Color Difference Meter
Filter
Showing 421–450 of 562 results
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-3600A |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere (SCI & SCE simultaneous) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360 nm – 740 nm |
| Wavelength Interval | 10 nm |
| FWHM | ~10 nm |
| Reflectance Measurement Range | 0–200% (0.01% resolution) |
| Repeatability | ΔE*ab ≤ 0.02 (after white calibration, 30 measurements at 10 s intervals) |
| Inter-instrument Agreement | ΔE*ab ≤ 0.15 (LAV/SCI, BCRA Series II avg.) |
| Temperature Drift | ≤ 0.05 ΔE*ab /°C |
| Measurement Apertures | Φ25.4 mm (LAV), Φ8 mm (MAV), Φ4 mm (SAV), all interchangeable |
| Transmission Geometry | d/0° (diffuse illumination, normal detection) |
| Transmission Aperture | ~Φ17 mm |
| Sample Dimensions (Transmission) | ≤133 mm width, ≤50 mm thickness |
| Interface | USB 1.1 |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Operating Environment | 13–33 °C, ≤80% RH (non-condensing) |
| Dimensions (CM-3600A) | 244 × 205 × 378 mm |
| Weight | 11.5 kg |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-3600d |
| Illumination/Viewing Geometry | d/8° (diffuse illumination, 8° viewing) for reflectance |
| Compliance | CIE No. 15, ISO 7724-1, ASTM E1164, DIN 5033-7, JIS Z8722 Condition C |
| Spectral Range | 360–740 nm |
| Spectral Interval | 10 nm |
| FWHM | ~10 nm |
| Detector | Dual 40-element silicon photodiode arrays |
| Grating Type | Planar diffraction grating |
| Integrating Sphere Diameter | Φ152 mm |
| Light Source | Four pulsed xenon lamps |
| Measurement Time | ~1.5 s (to data output) |
| Apertures | LAV (Φ25.4 mm), MAV (Φ8 mm), SAV (Φ4 mm) for reflectance |
| Repeatability | ΔE*ab ≤ 0.02 (standard deviation), spectral reflectance SD ≤ 0.1% |
| Instrumental Error | ΔE*ab ≤ 0.15 (LAV/SCI, BCRA Series II tile average) |
| UV Control | Digital UV adjustment with selectable 400 nm / 420 nm cutoff filters |
| Transmittance Chamber | 133 mm (W) × ~50 mm (D), ~17 mm aperture |
| Interface | RS-232C (D-sub 9-pin female) |
| Power | AC 120 V / 230 V, 50 / 60 Hz (via included adapter) |
| Operating Environment | 13–33 °C, ≤80% RH (non-condensing) |
| Dimensions (W×H×D) | 244 × 208 × 378 mm |
| Weight | 12 kg |
| Standard Accessories | White calibration tile, aperture masks (Φ4/Φ8/Φ25.4 mm), zero calibration box, AC adapter, dust cover, accessory case, driver software, RS-232C cable (2 m) |
| Brand | Konica Minolta |
|---|---|
| Origin | Shanghai, China |
| Model | CM-3610A |
| Product Type | Benchtop Spectrophotometer |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Quad-pulse xenon lamp |
| Spectral Range | 360 nm – 740 nm |
| Spectral Interval | 10 nm |
| Repeatability (after white calibration) | spectral reflectance SD ≤ 0.1%, ΔE*ab SD ≤ 0.02 |
| Inter-instrument Agreement | ΔE*ab ≤ 0.15 (LAV/SCI, BCRA Series II average at 23°C) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-36dG / CM-36dGV / CM-36d |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed xenon lamp |
| Spectral Range | 360–740 nm |
| Repeatability | ΔE*ab ≤ 0.02 (standard deviation) |
| Inter-instrument Agreement | ΔE*ab ≤ 0.12 (LAV, SCI) |
| UV Control | Digital dual-xenon UV calibration (400 nm / 420 nm cutoff simulation) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-36dG |
| Type | Benchtop Spectrophotometer |
