| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 35425-05 |
| Price Range | USD 70–700 (FOB) |
| Measured Parameters | pH, Conductivity, TDS, Salinity, Temperature |
| Portability | Handheld / Pen-style |
| Conductivity Range | 0–200 µS/cm |
| TDS Range | 0–100 ppm |
| Resistivity Range | 0–100 kΩ·cm |
| Salinity Range | 0–100 ppm (NaCl equivalent) |
| Temperature Range | 10–110 °C |
| Accuracy | ±0.2% of reading |
| Minimum Resolution | 0.001 unit (context-dependent per parameter) |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | AB33EC-F |
| Measurement Type | Single-parameter (Conductivity/Resistivity/Temperature) |
| Form Factor | Benchtop |
| Intended Use | Laboratory |
| Conductivity Range | 0.001 μS/cm – 1000 mS/cm |
| Resistivity Range | 1 Ω to 100 MΩ |
| Temperature Range | 5°C – 40°C |
| Accuracy | ±0.5 % of reading |
| Minimum Conductivity Resolution | 0.001 μS/cm |
| Resistivity Resolution | 0.01 Ω |
| Temperature Resolution | 0.3 °C |
| Display | Backlit LCD with single-line dot-matrix |
| Power Supply | AC adapter (included) |
| Dimensions (L×H×W) | 210 mm × 51 mm × 142 mm |
| Net Weight | 0.5 kg |
| Operating Environment | 5°C – 40°C, ≤80% RH (non-condensing) |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | AB33EC-F ZH (formerly STARTER 3100C/F) |
| Form Factor | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0.001 µS/cm – 1000 mS/cm |
| TDS Range | 0.1 mg/L – 200 g/L |
| Resistivity Range | 1 Ω·cm – 100 MΩ·cm |
| Salinity Range | 0–100 PSU |
| Temperature Range | −5 °C to 110 °C |
| Accuracy | ±0.5% of reading ±2 digits |
| Minimum Conductivity Resolution | 0.001 µS/cm |
| Temperature Resolution | 0.3 °C |
| Display | 6.5-inch backlit dot-matrix LCD |
| Dimensions (L×H×W) | 210 mm × 51 mm × 142 mm |
| Net Weight | 0.5 kg |
| Power Supply | AC adapter (included) |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | AB23EC-B |
| Measurement Parameters | Conductivity, TDS, Salinity, Temperature |
| Portability | Benchtop |
| Conductivity Range | 0.0 μS/cm – 199.9 mS/cm |
| TDS Range | 0.1 mg/L – 199.9 g/L |
| Salinity Range | 0.0 – 99.9 PSU |
| Temperature Range | 0.0 – 100.0 °C |
| Accuracy | ±1% of reading ±3 least significant digits |
| Minimum Resolution | 0.01 μS/cm (auto-ranging) |
| Data Storage | 99 readings |
| Display | 5-inch segmented backlit LCD |
| Housing | ABS plastic |
| Weight | 0.38 kg |
| Dimensions (H × L × W) | 51 mm × 210 mm × 142 mm |
| Power Supply | AC adapter |
| Electrode | Not included |
| Temperature Compensation | Automatic and manual |
| Calibration | Auto-buffer recognition, manual endpoint control |
| Compliance | Designed for general laboratory use per ISO 5725 (accuracy verification), compatible with GLP data integrity practices |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | AB23EC-F |
| Measurement Parameters | Conductivity, TDS, Salinity, Temperature |
| Portability | Benchtop |
| Conductivity Range | 0.0 μS/cm – 199.9 mS/cm |
| TDS Range | 0.1 mg/L – 199.9 g/L |
| Salinity Range | 0.0 – 99.9 PSU |
| Temperature Range | 0.0 – 100.0 °C |
| Accuracy | ±1% of reading ±3 least significant digits |
| Minimum Resolution | 0.01 μS/cm (conductivity), auto-ranging |
| Data Storage | 99 readings |
| Temperature Compensation | Automatic and manual |
| Display | 5-inch segmented backlit LCD |
| Housing | ABS plastic |
| Weight | 0.38 kg |
| Dimensions (H × L × W) | 51 mm × 210 mm × 142 mm |
