- All
- Favorite
- Popular
- Most rated
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow with 3D Topography Module |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.01° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | Unlimited (L) × 100 mm (W) × 320 mm (D) |
| Max Sample Size | Unlimited (L) × 320 mm (W) × 22 mm (H) |
| Imaging Sensor | 5.3 MP CMOS, 2592 × 2048 pixels |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MINI X |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption (Combined with Dynamic Pre-evacuation) |
| Analysis Stations | 4 |
| Surface Area Range | ≥0.01 m²/g (no upper limit) |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–133.3 kPa |
| Measurement Theory | Static Volumetric Method + Advanced Free Space Monitoring (AFSM™) |
| Compliance Options | FDA 21 CFR Part 11, IQ/OQ Documentation Package Available |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 701 |
| Measurement Range | 1–2000 mN/m |
| Resolution (Surface Tension) | 0.001 mN/m |
| Accuracy (Surface Tension) | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Resolution | 0.01 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Density Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.05–0.1 µN |
| Contact Angle Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Motorized Stage Speed | 0.01–500 mm/min |
| Stage Positioning Accuracy | 0.016 µm |
| Dimensions (W×D×H) | 33.3 × 24.4 × 62 cm |
| Weight | 13–16 kg |
| Power Supply | 85–264 VAC, 47–440 Hz, 13 W |
| Brand | Porometer |
|---|---|
| Model | POROLUX™ Revo X |
| Origin | Germany |
| Measurement Principle | Gas-Liquid Capillary Flow (Capillary Flow Porometry, CFP) |
| Pore Size Range | 80 nm – 500 µm |
| Bubble Point Pressure Range | 0–8 bar (0–116 psi) |
| Max. Gas Flow Rate | 200 L/min |
| Dual Auto-Switching Flow Sensors | 0–10 L/min & 0–200 L/min |
| Dual Auto-Switching Pressure Sensors | 0–1 bar & 0–10 bar |
| Sample Holder Diameter | 25 mm |
| Max. Sample Thickness | 3 mm |
| Measurement Modes | Bubble Point (BP x-mL, BP pCF), Mean Flow Pore Size, Minimum Pore Size, Pore Size Distribution, Cumulative Flow Distribution, Gas Permeability |
| Optional Modules | Liquid Permeability, Fluid Source Integration |
| Software | PoreSmart™ with Curve Fitting, Statistical Pore Quantification (Total Pore Count, Total Pore Area [% & µm²], Open Porosity, Calculated Permeability in Darcy) |
| Patented Measurement Method | MP² (Multi-Step Pressure Progression) Technology |
| Compliance Ready | ASTM F316-22, ISO 15709:2022, USP <801>, GLP/GMP Data Integrity Support (Audit Trail, Electronic Signatures, 21 CFR Part 11 Ready) |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Lite |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Contact Angle Accuracy | ±0.1° (standard), ±0.01° (high-precision mode) |
| Surface & Interfacial Tension Range | 0.01–2000 mN/m |
| Surface & Interfacial Tension Accuracy | ±0.1 mN/m (standard), ±0.01 mN/m (high-precision mode) |
| Camera Resolution | 1936 × 1216 pixels |
| Sample Stage Dimensions (L×W×H) | 495 × 130 × 310 mm |
| Max. Sample Weight Capacity | 5 kg |
| Image Magnification | Fixed optical path with high-magnification telecentric lens system |
| Measurement Modes | Static CA, Advancing/Receding CA, Roll-off Angle, Surface Free Energy (Owens-Wendt, Wu, van Oss), Interfacial Tension, Batch Analysis, Roughness-Corrected CA, Single-Fiber CA |
| Software | OneAttension v4.x (FDA 21 CFR Part 11 compliant audit trail option available) |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BELMASS II |
| Instrument Type | Chemisorption Analyzer with Integrated Online MS Detection |
| Gas Inlet Ports | Up to 16 |
| Temperature Stability | ±0.001 °C |
| Supported Techniques | TPD, TPR, TPS, Pulse Titration, BET Surface Area Analysis (via coupled gas dosing) |
| Mass Range | 1–200 amu |
| Detector | Faraday Cup / Continuous Dynode Electron Multiplier (C-SEM) |
| Minimum Detectable Concentration | <1 ppm (gas-dependent) |
| Scan Speed Options | Auto, 0.01–10 sec per amu (selectable) |
| Detection Channels | Up to 16 simultaneous mass channels |
| Sample Interface | Heated capillary transfer line (up to 300 °C), integrated dry scroll pump |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 703D |
| Measurement Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Display Range | −20 to +200 °C |
| Temperature Display Accuracy | ±0.01 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Density Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.1 µN |
| Weight | 11 kg |
| Dimensions (W×D×H) | 33.3 × 24.4 × 62 cm |
| Power Supply | 85–264 VAC, 47–440 Hz, 13 W |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MR1 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Dynamic Gas Flow Adsorption Method |
