| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 51i |
| Pricing | Available upon Request |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–1 to 0–10,000 ppmC |
| Zero Noise | 0.025 ppmC RMS (10-sec avg) |
| LOD | 0.050 ppmC (10-sec avg) |
| Zero Drift (24 h) | < 0.50 ppmC |
| Span Drift (24 h) | < 2% of full scale or 0.20 ppmC (whichever is greater) |
| T90 Response Time | 15 s (1-sec avg) |
| Accuracy | ±2.0% of reading or ±0.1 ppmC (whichever is greater) |
| Linearity | ±2% of span (10–150% of span) |
| Sample Flow Rate | 0.75–1.50 L/min |
| Combustion Air Flow | 150–300 mL/min |
| Hydrocarbon-Free Air Flow | 10–35 mL/min (H₂) or 50–120 mL/min (H₂/He mixture) |
| Operating Temperature | 15–35 °C |
| Power Supply | 100/115/220–240 VAC ±10%, 50/60 Hz, 420 W |
| Dimensions (W×H×D) | 425 × 219 × 584 mm |
| Weight | 22.7 kg |
| Output Options | Isolated 0–20 mA / 4–20 mA, RS232/RS485, TCP/IP Ethernet, 10 status relays, power-fail indication |
| Input Options | 16 digital inputs (standard), 8 channels 0–10 VDC analog inputs (optional) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 55i |
| Detection Principle | Back-Flush Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Measurement Range Options | 0–5 / 50 / 500 ppm, 0–10 / 100 / 1000 ppm, 0–20 / 200 / 2000 ppm, or 0–50 / 500 / 5000 ppm (as propane-equivalent NMHC) |
| LOD (300-s avg) | 0.050 ppm for CH₄ and NMHC |
| Zero Noise | 0.025 ppm RMS |
| Response Time (t₉₀) | ~70 s |
| Precision | ±2.0% of reading or ±50 ppb (whichever is greater) |
| Linearity | ±2% of span (10–100% full scale) |
| Sample Flow Rate | ≥0.5 L/min |
| Carrier Gas | N₂, 25–50 mL/min |
| Hydrogen Fuel Gas | 25–50 mL/min (or 100–150 mL/min H₂/He blend) |
| Air for FID | 275–350 mL/min |
| Operating Temperature | 15–35 °C |
| Power | 100–240 VAC ±10%, 50/60 Hz, 420 W |
| Dimensions | 42.5 × 21.9 × 58.4 cm (W×H×D) |
| Weight | 27.2 kg |
| Data Output | Analog (0–20/4–20 mA), RS232/RS485, TCP/IP, 10 relay status channels, power-fail indicator |
| Digital Inputs | 16-bit standard |
| Analog Inputs | 8–10 V (optional) |
| Internal Storage | Flash memory |
| Connectivity | Ethernet port for remote control, data export, and firmware updates |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 55i |
| Price | Upon Request |
| Measurement Principle | Back-Flush Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Detection Target | CH₄ and Total Non-Methane Hydrocarbons (TNMHC) |
| Analysis Cycle | 70 seconds |
| Detection Limit | 0.050 ppm (as propane, 300-s average) |
| Zero Noise | 0.025 ppm RMS |
| Precision | ±2.0% of reading or ±50 ppb (whichever is greater) |
| Linearity | ±2% of span (10–100% full scale) |
| Operating Temperature | 15–35 °C |
| Power Requirement | 100–240 V AC, 50/60 Hz, 420 W |
| Dimensions | 42.5 × 21.9 × 58.4 cm (W×H×D) |
| Weight | 27.2 kg |
| Sample Flow Rate | ≥0.5 L/min |
| Carrier Gas | N₂ (25–50 mL/min) |
| Zero Air | 275–350 mL/min (hydrocarbon-free) |
| Fuel Gas | H₂ (25–50 mL/min) or H₂/He mix (100–150 mL/min) |
| Output Options | 0–20/4–20 mA (isolated), RS232/RS485, TCP/IP, 10 relay status outputs, power failure alarm |
| Input Options | 16-bit digital input (standard), 8–10 V analog input (optional) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 5800 VOCs CEMS |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Continuous Analyzer |
| Typical Configuration | Multi-component VOC Analyzer |
| Target Compounds | Up to 90 Volatile Organic Compounds |
