Empowering Scientific Discovery

Dah Chong Hong Scientific Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBiolin Scientific
OriginFinland
ModelTheta Flow with 3D Topography Module
Instrument TypeBenchtop Video-Based Optical Contact Angle Analyzer
Contact Angle Range0–180°
Contact Angle Accuracy±0.01°
Contact Angle Resolution2592 × 2048 (5.3 MP)
Surface Tension Range0.01–2000 mN/m
Surface Tension Accuracy±0.01 mN/m
Sample Stage DimensionsUnlimited (L) × 100 mm (W) × 320 mm (D)
Max Sample SizeUnlimited (L) × 320 mm (W) × 22 mm (H)
Imaging Sensor5.3 MP CMOS, 2592 × 2048 pixels
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBiolin Scientific
OriginFinland
ModelTheta Lite
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Resolution0.01°
Contact Angle Accuracy±0.1° (standard), ±0.01° (high-precision mode)
Surface & Interfacial Tension Range0.01–2000 mN/m
Surface & Interfacial Tension Accuracy±0.1 mN/m (standard), ±0.01 mN/m (high-precision mode)
Camera Resolution1936 × 1216 pixels
Sample Stage Dimensions (L×W×H)495 × 130 × 310 mm
Max. Sample Weight Capacity5 kg
Image MagnificationFixed optical path with high-magnification telecentric lens system
Measurement ModesStatic CA, Advancing/Receding CA, Roll-off Angle, Surface Free Energy (Owens-Wendt, Wu, van Oss), Interfacial Tension, Batch Analysis, Roughness-Corrected CA, Single-Fiber CA
SoftwareOneAttension v4.x (FDA 21 CFR Part 11 compliant audit trail option available)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBiolin Scientific
OriginFinland
ModelTheta Flow Wafer
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Contact Angle Measurement RangeContact angle, surface tension, interfacial tension, surface free energy
Contact Angle Accuracy±0.1°
Sample Stage Sizes2", 3", 4", 5", 6", 8", 12" wafers
Image Resolution2592 × 2048 (5.3 MP)
Surface/Interfacial Tension Accuracy±0.1 mN/m (derived via pendant/sessile drop analysis)
Maximum Sample Diameter12-inch silicon wafer
Stage Load Capacity500 g
Automated FunctionsMotorized XYZ translation + programmable rotation (0–360°), four independent software-controlled dispensers with disposable tips
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBiolin Scientific
OriginFinland
ModelTheta Flow HPC High Pressure Chamber
Instrument TypeBenchtop Laboratory System
Contact Angle Range0.1–179.9°
Contact Angle Accuracy±0.1°
Contact Angle Resolution2592 × 2048 (5.3 MP)
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Accuracy±0.01 mN/m
Sample Stage DimensionsUnlimited × 100 mm × 320 mm
Maximum Sample Size765 mm × 230 mm × 435 mm
Stage Load Capacity29 kg
Imaging Sensor5.3 MP CMOS, 2592 × 2048 pixels
Pressure ControlAutomated via integrated precision pump
Temperature RangeAmbient to elevated temperatures (optional sub-ambient cooling available)
Chamber DesignPiston-driven high-pressure cell with corrosion-resistant wetted materials (e.g., Hastelloy C-276, sapphire windows)
Fluid HandlingDual-path intelligent injection valve for direct syringe-based dispensing and in-line cleaning without pump priming
Surface Activity PreservationPiston displacement maintains constant bulk-phase surfactant concentration during pressure ramping
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBiolin Scientific
OriginFinland
ModelTheta Flow
Instrument TypeBenchtop Dynamic Contact Angle Analyzer
Contact Angle Range0–180°
Surface/Interfacial Tension Range0.01–2000 mN/m
Contact Angle Accuracy±0.01°
Contact Angle Resolution2592 × 2048 (5.3 MP)
Imaging SystemUSB 3.0 Digital Camera with 8× Optical Zoom & High-Power Monochromatic LED Illumination
Sample Stage Dimensions765 mm × 230 mm × 435 mm (W × D × H)
Maximum Sample Weight29 kg
Environmental MonitoringIntegrated Temperature & Humidity Sensors
Software PlatformOneAttension v4.x with Audit Trail, CFR 21 Part 11 Compliance Options
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBiolin Scientific
OriginFinland
ModelTheta Flex
Instrument TypeVideo-Based Optical Contact Angle Analyzer
Contact Angle Measurement Range0–180°
Contact Angle Resolution0.01°
Contact Angle Accuracy±0.01°
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Accuracy±0.01 mN/m
Sample Stage Dimensions100 mm × 320 mm
Maximum Sample Size (L×W×H)763 × 230 × 435 mm
Stage Load Capacity26 kg
Imaging SystemUSB 3.0 Digital Camera with 8× Zoom, High-Intensity Monochromatic LED Illumination
Image Resolution1936 × 1216 (optional Theta Flow high-speed camera available)
ComplianceDesigned for GLP/GMP environments