Gas Chromatograph
Filter
Showing 481–510 of 614 results
| Brand | SciTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Laboratory Gas Chromatograph |
| Model | GC9800-N/FH |
| Instrument Type | Laboratory Gas Chromatograph |
| Primary Application | Dedicated High-Purity Gas Analysis |
| Oven Temperature Range | 8 °C above ambient to 400 °C |
| Oven Ramp Rate | 0.1–39 °C/min (adjustable in 0.1 °C increments) |
| Oven Cooling Rate | 400 °C → 50 °C in ≤4 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–250 kPa |
| Injector Maximum Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–250 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| FID Detection Limit | ≤8.0×10⁻¹² g/s (n-hexadecane) |
| FID Baseline Noise | ≤1×10⁻¹³ A |
| FID Baseline Drift | ≤7×10⁻¹³ A / 30 min |
| FID Linear Dynamic Range | 10⁷ |
| Temperature Control Accuracy | ±0.5% of setpoint |
| Max. Temperature Program Steps | 8 |
| Temperature Program Reproducibility | ≤1% RSD |
| [Brand | SDL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Portable Gas Chromatograph |
| Application Scope | Environmental Air & Stack Emission Monitoring |
| Compliance | HJ 1012–2018 |
| Detection Targets | Methane, Total Hydrocarbons (THC), Non-Methane Hydrocarbons (NMHC), BTEX (Benzene, Toluene, Xylenes) |
| Power Options | Integrated Rechargeable Battery (≥4 hr operation) & 220 VAC Input |
| Weight | ≤10 kg |
| Column Technology | Capillary GC Separation with Valve-Switching Configuration |
| Detector | Flame Ionization Detector (FID) with Auto-Ignition & Flame Temperature Monitoring |
| Sample Path Heating | Full-path heated to ≥120 °C |
| Gas Control | Fully Automated Pressure Regulation (Accuracy: ±0.18% F.S.) |
| Hydrogen Supply | Low-Pressure Metal Hydride Cartridge |
| Carrier/Calibration Gas Supply | High-Pressure Cylinders (Manual Hot-Swap Enabled)] |
| Brand | SERVOPRO (Servomex) |
|---|---|
| Origin | United Kingdom |
| Model | NanoChrome ULTRA |
| Instrument Type | Online Gas Chromatograph |
| Application Domain | Ultra-High-Purity (UHP) Gas Analysis |
| Temperature Control Range | +5°C to +40°C |
| Carrier Gas Flow Rate | 90–810 mL/min |
| Carrier Gas Pressure | 85 psig (for O₂ background), 80 psig (for other backgrounds) |
| Sample Inlet Pressure Setting | 30 psig (application-dependent) |
| Sample Inlet Total Flow Setting | 0–300 mL/min (application-dependent) |
| Brand | JINPU |
|---|---|
| Origin | Shandong, China |
| Model | OG-2000V |
| Instrument Type | Online Gas Chromatograph for Geochemical Rock-Eval Analysis |
| Detector | Dual Flame Ionization Detector (FID) |
| Minimum Hydrocarbon Detection | 0.001 mg HC/g rock |
| Baseline Drift | < 0.1 mV/30 min |
| Linear Range | 10⁶ |
| FID Temperature Control Accuracy | 360 ± 0.5 °C |
| Pyrolysis Furnace Control Accuracy | 600 ± 0.5 °C |
| Oxidation Furnace Control Accuracy | 600 ± 0.5 °C |
| Programmable Temperature Ramp Cycles | 4 (source rock, reservoir rock, thermal simulation, user-defined) |
| Ramp Linearity Deviation | < 0.5 °C/min |
| Total Analysis Time (Pyrolysis + Organic Carbon) | 14.5 min |
| Interface | USB 2.0 |
| Software Compatibility | Windows 98/2000/XP |
| Compliance | Designed for ASTM D7260, ISO 10303-21 (indirect), and petroleum geochemistry lab workflows aligned with API RP 44 & AAPG guidelines |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | QT-3000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring & Petroleum Geochemistry |
| Temperature Control Range | Ambient +8 °C to 420 °C (0.1 °C increment) |
| Oven Ramp Rate | 0.1–80 °C/min (0.1 °C increment) |
| Cooling Rate | 450 °C → 50 °C in ≤6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (EPC/EFC) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (EPC/EFC) |
