Color Difference Meter
Filter
Showing 361–390 of 562 results
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | UltraScan VIS Platinum-Cobalt / Gardner / Color Measurement Instrument |
| Product Type | Colorimeter |
| Instrument Form Factor | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360 nm – 780 nm |
| Repeatability | ΔE* ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | UltraScan VIS |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° (Diffuse/8°) Integrating Sphere |
| Illuminant | Full-Spectrum LED |
| Spectral Range | 400–700 nm |
| Wavelength Interval | 10 nm |
| Repeatability (ΔE*ab) | ≤ 0.03 |
| Data Output | CIE L*a*b*, L*C*h°, ΔE*ab, ΔE00, Whiteness (CIE, Ganz, ASTM E313), Yellowness (ASTM D1925, ASTM E313), Haze, Opacity, Transmittance, Reflectance |
| Compliance | ISO 7724, ISO 11664, ASTM E308, ASTM D2244, ASTM E2539, CIE No. 15 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan VIS |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 10 nm |
| Repeatability (ΔE*ab) | ≤0.01 |
| Compliance | ASTM E308, ISO 7724, CIE No. 15, USP <1061>, FDA 21 CFR Part 11 ready (with optional software module) |
| Data Output | L*, a*, b*, ΔE*ab, ΔE00, Whiteness (CIE, Hunter), Yellowness (ASTM E313), Opacity, Haze, Transmittance, Reflectance, Gloss (with optional gloss probe) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | UltraScan VIS |
| Product Type | Benchtop Spectrophotometric Colorimeter |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*₀₀ ≤ 0.03 |
| Color Spaces | CIELAB, CIELCh, Hunter Lab, XYZ, Yxy, ANLAB, Rdab |
| Color Difference Formulas | ΔE*₂₀₀₀, ΔE*₉₄, ΔE*CIE76, ΔE*CMC(2:1), ΔE*CMC(1:1), ΔE*FMC2, ΔH*, ΔC*, ΔL* |
| Indices | APHA, Gardner, Saybolt, Whiteness (CIE, Ganz, ASTM E313), Yellowness (ASTM D1925, E313), Opacity, Haze, Tint, TPS/TCS/TJS/TSS (Tomato/Citrus), ASBC/EBC, ASTM D6290 (Infrared Reflectance), Fluorescent Whitening Agent (FWA) Compensation |
| Data Output | Reflectance (%), Absorbance, Transmittance (%), K/S, Color Strength, Optical Density |
| Illuminants | A, C, D50, D65, D75, F2, F7, F11, TL84, U3000, U3500, ULTRALUME |
| Compliance | ISO 7724-1, ISO 11664, ASTM E308, ASTM D2244, ASTM D313, ASTM E2539, CIE No. 15, FDA 21 CFR Part 11 (via optional software module), GLP/GMP audit trail capable |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HunterLab UltraScan VIS |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360–780 nm |
| Wavelength Interval | 10 nm |
| Spectral Bandwidth | 10 nm (Effective Equivalent Triangular) |
| Wavelength Accuracy | Verified with Nd/Pr Oxide Filter |
| Repeatability | ≤0.03 ΔE* (CIE L*a*b*, avg. of 10 readings on white tile) |
| Photometric Range | 0–150% |
| Photometric Resolution | 0.003% (displayed as 0.01%) |
| Measurement Time | ≤5 s |
| Aperture Options | 19 mm and 6.3 mm |
| Transmission Chamber | Triple-side open, accommodates up to 80 mm cuvettes |
| UV Correction | Yes, D65 UV-adjustable |
| Compliance | CIE, ASTM E308, ISO 7724, ISO 11664, DIN 5033, JIS Z 8722, USP <631> |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan VIS (USVIS) |
| Type | Benchtop Spectrophotometer |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360–780 nm |
| Repeatability | ΔE* ≤ 0.03 |
| Product Category | Spectrophotometric Color Measurement Instrument |
| Compliance | ASTM, ISO, USP, CIE, GB/T, SH/T, NB/SH/T standards |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan VIS Textile Colorimeter |
| Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360–780 nm |
| Repeatability | ΔE* ≤ 0.03 (CIELAB, LAV/SAV, 20 readings on white tile) |
| Wavelength Resolution | < 0.3 nm |
| Wavelength Accuracy | ±0.1 nm |
| Effective Bandwidth | 10 nm |
| Photometric Range | 0–200% |
| Photometric Resolution | 0.003% (reported as 0.01%) |
| Lamp Lifetime | > 1,000,000 flashes |
| Measurement Time | < 1 s |
| Minimum Interval Between Measurements | 3 s |
| Compliance | CIE No. 15, ISO 7724-1, ASTM E1164, DIN 5033-7 (reflectance & transmittance) |
| Dimensions (H×W×D) | 27.9 × 42.0 × 49.8 cm |
| Weight | 20.4 kg |
| Power | 100–240 VAC, 47–63 Hz |
| Interface | RS-232C, 9600 baud, DB9 female |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan VIS Yellowness Index Analyzer |
| Product Type | Spectrophotometric Color & Transmittance Meter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360–780 nm |
| Spectral Resolution | 10 nm |
| Repeatability (ΔYI) | ≤0.03 |
| Measurement Modes | Reflectance (with/without specular component), Transmittance, Yellowness Index (YI E313, YI ASTM D1925), L*a*b*, ΔE*ab, %T, %R |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | USPRO |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp (CIE Illuminant D65) |