| Optical Geometry | di:8°/de:8° (Diffuse Illumination / 8° Viewing, SCI/SCE Switchable) & di:0°/de:0° (Diffuse Illumination / 0° Viewing for Transmission) |
| Integrating Sphere Diameter | Ø152 mm |
| Spectral Separation | Diffraction Grating |
| Wavelength Range | 360–740 nm |
| Wavelength Interval | 10 nm |
| FWHM | ~10 nm |
| Reflectance Range | 0–200% (0.01% resolution) |
| Illuminant | Triple Pulsed Xenon Lamps (2 with UV-cut filters) + 1 Pulsed Xenon Lamp |
| Aperture Options | LAV (Ø30 mm/Ø25.4 mm), LMAV (Ø20 mm/Ø16 mm), MAV (Ø11 mm/Ø8 mm), SAV (Ø7 mm/Ø4 mm), Transmittance LAV/MAV/SAV |
| Repeatability | ΔE*ab ≤ 0.02 (SCI), ΔE*ab ≤ 0.03 (SCE) |
| Inter-instrument Agreement | ΔE*ab ≤ 0.12 (LAV/SCI, BCRA Series II avg.) |
| UV Control | Digital UV Adjustment (0–100%, no mechanical filter movement), 400 nm & 420 nm UV-cut filters |
| Gloss Measurement | 60° geometry, White LED source, Silicon Photodiode sensor, Range: 0–200 GU (0.01 GU resolution), MAV spot: 10×8 mm elliptical, SAV spot: Ø3 mm |
| Gloss Repeatability | ±0.1 GU (0–10 GU), ±0.2 GU (10–100 GU), ±0.2% (100–200 GU) |
| Gloss Inter-instrument Agreement | ±0.2 GU (0–10 GU), ±0.5 GU (10–100 GU, MAV) |
| Compliance | CIE No.15:2004, ISO 7724-1, ASTM E1164, DIN 5033-7, JIS Z 8722 (Condition C/G), JIS Z 8741, ISO 2813, ISO 7668, ASTM D523-08, ASTM D2457-13, DIN 67530 |
| Measurement Time | ~2.5 s (SCI or SCE), ~3.5 s (SCI+SCE), ~4.0 s (SCI+SCE+Gloss), ~2.5 s (Transmission) |
| Wavelength Analysis & Adjustment (WAA) | Optional licensed feature |
| Interface | USB 2.0 |
| Auto Aperture Detection | Yes |
| Operating Environment | 13–33°C, ≤80% RH (non-condensing) |
| Dimensions (W×H×D) | 248×250×498 mm |
| Weight | ~8.4 kg |
| Standard Accessories | White Cal. Tile, Aperture Masks (LAV/LMAV/MAV/SAV), Gloss Cal. Tile, Zero Cal. Box, USB Cable (2 m), AC Adapter, Dust Cover, Accessory Case, Cleaning Cloth |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-3700A |
| Instrument Type | Desktop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360 nm – 740 nm |
| Repeatability | ΔE*ab ≤ 0.005 (std. dev.) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-3700A Plus |
| Type | Benchtop Spectrophotometer |
| Illumination/Observation | di:8°/de:8° (Diffuse Illumination / 8° Viewing) for Reflectance |
| di | 0°/de:0° for Transmittance |
| Compliance | CIE No.15:2004, ISO 7724-1, ASTM E1164, DIN 5033-7, JIS Z 8722 (Conditions c & g) |
| Integrating Sphere Diameter | ∅152 mm |
| Detector | Silicon Photodiode Array (38 channels) |
| Dispersion Element | Diffraction Grating |
| Wavelength Range | 360–740 nm |
| Interval | 10 nm |
| FWHM | ~14 nm (avg.) |
| Reflectance Range | 0–200% (0.001% resolution) |
| Light Source | Pulsed Xenon Lamp |
| Measurement Apertures | SAV (3×5 mm / 5×7 mm), MAV (∅8 / ∅11 mm), LMAV (∅16 / ∅20 mm), LAV (∅25.4 / ∅28 mm) |
| Transmittance Aperture | ∅20 / ∅25 mm |
| Repeatability (White) | ΔE*ab ≤ 0.005, Spectral Reflectance SD ≤ 0.05% |
| (Black) | ΔE*ab ≤ 0.02, Spectral Reflectance SD ≤ 0.02% |
| Inter-instrument Agreement | ΔE*ab ≤ 0.08 (BCRA Series II, 12 tiles, LAV/SCI) |
| UV Adjustment | 0.0–100.0% (1000-step, software-controlled) |
| Sample Temperature Measurement Accuracy | ±0.5°C (LAV), ±0.8°C (MAV/LMAV), ±1.2°C (SAV) |
| Measurement Time | ~2 s (SCI/SCE), ~4.5 s (with temp.), ~5 s (SCI+SCE), ~2 s (Transmittance) |
| Transmittance Chamber Max Thickness | ~50 mm |
| Dimensions (H×W×D) | 307 × 271 × 600 mm |