| Resolution | 0.05 ppm |
| Accuracy | ±1% of full scale or ±0.1 ppm (whichever is greater) |
| Response Time | 1 minute (for methane/non-methane hydrocarbons) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Ambient Gas MS |
| Type | Fully Automated Ambient Air Quality Monitoring System |
| Compliance | EPA Reference/Equivalent Methods, CNAS-ISO/IEC 17025 Accredited Deployment, Meets China HJ 653–2013 & HJ 654–2013 Standards |
| Data Capture Rate | >90% (7-day rolling average) |
| Measurement Uncertainty | ≤1% deviation between acquired and true reference values |
| Output Interfaces | 0–10 V analog, RS-232/RS-485 bidirectional digital communication |
| Software Platform | ENVIDATA v5.x (Windows-based, 21 CFR Part 11 compliant audit trail option available) |
| Configuration | Central Station + Remote Substations + QA/QC Laboratory |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Ambient Gas MS |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AQ4001 |
| Instrument Type | Benchtop/Field-Deployable Water Quality Analyzer |
| Key Components | AQ4000 Multi-Parameter Colorimeter, pH Meter, Conductivity Meter, Turbidimeter, Reagent Kits, Portable Carry Case |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Arke SO3 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) for Sulfur Trioxide |
| Accuracy (Indicated Value Error) | ±0 ppm |
| Repeatability | <0.2 ppm (300-s average) |
| Response Time (T90) | <15 s |
| Long-Term Stability (Zero Drift, 24 h) | <0.5 ppm |
| Span Drift | ≤2% of full scale |
| Linearity | ±1% of full scale |
| H₂O Interference | <1×10⁻⁵ (relative to SO₃ signal) |
| SO₂ Interference | <1×10⁻⁴ (relative to SO₃ signal) |
| Measurement Range | 0–200 ppm |
| Zero Noise (300-s avg) | 0.2 ppm |
| Limit of Detection (LOD, 300-s avg) | 0.4 ppm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | ASM-IV |
| Instrument Category | Radiation Dose Rate Meter |
| Form Factor | Portable |
| Measured Substance | Radioactive Materials |
| Detector Type | Large-Volume Scintillation Detector |
| Measurement Scope | Wide Dynamic Range |
| Sensitivity | High |
| Compliance | ANSI N42.35-2006 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | CD650 |
| Instrument Category | Portable/Handheld Water Quality Analyzer |
| Key Parameters | Conductivity / TDS / Salinity / Resistivity / Dissolved Oxygen (DO) / Temperature |
| IP Rating | IP67 |
| Calibration | Auto 4-point (Conductivity), Manual 5-point (Conductivity), Single- or Multi-point DO |
| Electrode Support | Dual- or Quad-ring conductivity cells (cell constant 0.010–10.000 cm⁻¹) |
| DO Measurement Range | 0.00–90.00 mg/L (ppm) and 0.0–600.0% saturation |
| Conductivity Range | 0–500.0 mS/cm across five auto-ranging scales |
| Temperature Range (Instrument) | −10.0–110.0 °C |
| (DO Sensor) | 0–60.0 °C |
| Resolution | 0.01 μS/cm, 0.001 mS/cm, 0.01 mg/L, 0.1 °C |
| Accuracy | ±1% full scale + 1 LSD (Conductivity/TDS/Salinity/Resistivity), ±0.2 mg/L (DO), ±0.5 °C (Temperature) |
| Data Storage | 500 measurement sets |
| GLP Compliance | Yes |
| Communication | IrDA infrared, RS232C, optional PC connectivity via CyberLink software |
| Power | 4×AAA alkaline batteries (>200 h life) or 9 V regulated adapter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Industrial-Grade Digital Water Quality Sensor System |
| Model | DataStick |
| Controller Compatibility | AV38 Universal Digital Controller (optional) |
| Max Sensor Nodes per Network | 247 |
