BrandRudolph
OriginUSA
ModelDDM 2911
Instrument TypeOscillating U-Tube Densitometer
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquids
Density Range0–3 g/cm³
Density Resolution0.00001 g/cm³
Density Accuracy±0.00005 g/cm³
Temperature Range0–95 °C (100 °C optional)
Temperature Control Accuracy±0.01 °C
Minimum Sample Volume1 mL
ComplianceASTM D4052, ASTM D5002, ASTM D1250, ASTM D5931-96, DIN 51757, ISO 12185
Display10.4″ color TFT touchscreen
Cell MaterialBorosilicate glass with PTFE fittings
Interfaces5× USB, RS-232, Ethernet (Cat-5)
Operating SystemWindows 7 Embedded
Data Storage32 GB internal flash memory
Power Supply85–260 VAC
Video View™ Technology (U.S. Patent No. 7,437,909)10× digital zoom for real-time bubble visualization in oscillation tube
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRudolph
OriginUSA
ModelDDM2911 Autofill
Instrument TypeOscillating U-Tube Density Meter
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquids
Density Range0–3 g/cm³
Density Resolution0.000001 g/cm³
Density Accuracy±0.000010 g/cm³
Density Repeatability±0.000002 g/cm³
Temperature Control Range0–100 °C
Temperature Accuracy±0.01 °C
Temperature Repeatability±0.001 °C
Display Precision0.000001 g/cm³ / 0.001 °C
Minimum Sample Volume1 mL
Integrated Viscosity CorrectionYes
Regulatory Compliance21 CFR Part 11, GLP/GMP-ready
Data Storage32 GB internal memory
Interface Ports5× USB, 2× RS232, 2× Ethernet, 1× HDMI
Touchscreen10.4″ color LCD
Video View™ Technology10× digital zoom for real-time U-tube bubble visualization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRudolph
OriginUSA
ModelDDM2910
Instrument TypeLaboratory Benchtop Oscillating U-Tube Densitometer
Sample TypeLiquids
Density Range0–3 g/cm³
Density Accuracy±0.00001 g/cm³
Density Repeatability±0.00001 g/cm³
Temperature Control Range0–100 °C
Temperature Accuracy±0.03 °C
Temperature Repeatability±0.02 °C
Display Resolution0.0001 g/cm³ / 0.01 °C
Minimum Sample Volume1 mL
Viewing SystemVideo View™ (10× magnification, real-time U-tube bubble monitoring)
ComplianceFDA 21 CFR Part 11, GLP/GMP-ready, IQ/OQ documentation available
Interface5× USB, 2× RS232, 2× Ethernet, 1× HDMI
Display10.4″ color TFT touchscreen
Onboard Storage32 GB SSD
Viscosity CorrectionAutomatic, integrated algorithm
Reference CellBuilt-in temperature-stabilized reference measurement cell
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRudolph
OriginUSA
ModelDDM2909
Instrument TypeOscillating U-tube Densitometer
Form FactorBenchtop Laboratory Instrument
Sample StateLiquid
Density Range0–3 g/cm³ (operable from 32°F to 212°F)
Density Accuracy±0.0001 g/cm³
Temperature Accuracy±0.05 °C
Density Repeatability±0.00002 g/cm³
Temperature Repeatability±0.02 °C
Temperature Control Range0–70 °C
Minimum Sample Volume< 1 mL
Display10.4″ color LCD touchscreen
Connectivity5× USB, 2× RS232, 2× Ethernet, 1× HDMI
Onboard Storage32 GB
Regulatory Compliance21 CFR Part 11 compliant software with audit trail, IQ/OQ documentation support
Key FeatureVideo View™ technology (U.S. Patent No. 7,437,909) for real-time 10× magnified visualization of bubble formation and settling in the oscillating U-tube
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRudolph
OriginUSA
ModelDDM2911 Plus
Instrument TypeOscillating U-Tube Density Meter