| Weight | ~20.0 kg |
| Operating Environment | 13–33°C, ≤80% RH (non-condensing) |
| Interface | USB 2.0 |
| Power | Dedicated AC Adapter |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-3700d |
| Product Type | Spectrophotometer |
| Instrument Type | Desktop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360 nm – 740 nm |
| Repeatability | ΔE*ab standard deviation ≤ 0.005 |
| Brand | Konica Minolta |
|---|---|
| Origin | Shanghai, China |
| Model | CM-3700d |
| Illumination/Viewing Geometry | d/8° (diffuse illumination / 8° viewing), switchable SCI (Specular Component Included) / SCE (Specular Component Excluded) |
| Transmission Mode | d/0° |
| Wavelength Range | 360–740 nm |
| Wavelength Interval | 10 nm |
| FWHM | ~14 nm (average) |
| Photometric Range | 0–200% |
| Resolution | 0.001% |
| Light Source | Pulsed Xenon Arc Lamp |
| Measurement Time | 0.6–0.8 s (to data output) |
| Apertures (Reflectance) | LAV (Φ28 mm illum. / Φ25.4 mm meas.), MAV (Φ11 mm / Φ8 mm), SAV (5×7 mm / 3×5 mm) |
| Aperture (Transmittance) | ~Φ20 mm |
| Repeatability (White Tile, 30 measurements @ 10 s intervals) | ΔE*ad ≤ 0.005 |
| Repeatability (Black Tile, BCRA Series II, 1% R) | ΔE*ad ≤ 0.05 |
| Instrument Error (LAV, BCRA Series II 12-tile avg.) | ΔE*ad ≤ 0.08 (typical) |
| Temperature Drift | Spectral Reflectance ±0.10%/°C |
| UV Adjustment | PC-controlled, continuously variable (1000-step) |
| Sample Thickness Limit (Transmittance) | < 50 mm |
| Interface | RS-232C (1200–9600 bps) |
| Power Supply | AC 100/120/230 V, 50/60 Hz |
| Operating Environment | 13–33 °C, ≤80% RH (non-condensing) |
| Storage Environment | 0–40 °C, ≤80% RH (non-condensing) |
| Dimensions (W×H×D) | 271×259×500 mm |
| Weight | 18 kg |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Instrument Type | Benchtop |
| Measurement Principle | Diffuse Illumination / 8° Viewing (d/8°) for Reflectance |
| Compliance | CIE No.15, ISO 7724-1, ASTM E1164, DIN 5033-7, JIS Z 8722 (Condition C) |
| Spectral Range | 360–740 nm |
| Spectral Interval | 10 nm |
| FWHM | ~10 nm |
| Integrating Sphere Diameter | Ø152 mm |
| Detector | Dual-row 40-element silicon photodiode array |
| Grating | Plane diffraction grating |
| Light Source | Pulsed xenon lamp with UV filter |
| Measurement Time | ~1 s (data output) |
| Minimum interval | ~3 s |
| Repeatability | ΔE*ab ≤ 0.04 (after white calibration, 30 measurements at 10 s intervals) |
| Inter-instrument Agreement | ΔE*ab ≤ 0.15 (typical, BCRA Series II, 23°C) |
| Reflectance Range | 0–170% |
| Resolution | 0.01% |
| Illumination/Aperture Options | LAV (Ø30/Ø36 mm), MAV (Ø8/Ø11 mm, optional), SAV (Ø3/Ø6 mm, optional) |
| Transmittance Aperture | Ø20 mm |
| Transmittance Chamber Max Thickness | 60 mm |
| Display | 5.7″ TFT color LCD |
| Languages | English, Simplified Chinese, Japanese, German, French, Italian, Spanish |
| Observer Angles | 2° and 10° standard observers |
| Illuminants | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65 (dual-illuminant display supported) |
| Color Spaces | CIE L*a*b*, L*C*h*, Hunter Lab, Yxy, XYZ, Munsell (color difference only in non-Munsell spaces) |
| Color Difference Formulas | ΔE*ab (CIE 1976), ΔE94 (CIE 1994), ΔE00 (CIE 2000), ΔE(Hunter), CMC (l:c) |
| Indices | MI, WI (ASTM E313-73/96), YI (ASTM E313-73/96, ASTM D1925), ISO Brightness, B (ASTM E313-73), Gardner, Iodine, Hazen/APHA, EP, USP |
