ModelXPLORER-V with VECTRA Liquid Autosampler
Analytical MethodCombustion Microcoulometry
Measurement Range0–10,000 ppm
Accuracy≤2% CV
Detection Limit10 ppb
Resolution≤2% CV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOctopus
OriginGermany
ModelSAMILLA FIM FL
Camera Resolution12 MP
Magnification40×
Particle Detection PrincipleMorphological Image Analysis
Measurable Size Range0.2 µm – 2 mm
Imaging ModesTransmission Light (standard), Reflectance Light (optional)
ComplianceUSP <788>, USP <789>, Ph. Eur. 2.9.19, ISO 21501-4, FDA 21 CFR Part 11
SoftwareSMILLA View with Audit Trail, LIMS Integration, and GLP/GMP Workflow Support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTrace Elemental Instruments
OriginNetherlands
ModelXPERT-TOC/TNb
Instrument TypeLaboratory TOC/TNb Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption for TOC
Oxidation MethodHigh-Temperature Catalytic Combustion (up to 1000 °C)
Measurement Range0–35,000 µg/L (ppb–ppm)
AccuracyRSD < 1%
Resolution0.0001 µg/L
Detection Limit3 ppb (TOC)
RepeatabilityRSD < 1%
Sample IntroductionValve-Free Funnel-Tec™ Technology
Combustion TubeProCat™ High-Efficiency Catalytic Oxidation Tube
AutosamplerIntegrated 65-Position Liquid Autosampler with On-Deck Stirring & Removable Tray
SoftwareTEIS v5.x (Compliant with FDA 21 CFR Part 11, GLP/GMP Audit Trail)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSherwood
OriginUnited Kingdom
ModelM926, M926S
Instrument TypeBenchtop Chloride Analyzer
Detection PrincipleCoulometric Titration (Silver Nitrate Electrolytic Generation)
Sample VolumeM926: 500 µL
M926S20 µL
Measurement RangeM926: 10–999 mg/L Cl⁻ (equivalent to 2–165 mg% NaCl)
M926S10–299 mmol/L Cl⁻
Detection Limit10 mg/L Cl⁻ (M926)
Response Time≤36 s (typical endpoint detection)
AccuracyM926: ±3 mg/L or <1% RSD at 0.1% Cl⁻
M926S±2% at 100 mmol/L Cl⁻
Linearity≤1% deviation across full range
Repeatability (CV, n=20)<1.5% at mid-range concentration
Temperature ControlIntegrated ambient-temperature-stabilized cell compartment
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTE/Trace Elemental Instruments
OriginNetherlands
ModelXPLORER AOX
Measurement PrincipleHigh-Temperature Combustion–Coulometric Titration
Measurement Range0.0025–1000 µg Cl/L
Accuracy<3% @ 200 ppb Cl
Repeatability<2.5% RSD
LOD0.0025 µg Cl
Resolution0.0025 µg Cl
Combustion TemperatureUp to 1150 °C
Sample Introduction5–1000 mg (solid) or 0.1–10 mL (liquid)
Analysis Time (per sample)3–10 min (excluding pre-treatment)
Carrier GasesO₂ (99.6%), Ar (99.998%)
AutosamplerStandard 20-position, expandable to 60-position
SoftwareTEIS 2 Online Control & Data Processing Platform
ComplianceISO 9562:2004, EN ISO 9562, DIN 38409-H17, EPA Method 1650, HJ 1214–2021, GB/T 34845–2017, GB/T 35613–2017, GB/T 41533–2022, GB/T 22904–2008, GB/T 15959