| Key | Origin: Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LD8000 |
| Price | USD 24,500 (FOB) |
| Detection Principle | Plasma Emission Spectroscopy (PES) |
| Range Options | 0–1 ppm (10 ppb resolution) |
| Repeatability | <1% FS |
| Accuracy | ±1% FS |
| Sample Flow | 15–200 sccm |
| Flow Accuracy | ±1% FS (0–200 sccm) |
| Operating Pressure | 4–100 PSIG (28–689 kPAG), optional down to 1 PSIG (7 kPAG) |
| Operating Temperature | 10–45 °C |
| Power | 115/220 VAC, 50–60 Hz |
| Max Power Consumption | 40 W |
| Drift | <±1% over 24 h |
| Weight | 13 kg (29 lbs) |
| Display | 5.6″ TFT Touchscreen LCD |
| Outputs | 4–20 mA (isolated), LAN/Web interface, 3-channel analog range output, system status output, calibration output |
| Communication | RS-232/422/485, Profibus optional |
| Gas Connections | 1/8″ Swagelok (sample, vent, span gas) |
| Calibration Gases | Zero: LDP1000 getter-purified Ar |
| Span | 8.0–9.5 ppm N₂ in Ar |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CHN828 |
| Pricing | Upon Request |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Imported Instrument |
| Model | CHNS628 |
| Price | Upon Request |
| Carbon Range | 0.02–175 mg C |
| Hydrogen Range | 0.1–12 mg H |
| Nitrogen Range | 0.04–50 mg N |
| Sulfur Range | 0.05–50 mg S |
| Precision | C: ±0.01 mg or 0.5% RSD (whichever greater), H: ±0.05 mg or 1.0% RSD, N/S: ±0.02 mg or 0.5% RSD |
| Sample Mass | CHN mode ≤250 mg (typ. 100 mg), CN mode ≤500 mg (typ. 250 mg), FP/N mode ≤750 mg (typ. 500 mg) |
| Readability | 0.0001% |
| Analysis Time | 4.5 min |
| Detection | CO₂/H₂O via NDIR |
| Carrier Gas | He (99.99%, 35 psi ±10%) |
| Combustion Gas | O₂ (99.99%, 35 psi ±10%) |
| Drive Air | Oil-free, dry compressed air (40 psi ±10%) |
| Furnace | Dual-zone resistive furnace (primary + secondary), up to 1050 °C |
| Autosampler | 30-position (expandable to 120) |
| Ambient | 15–35 °C, 20–80% RH non-condensing |
| Dimensions | 81 × 70 × 76 cm (H×W×D) |
| Weight | 124 kg (operational), 147 kg (shipping) |
| Power | 230 V AC ±10%, 50/60 Hz, single-phase, 12 A, 4000 BTU/hr |
| Software | LECO Windows-based application with audit trail, method management, and GLP-compliant reporting |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CS600 |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | High-Frequency Induction Furnace |
| Measurement Range | Not Specified |
| Sensitivity | Not Specified |
| Precision | Not Specified |
| Analysis Time | Not Specified |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Imported Instrument |
| Model | CS744 |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace |
| Analysis Time | 40 s |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CS844 |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace |
| Carbon/Sulfur Range | 0.6 ppm – 6 wt% |
| Analysis Time | < 50 seconds |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DH603 |
| Instrument Type | Hydrogen Analyzer |
| Measurement Principle | Thermal Extraction with Solid-State Detection |
| Temperature Range | Ambient to 1100 °C |
| Sample Form | Solid Metallic Specimens (Ferrous Alloys, Weld Metals, Castings, Forgings) |
| Optional Accessories | Diffusible Hydrogen Sampler, Residual Hydrogen Sampler, Vacuum Sampling Probes for Molten Metal |
| Calibration Method | Standardless Gas Calibration via Internal Reference Signal Stabilization |
| Compliance | Designed to Support ASTM E1442, ISO 3690, AWS A4.3, and EN ISO 17025–accredited laboratory workflows |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | FP628 |
| Instrument Principle | Dumas Combustion Method |
| Analysis Time | 4.5 min per sample |
| Nitrogen Range | 0.04–50 mg absolute |
| Precision | ±0.02 mg or 0.5% RSD (whichever is greater) |
