Environmental Monitoring Instruments
Filter
Showing 7411–7440 of 9029 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Fisher 8000 Series TOC Analyzer |
| Detection Principle | High-Resolution Gas Chromatography Coupled with Flame Ionization Detector (FID) or Pulsed Discharge Helium Ionization Detector (PDHID) |
| Analyte Range | CH₄, NMHC, Benzene, Toluene, Xylenes (o/m/p), Ethylbenzene, Trimethylbenzenes, Styrene, Ethyl Acetate, Butyl Acetate, Tetrahydrofuran (THF), Isopropanol (IPA), 1-Propanol, Acetone, Hexane, 2-Butanone, Propylene Glycol Monomethyl Ether (PGME), Propylene Glycol Monomethyl Ether Acetate (PGMEA), Cyclopentane, Cyclohexanol, Methylene Chloride, Chloroform, 1,2-Dichloroethane, 1,2-Dichloropropane, and other volatile organic compounds (VOCs) |
| Measurement Cycle | 0–60 min (user-configurable per method) |
| Limit of Detection (LOD) | As low as sub-ppt (≤0.1 pg C) for selected analytes with PDHID |
| Zero Noise | ≤0.04 ppb (as carbon equivalent) |
| Repeatability (RSD) | ≤5% at 10× LOD |
| Computing Platform | Embedded industrial PC — Intel dual-core processor, 4 GB RAM, ≥64 GB SSD (Windows IoT Enterprise) |
| Display | 12-inch full-color industrial capacitive touchscreen |
| Control Software | Onboard system control suite enabling automated sampling, chromatographic analysis, periodic calibration verification, system suitability testing, column conditioning, and unattended 7×24 operation |
| Data Export Formats | MS Excel (.xlsx), CSV, TXT |
| Real-time Status Monitoring | Dynamic graphical interface showing valve positions, oven temperature, detector status, pressure/flow profiles, and alarm history |
| Diagnostics | Comprehensive self-diagnostic routines with event-logged fault codes and predictive maintenance alerts |
| Chromatographic Data Processing | Batch processing support |
| Mechanical Format | 19-inch rack-mountable chassis |
| Dimensions (L×W×H) | 667 mm × 482.5 mm × 355 mm |
| Rack Units | 8U |
| Weight | 32 kg |
| Power Supply | 220 VAC ±10%, 50–60 Hz, max. 500 W |
| Operating Environment | 0 °C to 40 °C, 5–85% RH non-condensing |
| Communication Interfaces | Dual Ethernet (10/100/1000BASE-T), RS-232, RS-485, 3× USB 2.0, VGA output |
| Communication Protocols | Modbus TCP (standard), Modbus RTU over RS-485 (standard), optional analog outputs (0–1 V, 4–20 mA) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Model | Aeke SO3 |
| Measurement Principle | Quantum Cascade Laser Absorption Spectroscopy (QCLAS) |
| Calibration Method | On-site SO₂-to-SO₃ conversion via integrated catalytic converter |
| Sampling Configuration | Dilution extractive probe with inertial filter |
| Installation Flexibility | Hot/wet sampling capable |
| Data Integration | Native compatibility with DAS and DCS platforms |
| Regulatory Alignment | Designed to support EPA Method 8/204 compliance, ISO 12039, and EU EN 15267-3 requirements |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11–ready data logging |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | AnalogPlus Conductivity Electrode |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AQ4BW1 |
| Instrument Type | Laboratory-Based |
| Biological Indicator | Bioluminescent Bacteria |
| Detection Principle | Bioluminescence Inhibition Assay |
| Compliance | ISO 11348-3:2022 |
| Measurement Range | 0–65535 RLU |
| Spectral Response | 320–1000 nm |
| Detection Time | As low as 5 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 10–90% RH (at 25 °C) |
| Battery Life | ≥8 h continuous operation |
| Weight | ~258 g (including batteries) |
| Dimensions | 202 × 78 × 30 mm |
| Power Supply | 3 V DC (AA batteries) |
| Data Interface | USB |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AquaChlor |
| Pricing | Upon Request |
| Measurement Principle | Amperometric Electrode (Gold Cathode / Silver Anode with Teflon Membrane) |
| Range | 0–5 ppm and 0–20 ppm |
| Resolution | 0.005 ppm |
| Accuracy | ±2% of reading or ±10 ppb, whichever is greater |
| Response Time (t₉₀) | 90 seconds |
| Units | ppm (Cl₂), °C / °F |
| Calibration | Single-point air calibration |
| Compensation | Automatic temperature compensation |
| Operating Temperature | 0–45 °C |
| Max Pressure | 15 PSIG (1.03 bar) at 40 °C |
