| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Benchtop/Polarized EDXRF |
| Element Range | Na (11) to Am (95), optional C (6) to Am (95) |
| Concentration Range | ppm to 100% |
| Energy Resolution | <135 eV (Mn Kα) |
| Repeatability | <0.1% RSD |
| Detector | HighSense™ Ultra-Low-Noise Silicon Drift Detector (SDD) |
| Compliance | ASTM D6481, ASTM D7751, ASTM D7220, ISO 13032, ASTM D4294, ISO 20847, ISO 8754, IP 336/496/532, JIS K2541-4, GB/T 11140 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart |
| Element Range | CHNSO, CHNS, CHN, NCS, NC, N, S, O (configurable modes) |
| Analysis Time | 5–10 min (sample-weight- and matrix-dependent) |
| Detection Limit | <40 ppm (S: down to 4 ppm with FPD/IR |
| Measurement Precision | ≤0.05% RSD |
| Sample Introduction | Up to 500 µL liquid or 1 g solid |
| Detector Options | Thermal Conductivity Detector (TCD), Flame Photometric Detector / Infrared Detector (FPD/IR), Isotope Ratio Mass Spectrometer (IRMS) interface, Chlorine (Cl) measurement module |
| Combustion Temperature | Up to 1800 °C |
| Compliance | Designed for GLP/GMP environments |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER NS |
| Detection Principle | UV Fluorescence for Sulfur / Chemiluminescence for Nitrogen |
| Sample Types | Liquids, Gases, LPG, Solids |
| Measurement Range | S and N from sub-ppb to percent level |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Control & Data Management Software |
| Compliance | ASTM D5453, D7183, D7184 |
| Optional Autosamplers | 105-position 2-mL vial XYZ autosampler (with auto-dilution & auto-calibration), Gas/LPG autosampler, 20-position solid autosampler |
| Detector | Temperature-controlled UVF and CLD detectors with active feedback loops |
| Automation Level | Fully automated combustion, gas flow control, calibration, and data validation |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0.001–500 mg N |
| Reproducibility | <0.3% RSD |
| Sample Weight | ≥1 g |
| Recovery Rate | 99.5–100% |
| Digestion/Combustion Time | 3–4 min per sample |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 620 × 580 × 500 mm |
| Linearity Range | 0.001–500 mg N |
| Sample Capacity | Up to 125 positions (with optional multi-rack configuration) |
| Gas Flow Control | Electronic Flow Control (EFC) |
| Software Platform | EagerSmart™ Operating Software |
| Compliance | ASTM D515, ISO 13878, AOAC 992.15, USP <467>, EN ISO 13878, and GLP/GMP-ready audit trail support |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart CN/CNS |
| Detection Principle | Dynamic Flash Combustion coupled with Gas Chromatographic Separation |
| Detector Options | TCD (standard), optional chemiluminescence or IR detectors |
| Combustion Temperature | up to 1800 °C (Sn capsule mode) |
| Warranty | 15 years on combustion furnace and TCD detector |
| Automation | Fully software-controlled oxygen injection, sample weighing, and combustion timing |
| Compliance | Designed for GLP/GMP environments |
| Carrier Gas Options | Helium (standard), Argon (cost-optimized alternative) |
| Modular Configurations | Upgradable to CHNS, CHN, NC, NCS, N, S, O modes |
| Sample Types | Solids (soils, sediments, biomass, coal, polymers), liquids (oils, extracts, aqueous solutions), and heterogeneous matrices |
| Throughput | Up to 120 samples/day with dual autosamplers (solid + liquid) |
| Software Platform | EagerQ™ v3.2 with method templates, calibration wizards, and raw data export (CSV, XML, PDF) |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | CD60 |
| Instrument Type | HPTLC Densitometer |
| Operation Mode | Fully Automated |
| Detection Modes | Absorption, Reflection, Fluorescence, Transmission |
| Wavelength Range | 190–900 nm |
| Light Sources | Deuterium Lamp, Tungsten-Halogen Lamp, Mercury Lamp |
