| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | PlateSmart |
| Instrument Type | Benchtop Centrifuge |
| Centrifugation Category | Low-Speed Centrifuge |
| Maximum Speed | 2500 rpm |
| Maximum RCF | 650 × g |
| Speed Range | 500–2500 rpm |
| Capacity | 4 × 96-well microplates (ELISA plates) or 2 × deep-well plates or 2 × PCR plates |
| Rotor Type | Horizontal fixed-angle rotor |
| Drive System | High-torque direct-drive disc motor |
| Timer Range | 1–99 min + continuous mode |
| Power Supply | 110–230 V, 50 Hz, 150 W |
| Noise Level | <60 dB(A) |
| Dimensions (W×D×H) | 310 × 380 × 300 mm |
| Net Weight | 12 kg |
| Temperature Rise | <12 °C during operation |
| Safety Features | Interlocked lid with automatic rotor stop |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-1 Pro |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–17,500 rpm |
| Max RCF | 23,300 × g |
| Max Capacity | 12 × 5 mL (angle rotor) |
| Dimensions (W×D×H) | 295 × 227 × 395 mm |
| Noise Level | ≤58 dB(A) at max speed |
| Acceleration/Deceleration | 10-step programmable ramp control |
| Programmable Methods | 100 user-defined protocols |
| Display | 5-inch capacitive touch screen |
| Compliance | CE, ISO 13485 (manufacturing), IEC 61010-1 safety standard |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | MPC2000 PRO |
| Instrument Type | Benchtop Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Max Capacity | 6 × cell culture plates / microplates / skirted PCR plates |
| Max Speed | 4500 rpm |
| Max RCF | 2860 × g |
| Dimensions (W×H×D) | 384 × 288 × 480 mm |
| Power Supply | 220 V / 50 Hz, 750 W |
| Temperature Range | Ambient +5 °C to 45 °C |
| Speed Range | 300–4500 rpm |
| Timer Range | 1 s–99 min 59 s or 1 min–99 h 59 min |
| Acceleration Steps | 9 levels |
| Deceleration Steps | 10 levels |
| Display | 3.5-inch LCD screen |
| Net Weight | 35 kg |
| Brand | DHS |
|---|---|
| Origin | Beijing, China |
| Model | NX-1R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Cooling Function | Refrigerated |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Separation Class | Biomacromolecules |
| Maximum Capacity | 12 × 5 mL |
| Maximum Speed | 17,500 rpm |
| Maximum RCF | 23,300 × g |
| Dimensions (W × D × H) | 270 × 355 × 550 mm |
| Noise Level | <50 dB(A) at Max Speed |
| Minimum Temperature | ≤−20 °C |
| Cooling Rate | From RT to 0 °C in <10 min |
| Operating Temp Stability | Maintains ≤4 °C during high-speed runs |
| Brand | DHS |
|---|---|
| Origin | Beijing, China |
| Model | NX-1 |
| Centrifuge Type | Benchtop High-Speed Centrifuge |
| Rotor Type | Fixed-Angle Rotors |
| Max Speed | 17500 rpm |
| Max RCF | 23300 × g |
| Max Capacity | 12 × 5.0 mL |
| Dimensions (W×D×H) | 235 × 400 × 270 mm |
| Net Weight | 16 kg |
| Noise Level | <60 dB(A) at Max Speed |
| Temperature Rise | <10 °C after 20 min at Max Speed |
| Speed Range | 300–17500 rpm (100 rpm increments) |
| Time Setting | 1 s–99 min, Continuous, Soft-Stop, Pulse Mode |
| Power Supply | 220 V / 50 Hz |
| Rotor Options | 12×1.5/2.0 mL, 24×1.5/2.0 mL, 12×5.0 mL, 18×2.0 mL spin columns, 8×8×0.2 mL PCR strip rotor |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | CellSmart |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2770 × g |
| Max Capacity | 6 × 50 mL |
| Rotor Configuration | Horizontal (swing-out) rotor system |
| Sample Compatibility | Cells, bacteria, blood tubes, microcentrifuge tubes, cryovials |