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquids
Density Range0–3 g/cm³
Density Accuracy±0.000010 g/cm³
Density Repeatability±0.000002 g/cm³
Display Resolution0.000001 g/cm³
Temperature Control Range0–100 °C
Temperature Accuracy±0.01 °C
Temperature Repeatability±0.001 °C
Minimum Sample Volume1 mL
Built-in Reference CellYes
Viscosity CorrectionAutomatic
ComplianceFDA 21 CFR Part 11, GLP/GMP-ready
Data Interfaces5× USB, 2× RS232, 2× Ethernet, 1× HDMI
Display10.4″ Color TFT Touchscreen
Onboard Storage32 GB
Video View™ Magnification10× Real-time U-tube Imaging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicrotrac
ModelBELPYCNO
TypeBenchtop True Density Analyzer for Solids
Measurement PrincipleGas Pycnometry (Helium/Nitrogen/SF₆)
Density RangeAll Solid Materials
Density Accuracy±0.0001 g/cm³
Repeatability±0.01% (RSD)
Resolution0.01%
Minimum Sample Volume0.3 cm³
Temperature Range15–35 °C (standard)
Pressure RangeAtmospheric to 150 kPa
Safety FeaturesIntegrated pressure relief valve
Calibration StandardsInternal calibration spheres (multiple sizes)
ComplianceASTM D5550, ISO 12154, USP <699>, ISO 18857-1
SoftwareBELPyCNOSoft v3.x with audit trail, user management, and 21 CFR Part 11 compliance options
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicrotrac
OriginItaly
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBELPYCNO L
Instrument TypeTrue Density Analyzer
Instrument ClassBenchtop Laboratory Analyzer
Sample TypeSolids, Powders, Pastes, Liquids
Measurement PrincipleGas Displacement Pycnometry (Helium-Based)
Pressure RangeVacuum to 2.5 bar
Temperature Control Range14–40 °C (Peltier-Driven, Optional)
Temperature Stability±0.01 °C
Density Accuracy±0.01%
Density Repeatability±0.01%
Resolution0.01%
Minimum Sample Volume0.3 cm³
Standard Sample Cell Volumes20 mL, 40 mL, 60 mL
Optional Sample Cell Volumes4 mL, 100 mL
Reference Cell ConfigurationThree Integrated Reference Cells
Pressure SensorHigh-Stability Absolute Sensor (0–2.5 bar), 19-bit A/D, Drift ≤ ±0.02 mbar
Gas OptionsHe (standard), N₂, SF₆
Inlet Pressure Range160–240 kPa (1.6–2.4 bar)
ComplianceASTM D5550, ISO 12154, USP <699>, ISO 4590, ASTM D6226-10
InterfaceRS-232 (COM) or USB
Dimensions (W×H×D)25 × 33 × 45 cm
Weight17 kg
Operating Environment15–30 °C, 20–80% RH
Power85–264 VAC, 50/60 Hz, 240 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRudolph
OriginUSA
ModelDDM2911 + Autoflex R837
Instrument TypeOscillating U-tube Densitometer
ConfigurationBenchtop Laboratory System
Sample TypeLiquids
Density Range0–3 g/cm³
Density Resolution0.00001 g/cm³
Density Accuracy±0.00005 g/cm³
Temperature Control Range0–95 °C (100 °C optional)
Temperature Stability±0.01 °C
Minimum Sample Volume1 mL
ComplianceASTM D4052, ASTM D5002, ASTM D1250, ASTM D5931-96, ISO 12185, DIN 51757
InterfaceUSB ×5, RS-232, Ethernet (Cat-5)
Display10.4″ color TFT touchscreen
ConstructionBorosilicate glass U-tube, PTFE fluidic interfaces
Data Storage32 GB internal flash memory
Operating SystemWindows 7 Embedded
VideoView™ Technology (U.S. Patent No. 7,437,909)10× digital zoom for real-time bubble visualization across full U-tube length
Viscosity CompensationAutomatic in-situ correction
Regulatory Support21 CFR Part 11 compliant audit trail, electronic signatures, IQ/OQ/PQ documentation package
Power Input85–260 VAC, 50/60 Hz