| Power Supply | AC adapter included |
| Electrode | Not included |
| Compliance | Designed for general laboratory use in accordance with ISO 7888 and ASTM D1125 guidelines for conductivity and TDS measurement |
| Brand | OHAUS |
|---|---|
| Model | AB33EC-F |
| Type | Benchtop Conductivity/TDS/Salinity/Resistivity/Temperature Meter |
| Origin | Jiangsu, China |
| Manufacturer | OHAUS (China) Co., Ltd. |
| Measurement Parameters | Conductivity (0.001 μS/cm – 1000 mS/cm), TDS (0.01 mg/L min, auto-ranging), Resistivity (1 – 100 MΩ·cm), Salinity (0 – 100 PSU), Temperature (−5.0 to 110.0 °C) |
| Accuracy | ±0.5% of reading ±2 digits |
| Minimum Resolution | 0.001 μS/cm (conductivity), auto-ranging |
| Display | 6.5-inch backlit segmented & dot-matrix LCD with capacitive touch keys |
| Data Storage | 1000 measurement records |
| Calibration Management | i-Steward intelligent calibration monitoring with expiry alert |
| Connectivity | RS232 and USB |
| Power | AC adapter included |
| Operating Environment | 5–40 °C, ≤80% RH (non-condensing) |
| Dimensions (H×L×W) | 51 × 210 × 142 mm |
| Net Weight | 0.5 kg |
| Housing | ABS enclosure with integrated electrode stand |
| Electrode | Not included |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | AB33EC-B |
| Detection Parameters | Single-parameter (Conductivity/TDS/Resistivity/Salinity/Temperature) |
| Form Factor | Benchtop |
| Conductivity Range | 0.001 μS/cm – 1000 mS/cm |
| TDS Range | 0.01 mg/L (auto-ranging) |
| Resistivity Range | 1 – 100 MΩ·cm |
| Salinity Range | 0 – 100 psu |
| Temperature Range | −5.0 to 110.0 °C |
| Accuracy | ±0.5% of reading ±2 digits |
| Minimum Resolution | 0.001 μS/cm |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | OHAUS Water Analysis Conductivity Standard Solutions |
| Pricing | Available Upon Request |
| Concentration Options | 84 µS/cm, 500 µS/cm, 1413 µS/cm, 12.88 mS/cm |
| Volume | 250 mL per bottle |
| Format | Dual-pack (two identical vials per SKU) |
| Certifications | Traceable to NIM (National Institute of Metrology, China) |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Line | ST Series |
| Portability | Pen-style |
| Measured Parameters | pH, ORP, Conductivity, TDS, Salinity, Dissolved Oxygen (DO), Temperature (ST20 only) |
| Salinity Range | 0–10 ppt |
| Accuracy | ±1.5% FS |
| Minimum Resolution | 0.1 ppt |
| Ingress Protection | IP67 |
| Power Source | Replaceable Coin Cell Battery |
| Auto-off | After 6 minutes of inactivity |
| Electrode Replaceability | Yes |
| Warranty & Compliance | Designed for field and educational use |
| Brand | OHAUS |
|---|---|
| Model | STARTER 300C |
| Type | Portable Multiparameter Electrochemical Analyzer |
| Conductivity Range | 0.00 µS/cm to 199.9 mS/cm |
| TDS Range | 0.1 mg/L to 199.9 g/L |
| Resistivity Range | 0 to 100 MΩ·cm |
| Salinity Range | 0 to 100 ppt |
| Temperature Range | −5 °C to 105 °C |
| pH Accuracy | ±0.01 pH |
| pH Resolution | 0.01 pH |
| Temp. Accuracy | ±0.3 °C (calibrated) |
| Temp. Compensation | Linear, adjustable from 0.00%/°C to 100.00%/°C |
| Reference Temp. | 20 °C or 25 °C |
| Calibration | 1-point pH |
| Data Storage | 30 measurement records |
| Power | 4 × AAA batteries (>250 h battery life) |
| Dimensions | 90 W × 170 D × 35 H mm |
| Weight | 0.16 kg (without batteries) |
| Display | LCD with icon-based status indicators |
| Enclosure | ABS housing |