| Dimensions (W×D×H) | 288 × 384 × 480 mm |
| Construction | All-metal housing, stainless-steel chamber |
| Drive System | Brushless DC motor |
| Display | High-brightness LED, rpm/rcf toggle function |
| Control | Microprocessor-based, instant spin button |
| Noise Level | ≤55 dB(A) |
| Thermal Management | Optimized airflow ducting for minimal temperature rise |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-2R |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Speed Range | 300–18,500 rpm (100 rpm increments) |
| Max. Capacity | 4 × 100 mL |
| Max. Speed | 18,500 rpm |
| Max. RCF | 26,000 × g |
| Temperature Range | –20 °C to 40 °C (1 °C increments) |
| Timer | 1 s–59 s–1 min–99 min, continuous mode, soft spin |
| Rotor Recognition | Automatic |
| Noise Level | ≤65 dB(A) |
| Dimensions (W×D×H) | 360 × 330 × 630 mm |
| Net Weight | 46 kg |
| Power Supply | 220 V / 50 Hz |
| Safety Features | Electronic door lock, reinforced metal housing, thick-walled rotor chamber, overtemperature shutdown, auto-rotor ID |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | Plate-Smart |
| Instrument Type | Benchtop Plate Centrifuge |
| Max Speed | 2500 rpm |
| Max RCF | 650 × g |
| Capacity | 4 × 96-well microplates, or 2 × deep-well plates, or 2 × PCR plates |
| Drive System | High-torque disc motor, direct drive |
| Control | Microprocessor-based, digital time/speed display |
| Timer Range | 1–99 min + continuous mode |
| Speed Range | 500–2500 rpm |
| Power Supply | 110–230 V, 50 Hz, 150 W |
| Max Temperature Rise | <12 °C |
| Dimensions (W×D×H) | 310 × 380 × 300 mm |
| Net Weight | 12 kg |
| Safety | Automatic rotor stop upon lid opening, mechanical safety interlock |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-4R Pro |
| Instrument Type | Benchtop Centrifuge |
| Cooling Function | Refrigerated |
| Rotor Configuration | Horizontal (Swinging-Bucket) & Fixed-Angle Options |
| Maximum Capacity | 4 × 1000 mL |
| Maximum Speed | 21,000 rpm |
| Maximum RCF | 33,500 × g |
| Temperature Range | –20 °C to +40 °C |
| Dimensions (W × H × D) | 855 × 395 × 730 mm |
| Drive System | Brushless DC Motor with PWM Speed Control |
| Acceleration/Deceleration Profiles | 9-step ramp, 10-step brake |
| Rotor Recognition | Automatic electronic identification |
| Safety Features | Electronic imbalance detection, overspeed protection, overtemperature cutoff, door interlock |
| Display | 10-inch full-color capacitive touchscreen |
| Program Storage | 100 user-defined multi-segment protocols (up to 10 steps per program) |
| Rotor Material | Carbon-fiber fixed-angle rotor (6 × 250 mL, max. RCF 18,530 × g) |
| Refrigeration System | CFC-free imported compressor |
| Compliance | Designed for GLP-compliant workflows |
| Brand | DHS |
|---|---|
| Model | NX-3R Pro |
| Type | Refrigerated Benchtop Centrifuge |
| Max Speed | 21,000 rpm |
| Max RCF | 33,500 × g |
| Max Capacity | 6 × 250 mL |
| Temperature Range | −20 °C to 40 °C (1 °C increments) |
| Acceleration | 9 levels |
| Deceleration | 10 levels |
| Programmable Methods | 100 stored protocols |
| Rotor Recognition | Automatic |
| Display | 7-inch color touchscreen |
| Dimensions (W × D × H) | 470 × 740 × 325 mm |
| Net Weight | 64 kg |
| Power Supply | 220 V / 50 Hz |
| Safety Cutoff | Thermal shutdown at >45 °C |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-3 |