| Flow Rate | 200–250 mL/min |
| Housing Material | Noryl |
| Electrode Materials | Gold cathode, silver anode |
| Selective Membrane | PTFE (Teflon®) |
| Communication Protocols | Modbus RTU, DeviceNet, USB, RS-232, CANopen |
| Data Interface | AV38 Local Display Unit or DataStick Network-Ready Module |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Aquakem 600 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Principle | Discrete Photometric Analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Aquakem200 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Speed | Up to 180 tests/hour |
| Sample Positions | 84 |
| Refrigerated Reagent Positions | 35 |
| Maximum Reagents per Test | 4 |
| Wavelength Range | 340–880 nm |
| Barcode Reader | Integrated |
| Sample Dilution | Auto pre-dilution and auto re-dilution |
| Cadmium Reduction Module | Optional (for nitrate analysis) |
| System Architecture | Open-platform, user-definable methods, reagents, and protocols |
| Probe Function | Dual-purpose pipetting probe with integrated mixing capability |
| Wash System | Automatic internal/external probe washing |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Aquakem250 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Speed | 250 tests/hour |
| Sample Positions | 84 |
| Refrigerated Reagent Positions | 35 |
| Wavelength Range | 340–880 nm |
| Maximum Reagents per Test | 4 |
| Cadmium Reduction Module | Optional |
| Barcode Reader | Integrated |
| Sample/Reagent Dispensing | Fully Automated with Internal/External Tip Washing |
| Dilution Capability | Auto Primary & Secondary Dilution |
| Stirring | Independent Stir Bars with Dedicated Wash Station |
| Reagent Flexibility | User-Defined Methods and Custom Reagent Preparation Supported |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | DO DataStick |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | Ozone DataStick |
| Instrument Category | Online Analyzer |
| Measurement Principle | Polarographic Electrochemical Probe (Clark-type) |
| Range | 0–10 ppm |
| Accuracy | ±2% of reading |
| Resolution | 0.01 ppm |
| Response Time | t₉₀ ≤ 90 s |
| Calibration | Single-point air calibration |
| Compensation | Automatic temperature, atmospheric pressure, and salinity compensation |
| Operating Temperature | –5 to 50 °C |
| Max Pressure | 65 PSIG (4.5 bar) at 50 °C |
| Max Flow Rate | 10 ft/s |
| Housing Material | PEEK |
| Electrode System | Triple-electrode (Au cathode, Ag anode, Ag reference electrode) |
| Oxygen-permeable Membrane | PFA-coated Teflon |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Industrial-Grade Water Quality Sensor Interface Platform |
| Model | AquaSensors DataStick |
| Communication Protocols | RS-232 (ASCII), Modbus RTU, Modbus RS-232, USB, DeviceNet, Ethernet, CANopen |
| Power Input | 10–36 V DC |
| Embedded Calibration Memory | Yes |
| Integrated Temperature Sensor | Yes |
| Compliance | CE, RoHS, IP68-rated housing (sensor head) |
| Software Compatibility | Thermo Fisher AquaLink Suite (v4.2+), third-party SCADA and PLC systems |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AquaSensors SST |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | BSB/BOD-OxiDirect |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Manometric (Pressure-Difference) Method |
| Measurement Range | 0–4000 mg/L |
| Detection Limit | 0.01 mg/L |
| Accuracy | ±0.5% of reading |
| Measurement Duration | Real-time, programmable incubation (1–28 days) |
| Repeatability | ±3% RSD |
| Sample Capacity | 6 independent channels |
| Display | Full-color LCD with real-time BOD trend graph and numeric mg/L readout |
| Data Storage | Internal memory with Bluetooth, USB 2.0, and SD card export |
| Environmental Compliance | Mercury-free operation, ISO 5815-1:2019 compliant methodology |
| Stirring System | Low-profile permanent-magnet stirrer with centering assurance |
| Accessories Included | Six 60-mL BOD amber glass bottles, six microprocessor-integrated pressure sensors, KOH absorbent pads, nitrification inhibitor (allylthiourea), 157 mL & 428 mL overflow calibration flasks, power supply, data cable, user manual, warranty card |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Chlorine XP |
