Environmental Test Chamber
Filter
Showing 3091–3120 of 3643 results
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (Reference Only) |
| Humidity Range | 30–80% RH (Light Cycle), up to 90% RH (Dark Cycle) |
| Temperature Range | Ambient to 80°C |
| Temperature Uniformity | ±2.5°C |
| Temperature Fluctuation | ±1°C |
| Black Panel Temperature | 53°C (±3°C) |
| Humidification Method | Steam Generation via SUS304 Stainless Steel Heater |
| Humidity Sensor | Dry-Wet Bulb Type |
| Temperature Sensor | PT100 Platinum Resistance Thermometer |
| Heating System | Nickel-Chromium Alloy Heaters |
| Construction | SUS304 Stainless Steel Humidification Reservoir with Auto Water-Level Control |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,000 (approx.) |
| Sample Rack Dimensions | 500 × 400 mm |
| Irradiation Source | Air-Cooled Metal Halide Lamps |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Irradiance Uniformity | ≥90% |
| Black Panel Temperature (BPT) Range | 40–85 °C |
| Cooling Method | Internal Forced-Air Circulation |
| Filter System | Custom High-Borosilicate Glass + 30% IR-Blocking Filter (optional) |
| Irradiance Monitoring | Integrated UV Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| Display & Control | LCD-based Irradiance Accumulation Meter with Auto-Calculation |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ±10 °C) |
| Humidity Range | 40–70 % RH (Illuminated), 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Time | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted lamp with reflective direct irradiation |
| Spectral Range | 295–450 nm |
| Irradiance Level | 200 ±8 W/m² |
| UV Sensor | Calibrated UV Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| Filter Requirement | Optional 30 % IR-reducing filter |
| Irradiance Monitoring | LCD-based integrated radiometric energy integrator |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Irradiance Uniformity | ≥90 % across Sample Plane |
| Sample Tray Dimensions | 500 × 400 mm |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| UV Radiometer | Calibrated UV Spectral Irradiance Transmitter (Developed by No. 622 Research Institute) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| UV Irradiance | 200 ± 8 W/m² |
| UV Spectral Irradiance Transmitter | Integrated, developed by Beijing Institute of Space Mechanics and Electricity (622 Institute) |
| IR-Reduction Filter | Custom 30% infrared energy attenuation filter (optional, specify at order) |
| Irradiance Monitoring | LCD-based cumulative irradiance meter with real-time auto-calculation |
| Cooling System | Internal forced-air circulation cooling |
| UV Transmitting Filter | Single custom high-borosilicate glass filter |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illumination), 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Irradiance | 200 ± 8 W/m² |
| Spectral Range | 295–450 nm |
| Irradiance Uniformity | ≥90 % |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50 ± 10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Time | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray | 500 × 400 mm |
| Irradiation Geometry | Top-mounted, Direct Reflective Illumination |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance | 200 ± 8 W/m² (broadband, 295–450 nm) |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| IR Filter | Optional 30% infrared energy rejection filter |
| Irradiance Monitoring | LCD-based Cumulative Irradiance Integrator |
| Cooling Method | Internal Forced-Air Circulation System |
| Irradiance Uniformity | ≥90% across sample plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Heating Time | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Configuration | Top-mounted, Reflective Direct Illumination |
| Irradiance Uniformity | ≥90% |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance Level | 200 ± 8 W/m² |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (developed by China Academy of Engineering Physics – Institute 622) |
| IR Filter | Optional 30% Infrared Energy Blocking Filter |
| Irradiance Monitoring | LCD-Based Cumulative Irradiance Integrator with Real-Time Calculation |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,000 (FOB) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (Single) |
| Sample Rack Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-Mounted Reflector-Based Direct Illumination |
| Spectral Range | 295–450 nm |
| Irradiance Level | 200 ± 8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90% across rack surface |