| Ingress Protection | IP54 |
| Electrode Interface | Mini-DIN connector for integrated temperature compensation |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | STARTER 300C (ST300C) |
| Portability | Portable |
| Application Environment | Laboratory |
| Conductivity Range | 0.00 µS/cm to 199.9 mS/cm |
| TDS Range | 0.1 mg/L to 199.9 g/L |
| Temperature Range | 0 °C to 100 °C |
| Accuracy | ±0.5% F.S. |
| Minimum Conductivity Resolution | 0.01 µS/cm |
| Temperature Resolution | 0.1 °C |
| Power Supply | 4 × AAA batteries |
| Battery Life | Up to 250 hours |
| Dimensions (H×L×W) | 33 mm × 170 mm × 90 mm |
| Net Weight | 0.16 kg |
| Auto-Off Delay | 10 minutes |
| Temperature Compensation | Automatic, adjustable β coefficient (0.0–10.0 %/°C) |
| Sensor Type | Integrated 30 kΩ NTC thermistor |
| Operating Environment | 5 °C to 40 °C, ≤80% RH (non-condensing) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Orion Star A |
| Pricing | Available Upon Request |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 600 |
| Portability | Portable |
| Conductivity Range | 0–199.9 mS/cm |
| Detection Parameter | Single-parameter (Conductivity & Temperature) |
| Electrode Constants | K = 0.1, 1.0, 10.0 (user-selectable via keypad) |
| Calibration Points | Up to 5 points (1 per range) |
| Temperature Range | 0–80.0 °C |
| Resolution | 0.1 °C (temperature), 0.05% FS (conductivity) |
| Accuracy | ±1% FS + 1 LSD (conductivity), ±0.5 °C (temperature) |
| Temp. Compensation | Automatic or manual (0–80 °C), adjustable temperature coefficient (0.0–3.0 %/°C), reference temp. selectable (20.0–25.0 °C) |
| Display | Monochrome LCD |
| Power | 4 × AAA alkaline batteries (>100 h operation) |
| Dimensions | 140 × 70 × 35 mm |
| Weight | 200 g |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 600 |
| Portability | Portable |
| TDS Range | 0–99.9 g/L |
| Resolution | 0.01/0.1/1 mg/L and 0.01/0.1/1 g/L |
| Accuracy | ±1% FS |
| Temperature Range | 0–100.0 °C |
| Temp. Compensation | Automatic or Manual (0–80 °C) |
| Cell Constant Options | 0.1, 1.0, 10.0 cm⁻¹ |
| TDS Conversion Factor | 0.40–1.00 (default 0.67) |
| Calibration | Up to 5-point manual per range |
| Display | Single-line LCD |
| Power | 4 × AAA alkaline batteries (>100 h life) |
| Dimensions | 140 × 70 × 35 mm |
| Weight | 200 g |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 800 |
| Portability | Portable |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–20 g/L |
| Temperature Range | −10 to 110 °C |
| pH Range | −2.00 to 16.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Conductivity Resolution | up to 0.01 µS/cm |
| Conductivity Accuracy | ±1% FS |
| TDS Resolution | up to 0.01 mg/L |
| TDS Accuracy | ±1% FS |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 6-point pH (NIST & USA buffer standards), 1-point per conductivity/TDS range, manual or automatic |
| Data Storage | 500 readings |
| Power | 2 × AA alkaline batteries (>100 h life) |
| Dimensions | 200 × 93 × 57 mm |
| Weight | 500 g |
| Interface | USB and RS-232 |
| Auto-off | After 17 min idle |
| Display | Single-line LCD |
| Brand | Pinnacle |
|---|---|
| Model | CD-30 |
| Type | Pocket-Sized Conductivity Meter |
| Origin | USA |
| Measurement Range | 0–1999 µS/cm and 0–19.99 mS/cm |
| Resolution | 1 µS/cm / 0.01 mS/cm |
| Accuracy | ±2% of reading |
| Temperature Compensation | Automatic, 0–50 °C |