| Instrument Type | Online Analyzer |
| Measurement Principle | DPD Spectrophotometry |
| Measured Parameters | Free Chlorine, Total Chlorine, Combined Chlorine |
| Range | 0.01–10 ppm |
| Accuracy | ±3% of reading |
| Repeatability | ±5% |
| Resolution | 0.01 ppm |
| Detection Limit | 0.01 ppm |
| Reagent Consumption | 0.03 mL per analysis |
| Reagent Shelf Life | 24 months (unopened) |
| Environmental Rating | IP65 (NEMA 4) |
| Communication Interface | RS-485 |
| Certifications | EPA Compliant, CSA Certified, ISO 9001 Certified |
| Operating Temperature Range | Supports sample temperatures down to 4 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Chlorine XP |
| Instrument Type | Online Analyzer |
| Measurement Principle | DPD Colorimetric Spectrophotometry |
| Measured Parameters | Free Chlorine, Total Chlorine, Combined Chlorine |
| Range | 0.01–10 ppm |
| Accuracy | ±3% of reading |
| Repeatability | ±5% |
| Resolution | 0.01 ppm |
| Detection Limit | 0.01 ppm |
| Reagent Consumption | 0.03 mL per analysis |
| Calibration | Automatic blank calibration prior to each measurement |
| Light Source Management | Auto-adjusted LED intensity for extended lifetime |
| Cell Cleaning | Integrated automatic cuvette cleaning cycle |
| Enclosure Rating | IP65 (NEMA 4) |
| Communication Interface | RS-485 |
| Certifications | EPA Compliant, CSA Certified, ISO 9001 Certified |
| Reagent Shelf Life | 24 months (unopened), 60 days (in instrument) |
| Operating Temperature Range | Compatible with sample temperatures as low as 4°C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | EPD MK2 |
| Instrument Category | Dose/Dose Rate Meter |
| Form Factor | Portable |
| Measured Radiation Types | X-ray, γ-ray, and β-particle radiation |
| Detector Type | Multi-stage solid-state detector |
| Measurement Quantities | Ambient dose equivalent H*(10), personal dose equivalent Hp(10) (deep/body), and Hp(0.07) (shallow/skin) |
| Compliance Standards | IEC 61283, IEC 61526, ANSI N13.11, ANSI N13.27, ANSI N42.20 |
| Data Retention | 10 years without battery power |
| Power Supply | Two AA 1.5 V alkaline batteries (8 weeks continuous operation) or one 3.6 V lithium battery (5 months continuous operation) |
| Communication Interface | High-speed infrared (IR) port |
| Alarm Capability | Configurable dose and dose rate thresholds with audible alert |
| Memory Security | Password-protected dose log storage |
| Certification Status | Only electronic personal dosimeter to pass all IAEA 2007 performance tests |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | EPD-N2 |
| Instrument Category | Dose Rate Meter / Personal Dosimeter |
| Form Factor | Portable |
| Radiation Types Measured | Gamma and Neutron |
| Detector Technology | Multi-stage Solid-State Detector |
| Energy Range | 25 keV – 10 MeV (photons), Thermal neutrons – 15 MeV (neutrons) |
| Dose Quantity Displayed | Ambient and Personal Dose Equivalent Hp(10) |
| Compliance | IEC 61526 Ed. 4.0 (2018), ANSI N42.20, ISO 15265:2022 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | C401 |
| Price | Upon Request |
| Chlorine Range | 0–1.99 ppm / 2.0–6.0 ppm |
| Chlorine Resolution | 0.01 ppm / 0.1 ppm |
| Chlorine Accuracy | ±0.02 ppm / ±0.2 ppm |
| pH Range | 5.9–8.2 |
| pH Resolution | 0.1 |
| pH Accuracy | ±0.1 |
| Cyanuric Acid Range | 5–90 ppm |
| Cyanuric Acid Resolution | 1 ppm |
| Cyanuric Acid Accuracy | ±4 ppm |
| Light Source | LED (525 nm) |
| Calibration | Single-point user-selectable per test |
| Operating Temperature | 0–50 °C |
| Power Supply | 4 × 1.5 V AAA batteries |
| Battery Life | >3000 measurements |
| IP Rating | IP67 |
| Dimensions (Instrument) | 15.5 × 6.8 × 4.6 cm |
| Weight (Instrument) | 200 g |
| Packaging Dimensions | 35.5 × 16.5 × 10.5 cm |
| Package Weight | 1170 g |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Ion 6+ |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China (Domestically Assembled) |
| Model | EV-1000B |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Continuous Analyzer |
| Configuration | Multi-range Composite VOC Analyzer |
| Measurement Ranges | 0–50 ppm / 0–500 ppm / 0–5000 ppm / 0–5% / 0–100% (auto-ranging) |
| Resolution | As specified in technical manual |