| Monochromator | Stepper Motor-Driven Holographic Grating (1200 lines/mm) |
| Spectral Bandwidth | 5–260 nm |
| Wavelength Accuracy | < ±0.1 nm |
| Wavelength Repeatability | < ±0.2 nm |
| Minimum Spatial Resolution | 0.025 mm |
| Imaging Wavelength Range | 190–900 nm |
| Sample Stage Dimensions | 265 × 200 mm |
| Scan Speed | 20 mm/s |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER TX |
| Detection Principle | Combustion Microcoulometry |
| Sample Types | Liquids, Gases, Liquefied Petroleum Gas (LPG), Solids |
| Measurement Range | 0.0025–1000 mg absolute chlorine |
| LOD | 0.025 mg/L |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Software |
| Compliance | ASTM D5808, ASTM D7042, ISO 16939, IP 566, UOP 390, EN ISO 16939, SH/T 0689 |
| Optional Autosamplers | 105-position 2 mL vial XYZ autosampler (with auto-dilution & auto-calibration), Gas/LPG autosampler, 20-position solid autosampler |
| Detector | Temperature-controlled microcoulometric cell with closed-loop feedback control |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | AS30 |
| Instrument Type | Thin-Layer Chromatography (TLC) Sample Spotter |
| Spotting Method | Non-contact spray spotting with programmable overlap capability |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | <0.2 nm |
| Stage Dimensions | 500 × 380 × 180 mm |
| Spotting Speed | 3–120 s/µL (solvent-dependent) |
| Minimum Spotting Volume | 0.1 µL |
| Volume Range Options | 0.1–10 µL and 0.1–100 µL |
| Spotting Precision | ±0.5 nL |
| Programmable Methods | Up to 10 stored protocols |
| Sample Capacity (optional autosampler) | 144 vials |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Elemental Analyzer |
| Nitrogen Measurement Range | 0.001–500 mg N |
| Reproducibility | <0.3% RSD |
| Sample Mass Requirement | ≥1 g |
| Recovery Rate | 99.5–100% |
| Digestion/Combustion Time | 3–4 min per sample |
| Linear Range | 0.001–500 mg N |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 620 × 580 × 500 mm |
| Sample Capacity | Up to 125 positions (with optional 4-position carousel) |
| Compliance | ASTM D5142, AOAC 992.15, ISO 14891, EN ISO 16634-1/-2, USP <28>, FDA 21 CFR Part 11 ready (via EagerSmart software audit trail) |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | Xprep C-IC |
| Instrument Type | Laboratory |
| Category | Ion Chromatography Sample Prep System |
| Sample Introduction Modes | Liquid direct injection & Quartz boat solid injection |
| Fraction Collector Capacity | 65 positions |
| Compatibility | Universal IC interface (vendor-neutral) |
| Combustion Capability | Solids, liquids, gases, and LPG |
| Reagent Dispensing | Integrated precision metering system |
| Compliance Context | Designed for ASTM D7359, ISO 14912, USP <643>, and EPA Method 1694-compliant workflows |
| Brand | Sherwood |
|---|---|
| Origin | United Kingdom |
| Model | M410 |
| Element Detection | Na, K, Li, Ca, Ba |
| Output Units | ppm, mg/L |
| Compliance | ISO 7635, ASTM D2189, USP <731> |
| Software Interface | RS-232 serial output for data logging |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | SG1 / DS20 |
| Spray Method | Programmable, Quantitative, Region-Specific Aerosol Deposition |
| Droplet Size | 1–10 µm |
| Spray Platform Area | 20 × 20 mm |
| Scan Speed | 50–200 mm/s |
| Wavelength Range | 2–4 mm (Note: This value is physically inconsistent with optical spectroscopy |
| likely refers to spray nozzle orifice diameter — corrected to “Nozzle Orifice | 2–4 mm”) |
| Light Sources | Deuterium lamp, Tungsten-halogen lamp, Mercury lamp |
| Wavelength Reproducibility | < 0.2 nm (applicable to integrated UV/Vis detection module, not spray function) |
| Compliance | GxP-ready software architecture with audit trail capability |
| Brand | Biochrom |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biochrom 30+ |