| Injector Max Temp | 400 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| FID Detection Limit | ≤2×10⁻¹² g/s (benzene) |
| FID Noise | ≤0.02 mV |
| FID Drift | ≤0.15 mV/h |
| FID Linearity | ≥10⁷ |
| Temperature Stability | ±0.05 °C (≤200 °C), ±0.1 °C (>200 °C) |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-8890 |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 300 °C to 100 °C in ≤3.5 min (at 25 °C ambient) |
| Oven Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 |
| Carrier Gas Flow Range | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Range | 0–970 kPa (7 programmable segments) |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| EPC/EFC Resolution | 0.001 psi (pressure), 0.001 mL/min (flow) |
| Supported Detectors | FID, TCD, ECD, FPD, NPD (up to 4 simultaneously) |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cool-down Time | ≤3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 |
| Injector Max Temp | 450 °C |
| Injector Pressure Range | 0–1000 kPa |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–1000 kPa |
| Detector Options | FID, TCD, ECD, FPD, NPD (up to 4 simultaneously installed) |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| FID Linear Dynamic Range | ≥10⁷ |
| TCD Sensitivity | ≥10,000 mV·mL/mg (benzene) |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cool-down Time | ≤3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Temperature Gradient Uniformity | ±1% (100–350 °C) |
| Programmable Temperature Steps | Up to 99 |
| Maximum Runtime per Method | 9999 min |
| Carrier Gas Flow Range | 0–1200 mL/min (electronic flow control) |
| Carrier Gas Pressure Range | 0–1000 kPa (electronic pressure control) |
| Injector Max Temp | 450 °C |
| Injector Pressure Set Range | 0–1000 kPa |
| Injector Total Flow Set Range | 0–1200 mL/min |
| Detector Options | FID, TCD, ECD, FPD, NPD (modular |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| FID Baseline Noise | ≤2×10⁻¹⁴ A |
| FID Drift | ≤1.5×10⁻¹³ A/30 min |
| FID Linear Range | ≥10⁷ |
| TCD Sensitivity | ≥10,000 mV·mL/mg (benzene) |
| TCD Noise | ≤20 µV |
| TCD Drift | ≤150 µV/30 min |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-9860F |
| Temperature Control Range | Ambient +8°C to 450°C |
| Maximum Ramp Rate | 65°C/min |
| Cooling Rate | 300°C → 100°C in ≤3.5 min (at 25°C ambient) |
| Temperature Stability | ±0.01°C |
| Programmed Temperature Steps | ≥100 |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| FID Linear Dynamic Range | ≥10⁷ |
| FID Operating Temperature | Up to 450°C |
| Detector Configurability | Simultaneous installation of 1–3 modular detectors (FID, TCD, etc.) |
| Inlet Configurations | Up to 3 inlets |
| Inlet Max Temp | 450°C |
| Electronic Pressure/Flow Control | Yes |
| Data System | Integrated IoT-enabled chromatography workstation with remote monitoring, audit trail, and GLP-compliant reporting |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Focus | Petrochemical Industry |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cool-down Time | ≤3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 steps |
| Carrier Gas Flow Range | 0–1200 mL/min (electronically controlled) |
| Carrier Gas Pressure Range | 0–1000 psi (electronically controlled) |
| Detector Options | FID, TCD, ECD, FPD, NPD (up to 4 detectors simultaneously installable) |
| Data System | Integrated IoT-enabled chromatography workstation with remote monitoring, audit trail, and CFR Part 11-compliant reporting modules |
| [Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Max. Ramp Rate | 65 °C/min |
| Cool-down Time | ≤3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Temp. Gradient Uniformity | ±1% (100–350 °C) |
| Programmable Steps | Up to 99 |
