Add to compare
BrandBruker
OriginBelgium
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSKYSCAN 2214
X-ray Source20–100 kV, 10 W, <5 µm focal spot size at 4 W
Maximum Voxel Resolution<0.35 µm (16 MP detector) / <0.45 µm (11 MP detector)
Max Reconstructed Volume14456 × 14456 × 2630 px (16 MP) or 11840 × 11840 × 2150 px (11 MP)
Sample CapacityØ ≤ 75 mm, H ≤ 70 mm (standard)
Detector16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper
Spatial & Density Resolution<0.35 µm (16 MP) / <0.45 µm (11 MP), isotropic voxel capability
Reconstruction EngineInstaRecon® real-time GPU-accelerated 3D reconstruction
Scan ModesCone-beam, helical, phase-contrast enabled, dynamic time-lapse
ComplianceFully compatible with ASTM E1441, ISO 15732, and USP <1059> for non-destructive volumetric analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginBelgium
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelX4 POSEIDON
Detector TypeHigh-Resolution sCMOS Semiconductor Sensor
Scanning ModeTranslation-Rotation (TR)
Spatial Resolution≤2 µm (JIMA-verified)
System ArchitectureModular, Field-Upgradable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginBelgium
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSkyScan 1275
X-ray Source20–100 kV, 10 W, < 5 µm focal spot size at 4 W
Detector3 MP CMOS flat-panel detector (1944 × 1536 effective pixels)
Spatial Resolution< 4 µm (nominal, at maximum magnification)
Density Resolution< 4 µm (nominal, inferred from spatial resolution and contrast transfer performance)
Sample CapacityMax height 120 mm, max diameter 96 mm
Dimensional Measurement AccuracyConsistent with < 4 µm spatial resolution under calibrated conditions
Density Measurement AccuracySupported by high dynamic range (16-bit) detector and beam-hardening correction algorithms
Power RequirementStandard 230 V AC, 50/60 Hz, single-phase outlet
Radiation SafetyCompliant with IEC 61000-6-3, IEC 61000-6-4, and national regulatory requirements for Class II B radiation devices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginBelgium
ModelSkyScan 1273
X-ray Source40–130 kV, up to 39 W
Detector6 MP CMOS flat-panel (3072 × 1944 pixels)
Spatial Resolution< 5 µm
Voxel Size< 3 µm
Max Sample DimensionsØ250 mm × H250 mm
Max Sample Weight20 kg
Reconstructed Volumeup to 4800 × 4800 pixels
External Dimensions1250 × 815 × 820 mm (W × D × H)
Radiation Leakage< 1 µSv/h at any point on external surface
Power Supply100–240 V, 50–60 Hz, 3 A
Weight400 kg (net)