| Communication Protocols | USB, RS-232, RS-485, Modbus RTU, Profibus DP, DeviceNet, Ethernet |
| Calibration | Factory-calibrated |
| Software | AquaComm™ Configuration & Diagnostics Suite |
| Compliance | Designed for industrial process monitoring in accordance with ISO 5667 (water sampling), ASTM D1129 (standard terminology relating to water), and compatible with GLP/GMP data integrity requirements (audit trail, user access control, electronic signature support in AquaComm v3.2+) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | DO6+ |
| Measurement Principle | Galvanic Cell Electrode |
| Dissolved Oxygen Range | 0.00–19.99 mg/L (ppm) |
| Resolution | 0.01 mg/L |
| Accuracy | ±1.5% of full scale |
| Saturation Range | 0.0–199.9% |
| Resolution | 0.1% |
| Temperature Range | 0.0–50.0 °C (32–122 °F) |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.5 °C |
| Salinity Compensation | 0.0–50.0 ppt (manual input, automatic correction) |
| Pressure Compensation | 500–1499 mmHg or 66.6–199.9 kPa (manual input, automatic compensation) |
| Calibration | Two-point (0% and 100% O₂) |
| Temperature Compensation | ATC/MTC (0.0–50.0 °C) |
| Electrode Type | Galvanic (self-polarizing) sensor |
| Response Time (t₉₅) | ≤60 s |
| Data Hold & Auto-Off | Yes (20 min inactivity) |
| Display | Single-line LCD |
| Input Interfaces | BNC + 2.5 mm audio jack |
| Power | 4 × AAA alkaline batteries |
| Battery Life | >700 hours |
| Dimensions (instrument) | 14 × 17 × 3.5 cm |
| Weight (instrument) | 200 g |
| Packaging Dimensions | 24 × 17 × 8 cm |
| Weight (shipping) | 0.55 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | CD650 |
| Instrument Category | Portable / Handheld Water Quality Analyzer |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | DO110 |
| Instrument Type | Portable |
| Electrode Type | Galvanic Cell |
| DO Range | 0.00–19.99 mg/L (ppm) |
| DO Resolution | 0.01 mg/L |
| DO Accuracy | ±1.5% of full scale |
| Saturation Range | 0.0–199.9% |
| Saturation Resolution | 0.1% |
| Salinity Compensation | 0.0–50.0 ppt (manual entry, auto-applied) |
| Atmospheric Pressure Compensation | 500–1499 mmHg / 66.6–199.9 kPa (manual entry, auto-applied) |
| Temperature Range | 0.0–50.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Calibration | Dual-point (% saturation) or single-point (mg/L) |
| Data Storage | 100 measurement sets |
| Display | Dual-line LCD (5.8 × 3.3 cm) |
| IP Rating | IP54 |
| Power | 4 × AA alkaline batteries (typical life >700 h) or 9 V regulated DC adapter (200 mA) |
| Dimensions (instrument) | 18 × 9 × 4 cm |
| Weight (instrument) | 220 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher brand) |
| Type | Galvanic Cell Dissolved Oxygen Meter |
| Model | DO600 |
| Measurement Range | 0.00–90.00 mg/L (ppm) and 0–600.0% saturation |
| Resolution | 0.01 mg/L, 0.1% sat, 0.1 °C, 0.1 ppt, 0.1 mmHg / 0.1 kPa |
| Accuracy | ±0.2 mg/L (DO), ±2.0% (saturation), ±0.3 °C (temperature), ±0.1 ppt (salinity) |
| Compensation | Automatic temperature, salinity (manual input), and barometric pressure (built-in barometer) |
| Calibration | Two-point (0% and 100%) or single-point (mg/L) |
| Data Storage | 500 readings with timestamp, temperature, salinity, and pressure metadata |
| Communication | IrDA infrared and RS232C |
| Enclosure Rating | IP67 |
| Power | 4×AA alkaline batteries (>200 h life) or 9 V regulated DC adapter |
| Dimensions (instrument) | 18.3 × 9.5 × 5.7 cm |