| Tolerance Setting | For color values (except Munsell), color differences, or reflectance indices |
| Data Storage | 4,000 sample measurements + 1,000 standards internally |
| Interface | USB 1.1 (PC & USB memory), RS-232C (printer) |
| Power | AC 100–240 V, 50/60 Hz (with supplied adapter) |
| Dimensions (closed) | 385 × 192 × 261 mm (W × H × D) |
| (open) | 475 × 192 × 261 mm |
| Weight | ~5.8 kg |
| Operating Environment | 13–33°C, ≤80% RH (non-condensing at ≤35°C) |
| Storage Environment | 0–40°C, ≤80% RH (non-condensing at ≤35°C) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere (SCI/SCE switchable) |
| Illuminants | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65 |
| Spectral Range | 360 nm – 740 nm |
| Wavelength Interval | 10 nm |
| FWHM | ~10 nm |
| Reflectance Measurement Range | 0–175% |
| Transmittance Measurement Range | 0–175% |
| Repeatability | ΔE*ab ≤ 0.04 (after white calibration, 30 measurements at 10 s intervals) |
| Inter-instrument Agreement | ΔE*ab ≤ 0.15 (typical, BCRA Series II, 23°C) |
| Aperture Options (Reflectance) | LAV Ø30 mm / Ø36 mm, MAV (optional) Ø8 mm / Ø11 mm, SAV (optional) Ø3 mm / Ø6 mm |
| Transmittance Aperture | Ø20 mm |
| Transmittance Chamber Max Thickness | 60 mm |
| Chamber Width | Unlimited |
| Measurement Time | ~1 s (data output) |
| Minimum Interval | ~3 s |
| Display | 5.7" TFT color LCD |
| Languages | English, Simplified Chinese, Japanese, German, French, Italian, Spanish |
| Compliance | CIE No. 15, ISO 7724-1, ASTM E1164, DIN 5033-7, JIS Z 8722 (Condition c) |
| Interface | USB 1.1, RS-232C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (closed) | 385 × 192 × 261 mm (W × H × D) |
| Weight | ~5.8 kg |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Instrument Type | Desktop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360 nm – 740 nm |
| Spectral Reflectance Repeatability | ≤ 0.1% standard deviation (400–740 nm) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-512m3 |
| Illumination/Reception Geometry | 25°/0°, 45°/0°, 75°/0° (annular multi-angle) |
| Wavelength Range | 400–700 nm |
| Wavelength Interval | 20 nm |
| Reflectance Range | 25°: 0–300% |
| 45°/75° | 0–200% |
| Photometric Resolution | 0.01% |
| Light Source | Pulsed Xenon Arc Lamp |
| Minimum Measurement Interval | 7 s (with white calibration tile, at 23°C) |
| Repeatability | ΔE*ab ≤ 0.05 (n=30, 10-s interval), Spectral Reflectance SD ≤ 0.30% |
| Aperture | Measuring Ø12 mm / Illuminating Ø20 mm |
| Temperature Sensing | Thermopile detector (8–13 µm), Range: −10 to +80°C (±2.5°C accuracy at 0–50°C, ε=0.93) |
| Display | 128×56-dot reflective LCD (21 chars × 7 lines) |
| Interface | RS-232C (D-sub 9-pin female) |
| Power | 4× AA alkaline batteries or optional AC adapter |
| Dimensions (W×H×D) | 115×257×164 mm |
| Weight | ≈1.4 kg (battery-free) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-512m3 |
| Type | Portable Spectrophotometer |
| Optical Geometry | d/8° integrating sphere with multi-angle annular illumination (25°, 45°, 75°) / 0° vertical reception |
| Light Source | Triple pulsed xenon lamp |
| Spectral Range | 400–700 nm |
| Spectral Interval | 20 nm |
| Reflectance Range | 25°: 0–300% |
| 45° & 75° | 0–200% |
| Repeatability | ΔE*ab ≤ 0.05 (after white calibration, 30 measurements at 10 s intervals) |
| Measurement Aperture | Φ12 mm / Φ20 mm |
