity | 24 L |
| Heating Power | 1500 W |
| Temperature Range | Ambient to 100 °C (optional refrigeration module available) |
| Temperature Accuracy | ±0.5 °C |
| Timer Range | 0–99 h 59 min |
| Ultrasonic Power Output | 600 W (adjustable, 40 kHz nominal frequency) |
| Drain Valve | Integrated |
| Sound-Dampening Lid & Stainless Steel Mesh Basket | Included |
| Power Supply | 220 V AC, 50 Hz |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CSTHZ-82 |
| Price | USD 3,900 (FOB Jiangsu) |
| Temperature Control Range | RT–100 °C (digital display) |
| Oscillation Amplitude | 20 mm |
| Speed Control | Digital Display |
| Ultrasonic Frequency | 40 kHz |
| [Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Origin | Yes |
| Model | QT15360 / QTR15360 / QT15360K / QTSXR15360 |
| Capacity | 15 L |
| Ultrasonic Frequency | 40 kHz |
| Tank Material | 304 Stainless Steel (Deep-drawn) |
| External Housing | Anodized Aluminum with Anti-corrosion Coating |
| Internal Dimensions | 300 × 240 × 200 mm |
| Overall Dimensions | 410 × 270 × 300 mm |
| Ultrasonic Power Output | 400 W |
| Power Adjustment | Dual-mode (200/400 W) or Continuous 20–100% |
| Timer Range | 0–30 min (Basic), 1–20 min (Heated), 1–99 min (Digital), or Adjustable Degassing Cycle |
| Heating Power | 600 W (Heated & Digital Models Only) |
| Temperature Control Range | 0–80 °C (Heated Models) |
| Display | LED (Heated & Digital Models) |
| Drain Port | Optional (Digital Model) |
| Net Weight | 8.0 kg |
| Gross Weight | 10.0 kg |
| Standard Accessories | Stainless Steel Lid & Basket |
| Color | Bright White] |
| Key | Origin: Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | QT1000 (Non-Heating) / QTR1000 (Heating) |
| Capacity | 72 L |
| Ultrasonic Frequency | 40 kHz |
| Tank Material | 1.5 mm thick AISI 304 stainless steel (deep-drawn) |
| External Dimensions | 700 × 460 × 760 mm |
| Internal Tank Dimensions | 600 × 300 × 400 mm |
| Ultrasonic Power Output | 1000 W (adjustable 20–100% in 10% increments) |
| Timer Range | 0–30 min |
| Transducer Count | 20 piezoelectric units (bottom-mounted) |
| Drain Valve | Integrated brass valve with hose fitting |
| Heating Power (QTR1000 only) | 1000 W, temperature control 0–80 °C |
| Net Weight | 60.0 kg |
| Gross Weight | 90.0 kg |
| Standard Accessories | Stainless steel noise-reducing lid |
| Packaging | Reinforced export-grade wooden crate |
| Compliance | CE-marked per EN 61000-6-3 (EMC), EN 61000-6-2 (Immunity), and EN 60335-1 (Safety) |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QT30600 / QTR30600 / QT30600K / QTSXR30600 |
| Pricing | Available Upon Request |
| Capacity | 30 L |
| Ultrasonic Frequency | 40 kHz |
| Tank Material | 304 Stainless Steel (Deep-Drawn) |
| External Housing | Anodized Aluminum with Corrosion-Resistant Coating |
| Internal Dimensions | 500 × 300 × 200 mm (L×W×H) |
| Overall Dimensions | 610 × 350 × 380 mm (L×W×H) |
| Timer Range | 0–30 min (QT30600), 1–20 min (QTR30600), 1–99 min (QT30600K & QTSXR30600) |
| Ultrasonic Power Output | 600 W (fixed) |
| Adjustable Power Output | None (QT30600), 20–100% (QTR30600 & QTSXR30600), 40–99% (QT30600K) |
| Heating Power | None (QT30600), 800 W (QTR30600 & QTSXR30600) |
| Temperature Control Range | 0–80 °C (heating models only) |