| Weight (instrument) | 460 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DO6000 |
| Price | Available Upon Request |
| DO Range | 0.00–60.00 mg/L (ppm) / 0–1272 mbar |
| DO Resolution | 0.01 mg/L (0.1 mbar) |
| DO Accuracy | ±1% of reading + 1 LSD |
| % Saturation Range | 0.0–600.0% |
| % Saturation Resolution | 0.1% |
| % Saturation Accuracy | ±1% of reading + 1 LSD |
| Salinity Compensation Range | 0.0–45.0 ppt |
| Salinity Resolution | 0.1 ppt |
| Atmospheric Pressure Compensation Range | 450–825 mmHg |
| Pressure Resolution | 1 mmHg |
| Temperature Range | −5.0 to 46.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Data Storage Capacity | 1,000 measurement records |
| Display | 11.43 × 15.24 cm Windows CE–based color touchscreen |
| Operating Temperature | 5.0–45.0 °C |
| Power Supply | 9 V DC regulated adapter (100–240 VAC input, SMPS) |
| Dimensions (Instrument) | 16.5 × 23.5 × 8.9 cm |
| Weight (Instrument) | 1100 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Benchtop Analyzer |
| Model | PCD6500 |
| Measurement Parameters | pH / pH-FET / ORP / Ion Concentration / Conductivity / TDS / Salinity / Resistivity / Dissolved Oxygen (DO) / BOD / OUR / BOUR / Temperature (°C) |
| pH Range | −2.000–20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.1 / ±0.01 / ±0.002 + 1 LSD |
| Ion Range | 1×10⁻⁷–9.99×10¹⁰ ppm |
| Ion Resolution | 4-digit |
| Ion Accuracy | ±0.17 n% |
| Temperature Range | −5.0–105.0 °C (DO: −5.0–46.0 °C) |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.2 °C |
| ORP Range | ±2000.0 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.2 mV |
| Conductivity Ranges | 0–200 μS/cm, 200.0 μS/cm–2.000 mS/cm, 2.000–20.00 mS/cm, 20.00–500.0 mS/cm |
| Cond Resolution | 0.001/0.01/0.1 μS/cm or mS/cm |
| Cond Accuracy | ±0.5% FS + 1 LSD |
| TDS Ranges | 0–200.0 ppm, 200.0–2000 ppm, 2.000–20.00 ppt, 20.00–500.0 ppt |
| TDS Resolution | 0.001/0.01/0.1 ppm or ppt |
| TDS Accuracy | ±0.5% FS + 1 LSD (±1% FS + 1 LSD for select ranges) |
| Salinity Ranges | 0–0.094 ppt, 0.094–1.000 ppt, 1.0–11.50 ppt, 11.50–90.00 ppt |
| Salinity Resolution | 0.1 / 0.01 / 0.001 ppt |
| Salinity Accuracy | ±0.5% FS + 1 LSD |
| Resistivity Range | 0–100.0 MΩ |
| Resistivity Resolution | 0.1/0.01/0.001 kΩ or 0.1/0.01 mΩ |
| Resistivity Accuracy | ±0.5% FS + 1 LSD |
| DO Range | 0–60 mg/L |
| DO Resolution | 0.01 mg/L |
| DO Accuracy | ±0.1 mg/L + 1 digit |
| Calibration Points | up to 5-point for pH and ion |
| Temperature Compensation | Auto/manual for pH (−5–105 °C), conductivity (−5–100 °C), DO (−5–46 °C) |
| GLP Compliance | Yes |
| Data Storage | 1000 entries per user |
| Operating Temperature | 5–45 °C |
| Display | Windows CE–based color touchscreen (11.43 × 15.24 cm) |
| Interfaces | DC phono sockets, DIN, SD card reader, USB, RJ45, BNC, phono |
| Output Options | USB, IrDA, RS232C |
| Power Supply | 9 V regulated, 3.3 A (100–240 VAC, SMPS) |
| Dimensions (H×W×D) | 16.5 × 23.5 × 8.9 cm |
| Weight | 1100 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable/HANDHELD Water Quality Analyzer |
| Model | PD650 |
| Measurement Parameters | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen (DO), Temperature |
| IP Rating | IP67 |
| Accuracy (pH) | ±0.002 pH |
| Conductivity Accuracy | ±1% of full scale + 1 LSD |
| DO Range | 0.00–90.00 mg/L |
| Data Storage | 500 GLP-compliant entries |
| Auto-Range Conductivity | 5 ranges up to 500 mS/cm |
| Electrode Recognition | Automatic 2-/4-cell conductivity cell detection |
| Built-in Barometer | Yes |