| Spectral Range | 350–1050 nm |
| Spectral Resolution | <2 nm |
| Bandwidth | 5 nm |
| Reflectance/Transmittance Range | 0–150% |
| Repeatability | ΔE* < 0.03 in CIE L*a*b* on certified white tile |
| Aperture Sizes | 25 mm (LAV), 13 mm (MAV), 7 mm (SAV) with auto-switching and dual-focus lens |
| UV Control | 400 nm cut-off filter, automatic UV calibration and status tracking |
| Measurement Chamber | Large transmission compartment (35.6 × 16.5 × 10.2 cm), tri-directional sliding door |
| Sample Viewing Window | Illuminated |
| Detector | 512-element silicon photodiode array with precision double-layer diffraction grating |
| Sphere Diameter | 6-inch |
| Internal Coating | Spectraflect® patented non-yellowing, abrasion-resistant coating |
| Software | EasyMatch QC (Windows-compatible) |
| Compliance | Fully supports ASTM E308, ISO 11664, CIE No. 15, USP <1061>, and GLP/GMP audit trail requirements |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | USPRO |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350–1050 nm |
| Repeatability | ΔE*ab ≤ 0.02 (mean, CIE Lab) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista Accessory Kit |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Form Factor | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Full-Spectrum LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.02 ΔE* |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista BPA Melt Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Full-spectrum LED array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.025 ΔE* (30 measurements) |
| Compliance | ASTM E1164, ASTM D1003, CIE 15:2004, DIN 5033-7, JIS Z 8722 Condition E, ISO 7724, USP <631>, EP 2.2.29 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista BPA Melt Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Full-spectrum LED array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.025 ΔE* (30 measurements) |
| Compliance | ASTM E1164, ASTM D1003, CIE 15:2004, DIN 5033-7, JIS Z 8722 Condition E, ISO/CIE 11664 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista BPA-Specific Colorimeter |
| Product Type | Benchtop Color Difference Meter |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Full-Spectrum LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.02 ΔE* |
| Compliance | ASTM D1003 (Haze), ASTM E1164, CIE 15:2004, DIN 5033-7, JIS Z 8722 Condition E, ISO/CIE S002 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.02 ΔE* |
| Compliance | ASTM D1003 (Haze), ASTM E1164, CIE 15:2004, ISO/CIE 11664, JIS Z 8722 Condition E, DIN 5033 Teil 7 |
| Measurement Modes | Total Transmission (TTRAN), Regular Transmission (RTRAN), Haze, Saybolt, APHA/Pt-Co, Hazen, ASTM Color, Gardner, YI E313, ADMI, Lovibond Red/Yellow (LovR/LovY) |
| Spectral Resolution | < 3 nm |
| Effective Bandwidth | 10 nm |
| Photometric Range | 0–150% |
| Measurement Time | < 2.5 s (color), < 5 s (haze) |
| Path Length | 100 mm |
| Illumination/Measurement Area | 18.5 mm / 9.1 mm |
| Integrating Sphere Diameter | 76 mm |
| Detector | 256-element diode array with high-resolution concave holographic grating |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Distributor Status | Authorized Distributor |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Form Factor | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | LED |
| Spectral Range | 400–700 nm, 360–780 nm, or 350–1050 nm (model-dependent) |
| Repeatability | ΔE*₀₀ ≤ 0.03 (average, CIE L*a*b* color space) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | VTS-Vista |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Full-Spectrum LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | ≤ 0.02 ΔE* (30 measurements) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista DTD |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Full-spectrum LED array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.025 ΔE* (30 measurements) |
| Compliance | ASTM D1003 (haze), ASTM E1164, CIE 15:2004, ISO/CIE 11664, JIS Z 8722 Condition E, DIN 5033-7 |
| Illuminant/Observer | D65/10°, C/2° |
| Display | 1280 × 800 color touchscreen |
| Power | 100–240 VAC, 47–63 Hz, 60 W |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista |
| Instrument Type | Benchtop |
| Optical Geometry | 8°/diffuse (8/d) |
| Light Source | Full-Spectrum LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.02 ΔE* |
| Compliance | ASTM D1003 (Haze), ASTM E1164, CIE 15:2004, ISO/CIE 11664, JIS Z 8722 Condition E, DIN 5033 Teil 7 |
| Measurement Modes | Total Transmission (TTRAN), Regular Transmission (RTRAN), Haze |
| Display | 1280×800 Color Touchscreen |