| Display | None (QT30600), LED Digital Display (QTR30600, QT30600K, QTSXR30600) |
| Drain Fitting | Not Included |
| Net Weight | 20.0 kg |
| Gross Weight | 28.0 kg |
| Standard Accessories | Stainless Steel Lid & Rack |
| Color | Bright White |
| Key Components | Fairchild Semiconductor (USA) ICs and Driver Modules |
| Warranty | 3-Year Limited Warranty, Lifetime Technical Support |
| Brand | PEA |
|---|---|
| Origin | Germany |
| Type | Imported Equipment |
| Hydrogen Peroxide Concentration | 35% w/w |
| Vaporization Rate | 16 g/min |
| Air Flow Rate | 120 m³/h |
| Sterilization Volume Range | 1–600 m³ |
| Vaporization Temperature | 100 °C |
| Dehumidification Setpoint | 35–40% RH |
| Final H₂O₂ Residual Level | <1 ppm |
| Filtration Efficiency | ≥99.999% at 0.2 µm (HEPA/ULPA-grade) |
| Log Reduction | ≥6-log for Geobacillus stearothermophilus spores |
| Sterility Assurance Level (SAL) | ≤10⁻⁶ |
| Brand | Vigor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Vigor Single-Station Glove Box (Flexible Solar Cell Application) |
| Pricing | Available Upon Request |
| Brand | Vigor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Vigor Single-Station Vacuum Glove Box |
| Instrument Classification | Vacuum Glove Box |
| Filtration Class | ISO Class 2 (≤0.05 vol%/h leakage rate) |
| FFU Configuration | Integrated Fan + H14 HEPA Filter + Dual-Layer Perforated Floor + Rear Gas Return Duct |
| Airflow Pattern | Unidirectional Downward Flow (UDF) with Full-Volume Coverage via Top-Mounted Flow Distributor |
| Sealing System | Patented Multi-Point Dynamic Gasket Seal |
| Gas Purification | Integrated Catalytic Oxygen/H₂O Scrubbing Module (O₂ < 1 ppm, H₂O < 1 ppm after stabilization) |
| Control System | Embedded Industrial PLC with Touchscreen HMI, Real-Time Atmosphere Monitoring (O₂, H₂O, Pressure), and Audit-Trail-Enabled Logging |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Autoloop Pro |
| Sterilization Time Range | 1–15 s |
| Cooling Time Range | 1–45 s |
| Control | Microprocessor-based with LED display & optical sensor feedback |
| Rotation Capacity | 1–4 loops |
| Flame Intensity | 2 adjustable levels |
| Auto-shutdown | 15 min / 1 h |
| Rotation Direction | Adjustable (left/right) |
| Construction | Stainless steel housing with heat-resistant tempered glass display cover |
| Dimensions (W×D×H) | 135 × 180 × 305 mm |
| Weight | 1200 g |
| Compliance | Designed for ISO 13485-aligned lab workflows, compatible with GLP/GMP documentation requirements via timestamped operation logs |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Autoloop Pro |
| Sterilization Method | Flame-based (compatible with WIGGENS Fuego Bunsen burners) |
| Control System | Microprocessor-controlled with LED interface |
| Loop Capacity | 1–4 loops |
| Sterilization Time Range | 1–15 s (adjustable in 1-s increments) |
| Cooling Time Range | 1–45 s (adjustable in 1-s increments) |
| Auto-Shutdown | Yes (configurable: 15 min or 1 hr) |
| Rotation Direction | Bidirectional (left/right selectable) |
| Flame Intensity | Two preset levels |
| Status Indication | Dual-color LED (red = hot, green = cooled) |
| Construction | Stainless steel housing with heat-resistant tempered glass display cover |
| Dimensions (W×D×H) | 135 × 180 × 305 mm |
| Weight | 1200 g |