| Wireless Capability | IrDA & RS232C |
| Battery Life | >200 hours |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | DO6+ |
| Price | Upon Request |
| IP Rating | IP54 |
| Electrode Type | Galvanic Cell |
| DO Range | 0.00–19.99 mg/L (ppm) |
| DO Resolution | 0.01 mg/L |
| DO Accuracy | ±1.5% of full scale |
| % Saturation Range | 0.0–199.9% |
| % Saturation Resolution | 0.1% |
| Salinity Compensation | 0.0–50.0 ppt (manual entry, automatic compensation) |
| Atmospheric Pressure Compensation | 500–1499 mmHg / 66.6–199.9 kPa (manual entry, automatic compensation) |
| Temperature Range | 0.0–50.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Compensation | Automatic or Manual (0.0–50.0 °C) |
| Display | LCD (4.5 × 2.3 cm) |
| Auto-Off | 20 min inactivity |
| Power | 4 × 1.5 V AAA alkaline batteries |
| Battery Life | >700 hours |
| Dimensions (instrument) | 15.7 × 8.5 × 4.2 cm |
| Weight (instrument) | 255 g |
| Packaging Dimensions | 36 × 28 × 8 cm |
| Package Weight | 1555 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Eutech DO700 |
| Price | Available Upon Request |
| DO Range | 0–30.0 mg/L |
| DO Resolution | 0.01 mg/L |
| DO Accuracy | ±0.5% of full scale |
| % Saturation Range | 0–199.9% / up to 300% |
| % Saturation Resolution | 0.1% |
| % Saturation Accuracy | ±0.5% of full scale |
| Salinity Compensation Range | 0–50 ppt |
| Salinity Resolution | 0.1 ppt |
| Barometric Pressure Adjustment Range | 450–825 mmHg |
| Barometric Resolution | 1 mmHg |
| Temperature Range | 0.0–50.0 °C (32.0–122.0 °F) |
| Temperature Resolution | 0.1 °C/°F |
| Temperature Accuracy | ±0.5 °C / ±0.9 °F |
| Data Storage Capacity | 100 measurement records |
| Auto-Stability Indicator | Yes |
| Display | Large backlit LCD |
| Includes | Electrode stand |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Type | Laboratory Water Quality Analyzer |
| Model | Eutech PC2700 |
| Instrument Category | Benchtop Multiparameter Water Quality Meter |
| Compliance | GLP-compliant data logging |
| Connectivity | RS232 bidirectional interface |
| Electrode Interface | BNC, 8-pin DIN (2- or 4-ring), DC socket |
| Display | Backlit LCD (5.9 × 7.8 cm) |
| Dimensions (H×W×D) | 17.5 × 15.5 × 6.9 cm |
| Weight | 0.65 kg (unit) |
| Operating Temperature | 0–50 °C |
| Power Supply | 9 V DC regulated adapter (100–240 VAC SMPS) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PCSTestr 35 |
| Instrument Category | Portable / Handheld Water Quality Analyzer |
| Key | pH Range 0.00–14.00, Resolution 0.01 pH, Accuracy ±0.01 pH |
| Calibration | Up to 5-point auto pH, 3-point auto/manual conductivity, 3-point manual TDS, 1-point auto salinity >1.00 ppt |
| Auto-Range Selection | Yes |
| Electrode Module | Integrated replaceable 5-in-1 sensor |
| Power | 4 × 1.5 V button cells (>150 h life) |
| Dimensions | 16.5 × 3.8 cm (unit), Weight: 90 g |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Auto-Off | 8.5 min (configurable) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | EV-1000 VOCs CEMS |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Analytical System |
| Typical Configuration | Multi-component VOC Analyzer |
| Detection Range | Volatile Organic Compounds (VOCs), configurable up to 50 ppm, 500 ppm, 5000 ppm, 5% or 50% as methane |
| Resolution | 0.05 ppm |
| Accuracy | ±1 % of full scale or ±0.1 ppm (whichever is tighter) |
| Response Time | ≤60 seconds (average analysis cycle time) |
| Repeatability | ±1 % f.s. or ±0.1 ppm |