| Sample Mass | up to 750 mg (typical 500 mg) |
| Readability | 0.0001% w/w |
| Detector | Thermal Conductivity (TC) Cell |
| Carrier Gas | Helium (99.99%, 35 psi ±10%) |
| Combustion Gas | Oxygen (99.99%, 35 psi ±10%) |
| Assist Gas | Oil-free, dry compressed air (40 psi ±10%) |
| Furnace Temp | Primary furnace up to 950 °C, secondary furnace up to 1050 °C |
| Autosampler | 30-position (expandable to 120 via stacking) |
| Dimensions | 81 × 70 × 76 cm (H×W×D) |
| Weight | 124 kg (net), 147 kg (shipping) |
| Power | 230 V AC ±10%, 50/60 Hz, single-phase, 12 A, 4000 BTU/hr cooling requirement |
| Compliance | ASTM D515, ISO 14891, AOAC 992.15, USP <282>, FDA 21 CFR Part 11 ready (with optional audit trail module) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | H836EN |
| Instrument Type | Hydrogen Analyzer |
| Detection Range | 0.01–100 ppm (w/w) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Model | O836Si |
| Instrument Type | Oxygen Analyzer |
| Detection Range | 0.03–150 ppm |
| Analytical Precision | ±0.015 ppm |
| Analysis Time | 110 s |
| Detector | Non-Dispersive Solid-State Infrared (NDIR) |
| Furnace | Programmable Pulse Electrode Furnace with Power & Current Control |
| Sample Introduction | Flip-Action Loading Port |
| Output Units | ppma and ppmw |
| Peak Separation Method | Surface Oxide vs. Bulk Oxide Quantification |
| Blank Level | Ultra-Low Background |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ON736 |
| Analysis Time | 85 s |
| Detection Principle | Inert Gas Fusion Coupled with Non-Dispersive Infrared (NDIR) and Thermal Conductivity Detection (TCD) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ONH836 |
| Analysis Range | 0.00005–50 mg |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Method | Inert Gas Fusion (Graphite Crucible, Pulse Heating) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Hydrogen Analyzer |
| Model | RHEN602 |
| Detection Range | 0.05 ppm – 500 ppm |
| Precision | < 0.02 ppm |
| Sample Capacity | Up to 6 g |
| Furnace Type | Programmable Graphite Electrode Furnace |
| Calibration Options | Certified Reference Materials (CRMs) and Standard Gases |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SC832 |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | Resistance Furnace |
| Measurement Range | C: 0.0175 mg to 200 mg |
| S | 0.0035 mg to 98 mg |
| Analysis Time | < 100 s |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TC-500 |
| Instrument Type | Oxygen and Nitrogen Analyzer |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | Dumas Combustion-Based Elemental Analyzer |
| Application Focus | Total Nitrogen, Protein, Carbon, Sulfur, and/or Oxygen Determination in Organic and Inorganic Matrices |
| Model Family | TruSpec® Micro, TruSpec® Soil, TruSpec® CHN, TruSpec® CS, TruSpec® CNS (Configurable per application) |
| Compliance | ASTM D5142, D6347/D6347M, D7329, ISO 13878, AOAC 992.15, 993.13, 2001.11, USP <467>, EPA Method 440.1, EN ISO 13878 |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KDN-1 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Measurement Range | 0.1–240 mg N |
| Nitrogen Recovery Rate | ≥99.5% |
| Sample Weight Capacity | ≤6 g (solid) / ≤16 mL (liquid) |
| Distillation Speed | 3–6 min/sample |
| Adjustable Distillation Time | Up to 60 min |
| Cooling Water Consumption | 1.5 L/min |
| Operating Modes | Automatic & Manual |
| Display | 4.3-inch high-resolution color LCD |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Rated Power | 1.3 kW |
| Dimensions (W×D×H) | 400 × 385 × 735 mm |
| Net Weight | 30 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Leici KDN-1 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1 mg – 240 mg N |