| UV Monitoring | Integrated UV Spectral Irradiance Transmitter (developed by China Academy of Engineering Physics – Institute 622) |
| Filter System | Custom High-Borosilicate Glass + IR-Blocking Filter (removes ~30% infrared energy) |
| Control Interface | LCD-based Irradiance Accumulation Meter with Real-Time Dose Integration |
| Cooling Method | Internal Forced-Air Circulation System |
| Compliance | Designed per ISO 4892-2, ASTM G155, SAE J2527, and GB/T 16422.2 requirements |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Sample Rack Dimensions | 500 × 400 mm |
| Irradiation Source | Air-Cooled Metal Halide Lamp(s) |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Irradiance Uniformity | ≥90% |
| Black Panel Temperature Range | 40–85 °C |
| Cooling Method | Internal Forced-Air Circulation |
| Filter | Custom High-Borosilicate Glass (IR-Reduction ~30%) |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (calibrated per ISO 4892-2) |
| Control Display | LCD-Based Irradiance Integration & Cumulative Dose Monitoring |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Sample Capacity | 500 × 400 mm Test Tray |
| Irradiation Source | Air-Cooled Metal Halide Lamp(s) |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Uniformity | ≥90% across Exposure Plane |
| Cooling Method | Internal Forced-Air Circulation |
| Filter | Custom High-Borosilicate Glass + Optional IR-Reduction Filter (30% IR attenuation) |
| UV Monitoring | Integrated Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| Control Interface | LCD-Based Irradiance Accumulation Meter with Real-Time Dose Integration |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Temperature Range | RT to 85 °C (Operating Range: 50 ±10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Irradiation Geometry | Top-Mounted Reflector-Based Direct Illumination |
| Spectral Output | 295–450 nm (UV-A/UV-B/Visible) |
| Irradiance Uniformity | ≥90 % across Sample Plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Temperature Range | RT to 85°C (operational test temp: 50 ± 10°C) |
| Humidity Range | 40–70% RH (lighting), 50–90% RH (dark cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW air-cooled metal halide lamp (1 unit) |
| Sample Rack | 500 × 400 mm stainless steel rack |
| Irradiation Geometry | Top-mounted, direct-reflection configuration |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90% across exposure area |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50°C ±10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Irradiance | 200 ±8 W/m² (295–450 nm) |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance Uniformity | ≥90% |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (Calibrated per ISO 17025 Traceable Standards) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted lamp with reflective direct irradiation |
| Spectral Range | 295–450 nm (UV-A/UV-B broadband) |
| Irradiance Level | 200 ± 8 W/m² |
| UV Radiometer | Integrated Spectral UV Irradiance Transmitter (developed by China Academy of Engineering Physics, Institute 622) |
| IR Filtering | Optional 30 % infrared energy rejection filter (custom order required) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50°C ±10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted, Reflector-Assisted Direct Illumination |
| Spectral Range | 295–450 nm |
| Irradiance Uniformity | ≥90% across Exposure Plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Key Features | Temperature Range: RT to 85°C (Operating Range: 50 ±10°C) |
|---|---|
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | RT → 85°C in ≤25 min |
| Light Source | Single 2.5 kW Air-Cooled Metal Halide Lamp |
| Spectral Output | 295–450 nm (UV–Visible) |
| Irradiance at Sample Plane | 200 ±8 W/m² |
| Irradiance Uniformity | ≥90% |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| Compliance | Designed per ISO 4892-2, ASTM G154, IEC 60068-2-5, and GB/T 16422.2 |
| Brand | Suying |
|---|---|
| Origin | Shanghai, China |
| Model | BRS-040 / BRS-080 / BRS-120 / BRS-160 / BRS-250 / BRS-340 |
| Temperature Range | −70 °C to +150 °C (configurable) |
| Humidity Range | 30–98% RH |
| Temperature Uniformity | ±2.0 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Deviation | ±3.0% RH (>75% RH) |
| Control System | Touchscreen PID Controller with Programmable Logic |
| Compliance | GB/T 2423.1–4, GB 11158, GB 10589, GJB 150.3/4/9 |