| Zero Drift | ±1 % f.s. or ±0.1 ppm |
| Span Drift | ±2 % f.s. or ±0.1 ppm |
| Sample Flow Rate | 600 mL/min (analysis stream) |
| Sample Replacement Rate | 3–10 L/min (max) |
| Calibration Interval | User-configurable (monthly to annual) |
| Operating Temperature | 0–45 °C |
| Ambient Storage Temperature | –20–60 °C |
| Relative Humidity | 0–85 % RH (non-condensing) |
| Power Supply | AC 220 V, 50 Hz, 1.5 kW |
| Dimensions | 650 mm (W) × 580 mm (D) × 1250 mm (H) |
| Weight | 160 kg |
| Carrier Gas | Oil/water-free air or N₂, 60 mL/min at 2 kg/cm², THC < 0.1 ppm |
| FID Fuel Gas | H₂, 30 mL/min at 2 kg/cm², purity >99.999%, THC < 0.1 ppm |
| FID Make-up Gas | Oil/water-free air, 300 mL/min at 2 kg/cm², THC < 0.1 ppm |
| Zero Gas | Oil/water-free air or N₂, 2 kg/cm², THC < 0.1 ppm |
| Span Gas | Hydrocarbon standard in balance gas (air or N₂), 1 kg/cm² inlet pressure |
| Purge Gas | Oil/water-free air, 10 L/min at 2 kg/cm², THC < 1 ppm |
| Standard Output | Modbus TCP |
| Optional Outputs | 4–20 mA, RS232, RS485 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Israel |
| Manufacturer | OPGAL (Thermo Fisher subsidiary) |
| Type | Portable OGI Camera |
| Detection Principle | Infrared Absorption Imaging (Mid-Wave IR, MWIR) |
| Detection Range | >400 VOCs including methane, ethylene, propane, butane, pentane, hexane, heptane, octane, benzene, toluene, xylene, styrene, ethylbenzene, formaldehyde, acetaldehyde, propionaldehyde, butadiene, butene, isobutylene, isoprene, methanol, ethanol, isopropanol, methyl ethyl ketone, acetone, ethyl acetate, methyl acetate, ethylene oxide, propylene oxide, acetic acid, and other hydrocarbons & oxygenates |
| Display Resolution | 640 × 480 |
| Thermal Sensitivity (NETD) | <12 mK @ 25 °C (for methane) |
| Temperature Measurement Accuracy | ±1 °C (0–100 °C) |
| Response Time | Real-time / ≤0.1 s |
| Certifications | ATEX Zone 2 |
| Data Storage | Integrated 64 GB SSD |
| Connectivity | Built-in Wi-Fi for live streaming and remote file transfer |
| LDAR Integration | Onboard LDAR workflow engine with component tagging, geotagging, and Method 21 data fusion (PID/FID) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Model | F090 |
| Ion Type | Fluoride |
| Measurement Range (F⁻) | 0.02–2000 ppm |
| Resolution | 0.01 ppm (<1 ppm), 0.1 ppm (1.0–199.0 ppm), 1 ppm (>200 ppm) |
| Accuracy | ±0.5% of full scale (monovalent ions) |
| pH Range | 0.00–14.00, ±0.002 pH accuracy |
| ORP Range | ±1999 mV |
| Temperature Range | 0–100 °C, ±0.5 °C accuracy |
| Calibration Points | 2–5 points |
| Data Storage | 100 sets |
| Display | Dual-line LCD (5.6 × 7.5 cm) |
| Power | 9 V DC adapter (100–220 V AC input) |
| Dimensions (instrument) | 17.5 × 15.5 × 6.9 cm |
| Weight (instrument) | 650 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | FH40G |
| Instrument Class | Dose Rate / Ambient Dose Equivalent Rate Meter |
| Form Factor | Portable |
| Measurable Radiation Types | X-ray, Gamma (γ), Neutron (n), Alpha (α), Beta (β) |
| Detector Types Supported | Scintillation, GM Tube, Ionization Chamber, Proportional Counter, He-3 Neutron Detector |
| Measurement Quantities | Ambient Dose Equivalent Rate H*(10), Personal Dose Equivalent Hₚ(10), Contamination (Bq/cm²), Count Rate (cps) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | FHT 6020 |
| Instrument Category | Radiation Dose Rate Meter |
| Instrument Form Factor | Portable |
| Measured Radiation Types | Gamma, Neutron, X-ray |