| Minimum Measurement Interval | 3 s (at 23°C on white calibration tile) |
| Display | L*a*b*, L*C*h*, ΔE*ab, ΔE00, CMC (l:c), FF value, line chart |
| Observer | 2° and 10° standard observer |
| Illuminants | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 |
| Memory Capacity | 440 data sets (standards + samples) |
| Interface | RS-232C, IrDA |
| Power | 4 × AA alkaline or Ni-MH batteries / AC adapter |
| Operating Temp. | 0–40°C, ≤85% RH (non-condensing) |
| Dimensions | 164 × 115 × 257 mm |
| Weight | ~1.4 kg (without batteries) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.04 (average, CIE Lab) |
| Display | Color LCD |
| Connectivity | Bluetooth® v4.0 + USB 2.0 |
| Aperture Options | Ø8 mm (standard), Ø3 mm (not supported on CM-600d) |
| Compliance | ISO 7724-1, ISO 11664-4 (CIE 1976 L*a*b*), ASTM E308, JIS Z 8722 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360 nm – 740 nm |
| Repeatability | ΔE*ab ≤ 0.005 (std. dev.), Reflectance/Transmittance std. dev. ≤ 0.05% |
| Brand | Konica Minolta |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Spectrophotometric Colorimeter |
| Instrument Type | Portable |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Tungsten Halogen Lamp |
| Spectral Range | 360–750 nm |
| Repeatability | ΔE*ab ≤ 0.07 (for white calibration tile, 10 measurements) |
| Aperture Options | 8 mm and 3 mm (CM-700D only) |
| Display | Full-color LCD |
| Connectivity | Bluetooth® v4.0 + USB 2.0 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-700d/600d |
| Type | Portable Spectrophotometric Colorimeter |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | Spectral Reflectance ≤ 0.1% std. dev. |
| Aperture Options | Φ8 mm and Φ3 mm (CM-700d only) |
| Connectivity | Bluetooth® v4.0 + USB 2.0 |
| Display | Full-color TFT LCD |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-700d / CM-600d |
| Illumination/Viewing Geometry | di:8°, de:8° (Diffuse illumination / 8° viewing) |
| Integrating Sphere Diameter | Φ40 mm |
| Detector | Silicon photodiode array (dual 36-element) |
| Spectral Dispersion | Diffraction grating |
| Wavelength Range | 400–700 nm |
| Measurement Interval | 10 nm |
| FWHM | ~10 nm |
| Light Source | Pulsed xenon lamp with UV-cut filter |
| Measurement Time | Approx. 1 sec |
| Repeatability | Spectral reflectance SD ≤0.1% |
| Instrument Error | ΔE*ab ≤0.2 (MAV/SCI, vs. BCRA Series II 12-color tile set, 23°C) |
| Apertures | MAV: Φ8 mm / Φ11 mm |
| SAV | Φ3 mm / Φ6 mm (CM-700d only) |
| Display | 2.36″ TFT color LCD |
| Interfaces | USB 1.1, Bluetooth® v1.2 (Class 1) |
| Color Spaces | CIE L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell (ΔE only for non-Munsell spaces) |
| Color Difference Formulas | ΔE*ab (CIE 1976), ΔE94 (CIE 1994), ΔE00 (CIE 2000), CMC (l:c) |
| Whiteness/Yellowness Indices | WI (ASTM E313), YI (ASTM E313-73 / D1925), ISO Brightness |
| Gloss | 8° gloss measurement capability |
| Data Storage | 4,000 sample measurements + 1,000 standard references |
| Power | 4 × AA alkaline or Ni-MH rechargeable (2300 mAh) |
| Dimensions | 73 (W) × 211.5 (H) × 107 (D) mm |
| Weight | ~550 g (excl. white calibration tile and batteries) |
| Operating Environment | 5–35°C, RH ≤80% (non-condensing) |
| Storage Environment | 0–45°C, RH ≤80% (non-condensing) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-M6 |
| Instrument Type | Portable |
| Optical Configuration | Multi-Angle Geometry |
