| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER-V with VECTRA Liquid Autosampler |
| Analytical Method | Combustion Microcoulometry |
| Measurement Range | 0–10,000 ppm |
| Accuracy | ≤2% CV |
| Detection Limit | 10 ppb |
| Resolution | ≤2% CV |
| Brand | Octopus |
|---|---|
| Origin | Germany |
| Model | SAMILLA FIM FL |
| Camera Resolution | 12 MP |
| Magnification | 40× |
| Particle Detection Principle | Morphological Image Analysis |
| Measurable Size Range | 0.2 µm – 2 mm |
| Imaging Modes | Transmission Light (standard), Reflectance Light (optional) |
| Compliance | USP <788>, USP <789>, Ph. Eur. 2.9.19, ISO 21501-4, FDA 21 CFR Part 11 |
| Software | SMILLA View with Audit Trail, LIMS Integration, and GLP/GMP Workflow Support |
| Brand | Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPERT-TOC/TNb |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption for TOC |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Measurement Range | 0–35,000 µg/L (ppb–ppm) |
| Accuracy | RSD < 1% |
| Resolution | 0.0001 µg/L |
| Detection Limit | 3 ppb (TOC) |
| Repeatability | RSD < 1% |
| Sample Introduction | Valve-Free Funnel-Tec™ Technology |
| Combustion Tube | ProCat™ High-Efficiency Catalytic Oxidation Tube |
| Autosampler | Integrated 65-Position Liquid Autosampler with On-Deck Stirring & Removable Tray |
| Software | TEIS v5.x (Compliant with FDA 21 CFR Part 11, GLP/GMP Audit Trail) |
| Brand | Sherwood |
|---|---|
| Origin | United Kingdom |
| Model | M926, M926S |
| Instrument Type | Benchtop Chloride Analyzer |
| Detection Principle | Coulometric Titration (Silver Nitrate Electrolytic Generation) |
| Sample Volume | M926: 500 µL |
| M926S | 20 µL |
| Measurement Range | M926: 10–999 mg/L Cl⁻ (equivalent to 2–165 mg% NaCl) |
| M926S | 10–299 mmol/L Cl⁻ |
| Detection Limit | 10 mg/L Cl⁻ (M926) |
| Response Time | ≤36 s (typical endpoint detection) |
| Accuracy | M926: ±3 mg/L or <1% RSD at 0.1% Cl⁻ |
| M926S | ±2% at 100 mmol/L Cl⁻ |
| Linearity | ≤1% deviation across full range |
| Repeatability (CV, n=20) | <1.5% at mid-range concentration |
| Temperature Control | Integrated ambient-temperature-stabilized cell compartment |
| Compliance | Designed for GLP/GMP environments |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER AOX |
| Measurement Principle | High-Temperature Combustion–Coulometric Titration |
| Measurement Range | 0.0025–1000 µg Cl/L |
| Accuracy | <3% @ 200 ppb Cl |
| Repeatability | <2.5% RSD |
| LOD | 0.0025 µg Cl |
| Resolution | 0.0025 µg Cl |
| Combustion Temperature | Up to 1150 °C |
| Sample Introduction | 5–1000 mg (solid) or 0.1–10 mL (liquid) |
| Analysis Time (per sample) | 3–10 min (excluding pre-treatment) |
| Carrier Gases | O₂ (99.6%), Ar (99.998%) |
| Autosampler | Standard 20-position, expandable to 60-position |
| Software | TEIS 2 Online Control & Data Processing Platform |
| Compliance | ISO 9562:2004, EN ISO 9562, DIN 38409-H17, EPA Method 1650, HJ 1214–2021, GB/T 34845–2017, GB/T 35613–2017, GB/T 41533–2022, GB/T 22904–2008, GB/T 15959 |