| Type | Benchtop Centrifuge |
| Category | High-Speed Centrifuge (10,000–30,000 rpm range) |
| Max Speed | 15,000 rpm |
| Max RCF | 25,500 × g |
| Max Capacity | 4 × 250 mL |
| Dimensions | 530 × 417 × 335 mm |
| Power Supply | 220 V / 50 Hz, 750 W |
| Weight | 40 kg |
| Temperature Rise | <12 °C |
| Speed Range | 300–15,000 rpm (increment: 100 rpm) |
| Timer Range | 1–99 min or continuous (increment: 1 min) |
| Program Storage | 9 user-defined protocols |
| Rotor Recognition | Automatic |
| Display | High-brightness LED |
| Drive System | Frequency-controlled brushless motor |
| Control System | Microprocessor-based |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | HR220 / HB220 |
| Type | Benchtop Microcentrifuge |
| Max Speed | 6500 rpm |
| Max RCF | 2000 × g |
| Capacity | 6 × 1.5/2.0 mL or 2 × 8 × 0.2 mL PCR tubes |
| Dimensions | 130 × 120 × 140 mm |
| Weight | 494 g |
| Power Supply | 220 V, 50 Hz |
| Compliance | CE-marked for laboratory use under IEC 61010-1 |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-3R |
| Instrument Type | Benchtop Centrifuge |
| Category | High-Speed Refrigerated Centrifuge (10,000–30,000 rpm) |
| Max. Capacity | 6 × 250 mL |
| Max. Speed | 18,500 rpm |
| Max. RCF | 26,500 × g |
| Temperature Range | −20 °C to +40 °C (1 °C increment) |
| Dimensions (W×H×D) | 450 × 325 × 720 mm |
| Net Weight | 68 kg |
| Rotor Recognition | Automatic |
| Programmable Memory | 10 user-defined protocols |
| Speed Range | 300–18,500 rpm (100 rpm increment) |
| Time Setting | 1 s–99 min (1 s or 1 min increment), continuous mode, soft-start/soft-stop |
| Power Supply | 220 V / 50 Hz |
| Brand | DHS |
|---|---|
| Origin | Beijing, China |
| Model | MPC2000 |
| Instrument Type | Benchtop Centrifuge |
| Centrifugation Category | Low-Speed Centrifuge (≤4500 rpm) |
| Rotor Configuration | Horizontal Swing-Out Rotor |
| Maximum Capacity | 6 × 96-well ELISA plates / 2 × deep-well plates / 2 × PCR plates (with adapter) |
| Max Speed | 4500 rpm |
| Max RCF | 2860 × g |
| Dimensions (L×W×H) | 280 × 380 × 480 mm |
| Noise Level | <56 dB(A) |
| Motor | Brushless DC Direct Drive |
| Speed Range | 500–4500 rpm |
| Timer Range | 1–99 min + continuous mode |
| Power Supply | 220 V / 50 Hz / 350 W |
| Weight | 35 kg |
| Temperature Rise | <10 °C during operation |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Instrument Type | Benchtop Centrifuge |
| Category | High-Speed Refrigerated Centrifuge (10,000–30,000 rpm range) |
| Function | Refrigerated Centrifugation |
| Configuration | Fixed-Angle Rotor System |
| Target Applications | Biomolecular Separation |
| Maximum Capacity | 24 × 2 mL |
| Maximum Speed | 17,500 rpm |
| Maximum RCF | 23,300 × g |
| Dimensions (W × D × H) | 325 × 295 × 540 mm |
| Temperature Range | −20 °C to +40 °C |
| Acceleration/Deceleration Steps | 9-step acceleration, 10-step deceleration |
| Rotor Options | Five interchangeable fixed-angle rotors (12 × 1.5/2.0 mL, 24 × 1.5/2.0 mL, 12 × 5.0 mL, 18 × 2.0 mL spin-column, 8 × 8 × 0.2 mL PCR strip) |
| Speed Setting Range | 300–17,500 rpm |
| Time Setting | 1 s–99 min 59 s or 1 min–99 h 59 min |
| Display | 5-inch full-color capacitive touchscreen |
| Stored Programs | 100 user-defined protocols |
| Program Structure | Up to 10 segments per program (minimum 1) |
| Data Logging | Graphical run curves and chronological history logs with timestamped metadata |