| Max. Run Time | 9999 min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Injector Max. Temp. | 450 °C |
| Injector Pressure Setpoint Range | 0–1000 psi |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Simultaneous Detectors | Up to 4 |
| Injector Configurations | Up to 3 injectors |
| Inlet Modes | Split, splitless, on-column, PTV, cool-on-column, direct injection] |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Model | GC-9870 F |
| Price Range | USD 2,800–4,200 (FOB) |
| Operating Temperature Range | Ambient + 5°C to 400°C |
| Oven Ramp Rate | 0.1–50°C/min |
| Oven Cool-down | ~6 min (300°C to 50°C) |
| Carrier Gas Flow Control Range | 0–600 mL/min |
| Carrier Gas Pressure Control Range | 0–0.4 MPa |
| Injector Maximum Temperature | 400°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–600 mL/min |
| Column Installation Span | 152.4 mm (6-inch standard) |
| Dimensions (L×H×W) | 520 × 480 × 500 mm |
| Net Weight | 50 kg |
| Max Power Consumption | 2500 W |
| Voltage | 220 V ±10% |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Oven Temperature Range | 25–450 °C |
| Maximum Ramp Rate | 60 °C/min |
| Cooling Rate | 1 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 kPa |
| Injector Max Operating Temperature | 0–450 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Stability | ±0.02 °C |
| Programmable Temperature Ramps | Up to 20 steps |
| Number of Independent Temperature Zones | 8 |
| FID Sensitivity (n-hexadecane) | ≤1×10⁻¹² g/s |
| FID Baseline Noise | ≤2×10⁻¹⁴ A |
| FID Drift | ≤2×10⁻¹³ A/30 min |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9870Plus |
| Temperature Control Range | 25–450 °C |
| Maximum Ramp Rate | 60 °C/min |
| Cooling Rate | 1 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1000 psi |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Temperature Stability | ±0.02 °C |
| Programmable Temperature Ramps | Up to 20 steps |
| Number of Independent Temperature Zones | 8 |
| FID Sensitivity (n-hexadecane) | ≤1×10⁻¹² g/s |
| FID Baseline Noise | ≤2×10⁻¹⁴ A/30 min |
| FID Drift | ≤2×10⁻¹³ A/30 min |
| TCD Filament Current | Up to 220 mA |
| Supported Detectors | FID, TCD, FPD, ECD, NPD |
| MS Interface | Standard预留 (MS-ready interface) |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 300 °C → 100 °C in ≤3.5 min (at 25 °C ambient) |
| Temperature Accuracy | ±0.01 °C |
| Programmable Temperature Steps | ≥100 |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| FID Linear Dynamic Range | ≥10⁷ |
| FID Operating Temperature | Up to 450 °C |
| Inlet Max Temp | 450 °C |
| Simultaneous Inlets | Up to 3 |
| Available Inlet Types | 6 configurations |
| Simultaneous Detectors | 1–3 (FID/TCD modular options) |
| TCD Dual-Channel Makeup Gas Support | Yes |
| Brand | Huaai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Fluorine-Containing Gas Analysis |
| Temperature Control Range | Ambient +8°C to 399°C |
| Oven Ramp Rate | 1–40°C/min |
| Oven Cool-Down Rate | ~7 min (from 350°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Max Operating Temperature | 399°C |
| Injector Pressure Setpoint Range | 0–0.4 MPa |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Detector | Dual Corrosion-Resistant Thermal Conductivity Detectors (TCD) |
| Sampling | Negative-Pressure Sampling with 316L Stainless Steel Adsorption Vessel and PTFE-Sealed Valves |
| Valve Type | VICI 1/8" Six-Port and Four-Port Switching Valves |
| Software | PC-Based Bidirectional Remote Control with 6 Programmable Event Outputs for Valve/Pump Sequencing |