| Calibration | Auto- or manual 1–2-point with buffer recognition |
| Electrode Diameter | 8 mm |
| Display | LCD with auto-hold |
| Power | 2×CR2032 (3 V) |
| Battery Life | ~200 hours |
| Auto-Off | After 8 min inactivity |
| Dimensions | 236 × 46 × 33 mm |
| Weight | 140 g |
| IP Rating | IP66+ |
| Standard Kit | Meter, replaceable electrode, calibration solutions, batteries, manual |
| Brand | PRIMASCI |
|---|---|
| Origin | Shanghai, China |
| Model | innoLab 10 C |
| Portability | Handheld |
| Conductivity Range | 0–500 mS/cm |
| TDS Range | 0–500,000 ppm (as NaCl) |
| Resistivity Range | 0–100.0 MΩ·cm |
| Salinity Range | 0–325 ppt (Practical Salinity Scale) |
| Temperature Range | −5 to +120 °C |
| Accuracy | ±1% F.S. (Conductivity), ±0.3 °C (Temperature) |
| Resolution | 0.001 µS/cm (low range), 0.01 mS/cm (high range), 0.1 °C |
| Calibration | Auto-ranging 1-point or manual multi-point (up to 3 points) |
| Temperature Compensation | Automatic/manual, −5 to +120 °C, selectable reference temp (15–30 °C, default 25 °C) |
| Electrode Constants | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| TDS Factor | 0.40–1.00 (adjustable) |
| Salinity Factor | 0.65 (PSS-78 compliant) |
| Memory Capacity | 100 data sets with timestamp |
| Display | 40 × 70 mm LCD, 120° viewing angle |
| IP Rating | IP67 |
| Power | 2 × AA alkaline batteries (>500 h operation) |
| Dimensions | 73 × 152 × 42 mm (W × L × H) |
| Weight | 250 g |
| Brand | PRIMASCI |
|---|---|
| Origin | Taiwan |
| Model | innoLab 20C |
| Form Factor | Benchtop |
| Conductivity Range | 0–500 mS/cm |
| TDS Range | 0–500,000 ppm (as NaCl) |
| Resistivity Range | 0–18.30 MΩ·cm |
| Salinity Range | 0–325 ppt |
| Temperature Range | −5 to +120 °C |
| Accuracy | ±0.5% of Full Scale |
| Minimum Resolution | 0.001 µS/cm (at lowest range) |
| Electrode Constants Supported | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| Temperature Compensation | Automatic or Manual (−5 to 120 °C), Reference Temp: 15–30 °C (default 25 °C) |
| TDS Conversion Factor | Adjustable 0.40–1.00 |
| Salinity Conversion Factor | Fixed 0.65 |
| Data Storage | 100 measurement records |
| Power | AC 100–240 V + internal rechargeable Li-ion battery (1300 mAh) |
| Dimensions | 150 × 194 × 56 mm (W × L × H) |
| Weight | 1.0 kg |
| Brand | Ransburg |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 76652-01 / 76652-02 / 76652-03 / 76652-04 |
| Power Supply | 9V Alkaline Battery |
| High Voltage Range | ±0–199.9 kV |
| Short-Circuit Current Range | ±0–1999.9 µA |
| Conductance Range | 0.01–199.9 mS/cm (with 7922-00 Paint Probe) |
| Resistivity Range | 10⁰–10⁹ Ω·cm (typical for solvent-based and waterborne coatings) |
| Electrode Material | Corrosion-Resistant Stainless Steel |
| Compliance | Designed for industrial electrostatic spray process control per ITW Ransburg engineering specifications |
| Brand | ROOKO |
|---|---|
| Model | LX-9830GA |
| Type | Benchtop Voltage Drop Analyzer |
| Measurement Parameters | Contact Resistance, Voltage Drop, Current, Open-Circuit Voltage, Temperature |
| Current Range | 0–300 A (selectable ranges: 0–40 A / 0–60 A / 0–100 A / 0–200 A / 0–300 A) |
| Voltage Range (open-circuit) | 0–12 V / 0–24 V / 0–30 V (optional) |
| Voltage Drop Range | 0–199.99 mV |
| Resolution | 0.01 mV (voltage drop), 0.01 A (current), 0.01 V (voltage) |
| Accuracy | ±1% of reading |