| Compliance | Designed for GLP-compliant microbiological workflows |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Dragon 200 |
| Fuel Type | Liquefied Petroleum Gas (LPG) / Natural Gas |
| Fuel Consumption | 0.2 kg/h (LPG) |
| Maximum Flame Temperature | 1350 °C (LPG) |
| Fuel Capacity | 45 g (butane) |
| Continuous Operation Time | 60 min |
| Dimensions (L×W×H) | 92 × 115 × 79 mm |
| Net Weight | 407 g |
| Ignition | Electronic Piezoelectric Igniter |
| Flame Adjustment | Continuously Variable Air/Gas Ratio Control |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Dragon 220 |
| Fuel Type | n-Butane |
| Fuel Consumption | 45 g per 60 min |
| Maximum Flame Temperature | 1300 °C |
| Fuel Capacity | 45 g |
| Continuous Operation Time | 60 min |
| Dimensions (L×W×H) | 94 × 115 × 78 mm |
| Net Weight | 425 g |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Dragon |
| Maximum Temperature | 1300 °C |
| Fuel Type | Refillable n-Butane Cartridge |
| Ignition System | Piezoelectric Spark Ignition |
| Flame Adjustment | Continuous Rotary Valve Control |
| Safety Feature | Automatic Gas Cutoff Upon Button Release |
| Continuous Operation Time | 60 min |
| Dimensions (L×W×H, mm) | Dragon 100: 161×137×79 |
| Dragon 200 | 92×115×79 |
| Dragon 220 | 94×115×78 |
| Net Weight | Dragon 100: 380 g |
| Dragon 200 | 407 g |
| Dragon 220 | 425 g |
| Fuel Capacity | 45 g n-Butane |
| Compliance | CE-marked per EN 61000-6-3 (EMC) and EN 61000-6-1 (Immunity) |
| Designed in accordance with ISO 8573-1 | 2010 for clean gas handling in microbiological applications |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Dragon |
| Maximum Flame Temperature | 1300 °C |
| Fuel Consumption | 45 g/h |
| Compatible Fuel | n-Butane |
| Ignition Type | Piezoelectric Electronic Ignition |
| Design Variant | Tabletop (Dragon 200 & Dragon 220), Angled Flame Configuration (Dragon 220) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Dragon100 |
| Fuel Type | n-Butane |
| Fuel Consumption | 45 g per 60 min |
| Maximum Flame Temperature | 1300 °C |
| Fuel Capacity | 45 g |
| Continuous Operation Time | 60 min |
| Dimensions (L×W×H) | 161 × 137 × 79 mm |
| Net Weight | 380 g |
| Safety Ignition Switch | Integrated Piezoelectric Igniter |
| Flame Adjustment | Continuously Variable Needle Valve |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model Range | UE03 / UE06 / UE10 / UE15 / UE22 |
| Capacity | 3–22 L |
| Ultrasonic Frequency | 37 kHz |
| Ultrasonic Power | 100–400 W (effective) |
| Heating Power | 88–550 W |
| Temperature Range | 20–80 °C |
| Timer Range | 1–99 min |
| Tank Material | Full Stainless Steel (AISI 304) |
| Drain Valve | Manual (present on UE06 and above) |
| Lid | Acoustic-Dampening Cover |
| Compliance | For non-medical laboratory use only |
| Standards | Designed in accordance with IEC 61010-1 for laboratory electrical safety |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Ecoloop |
| Control Mode | Manual |
| Rotation Mechanism | Motorized, Bidirectional (Left/Right Adjustable) |
| Sterilization Method | Open-flame thermal sterilization using compatible WIGGENS-Fuego Bunsen burners |
| Detection System | Integrated optical sensor for loop presence/absence detection |
| Auto Shut-off | Yes, configurable at 15 min or 60 min |