| Accuracy | ±1% F.S. or ±0.1 ppm (whichever is tighter) |
| Response Time | Application-specific (45 s to 60 min per cycle) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FH 40 G NBR |
| Instrument Category | Dose Rate Meter |
| Form Factor | Portable |
| Radiation Type | X-ray and Gamma (γ) |
| Detector Architecture | Dual-detector (NaI(Tl) scintillator + plastic scintillator) with NBR (Natural Background Reduction) patented technology |
| Measurement Range | 1 nSv/h – 100 µSv/h |
| Sensitivity | 2000 s⁻¹/µSv/h |
| Energy Response Range (Probe FHZ 672E-10) | 48 keV – 6 MeV |
| Detection Limit | <20% of typical natural background dose rate |
| Host Unit (FH 40 GL-10) | Energy Range: 30 keV – 4.4 MeV |
| Host Measurement Range | 10 nSv/h – 100 mSv/h |
| Host Sensitivity | 2 s⁻¹/µSv/h |
| Host Weight (excl. batteries) | 410 g |
| Battery Life | >250 h (standalone), >30 h (with FHZ 672E-10 connected) |
| Data Handling | Onboard storage, USB interface, PC configuration & data download capability |
| Signal Processing | ADF (Advanced Digital Filtering) adaptive algorithm |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Dose Rate and Integrated Dose Meter |
| Detector Compatibility | Interchangeable (NaI(Tl), He-3 neutron, GM, scintillation, or proportional detectors) |
| Measurement Range Extension | Up to 4 m via modular fiberglass telescopic pole |
| Weight | 2.6 kg |
| Compliance | Meets IEC 60846-1:2014, IEC 61526:2010, and EURATOM Basic Safety Standards Directive 2013/59 |
| Software Interface | USB and Bluetooth connectivity for real-time data logging and remote monitoring via Thermo Fisher RadEye Suite |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FHT 1377 PackEye |
| Instrument Category | Dose Rate Meter |
| Portability | Portable |
| Measured Radiation Types | Gamma and Neutron |
| Detector Configuration | Dual Plastic Scintillator + Two He-3 Proportional Counters |
| Dose Rate Range | 50 nSv/h – 2 mSv/h |
| Sensitivity | 50 nSv/h |
| Power Consumption | 350 mW |
| Battery Life | ~70 h (7.2 V, 3600 mAh rechargeable Li-ion) |
| Dimensions | 58 cm (H) × 30 cm (W) × 18 cm (D) |
| Weight | 6 kg |
| Data Update Interval | 100 ms |
| LED Indication | 10-level gamma / 10-level neutron |
| Communication | Bluetooth + GPS interface |
| Compliance | IAEA-recommended system for orphan source search |
| Key Technology | Patented Natural Background Rejection (NBR), Digital Filtering, Low-Power Embedded Electronics |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Dose Rate Meter |
| Model | FHT 40NBR |
| Detector Configuration | Dual-detector (NaI(Tl) scintillation crystal + plastic scintillator) |
| Measurement Principle | Gamma photon energy discrimination via pulse-height analysis and NBR (Natural Background Rejection) algorithm |
| Compliance | Designed for field-deployable radiological survey per IEC 60846-1:2014, ANSI N42.33, and EURATOM Directive 2013/59/Euratom |
| Data Interface | USB and Bluetooth® 4.0 |
| Storage Capacity | Up to 10,000 timestamped dose rate records |
| Operating Temperature | –10 °C to +50 °C |
| IP Rating | IP67 |
| Battery Life | >100 hours (alkaline) or >200 hours (rechargeable Li-ion) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Gallery |
| Instrument Category | Benchtop Automated Discrete Analyzer |
| Detection Methods | Photometric (275–880 nm, 12 fixed filters), Enzymatic, Electrochemical (ISE-based pH & Conductivity) |
| Throughput | Up to 200 tests/hour |
| Sample Capacity | 9-position rack × 2 = 18 racks (162 samples) |
| reagent capacity | 6 positions × 9 slots = 54 reagent positions |
| Cuvette Format | Disposable 10-cell flexible strip cuvettes |
| Incubation | Temperature-controlled incubation disc, programmable reaction time |
| Automation Features | Integrated barcode reader, auto-dilution (primary & secondary), on-board washing station, refrigerated sample/reagent carousel |
| Power/Water | <1.5 L/h water consumption |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Gallery Plus |
| Instrument Category | Benchtop Discrete Analyzer |
| Detection Principles | Photometric (Colorimetric), Enzymatic, and Electrochemical (ISE-based) |
| Sample Throughput | Up to 350 tests/hour |