| Test Time Setting | 0.01 s – 99.99 h |
| Temperature Measurement Range | 0–25 °C (integrated sensor) |
| Compliance Standards | QC/T 29106–2004, QC/T 730–2005, ISO 6722:2002, GB/T 2951–1997, GB/T 3048–1994, QC/T 413–2002, SAE USCAR-38:2009 |
| Interface Options | RS-232, USB 2.0 |
| Data Management | Password-protected instrument configuration, pass/fail counting (0–99999), audible/visual alarm on limit violation |
| External Integration | PLC control interface, PC software (optional), printer support, custom fixture compatibility |
| Brand | Sanotac |
|---|---|
| Model | C1000 |
| Application | In-line conductivity detection for chromatographic protein purification |
| Conductivity Range | 1 µS/cm to 500 mS/cm |
| Temperature Range | 0–99 °C |
| Temperature Accuracy | ±1 °C |
| Conductivity Accuracy | ±2% FS |
| Flow Rate Compatibility | 100–1000 mL/min |
| Tubing Connection | 1/8" (3.2 mm) compression fitting |
| Display | 256×64 dot-matrix backlit LCD |
| Control Interface | Front-panel keypad + PC-based software with remote control capability |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions (W×D×H) | 370 × 240 × 95 mm |
| Compliance | FDA 21 CFR Part 11 (audit trail, electronic signature, role-based user access), GLP/GMP-ready architecture |
| Brand | SANXIN |
|---|---|
| Model | 5021 |
| Measurement Range | 0–10.00 mS/cm (auto-ranging across three segments: 0–99.9 μS/cm, 100–999 μS/cm, 1.00–10.00 mS/cm) |
| Resolution | 0.1/1 μS/cm |
| Accuracy | ±1% FS |
| Temperature Compensation | 5–50 °C (automatic, NTC 30 kΩ) |
| Calibration | Single-point auto-calibration with 1413 μS/cm standard solution |
| Power Supply | Two AAA batteries (1.5 V × 2) |
| Dimensions | 39 × 25 × 176 mm |
| Weight | 87 g |
| Ingress Protection | IP57 |
| Origin | Shanghai, China |
| Manufacturer | SANXIN Peirui Instrument Co., Ltd. |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | 5031 |
| Price | ¥426 |
| Measurement Range | (0–5.00) ppt (auto-ranging across three segments: 0–49.9 ppm, 50–499 ppm, 0.50–5.00 ppt) |
| Resolution | 0.1/1 ppm |
| Accuracy | ±1% FS |
| Temperature Compensation | Automatic, 5–50 °C (reference 25 °C, temp. coefficient 2%/°C) |
| Calibration | Single-point auto-calibration with 4.20 ppt standard solution |
| Power Supply | Two AAA batteries (1.5 V × 2) |
| Dimensions | 39 × 25 × 176 mm |
| Weight | 87 g |
| Ingress Protection | IP57 |
| Replaceable Electrode | Yes |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | 5051 |
| Price | USD 60 (approx.) |
| Measurement Range | 0–5.00 ppt |
| Resolution | 0.01 ppt |
| Accuracy | ±1% FS |
| Temperature Compensation | Automatic, 5–50 °C |
| Calibration | Single-point, factory-predefined 3.00 ppt standard |
| Power Supply | Two AAA batteries (1.5 V × 2) |
| Dimensions | 39 × 25 × 176 mm |
| Weight | 87 g |
| Ingress Protection | IP57 |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DDB-11A |
| Measurement Range | (a) 0.0–199.9 µS/cm (deionized water) |
| Accuracy | ±1% FS ±1 digit (basic error) |
| Power Supply | One 9V alkaline battery (6F22) or external 9V DC adapter |
| Dimensions (meter) | 162 × 43 × 25 mm |
| Electrode Dimensions | Ø12 × 130 mm |
| Weight | 210 g (including battery) |
| Operating Temperature | 5–35 °C |
| Compliance | Designed for field-deployable GLP-compliant conductivity measurements in environmental and industrial QA/QC workflows |
| Brand | SANXIN |