| Analysis Stations | 1 Pre-treatment Station, 1 Analysis Station |
| Surface Area Range | >0.01 m²/g |
| Pressure Range | 0.30 (standard), 0.02–0.9 (upgraded) |
| Adsorptive Gases | He/N₂ or He/Kr mixtures |
| Pretreatment Temperature | Room Temperature to 400 °C |
| Repeatability | <±1% |
| Measurement Time per Sample | ~10 min (analysis only) |
| Compliance Option | FDA 21 CFR Part 11 & 3Q Validation Support |
| Control Interface | Integrated Touchscreen (standalone operation) |
| Dimensions | W350 × D368 × H553 mm |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow Wafer |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | Contact angle, surface tension, interfacial tension, surface free energy |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Sizes | 2", 3", 4", 5", 6", 8", 12" wafers |
| Image Resolution | 2592 × 2048 (5.3 MP) |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m (derived via pendant/sessile drop analysis) |
| Maximum Sample Diameter | 12-inch silicon wafer |
| Stage Load Capacity | 500 g |
| Automated Functions | Motorized XYZ translation + programmable rotation (0–360°), four independent software-controlled dispensers with disposable tips |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow HPC High Pressure Chamber |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0.1–179.9° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | Unlimited × 100 mm × 320 mm |
| Maximum Sample Size | 765 mm × 230 mm × 435 mm |
| Stage Load Capacity | 29 kg |
| Imaging Sensor | 5.3 MP CMOS, 2592 × 2048 pixels |
| Pressure Control | Automated via integrated precision pump |
| Temperature Range | Ambient to elevated temperatures (optional sub-ambient cooling available) |
| Chamber Design | Piston-driven high-pressure cell with corrosion-resistant wetted materials (e.g., Hastelloy C-276, sapphire windows) |
| Fluid Handling | Dual-path intelligent injection valve for direct syringe-based dispensing and in-line cleaning without pump priming |
| Surface Activity Preservation | Piston displacement maintains constant bulk-phase surfactant concentration during pressure ramping |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MAX X |
| Instrument Type | Static Vapor Adsorption Analyzer |
| Pressure Sensor Ranges | 1000 Torr / 10 Torr / 0.1 Torr |
| Temperature Control | Heated Manifold (50 °C standard, optional 80 °C), Air-Bath Sample Chamber |
| Gas Path | Electropolished Stainless Steel with Metal-Sealed Pneumatic Valves |
| Free Space Compensation | Patented Advanced Free Space Measurement (AFSM™) Technology |
| Vapor Compatibility | H₂O, Ethanol, Benzene, and other non-corrosive VOCs (up to 40 °C standard |
| Gas Inlets | Standard 3-port corrosion-resistant |
| Measurement Modes | High-Precision Mode (3 sample + 1 reference station) & Multi-Station Mode (4 sample stations + dedicated P₀ port) |
| Software | BELCONTROL OS with real-time trend logging, system diagnostics, email status alerts, and multilingual UI (English/Japanese) |
| Compliance Support | Designed for GLP/GMP-aligned workflows |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BELSORP MAX G |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Volumetric Gas Adsorption (Dynamic & Static Mode) |
| Number of Analysis Stations | 3 or 6 |
| Operating Temperature Range | 10–35 °C |
| Storage Temperature Range | 0–50 °C |
| Temperature Control Accuracy | ±1 °C |
| Vacuum System | Dual-stage rotary vane pump, ultimate vacuum ≤1 × 10⁻³ mmHg (≤0.13 Pa) |
| Pressure Sensors | 1 Torr, 10 Torr, and 1000 Torr high-precision capacitance manometers |
| Minimum Detectable Pressure Change | <1 × 10⁻⁵ Pa |
| Free Space Calibration | AFSM™ (Automatic Free Space Measurement) patented technology |
| Isotherm Range | P/P₀ = 1 × 10⁻⁷ to 0.997 at 77 K (N₂) and 87 K (Ar) |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP HP |
| Pressure Range | Up to 20 MPa (optional: 13.5 MPa) |
| Pressure Sensor Options | 1, 1.5, 2, 3.5, 13.5, or 20 MPa (±0.08% F.S.) |
| Temperature Control Range | 4.2 K – 673 K (via liquid He/N₂ cryostats, resistive furnaces, Peltier units, and air-bath thermal management) |
| Gas Inlets | 6 total (1 He for dead-volume calibration, 1 compressed air, 4 adsorptive gases) |
| Vacuum System | Optional turbomolecular pump + vacuum gauges |
| Compliance | Built-in compressibility factor (Z) and virial coefficient correction for non-ideal gas behavior |
| Sealing | Swagelok® filter-faced ferrules (0.5 µm pore size) |
| Thermal Stability | Air-bath manifold & reference chamber (15–35 °C, ±0.1 °C) |
| Software | BELSIM™ (isotherm modeling, PCT analysis), optional BELDyna™ (kinetic modeling: concentration vs. time, effective diffusivity, mass transfer coefficients) |