| Wavelength Range | 275–880 nm (12 fixed-position interference filters) |
| Sample Capacity | 54 positions |
| Refrigerated Reagent Capacity | 42 positions |
| Reaction Vessel Format | 10-cell cuvette strips (up to 18 × 2 strips = 360 tests) |
| Incubation | Adjustable temperature incubation block (9 lanes × 10 positions = 90 test slots) |
| Electrochemical Module (ECM) | Integrated ISE-based pH and conductivity measurement |
| Sample Handling | Dual independent probes (sample + reagent), dedicated wash station, barcode reader |
| Dilution Capability | Onboard primary and secondary auto-dilution |
| Power & Utility | <2.5 L/h water consumption |
| Software Compliance | Audit-trail enabled, user-access control, electronic signature support per FDA 21 CFR Part 11 |
| Regulatory Alignment | Designed to support ISO/IEC 17025, ASTM D1293 (pH), ASTM D1125 (conductivity), EPA 365.3 (phosphate), USP <731>, and GLP/GMP workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Harshaw TLD 4500 |
| Instrument Category | Radiation Dosimetry System |
| Instrument Form Factor | Benchtop (Not Portable — Corrected per Technical Specification) |
| Measured Radiation Types | Photons (>1 keV), Neutrons (thermal to 100 MeV), Electrons (>70 keV) |
| Dynamic Range | 7 decades |
| Readout Time | <35 s (2-element card), <60 s (4-element card) |
| Linearity | ±1% deviation |
| Reference Light Stability | <1% variation over 10 consecutive reads |
| Glow Curve Heating Profile | Preheat 0–100 s, Ramp Rate 1–30 °C/s, Max Temp 300 °C (Teflon), 400 °C (Kapton), 600 °C (metal disk) |
| Dose Range (metal-disk heating) | 10 µGy–1 Gy (linear), 1–20 Gy (supralinear) |
| Reusability | 500 cycles (TLD-100 chips), 50 cycles (extremity rings) |
| Operating Temperature | 0–40 °C |
| Dimensions | 370 H × 460 W × 500 D mm |
| Weight | 35 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Laboratory-Based TLD Reader |
| Model | Harshaw TLD 5500 |
| Detector Type | Cooled Photomultiplier Tube (PMT) |
| Sample Capacity | Up to 50 TLD chips per cycle |
| Heating Method | Gas-Heated Linear Ramp (TTP) |
| Max Temperature | 600 °C |
| Linearity | ±1% deviation |
| Dynamic Range | 7 decades |
| Preheat Time | 30 min |
| High Voltage Range | 500–1200 V |
| HV Stability | ±0.005% |
| Dose Units | nC, µGy, mGy, Gy, mrad, mrem, µSv, mSv, Sv |
| Dark Current Equivalent | <50 mGy (Cs-137) |
| MTBF | >10,000 hours |
| Operating Temp | 0–40 °C |
| Storage Temp | −10–60 °C |
| Compliance | Designed for ISO/IEC 17025-accredited dosimetry laboratories |
| Software | Harshaw TLD Analysis Suite with audit trail and 21 CFR Part 11 readiness |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Thermoluminescent Dosimeter (TLD) Reader |
| Model | Harshaw TLD 6600 |
| Detector Type | TLD Reader |
| Radiation Types Measured | Photons (X-rays, γ-rays), Neutrons |
| Measurement Scope | Personal Dose, Environmental Dose |
| Linear Dose Range | Up to 20 Sv |
| Compliance | IEC 61066, ISO 14146, ANSI N13.32 |
| Operating Mode | Benchtop (not portable — corrected per technical specification) |
| Calibration | Automated, Traceable to NIST Standards |
| Quality Control | Built-in QC routines with pass/fail reporting |
| Light Sensitivity | Immune to ambient light interference (non-OSL design) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HFM11 |
| Instrument Category | Dose Rate / Contamination Meter |
| Instrument Type | Portable |
| Measurement Target | Human Hands and Feet |
| Detector Type | High-Performance Scintillation-Based Hand/Foot Probe Array |
| Measurement Mode | Surface Radioactive Contamination Screening |
| Sensitivity | High (optimized for low-level β/γ emitters, e.g., ⁹⁰Sr/⁹⁰Y, ¹³⁷Cs, ⁶⁰Co) |
| Compliance | IEC 61098:2017 (Radiation Protection Instrumentation — Hand and Foot Contamination Monitors) |
| Display | Large-area capacitive touchscreen LCD |
| Power Consumption | Low (<5 W standby, <12 W operational) |
| Data Storage | Internal non-volatile memory (≥10,000 measurement records with timestamp, operator ID, and location tag) |
| Calibration | Automated self-calibration routine with reference source verification |
| Optional Configuration | Integrated whole-body contamination probe module (for supplementary torso/leg screening) |