- All
- Favorite
- Popular
- Most rated
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabTouch-aw |
| Measurement Range | 0.030–1.000 aw |
| Temperature Control Range | 15–30 °C |
| Accuracy | ±0.001 aw |
| Temperature Accuracy | ±0.1 °C |
| Display | Full-color TFT touchscreen |
| Probe Type | Patented Resistive Electrolyte Sensor (REMS) |
| Standard Reference | Long-life saturated salt solution standards |
| Host Weight | 1 kg |
| Compliance | NIST-traceable calibration, FDA-recognized methodology, ISO 21807, AOAC 975.34, USP <1112> |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER-V with XLS-26 Liquid Autosampler |
| Detection Principle | UV Fluorescence (S) / Chemiluminescence (N) |
| Portability | Benchtop (Non-portable) |
| Analyte Types | Total Sulfur and Total Nitrogen |
| Measurement Range | 20 ppb – 10,000 ppm |
| Analysis Time | 2–6 minutes per sample |
| LOD | 10 ppb (S and N) |
| Accuracy | ±2% of reading |
| Brand | Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER TX/TS |
| Detection Principle | Combustion Microcoulometry |
| Sample Types | Solids, Liquids, Gases, LPG |
| Measurement Range (S) | 0.0020–500 mg |
| Measurement Range (Cl) | 0.0025–1000 mg |
| LOD (S) | 0.020 mg/L |
| LOD (Cl) | 0.025 mg |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional |
| Brand | Octopus |
|---|---|
| Origin | Germany |
| Model | SAMILLA FIM |
| Detection Principle | High-Resolution Flow Imaging Microscopy (HiRes-FIM) |
| Particle Size Range | 0.2 µm – 2 mm |
| Camera Options | 12 MP monochrome or color, high-frame-rate sensor |
| Auto-focus | Real-time autofocus without focus beads |
| Magnification Switching | Tool-free, RFID-recognized modular objectives |
| Compliance | USP <788>, USP <789>, Ph. Eur. 2.9.19, ISO 14644-1, FDA 21 CFR Part 11, GLP/GMP-ready |
| Software | SMILLA View v5.x with audit trail, electronic signatures, LIMS integration via ASTM E1384 / LADS framework |
| Cleaning | Fully automated post-run rinse and backflush cycle |
| Pump Configurations | MACRO (peristaltic), MICRO1 (single syringe), MICRO2 (dual alternating syringe), HYBRID (peristaltic + syringe) |
| Brand | NovaSina |
|---|---|
| Origin | Switzerland |
| Model | LabStart-aw |
| Instrument Type | Portable |
| Measurement Range | 0.030–1.000 aw |
| Accuracy | ±0.01 aw |
| Temperature Range | 15–30 °C |
| Temperature Accuracy | ±0.1 °C |
| Display | Backlit LCD (shows aw, temperature, RH%) |
| Weight | 1 kg |
| Sample Cup Capacity | 20 reusable cups included |
| Calibration Standard | Non-consumable, multi-year service life |
| Brand | NovaSina |
|---|---|
| Origin | Switzerland |
| Model | LabMaster-aw neo |
| Measurement Range | 0.0300–1.000 aw |
| Accuracy | ±0.0001 aw |
| Temperature Control Range | 0–60 °C |
| Temperature Stability | ±0.01 °C |
| Display | 240 × 480 LCD |
| Dimensions | 260 × 440 × 220 mm |
| Weight | 9.8 kg |
| Power Supply | 90–260 V, 50/60 Hz, max. 65 W |
| Protection Rating | IP21 |
| Interface | RS-232, USB, D-Sub 9M/9F |
| Brand | NovaSina |
|---|---|
| Origin | Switzerland |
| Model | LabSwift-aw |
| Instrument Type | Portable |
| Measurement Range | 0.03–1.000 a<sub>w</sub> |
| Accuracy | ±0.001 a<sub>w</sub> |
| Temperature Operating Range | 5–45 °C |
| Host Weight | 1.2 kg |
| Calibration | Factory-performed 6-point calibration |
| Data Storage | Integrated SD card |
| Display | Large LCD |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER TS |
| Detection Principle | Combustion Microcoulometry |
| Portability | Benchtop (Non-portable) |
| Analyte | Total Sulfur (S) |
| Measurement Range | 0.0020–500 mg absolute sulfur |
| Detection Limit | 0.020 mg/L |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Control & Data Management Software |
| Compliance | ASTM D3229, ASTM D5453, ASTM D7039, ISO 20846, ISO 20884, IP 512, UOP 97, EN ISO 20846, SH/T 0689 |
Show next