| Price Range | USD 92,000 – 132,000 (based on exchange rate and configuration) |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0–130 mL/hr |
| Maximum Pump Pressure | 45 MPa |
| Autosampler Injection Volume | 1–5000 µL |
| Autosampler Temperature Control | 4 °C to ambient, continuously adjustable |
| Post-Column Reactor Temperature Range | 40–145 °C |
| Detection Wavelengths | 570 nm and 440 nm (dual-wavelength, self-calibrating, parallel signal output with summation capability) |
| Flow Cell Volume | 8 µL |
| Brand | Serstech |
|---|---|
| Origin | Sweden |
| Model | Arx+ |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | 8–10 cm⁻¹ |
| Minimum Wavenumber | 400 cm⁻¹ |
| Spectral Repeatability | <1 cm⁻¹ |
| Laser Excitation Wavelength | 785 nm |
| Display | 3.5-inch color TFT with LED backlight |
| Onboard Storage | 16 GB (up to 100,000 spectra) |
| Operating Temperature | −20 to +50 °C |
| Storage Temperature | −30 to +50 °C |
| Battery Life | Up to 8 hours continuous operation |
| Weight | 590 g |
| IP Rating | IP67 |
| Focus Mechanism | Automatic focus |
| Detection Time | 0.01–60 s (manual or auto-triggered) |
| Sample Compatibility | Solids, liquids, powders, tablets |
| Regulatory Compliance | Fully compliant with FDA 21 CFR Part 11, supports IQ/OQ/PQ documentation |
| Brand | Serstech |
|---|---|
| Origin | Sweden |
| Model | Serstech 100 Indicator |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | 8–10 cm⁻¹ |
| Spatial Resolution | <1 nm |
| Minimum Wavenumber | 400 cm⁻¹ |
| Spectral Reproducibility | <1 cm⁻¹ |
| Laser Excitation Wavelength | 785 nm |
| Laser Power Class | Class 3B (max. 300 mW) |
| Detector | Linear CCD Array |
| Onboard Memory | 16 GB (up to 100,000 spectra) |
| Data Formats | Text, .txt, .csv, .jcamp |
| Interface | USB 2.0 |
| Battery Life | >8 hours continuous operation |
| Weight | 650 g |
| Dimensions | 15.8 × 10.1 × 2.9 cm |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart CHN |
| Measurement Elements | C, H, N (expandable to CHNSO, CHNS, NCS, NC, N, S, O) |
| Analysis Time | 5–10 min (sample-weight and matrix dependent) |
| Detection Limit | <40 ppm |
| Accuracy | ≤0.05% |
| Sample Volume | up to 500 µL |
| Detectors | Thermal Conductivity Detector (TCD), Flame Photometric Detector (FPD), Infrared Detector (IR), Isotope Ratio Mass Spectrometer (IRMS) interface |
| Combustion Temperature | up to 1800 °C |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S2 PUMA Series II |
| Element Range | Na (11) to Am (95) [C (6) to Am (95)] |
| Detection Range | ppm to 100% |
| Energy Resolution | <135 eV |
| Repeatability | <0.1% RSD |
| Detector | HighSense™ Silicon Drift Detector (SDD) |
| Configuration Options | Manual Single-Position, XY Autochanger, Carousel Autosampler |
| Sample Chamber Dimensions | 450 × 420 × 100 mm |
| X-ray Tube | 50 W Rh anode |
| Filter Changer | 10-position automatic |
| Software Suite | SPECTRA.ELEMENTS with Smart-Quant FP, Geo-Quant, Cement-Quant, and regulatory-compliant modules |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | DD80 |
| Instrument Type | Automated TLC Imaging & Densitometry System |
| Operation Mode | Fully Automatic |
| Detection Mode | Low-Fluorescence Substance Imaging |
| Wavelength Options | 254 nm and 366 nm UV |
| Light Sources | White LED, UV Fluorescent Lamps, UV LEDs |
| Imaging Sensor | 24-Megapixel Full-HD Digital Camera |
| Spectral Bandwidth Management | Auto Background Correction & Real-Time Image Optimization |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spatial Resolution | 7560-pixel RGB + IR Photometric Detection System |
| Focusing Mechanism | 19-Point Cross-Hair Autofocus Array |
| Stage Dimensions | 400 × 500 × 440 mm (W × D × H) |
| Frame Rate | 50 fps Continuous Capture |