| Brand | Porometer |
|---|---|
| Model | POROLIQ |
| Origin | Germany |
| Technology | Liquid-Liquid Displacement (LLP) |
| Measurement Principle | Capillary Flow Porometry via Immiscible Liquid Pair (e.g., Isopropanol/Water) |
| Minimum Detectable Pore Diameter | 2 nm |
| Data Acquisition Mode | Stepwise Pressure Ramp with Equilibrium Validation Algorithm |
| Compliance Framework | ASTM F316-22, ISO 15901-1, USP <801>, GLP/GMP-ready audit trail support |
| Brand | Porometer |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | POROLUX Cito Series |
| Price Range | USD 14,000 – 140,000 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Flow Range | 200 L/min |
| Pressure Range | 35 bar (500 psi) |
| Measurement Principle | Gas-Liquid Displacement Method (Capillary Flow Porometry) |
| Repeatability | ≤1% |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 702ET |
| Measurement Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Resolution | 0.01 °C |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Compliance | ASTM D971, IEC 62961 |
| Density Measurement Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.1 µN |
| Sample Stage Speed | 0.01–500 mm/min |
| Positional Accuracy | ±0.26 µm |
| Brand | Porometer |
|---|---|
| Origin | Germany |
| Model | POROLUX BP |
| Pressure Range | 0–5 bar (0–75 psi) |
| Pore Size Detection Range | 0.13–300 µm |
| Measurement Principle | Bubble Point Method (Capillary Flow Porometry) |
| Compliance | ASTM F316-22, ISO 4003, USP <801> |
| Software | POROLUX Control Suite v3.x (GLP-compliant audit trail, user access levels, 21 CFR Part 11 ready) |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow |
| Instrument Type | Benchtop Dynamic Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Contact Angle Accuracy | ±0.01° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Imaging System | USB 3.0 Digital Camera with 8× Optical Zoom & High-Power Monochromatic LED Illumination |
| Sample Stage Dimensions | 765 mm × 230 mm × 435 mm (W × D × H) |
| Maximum Sample Weight | 29 kg |
| Environmental Monitoring | Integrated Temperature & Humidity Sensors |
| Software Platform | OneAttension v4.x with Audit Trail, CFR 21 Part 11 Compliance Options |
| Key | Brand: Porometer |
|---|---|
| Origin | Germany |
| Model | POROLUX Revo |
| Measurement Principle | Capillary Flow (Gas-Liquid Displacement) |
| Max Flow Rate | 200 L/min |
| Pressure Range | 35 bar (500 psi) |
| Repeatability | ≤1% |
| Minimum Pore Size | 13 nm |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 700 |
| Measurement Range | 1–2000 mN/m |
| Resolution | 0.0001 mN/m (static), 0.001 mN/m (dynamic) |
| Accuracy | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Accuracy | ±0.01 °C |
| Measurement Methods | Du Noüy Ring, Wilhelmy Plate, Dynamic Contact Angle, CMC, Surface Free Energy, Washburn Penetration, Adhesion Force, Sedimentation, Density |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELCAT II |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Dynamic Flow Method |
| Number of Gas Inlets | 8 (Pre-treatment), 3 (Carrier), 8 (Pulse), 8 (Mixing) |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±1 °C |
| Heating Rates | 50–500 °C at 70 °C/min |
| Pressure Range | Atmospheric |
| Key Functions | TPD, TPR, TPO, TPRx, Pulse Chemisorption, Single-point BET, Breakthrough Curve Analysis |
| Gas Compatibility | He, Kr, N2, Ar, O2, H2, CO, CO2, NH3, H2O, NO, SO2, H2S, CH3OH, C2H5OH, Toluene, Benzene, and other reactive/volatile species |
| Thermal Conductivity Detector (TCD) | Quad-wire configuration with W–Re or gold-plated tungsten filaments |
| resolution | 1 μV |
| Mass Flow Controllers (MFCs) | 3–4 units |
| Sample Volume Capacity | 0–1 cm³ |
| Pulse Loop Volumes | 0.3 cm³, 1 cm³, or custom |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flex |
| Instrument Type | Video-Based Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Contact Angle Accuracy | ±0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 mm × 320 mm |
| Maximum Sample Size (L×W×H) | 763 × 230 × 435 mm |
| Stage Load Capacity | 26 kg |
| Imaging System | USB 3.0 Digital Camera with 8× Zoom, High-Intensity Monochromatic LED Illumination |
| Image Resolution | 1936 × 1216 (optional Theta Flow high-speed camera available) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Microtrac |
|---|---|
| Origin | Italy |
| Model | BELPORE Series |
| Measurement Volume Range | 0.5–2 cm³ |
| Pressure Range | Vacuum to 414 MPa |
| Volume Measurement Accuracy | Better than 1% F.S. |
| Pressure Measurement Accuracy | Better than 0.1% F.S. |
| Maximum Data Points | 10,000 (intrusion) + 10,000 (extrusion) |
| Certified | CE, ISO 9001 |
Show next