| Power Supply | 100–240 VAC, 47–63 Hz, 60 W |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | HunterLab Vista Electrolyte Additive Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Full-spectrum LED array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.025 ΔE* (30 measurements) |
| Compliance | ASTM D1003 (haze), ASTM E1164, CIE 15:2004, ISO/CIE 11664, JIS Z 8722 Condition E, DIN 5033-7 |
| Color Scales | CIE L*a*b*, LCh, Yxy, XYZ |
| Measurement Modes | Total transmittance (TTRAN), Regular transmittance (RTRAN), Haze, Color, Yellowness, Turbidity indices |
| Spectral Resolution | < 3 nm FWHM |
| Effective Bandwidth | 10 nm |
| Photometric Range | 0–150% |
| Measurement Time | < 2.5 s (color), < 5 s (haze) |
| Illuminant/Observer | D65/10°, C/2° |
| Display | 1280 × 800 high-res color touchscreen |
| Power | 100–240 VAC, 47–63 Hz, 60 W |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista Ethylene Glycol Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Full-spectrum LED array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.02 ΔE* |
| Compliance | ASTM D1003 (haze), ASTM D1209 (APHA), ASTM D1500 (ASTM Color), ASTM D5386 (color measurement of liquids), ISO 11475, ISO 11664 series |
| Color Scales | CIE L*a*b*, Hunter Lab, CIE LCh, CIE Yxy, CIE XYZ |
| Color Difference Metrics | ΔE*, ΔE₀₀ (CIE DE2000), ΔE CMC (2:1), ΔL*a*b*, ΔL*C*h*, ΔYxy, ΔXYZ |
| Color Indices | APHA/Pt-Co, Hazen, ASTM D1500, Saybolt, Gardner, YI E313, YI D1925, ADMI, Lovibond Red (LovR), Lovibond Yellow (LovY), Haze (%) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista Film Color and Haze Spectrophotometer |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.02 ΔE* |
| Compliance | ASTM D1003, ASTM E1164, CIE 15:2004, DIN 5033-7 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista Gardner Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.02 ΔE* |
| Compliance | ASTM D1003 (Haze), ASTM D1209 (APHA), ASTM D6166 (Gardner), ISO 11475, ISO 4630, USP <631>, FDA 21 CFR Part 11 (software-enabled) |
| Color Scales | CIE L*a*b*, Hunter Lab, CIE LCh, CIE Yxy, CIE XYZ, APHA/PtCo, ASTM D1500, Saybolt, Gardner, YI E313, YI D1925, ADMI, Lovibond Red/Yellow (LovR/LovY), Haze (%) |
| Illuminant/Observer | D65/10°, C/2° |
| Display | 1280×800 High-Resolution Color Touchscreen |
| Power | 100–240 VAC, 47–63 Hz, 60 W |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista Haze and Color Spectrophotometer |
| Instrument Type | Benchtop |
| Optical Geometry | 8°/diffuse (d) |
| Light Source | Full-spectrum LED |
| Spectral Range | 400–700 nm |
| Repeatability | Standard deviation ≤ 0.1% |
| Compliance | ASTM D1003 for haze measurement |
| Sample Measurement Modes | Transmission (liquids, films, solids) |
| Wavelength Accuracy | Verified with Nd-Pr filter set |
| Chamber Design | Triple-side open transmission compartment |
| Footprint | Compact benchtop form factor |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista Liquid Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Full-Spectrum LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.02 ΔE* |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista Molten Color Analyzer (GB/T 6324.7-2014) |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Full-spectrum LED array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | ≤ 0.02 ΔE* (30 measurements) |
| Compliance | GB/T 6324.7-2014, GB/T 3143, GB/T 3676, GB/T 28113, ASTM E1164, ASTM D1003, CIE 15:2004, ISO/CIE 11664 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Vista |
| Instrument Type | Benchtop Colorimeter |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Full-Spectrum LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | 0.02 ΔE* |
| Compliance | GB/T 6234.7–2014, GB/T 28113–2011, ASTM E1164, CIE 15:2004, ASTM D1003 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | HunterLab Vista Pesticide Intermediate Colorimeter |
| Product Type | Color Difference Meter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Full-Spectrum LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | 0.02 ΔE* |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | HunterLab Vista Pharmaceutical Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | 8°/diffuse (8/d) |
| Light Source | Full-spectrum LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | < 0.02 ΔE* |
| Compliance | ASTM D1003 (Haze), ASTM E1164, CIE 15:2004, ISO/CIE 11664, JIS Z 8722 Condition E, DIN 5033 Teil 7 |
| Illuminant/Observer | D65/10°, C/2° |
| Color Scales | CIE L*a*b*, Hunter Lab, CIE LCh, CIE Yxy, CIE XYZ |
| Color Difference Metrics | ΔE*, ΔE₀₀ (CIEDE2000), ΔE CMC (2:1), ΔL*a*b*, ΔL*C*h* |
| Color Indices | APHA/PtCo, Hazen, ASTM D1500, Saybolt, Gardner, YI E313, YI D1925, ADMI, Lovibond Red (LovR), Lovibond Yellow (LovY), Haze (%), Transmittance (%), Clarity |