| Flame Intensity Settings | 2 levels |
| Post-sterilization Cooling Options | 2 selectable durations |
| Status Indication | Dual-color LED (red = hot, green = cooled) |
| Construction Material | Stainless steel |
| Dimensions (W×D×H) | 120 × 150 × 395 mm |
| Weight | 1800 g |
| Compliance | Designed for ISO 13485-aligned lab environments |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Ecoloop |
| Control Mode | Manual |
| Rotation Mechanism | Motorized, Bidirectional (Left/Right Adjustable) |
| Sterilization Time Range | 1–15 s |
| Cooling Time Range | 1–45 s |
| Auto-Shutdown | Yes (15 min / 1 h selectable) |
| Detection System | Integrated Optical Sensor for Loop Presence/Absence |
| Flame Intensity Settings | 2 Levels |
| Post-Sterilization Status Indication | Dual-Color LED (Red = Hot, Green = Cooled) |
| Construction Material | Stainless Steel |
| Dimensions (W×D×H) | 120 × 150 × 395 mm |
| Weight | 1800 g |
| Compatibility | All WIGGENS-Fuego Bunsen Burners |
| Mounting | Benchtop or Cleanbench Integrated Fixture |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Fuego Basic |
| Gas Supply | Liquefied Petroleum Gas (LPG) 20–50 mbar / Natural Gas E/LL 18–25 mbar |
| Maximum Flame Temperature | 1350 °C (LPG), 1300 °C (Natural Gas) |
| Gas Consumption | 70 g/h |
| Power Input | 100–240 V, 50/60 Hz, ≤0.3 A |
| Dimensions | 103 × 49 × 130 mm |
| Weight | 700 g |
| Safety Certification | DIN EN 13861, CE, EEC |
| Ignition Nozzle Diameter | Ø23 mm |
| Control | Microprocessor-based rotary knob + wired footswitch (standard) |
| Housing | One-piece stainless steel, fully insulated external components |
| Tilt Function | Left/right manual tilt via spring-loaded base plate |
| Sterilization Accessories | Rear-mounted sterilization needle holder, swivel-lock gas connector, included tools (screwdriver & wrench), universal power adapter kit |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Fuego Basic RF |
| Max. Flame Temperature | 1350 °C (LPG), 1300 °C (Natural Gas) |
| Gas Consumption | 70 g/h |
| Adjustable Gas Pressure Range | LPG 20–50 mbar, Natural Gas E/LL 18–25 mbar |
| Power Supply | 100–240 V AC, 50/60 Hz, ≤0.3 A |
| Dimensions | 103 × 49 × 130 mm |
| Weight | 700 g |
| Compliance | DIN EN ISO/IEC 17025, CE, EEC |
| Safety System | SCS (Safety Control System) with flame monitoring, overheat protection, and gas cutoff |
| Ignition | Piezoelectric, 23 mm burner orifice |
| Operating Modes | Rotary knob control + wireless footswitch (2–5 m range, AA battery–powered) |
| Accessories | Sterilization needle holder, left/right tilt mechanism, dual-gas inlet (natural gas & propane/butane), rotating-lock gas hose connector, tool set, universal power adapter |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Fuego SCS |
| Max. Flame Temperature | 1350 °C (LPG), 1300 °C (Natural Gas) |
| Gas Consumption | 70 g/h |
| Gas Supply Pressure | LPG 20–50 mbar, Natural Gas E/LL 18–25 mbar |
| Power Input | 100–240 V AC, 50/60 Hz, ≤0.3 A |
| Rated Power | 1 kW |
| Dimensions | 103 × 49 × 130 mm |
| Weight | 700 g |
| Safety Compliance | DIN EN 61000-6-3, DIN EN 61000-6-4, CE, EEC |
| Control Interface | Microprocessor-based LCD with graphical navigation, IR sensor, rotary knob, optional footswitch (order separately) |