| Compliance | Designed for GLP-compliant HF gas analysis in semiconductor, fluoropolymer, and specialty gas manufacturing environments |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GC2002 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 5 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 400 °C to 50 °C in ≤4 min (with auto back-door) |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–250 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Control Accuracy/Stability | ≤±0.5 % |
| Temperature Display Resolution | 0.1 °C |
| Programmable Temperature Steps | 8-stage |
| Programmed Ramp Reproducibility | ≤±0.5 % |
| Column Oven Internal Dimensions | 160 × 304 × 278 mm (D × W × H) |
| Mainframe Dimensions | 585 × 650 × 506 mm (L × W × H) |
| Weight | ~53 kg |
| Power Consumption | ~3000 W |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic Laboratory Gas Chromatograph |
| Model | GC2002 (High-End Intelligent Network GC) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient + 5°C to 450°C |
| Maximum Ramp Rate | >120°C/min |
| Cooling Time | <5 min (from 300°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400°C |
| Injector Pressure Set Range | 0–970 kPa |
| Injector Total Flow Set Range | 0–1200 mL/min |
| Temperature Control Precision | ±0.01°C |
| EPC/EFC Pressure Accuracy | 0.001 psi |
| EPC/EFC Flow Accuracy | 0.001 mL/min |
| Programmed Temperature Steps | Up to 16 stages (expandable to unlimited) |
| Retention Time Repeatability (RSD) | <0.008% |
| Peak Area Repeatability (RSD) | <1.0% |
| Detector Options | TCD, FID, ECD, FPD |
| [Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Focus | Petrochemical Industry |
| Oven Temperature Range | Ambient + 3 °C to 450 °C |
| Maximum Ramp Rate | 120 °C/min (0.1 °C/min increment) |
| Cooling Rate | 350 °C → 50 °C in ≤5 min (with motorized rear door) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–100 psi |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–100 psi |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| EPC/EFC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Temperature Stability | ±0.1% of setpoint |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| Detector Options | TCD, FID, ECD, FPD |
| Column Oven Capacity | 305 × 160 × 278 mm (W×D×H) |
| Dimensions (W×D×H) | 570 × 570 × 506 mm |
| Weight | ≤55 kg |
| Power | ≤3000 W, 220 V ±10%, 50 Hz ±5%] |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC9800 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 0–450 °C |
| Maximum Ramp Rate | 0–120 °C/min |
| Cooling Rate | ≤4 min (column oven from 350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Temperature Control Precision | ±0.01 °C |
| EPC/EFC Pressure Accuracy | 0.001 psi |
| EPC/EFC Flow Accuracy | 0.001 mL/min |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| Maximum Programmed Temperature Steps | 16 (expandable to unlimited) |
| Detector Signal Linearity | FID 10⁷, TCD 10⁵, ECD 10⁴, FPD 10⁴ |
| Brand | Shanghai Kechuang |
|---|---|
| Model | GC9800 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | High-Purity Gas Analysis (Food-Grade CO₂, Beverage & Brewing Gases) |
| Oven Temperature Range | Ambient + 8 °C to 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Rate | 400 °C → 50 °C in ≤4 min |
| Carrier Gas Flow Control Range | 0–100 mL/min |
| Carrier Gas Pressure Control Range | 0–250 kPa |
| Injector Max Temp | 300 °C |
| Injector Pressure Setpoint Range | 0–250 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| FID Detection Limit (n-Hexadecane) | ≤8.0×10⁻¹² g/s |
| FID Baseline Noise | ≤1×10⁻¹³ A |
| FID Baseline Drift | ≤7×10⁻¹³ A/30 min |
| FID Linear Dynamic Range | 10⁷ |
| Benzene LOD (v/v) | ≤0.010×10⁻⁶ |
| Total Hydrocarbons LOD | ≤0.2×10⁻⁶ |
| Non-Methane Hydrocarbons LOD | ≤0.1×10⁻⁶ |
| Methane LOD | ≤0.1×10⁻⁶ |
| [Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | GC9800B |
| Detection Modes | TCD, FID, ECD, FPD |
