| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Voxel Resolution | <0.35 µm (16 MP detector) / <0.45 µm (11 MP detector) |
| Max Reconstructed Volume | 14456 × 14456 × 2630 px (16 MP) or 11840 × 11840 × 2150 px (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm (standard) |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Spatial & Density Resolution | <0.35 µm (16 MP) / <0.45 µm (11 MP), isotropic voxel capability |
| Reconstruction Engine | InstaRecon® real-time GPU-accelerated 3D reconstruction |
| Scan Modes | Cone-beam, helical, phase-contrast enabled, dynamic time-lapse |
| Compliance | Fully compatible with ASTM E1441, ISO 15732, and USP <1059> for non-destructive volumetric analysis |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X4 POSEIDON |
| Detector Type | High-Resolution sCMOS Semiconductor Sensor |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | ≤2 µm (JIMA-verified) |
| System Architecture | Modular, Field-Upgradable |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SkyScan 1275 |
| X-ray Source | 20–100 kV, 10 W, < 5 µm focal spot size at 4 W |
| Detector | 3 MP CMOS flat-panel detector (1944 × 1536 effective pixels) |
| Spatial Resolution | < 4 µm (nominal, at maximum magnification) |
| Density Resolution | < 4 µm (nominal, inferred from spatial resolution and contrast transfer performance) |
| Sample Capacity | Max height 120 mm, max diameter 96 mm |
| Dimensional Measurement Accuracy | Consistent with < 4 µm spatial resolution under calibrated conditions |
| Density Measurement Accuracy | Supported by high dynamic range (16-bit) detector and beam-hardening correction algorithms |
| Power Requirement | Standard 230 V AC, 50/60 Hz, single-phase outlet |
| Radiation Safety | Compliant with IEC 61000-6-3, IEC 61000-6-4, and national regulatory requirements for Class II B radiation devices |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SkyScan 1273 |
| X-ray Source | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel (3072 × 1944 pixels) |
| Spatial Resolution | < 5 µm |
| Voxel Size | < 3 µm |
| Max Sample Dimensions | Ø250 mm × H250 mm |
| Max Sample Weight | 20 kg |
| Reconstructed Volume | up to 4800 × 4800 pixels |
| External Dimensions | 1250 × 815 × 820 mm (W × D × H) |
| Radiation Leakage | < 1 µSv/h at any point on external surface |
| Power Supply | 100–240 V, 50–60 Hz, 3 A |
| Weight | 400 kg (net) |