| Steam Distillation Time | Programmable up to 60 min |
| Sample Weight Capacity | ≤6 g (solid), ≤16 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 1.3 kW |
| Dimensions (L×W×H) | 400 mm × 385 mm × 735 mm |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | Light 915 |
| Instrument Type | Portable |
| Detection Principle | Zeeman Atomic Absorption Spectroscopy with High-Frequency Modulated Polarized Light (ZAAS-HFM) |
| Wavelength | 254 nm |
| Detection Limit | <0.1 µg/m³ |
| Operating Duration | Up to 12 h on rechargeable battery |
| Dynamic Range | 5 orders of magnitude |
| Data Storage | Internal memory with USB and Bluetooth export |
| Regulatory Status | Listed on U.S. EPA Emergency Response Equipment List |
| Compliance | Designed for compliance with OSHA PEL, ACGIH TLV, and ISO 6879 for elemental mercury vapor monitoring |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Lumazote |
| Pricing | Available Upon Request |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | Light 915 |
| Instrument Type | Portable |
| Measurement Principle | Zeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM) |
| Detection Limit | 100 ng/m³ |
| Repeatability | ±1% RSD |
| Linearity Error | ±1% |
| Measurement Range | 0.1–3000 µg/m³ |
| Air Pump Flow Rate | 10 L/min |
| Analysis Time | Real-time |
| Dimensions | 290 × 210 × 110 mm |
| Weight | 3.3 kg |
| Power Supply | Internal 12 V DC rechargeable battery (12 h operation) / External 110–240 V AC, 50/60 Hz |
| Power Consumption | 20 W |
| Data Storage | Internal memory with USB and Bluetooth connectivity |
| Compliance | EPA Emergency Response Equipment List, ASTM D6784-22 (for mercury in air), ISO 6978-1:2003 (natural gas—mercury determination) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | LS-915 |
| Instrument Type | Benchtop Laboratory System |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | 1 pg Hg |
| Repeatability | ≤1% RSD |
| Linearity Error | ≤2% |
| Sample Capacity | 75 positions |
| Solid Sample Mass | ≥1000 mg |
| Liquid Sample Volume | ≥500 µL |
| Robotic Architecture | Cartesian XYZ Coordinate System |
| Crucible Material | High-Purity Quartz (operable up to >1000 °C) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | Pyro-915+ |
| Instrument Type | Portable |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Zeeman Background Correction |
| Detection Limit | 0.05 ng/mL (liquid) / 0.05 µg/kg (solid) |
| Repeatability | ±2% RSD |
| Linearity Error | ±1% |
| Sample Throughput | <2 min per sample |
| Operating Temperature Range | Programmable up to 950 °C |
| Air Monitoring LOD | 0.5 ng/m³ (10-s response) / 2 ng/m³ (1-s response) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 700 W |
| Weight | 17.5 kg |
| Dimensions (Controller) | 400 × 280 × 135 mm |
| Dimensions (Furnace) | 430 × 340 × 135 mm |
| Continuous Operation | Up to 8 h |
| Carrier Gas Flow | 1.0–3.0 L/min |
| Sample Mass Range | 10–1500 mg |
| Upper Detection Limit | 200 mg/kg (based on 20 mg sample) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915AM |
| Instrument Type | Online Analyzer |
| Measurement Principle | Zeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM) |
| Detection Limit | 0.5 ng/m³ |
| Repeatability | ±1% |
| Linearity Error | ±2% |
| Gas Flow Rate | 3–10 L/min |
| Response Time | 10–300 s |
| Range I | 0.5–2000 ng/m³ |
| Range II | 100–400,000 ng/m³ |
| Operating Temperature | −20 to +50 °C |
| Pressure Range | 84–106.7 kPa |
| Relative Humidity | <99% at 35 °C |
| Power Supply | 240 VAC, 50/60 Hz |
| Power Consumption | 120 W |
| Dimensions | 600 × 480 × 220 mm |
| Weight | 19 kg |
| Communication Interfaces | RS-232, Dual USB, LAN, Isolated 4–20 mA Output |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RA-915AMNG |