| Light Source | High-CRI White LED |
| Spectral Range | 400–700 nm |
| Repeatability | Chromaticity Standard Deviation ≤ ΔE*ab 0.05 |
| Measurement Aperture | Ø6 mm |
| Illumination Angle | 45° |
| Viewing Angles | –15°, 15°, 25°, 45°, 75°, 110° |
| Optical Architecture | Mirror-Symmetric Dual Illumination/Reception System |
| Compliance | Designed for ISO 7724, ASTM E308, CIE No. 15, JIS Z 8722 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-M6 |
| Product Type | Multi-Angle Spectrophotometer |
| Instrument Form Factor | Portable (Handheld) |
| Measurement Geometry | 45° illumination / -15°, 15°, 25°, 45°, 75°, 110° multi-angle specular-reception |
| Illumination Area | 17 × 12 mm |
| Measurement Aperture Dimensions (varies by angle) | 45°: 6 × 6 mm (circular φ6 mm) |
| 25° | 6.4 × 6 mm |
| 15° & 75° | 7 × 6 mm |
| -15° & 110° | 14 × 6 mm (elliptical, reduced effective area in deep/small-bore applications) |
| Optical System | Mirror-Symmetric Dual-Optical-Path Architecture |
| Compliance | ISO 7724, ISO/CIE 11664, ASTM E308, JIS Z 8722 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-10 |
| Illumination/Viewing Geometry | 8°/diffuse (d) |
| Measurement Area | Ø8 mm |
| Display Modes | Δ(L*a*b*) & ΔE*ab, or Δ(L*C*H*) & ΔE*ab |
| Standard Observer | CIE 10° |
| Illuminant | CIE D65 |
| Repeatability | σ(ΔE*ab) ≤ 0.1 (measured on white calibration tile, average of multiple readings) |
| Measurement Interval | Approx. 1 second |
| Power Supply | 4 × AA batteries or optional AC adapter AC-A12 |
| Operating Temperature | 0–40 °C, RH < 85% (non-condensing) |
| Standard Accessories | Soft case CR-A68, protective cap CR-A72, wrist strap CR-A73, 4 × AA batteries |
| Optional Accessories | AC adapter AC-A12, printer cable CR-A75 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-10 Plus |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere (with specular component included) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360 nm – 750 nm |
| Repeatability | ΔE*ab ≤ 0.1 (standard deviation, measured 30 times on white calibration tile at 10 s intervals) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-10 Plus |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere (including specular component, SCI) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | L*: 1–100 |
| Repeatability | Standard deviation of ΔE*ab ≤ 0.1 |
| Measurement Aperture | Ø8 mm |
| Measurement Time | ~1 second |
| Observer Angle | 10° |
| Illuminant | D65 |
| Color Spaces | CIE L*a*b*, L*C*H*, CIE 1976 ΔE*ab |
| Compliance | DIN 5033-7, JIS Z 8722 (Condition d), ISO 7724-1, CIE No. 15, ASTM E1164 |
| Data Storage | Up to 1,000 measurements (reference + sample) |
| Interface | USB 2.0 |
| Power | 4 × AA alkaline or Ni-MH batteries |
| Dimensions | 66 × 158 × 85 mm |
| Weight | 420 g (without batteries) |
| Operating Environment | 0–40°C, ≤85% RH (non-condensing at 35°C) |
| Storage Environment | −20–40°C, ≤85% RH (non-condensing at 35°C) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-10 Plus |
| Instrument Type | Portable Spectrophotometric Colorimeter |
| Illumination/Viewing Geometry | 8°/d (including specular component) |
| Observer Angle | 10° |
| Illuminant | D65 |
| Measurement Aperture | Ø8 mm (MAV), optional Ø5 mm |
| Repeatability | σΔE*ab ≤ 0.1 (measured 30× on white calibration tile at 10 s intervals) |
| Measurement Time | ~1 s |