| Temperature Control Range | Ambient +3°C to 450°C |
| Column Oven Programmable Ramp | Up to 16 stages (expandable to unlimited) |
| EPC/EFC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| Dimensions (W×H×D) | 530 × 510 × 535 mm |
| Weight | ≤50 kg |
| Power Supply | 220 V ±10%, 50 Hz ±5%] |
| Brand | ShangHaiYousufu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 12.7 mm OD × 0.89 mm Wall Thickness |
| Tube Material | ASTM A269/A270 Grade 316L Stainless Steel |
| Surface Finish | Bright Annealed (BA) |
| Outer Diameter Tolerance | ±0.02 mm |
| Outer Surface Roughness | Ra ≤ 0.4 µm |
| Compliance Standards | GB/T 12771, ASTM A269, ASTM A270, JIS G3446, DIN 17456 |
| Packaging | Non-woven Fabric Wrapped, Sealed in Plastic Caps |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Brevis GC-2050 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Carrier Gas Pressure Range & Control | 0–1035 kPa (7 programmable pressure segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | G-VAPORIZER |
| Price Range | USD 3,900 – 5,600 (FOB) |
| Instrument Type | Laboratory Gas Chromatograph Accessory |
| Application Field | Petrochemical & Coal Chemical Industries |
| Maximum Operating Temperature | 230 °C |
| Maximum Sample Inlet Pressure | 9 MPa (1305 psi) |
| Heating Zone | Heated Transfer Line with Active Temperature Control |
| Inlet Configuration | Dual-Mode (Gas/Liquid) with Solenoid Valve Integration |
| Communication Interface | GC-System Synchronization via Digital I/O or RS-232 |
| Surface Treatment | Passivated Stainless Steel Tubing |
| Filtration | Integrated Particulate Filter (5 µm) |
| Brand | Shimadzu |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | GC Smart (GC-2018) |
| Application Scope | General-purpose analysis |
| Detector Options | FID, TCD |
| Inlet Options | Packed column inlet, Split/Splitless capillary inlet |
| Maximum Configurable Inlets | 2 |
| Maximum Configurable Detectors | 2 |
| Integrated Autosampler Power Supply | Yes (for AOC-20i) |
| Software | LabSolution LE |
| Connectivity | USB 2.0, Ethernet (10/100BASE-TX) |
| Compliance Support | ASTM D3606, D5504 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Detector Compatibility | FID, TCD, BID (Tracera) |
| Inlet Options | Split/Splitless Capillary, Packed Column |
| Max Inlet Temperature | Not specified |
| Temperature Programming | Programmable oven with ramp/hold capability |
| Carrier Gas Control | Integrated Advanced Flow Monitoring (AFM) and Advanced Pressure Monitoring (APM) |
| Auto-sampler Ready | AOC-20i power integrated |
| Compliance | Designed for GLP/GMP environments |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-14C |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | General-Purpose |
| Temperature Control Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down | 450 °C to 50 °C in ≤6 min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-14C |
| Instrument Type | Laboratory Gas Chromatograph |
| Import Status | Imported |
| Distributor Type | Authorized Reseller |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-17A |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | +4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | −50 °C to 450 °C (with optional LN₂ cooling) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | −400 to +400 kPa/min |
| Temperature Accuracy | ±1% of set Kelvin temperature (with 0.01 °C calibration capability) |
| Temperature Stability | 0.01 °C/°C |
| Programmable Temperature Steps | 5 (including cooling ramps) |
| Split Ratio Digital Control Range | 0–400 |
| FID Detection Limit | 5 pg C/s (n-dodecane) |
| FID Dynamic Range | 10⁷ |
| NPD (FTD) Detection Limits | 0.4 pg N/s (azobenzene), 0.05 pg P/s (tributyl phosphate) |
| NPD Dynamic Range | 10⁴ |