| Instrument Type | Online Analyzer |
| Principle | Zeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM) |
| Detection Limit | 0.5 ng/m³ |
| Repeatability | ±1% |
| Linearity Error | ±1% |
| Measurement Range | 0–2000 ng/m³ (configurable multi-range options available) |
| Reporting Interval | ≥2 s (user-definable) |
| Benzene Correction | Fully Automatic |
| Zero Drift Correction | User-selectable (recommended every 60 min) |
| Span Drift Correction | User-selectable (recommended every 3 h) |
| Calibration | Fully Automated (calibration source ≈12,000 ng/m³ Hg) |
| Sample Flow Rate | 7–10 L/min |
| Communication Protocol | Standard Bavarian Protocol (customizable upon request) |
| Status Outputs | SERVICE (zero/calibration mode), FAILURE, MEASURE (Bavarian) |
| Operating Temperature | 14–40 °C |
| Atmospheric Pressure | 84–106.7 kPa |
| Relative Humidity | <99% at 35 °C |
| Power Supply | 220–240 VAC, 50 Hz |
| Dimensions | 600 × 480 × 220 mm |
| Weight | 19 kg |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915F |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Thermal Decomposition |
| Detection Limit | 0.005 ng Hg |
| Repeatability | ±1% RSD |
| Linearity Error | ±1% |
| Detection Range | 5 orders of magnitude |
| Sample Throughput | 1–5 min per analysis |
| Power Supply | 220 VAC, 50 Hz (with optional DC/vehicle power adapter) |
| Dimensions (Analyzer Unit) | 300 × 260 × 130 mm |
| Weight (Analyzer Unit) | 4.0 kg |
| Dimensions (Thermal Decomposer Module) | 350 × 260 × 120 mm |
| Weight (Thermal Decomposer Module) | 7.5 kg |
| Dimensions (Power Supply Unit) | 380 × 260 × 130 mm |
| Weight (Power Supply Unit) | 10.0 kg |
| Sample Mass Range | 10–500 mg |
| Liquid Detection Limit | 0.5 µg/L |
| Solid Upper Quantitation Limit | 200 mg/kg |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915Lab |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Repeatability | <1.5% RSD |
| Linearity Error | ±5% |
| Sample Throughput | Up to 45 samples unattended |
| Analysis Time | ≤3 minutes per sample |
| Linear Range | 0–2,000,000 µg/kg (ppb–ppm equivalent across matrices) |
| Detection Capability | Sub-ng absolute sensitivity (matrix-dependent) |
| Compliance | EPA Method 7473, EPA 1631, EPA 30B, EPA SW-846 |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915M Series |
| Instrument Type | Portable |
| Principle | Zeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM) |
| Detection Limit | 0.5 ng/m³ (10 s), 2 ng/m³ (1 s) |
| Repeatability | <2% RSD |
| Linearity Error | ±5% |
| Measurement Range | 0.5–200,000 ng/m³ |
| Zero Signal SD | <2 ng/m³ |
| 5-min Zero Drift | <2 ng/m³ |
| Warm-up Time | <20 min |
| Air Pump Flow Rate | >10 L/min |
| Power Supply | Internal 12 V DC battery (8 h continuous operation) or 110/220 V AC, 50/60 Hz |
| Dimensions | 460 × 110 × 220 mm |
| Weight | 7 kg |
| Power Consumption | 40 W |
| Compliance | EPA Method 1631, EPA SW-846 7473 & 30B, ASTM D7622-10, EN 1483 / 13806 / 15852, GB 7468-87 |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915S |
| Instrument Type | Portable |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Zeeman-effect background correction |
| Detection Limit | 0.01 µg/kg |
| Repeatability | ≤1% RSD |
| Linearity Error | ≤1% |
| Sample Introduction | Direct thermal decomposition (10–1500 mg solid/liquid) |
| Analysis Time | 1–2 min per sample |
| Dynamic Range | 5 orders of magnitude |
| Wavelength | 254 nm (Hg resonance line) |
| Power Supply | 198–242 VAC, 50 ± 1 Hz |
| Dimensions (Detector Unit) | 470 × 210 × 110 mm |
| Integrated Air Pump | Yes |
| Onboard Calibration | Certified Hg standard traceable to NIST |