| Data Storage Capacity | Up to 1,000 sets (standard + sample data) |
| Display | ΔL*a*b*, ΔL*C*H*, ΔE*ab (CIE 1976) |
| Compliance | DIN 5033-7, JIS Z 8722 Condition d, ISO 7724-1, CIE No. 15, ASTM E1164 |
| Interface | USB 2.0 |
| Power | 4× AA alkaline/Ni-MH batteries, USB bus power, or optional AC adapter |
| Dimensions | 66 × 158 × 85 mm |
| Weight | 420 g (body only) |
| Operating Environment | 0–40°C, ≤85% RH (non-condensing at 35°C) |
| Storage Environment | −20–40°C, ≤85% RH |
| Supported Languages | English, Japanese, Simplified Chinese |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Illuminant | CIE D65 |
| Observer Angle | 10° |
| L* Range | 10–100 |
| Repeatability | ΔE*ab ≤ 0.1 (std. dev., white tile average) |
| Brand | Konica Minolta |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CR-10 |
| Price | USD 2,250 (approx.) |
| Instrument Type | Portable Spectrophotometric Colorimeter |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Tungsten Halogen Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.1 (for white tile, 10 measurements) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-20 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere (including specular component) |
| Light Source | Pulsed xenon lamp |
| Spectral Range | 360 nm to 750 nm |
| Repeatability | ΔE*ab ≤ 0.1 (std. dev., measured 30 times on white calibration tile at 10-sec intervals) |
| Aperture | Ø8 mm |
| Data Storage | 1,000 measurement sets |
| Measurement Time | ~1 second |
| Observer Angle | 10° |
| Illuminant | D65 |
| Supported Color Spaces | CIE L*a*b*, L*C*h, Yxy, XYZ, Munsell (D65) |
| Color Indices | WI (CIE/ASTM E313-96), Tint (CIE/ASTM E313-96), YI (ASTM E313-96) |
| Compliance | DIN 5033-7, JIS Z 8722 (Condition d), ISO 7724-1, CIE No. 15, ASTM E1164 |
| Power Supply | 4 × AA alkaline/Ni-MH batteries, USB bus power, or optional AC adapter |
| Dimensions | 66 mm (W) × 159.5 mm (H) × 85 mm (D) |
| Weight | 420 g |
| Operating Environment | 0–40°C, ≤85% RH (non-condensing at 35°C) |
| Storage Environment | −20–40°C, ≤85% RH (non-condensing at 35°C) |
| Interface | USB 2.0 |
| Display | Color data, mean values (up to 999 readings), pass/fail indicators |
| Language Support | English, Japanese |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-20 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Repeatability | ΔE*ab ≤ 0.1 (standard deviation) |
| Data Storage | Up to 1,000 measurement sets (including reference) |
| Color Spaces | CIE L*a*b*, L*C*h, Yxy, XYZ, Munsell, WI (CIE/ASTM E313-96), Tint (CIE/ASTM E313-96), YI (ASTM E313-96) |
| Compliance | ASTM E313, ISO 7724, JIS Z 8722, CIE No. 15 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CR-20 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere (with specular component included) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360–750 nm |
| Repeatability | ΔE*ab ≤ 0.1 (std. dev., 30 measurements on white calibration tile at 10-sec intervals) |
| Aperture | Ø8 mm |
| Observer Angle | 10° |
| Illuminant | D65 |
| Display | Backlit LCD |
| Data Storage | Up to 1,000 measurement sets (including reference) |
| Interface | USB 2.0 |
| Power | 4 × AA alkaline/Ni-MH batteries, USB bus power, or AC adapter (optional) |
| Dimensions | 66 × 159.5 × 85 mm |
| Weight | 420 g (without batteries) |
| Compliance | DIN 5033-7, JIS Z 8722 Condition d, ISO 7724-1, CIE No. 15, ASTM E1164 |