| Detector Types | BF₃ proportional counter with polyethylene moderator |
| Measurement Range | 0.1 nSv/h – 0.4 Sv/h |
| Sensitivity (Cf-252) | 0.49 cps/(µSv/h) |
| Interface Options | RS232, RS485, Analog I/O, Digital I/O |
| Maximum Detector Channels | 16 |
| Data Storage | Internal non-volatile memory with timestamped logging |
| Software Compatibility | FHT 6020.EXE configuration tool, Thermo ViewPoint™ radiation monitoring platform |
| Alarm Outputs | Relay contacts for safety interlocks, local/remote audible/visual alarms, operator error detection |
| Compliance | Designed to support IEC 60846-1:2014, IEC 61526:2010, and ANSI N42.17A for dose rate instrumentation |
| Operating Temperature | −10 °C to +50 °C |
| IP Rating | IP54 (dust-protected, water-splashing resistant) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Hg-CEMS |
| Instrument Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) with Catalytic Dry Conversion |
| Detection Target | Elemental Mercury (Hg⁰), Oxidized Mercury (Hg²⁺), Total Mercury |
| Detection Limit | 2 ng/m³ (300-s average) |
| Zero Noise | 1 ng/m³ (300-s average) |
| Zero Drift (24 h) | <5 ng/m³ |
| Response Time (T₉₀) | 110 s (60-s averaging) |
| Linearity | ±1% of full scale |
| Hg⁰ Range | 0–50 µg/m³ (pre-dilution) |
| Dilution Ratio | 25:1 to 100:1 |
| SO₂ Interference Rejection Ratio | 8.4×10⁸:1 |
| NOₓ Interference Rejection Ratio | 4.2×10⁹:1 |
| Operating Temperature | 5–40 °C |
| Power Supply | 100/115 VAC ±10%, 275 W |
| Dimensions (W×H×D) | 425 × 219 × 584 mm |
| Weight | 22.2 kg |
| I/O | 16 digital inputs, 10 digital outputs, 6 isolated 0–20/4–20 mA analog outputs, 8 analog inputs (0–10 V), dual RS232/RS485, built-in Ethernet (TCP/IP), Modbus support |
| Compliance | EPA Performance Specification 12A (PS-12A), 40 CFR Part 60 Appendix B, 40 CFR Part 75, ASTM D6784, ISO 15202, GLP/GMP-ready data integrity architecture |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MFC-TSP |
| Typical Configuration | Total Suspended Particulates (TSP) Sampling System |
| Flow Rate Range | 1.13 m³/min (40 ACFM) |
| Flow Accuracy | < ±1% deviation over 24 h |
| Pressure Drop Compensation | Aerodynamically optimized critical-flow Venturi restrictor |
| Flow Stability | Independent of filter loading, ambient temperature, and barometric pressure |
| Power Supply | 110 VAC, single-phase, 60 Hz (optional configurations available) |
| Motor | 1.0 HP, 7 A, 840 W |
| Weight | 62 kg (total system) |
| Cabinet | 22 kg |
| Cyclone/Cut-point Assembly | 25 kg |
| Blower & Filter Holder | 12 kg |
| Dimensions (Cabinet) | 129 cm H × 56 cm W × 56 cm D |
| Dimensions (Cyclone) | 81 cm H × 81 cm W × 63.5 cm D |
| Dimensions (Blower + Filter Holder) | 71 cm H × 53 cm W × 48 cm D |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MIRAN SapphIRe |
| Instrument Type | Portable |
| Detection Target | Multi-component Gases |
| Wavelength Range | 7.7–14.1 µm (tunable filter) + seven fixed-bandpass filters at 1.8, 3.3, 3.6, 4.0, 4.2, 4.5, and 4.7 µm |
| Sample Cell Path Length | 0.5 m |
| Sample Cell Volume | 2.23 L |
| Flow Rate | 15 L/min |
| Analysis Time | 20 s (startup) to 3 min (full spectral acquisition) |
| Response Time | ≤18 s to 90% of final reading |
| Display | 8-line × 40-character LCD |
| Power | Internal rechargeable NiCd battery (7.2 V, 5.7 Ah) |
| Dimensions | 553 mm (W) × 365 mm (H) × 193 mm (D) |
| Weight | ~10 kg |
| Preloaded Calibration Curves | Up to 120 gases (configurable per model variant) |