|---|---|
| Model | DDS-11C |
| Measurement Range | (0–199.9) µS/cm, (200–1999) µS/cm, (2.00–19.99) mS/cm, (20.0–199.9) mS/cm |
| Accuracy | ±1.0% FS |
| Automatic Temperature Compensation | 0–50 °C |
| Data Storage | 50 sets |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 750 g |
| Electrode Included | 2301-F Plastic-Body Conductivity Cell (K = 1.0, ATC built-in) |
| Calibration Standards Supported | Dual-series recognition (US/EU and Chinese standard solutions) |
| Compliance | Designed for GLP-compliant routine lab use |
| Brand | Sanxin Peri |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | EC5 |
| Price | USD 108 |
| Measured Parameter | Single-Parameter (Conductivity/TDS/Salinity/Temperature) |
| Form Factor | Pen-Style Portable |
| Intended Use | Laboratory & Field Applications |
| Conductivity Range | 0–20.00 mS/cm (equivalent to 0–20,000 µS/cm) |
| TDS Range | 0–10.00 ppt (with conversion factor 0.50) |
| Salinity Range | 0–10.00 ppt (NaCl scale) |
| Resistivity Range | Not applicable (deduced only) |
| Temperature Range | 0–50 °C |
| Accuracy | ±1% FS (Conductivity), ±0.5 °C (Temperature) |
| Minimum Resolution | 0.01 mS/cm / 0.1 µS/cm |
| Calibration | 1–3-point automatic calibration (using 1413 µS/cm and 12.88 mS/cm standard solutions) |
| IP Rating | IP67 |
| Power Supply | 4 × AAA alkaline batteries (DC 3 V), >200 h continuous operation |
| Dimensions (Instrument) | 40 × 40 × 178 mm |
| Weight (Instrument) | 133 g |
| Enclosure | Rugged carry case (255 × 210 × 50 mm, 438 g) including calibration standards, storage vials, KCl soaking solution, lanyard, and batteries |
| Brand | SANXIN Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MP513 |
| Detection Parameter | Single-Parameter (Conductivity) |
| Portability | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0–200 mS/cm (5 auto-ranging segments) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | −10 to +110 °C |
| Accuracy | ±1.0% FS (Conductivity), ±1.5% FS (Overall Specification) |
| Minimum Resolution | 0.001 µS/cm |
| Temperature Compensation | Automatic (0–50 °C), ATC-enabled electrode |
| Data Storage | 100 sets |
| Interface | RS232 with GLP-compliant software |
| IP Rating | IP54 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Measurement Parameters | Single-Parameter (Conductivity) |
| Conductivity Range | 0–200 mS/cm (5 auto-ranging segments) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | −10 to +100 °C |
| Accuracy | ±1.0% FS (Conductivity), ±1.5% FS (Overall Specified Range) |
| Minimum Resolution | 0.001 µS/cm |
| Temperature Compensation | Automatic (0–50 °C, ATC) |
| Data Storage | 100 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant design with audit-ready data handling |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Conductivity Meter |
| Model | MP515 |
| Measurement Parameters | Single-Parameter (Conductivity) |
| Conductivity Range | 0–2000 mS/cm (6 auto-ranging segments) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | −10 °C to 110 °C |
| Accuracy | ±0.5% FS (conductivity), ±0.4 °C (temperature) |
| Minimum Resolution | 0.01 µS/cm |
| Temperature Compensation | Automatic linear (0–50 °C) and nonlinear (for ultrapure water <10 µS/cm) |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| Ingress Protection | IP54 |
| Compliance | GLP-compliant design with audit-ready data logging and timestamped records |