Empowering Scientific Discovery

Gerhardt China

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGerhardt
OriginGermany
ManufacturerC. Gerhardt GmbH & Co. KG
ModelVAPODEST 200
Instrument TypeBenchtop Volatile Phenol Distillation Unit
Water Consumption~5 L/min
Distillation Time2–4 min
Power Rating2200 W
Voltage/Frequency230 V AC, 50/60 Hz
Dimensions (W×D×H)527 × 390 × 697 mm
Weight25 kg
Repeatability±1%
Detection Limit0.1 mg
Recovery Rate≥99.5%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGerhardt
OriginGermany
ManufacturerC. Gerhardt GmbH & Co. KG
ModelVAP 200
Instrument TypeLaboratory Benchtop Distillation Unit
Water Consumption~5 L/min
Distillation Time2–4 min
Power Rating2200 W
Supply Frequency50/60 Hz
Dimensions (W×D×H)527 × 390 × 697 mm
Net Weight25 kg
Repeatability±1%
Detection Limit0.1 mg sulfide
Recovery Rate≥99.5%
Power Supply230 V AC
ComplianceEN ISO 9001 certified manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGerhardt
OriginGermany
ManufacturerC. Gerhardt GmbH & Co. KG
TypeLaboratory Benchtop System
ModelTTs 4 CAR
Heating Positions4
Distillation Flask Capacity800 mL
Max Heating Temperature650 °C
Programmable Methods99
Magnetic StirringIntegrated
Rated Power2000 W
Order No.12-06144
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC. Gerhardt
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelCSB 8s
Digestion MethodReflux Digestion
Heating ModuleSingle Aluminum Block
Batch Capacity8 samples
Temperature Range0–430 °C
Temperature Accuracy±0.5 °C
Digestion Vessel Volume300 mL
Timer Resolution0.0001 h (0.36 s)
Programmable Methods99 user-defined methods (up to 40 heating steps per method)
Preloaded Methods30 standard protocols
Power ControlContinuously adjustable heating power
ControllerDetachable, password-protected unit with audit trail and user access levels
Footprint51.5 × 48.3 cm
Safety FeaturesMotorized lift mechanism for sample rack, preheating function, thermal insulation, overtemperature protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGerhardt
OriginGermany
ManufacturerC. Gerhardt GmbH & Co. KG
TypeLaboratory Benchtop Distillation Unit
PrincipleSteam Distillation Coupled with Electrode-Based Ammonia Detection
Range0.1–200 mg NH₃-N per sample
Accuracy±1% of reading
LOD0.1 mg NH₃-N
Cycle Time2–4 min per sample
Throughput1 sample per run
ComplianceISO 17025-ready, GLP/GMP-compatible architecture, FDA 21 CFR Part 11–enabled data integrity features
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGerhardt
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginImported
ModelVAPODEST 200 A
Instrument TypeLaboratory Benchtop Distillation System
Water Consumption~5 L/min
Distillation Time2–4 min
Power Rating2200 W
Frequency50/60 Hz
Weight25 kg
Dimensions (W×D×H)527 × 390 × 697 mm
Repeatability±1%
Detection Limit0.1 mg
Supply Voltage230 V AC
Recovery Rate≥99.5%
Quality CertificationCompliant with EN ISO 9001 throughout design, production, and shipment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC. Gerhardt
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelCSB-L 20s
Digestion MethodReflux Digestion
Heating ModuleSingle Aluminum Block
Batch Capacity20 samples
Temperature Range0–430 °C
Temperature Accuracy±0.5 °C
Digestion Vessel Capacity300 mL
Timer Accuracy±0.00 min
Show next