| Cooling Method | Air-Cooled or Water-Cooled Mechanical Compression Cascade Refrigeration |
| Heating | Nickel-Chromium Alloy Heaters |
| Humidification | Tank-Type Steam Generator |
| Safety Protections | Overtemperature, Dry-Burn, Low-Water, Phase Failure, Compressor Overpressure & Overload, Fan Overload, Leakage & Short-Circuit Protection |
| Communication Interface | RS-485, Ethernet (optional) |
| Brand | Suying |
|---|---|
| Origin | Shanghai, China |
| Model | CH-500 / CH-1000 |
| Max Temperature | 200–300 °C |
| Temperature Range | RT+10 °C to 250 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Air Exchange Rate | 3–20 air changes/hour (adjustable) |
| Internal Chamber Dimensions (W×H×D) | 800×900×700 mm |
| Brand | Suying |
|---|---|
| Model | CRS-1000 |
| Salt Spray Deposition Rate | 0.5–3.0 mL/h/80 cm² |
| Temperature Range | Ambient to +55°C |
| Chamber Interior Dimensions (W×D×H) | 1200 × 920 × 900 mm |
| Humidity Control Range (Condensation Mode) | 95–100% RH |
| Dry Mode Temperature Range | Ambient to +70°C |
| Dry Mode Humidity Range | 10–50% RH |
| Compressed Air Supply | Oil-free, 4.0–6.0 bar |
| Power Supply | AC 380 V, 3-phase |
| Deionized Water Supply Pressure | 0.5–5.0 bar |
| Solution Tank Capacity | 50 L with Agitator |
| Operating Ambient | 18–30°C, ≤85% RH |
| Brand | Suying |
|---|---|
| Model | FC-40 |
| Origin | Shanghai, China |
| Temperature Range (Hot Chamber) | Ambient to 150 °C |
| Temperature Accuracy (Hot Chamber) | ±0.1 °C at 150 °C |
| Temperature Range (Cold Chamber) | 0–100 °C |
| Temperature Accuracy (Cold Chamber) | ±0.1 °C |
| Hot Chamber Dimensions (L×W×H) | 630 × 430 × 550 mm |
| Cold Chamber Dimensions (L×W×H) | 430 × 230 × 620 mm |
| Hot Chamber Net Weight | 35 kg (excl. heat transfer medium) |
| Cold Chamber Net Weight | 18 kg (excl. heat transfer medium) |
| Power Supply | AC 220 V, 50 Hz |
| Compliant Standards | ISO 6452, DIN 75201, SAE J1756, QB/T 2728, BS EN 14288, PV 3920, PV 3015, ES-X83231, NES M0161, D45 1727, GM 9305P, TSM 0503G |
| Brand | Suying |
|---|---|
| Origin | Shanghai, China |
| Model | GDJS-100 / GDJS-225 / GDJS-500 / GDJS-800 / GDJS-1000 |
| Temperature Range | -20°C to 150°C (optional: -40°C, -60°C, -70°C) |
| Humidity Range | 30–98% RH |
| Temp. Uniformity | ±2°C |
| Temp. Stability | ±0.5°C |
| Humidity Deviation | +2 / -3% RH |
| Heating Rate | 1.0–3.0°C/min |
| Cooling Rate | 0.7–1.0°C/min |
| Control System | Imported Programmable Touchscreen Controller (5.7" LED, 100 programs × 1000 segments) |
| Compliance | GB/T 2423.1–2008, GB/T 2423.2–2008, GB/T 2423.3–2006, GB/T 2423.4–2008 |
| Brand | Suying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Range | GDJS-100 / GDJS-225 / GDJS-500 / GDJS-800 / GDJS-010 |
| Temperature Range | −70 °C to +150 °C (configurable) |
| Humidity Range | 30–98 % RH |
| Temp. Uniformity | ±2 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Deviation | +2 / −3 % RH |
| Heating Rate | 1.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control Resolution | 0.1 °C / 1 % RH |
| Power Supply | AC 380 V ±10 %, 50 Hz, 3-phase 5-wire |
| Compliance | GB/T 2423.1–2008, GB/T 2423.2–2008, GB/T 2423.3–2006, GB/T 2423.4–2008 |
| Brand | Suying |
|---|---|
| Origin | Shanghai, China |
| Model | GDS/GSJ-100 / GDS/GSJ-250 / GDS/GSJ-500 / GDS/GSJ-800 / GDS/GSJ-1000 |
| Temperature Range | -40 °C to +150 °C |
| Humidity Range | 30–98 %RH |
| Temp. Uniformity | ≤ ±2 °C |
| Temp. Stability | ≤ ±0.5 °C |
| Heating Rate | -20 °C → 100 °C in ~35 min |
| Cooling Rate | 25 °C → -40 °C in ~50 min |
| Compliance | IEC 61215, IEC 61646, IEC 61701, IEC 61730-2, IEC 61370, GB/T 2423.1–2001, GB/T 2423.2–2001 |
| Brand | SuYing |
|---|---|
| Origin | Shanghai, China |
| Model | GDW-100 / GDW-250 / GDW-500 / GDW-800 / GDW-1000 |
| Temperature Range | A: −20°C to +150°C |
| B | −40°C to +150°C |
| C | −60°C to +150°C |
| D | −70°C to +150°C |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Heating Rate | −20°C → +100°C in ~35 min (typical) |
| Cooling Rate | +25°C → −40°C in ~50 min (typical) |
| Internal Dimensions (D×W×H, mm) | 450×450×500 to 1000×1000×1000 |
| External Dimensions (D×W×H, mm) | 1150×450×500 to 1650×1480×2200 |
| Power Supply | AC 380 V ±10%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Safety Protections | Over-temperature, over-current, compressor high-pressure, motor overload, leakage current, short-circuit |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB 10589–1989, GB 10592–1989, GB 11158–1989, GB/T 5170.2–1996 |