- All
- Favorite
- Popular
- Most rated
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Product Type | Imported |
| Model | KT-L 40s |
| Instrument Category | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 40 |
| Max. Heating Temperature | 430 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Principle | Aluminum Block with Drilled Wells |
| Reagent Channels | 8–40 |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | EV 16 |
| Heating Power | 2700 W |
| Max. Operating Temperature | 450 °C |
| Temperature Uniformity | ±1 °C across Heating Zone |
| Heating Surface Diameter | 85 mm |
| Overall Dimensions (W × D × H) | 900 × 225 × 110 mm |
| Weight | 10 kg |
| Voltage | 230 V AC |
| Frequency | 50/60 Hz |
| Number of Heating Positions | 6 |
| Heating Technology | Infrared Radiant Heating |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 300 °C |
| Extraction Cell Volume | 100 mL or 150 mL |
| Extraction Time | 0–120 min |
| Dimensions (W×D×H) | 525 × 410 × 580 mm (SOX 416 Macro) |
| Sample Capacity | 2, 4, 6, or up to 24 positions (via modular configuration) |
| Power Supply | 230 VAC, 50/60 Hz |
| Power Consumption | 1200 W |
| Weight | 42 kg |
| Cooling Water Flow | 0.5–3.5 L/min, min. pressure 0.3 bar |
| Communication Interface | Dual RS-485 ports |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | VAPODEST 200 |
| Instrument Type | Benchtop Volatile Phenol Distillation Unit |
| Water Consumption | ~5 L/min |
| Distillation Time | 2–4 min |
| Power Rating | 2200 W |
| Voltage/Frequency | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 527 × 390 × 697 mm |
| Weight | 25 kg |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg |
| Recovery Rate | ≥99.5% |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | VS |
| Application | Laboratory Acid Fume Treatment |
| Principle | Dilution, Chemical Neutralization, Absorption |
| Flow Rate | 120 L/min |
| Compliance | Meets German TRGS 554 and EU Directive 2010/32/EU for laboratory fume control |
| Power Consumption | 100 W |
| Noise Level | <52 dB(A) |
| Maintenance | Tool-free access via top-hinged door |
| Cooling | Integrated condensate trap |
| Filtration | Dual-stage — chemical scrubbing + optional solid-phase adsorption cartridge |
| Compatibility | Fully interoperable with Gerhardt KJELDATHERM, TURBOTHERM, KI digestion units and SMA series reflux digesters |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | Vap300 |
| Principle | Kjeldahl Distillation (Steam Distillation) |
| Measurement Range | 0.01–100 mg N |
| Repeatability | ±1% |
| Detection Limit | 0.01 mg N |
| Recovery Rate | >99.5% |
| Power Supply | 230 V AC, 50/60 Hz |
| Power Consumption | 2200 W |
| Dimensions (W×D×H) | 440 × 340 × 690 mm |
| Weight | 34 kg |
| Cooling Water Requirement | 2–5 L/min |
| Sample Distillation Time | 2–4 min per sample |
| Steam Output Control | 10–100% programmable via software |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | KI 1 |
| Maximum Temperature | 600 °C |
| Heating Zone | Single |
| Flask Capacity Range | 50–250 mL |
| Dimensions (W×D×H) | 150 × 225 × 130 mm |
| Weight | 2 kg |
| Voltage | 230 V AC |
| Frequency | 50/60 Hz |
| Power Rating | 450 W |
| Ordering Code | 10-0003 |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Imported Instrument |
| Model | VAPODEST 200 |
| Power | 2200 W |
| Supply Voltage | 220 V AC, 50/60 Hz |
| Water Consumption | ~5 L/min |
| Distillation Time (for N-nitrosamines) | 6–10 min |
| Dimensions (W×D×H) | 527 × 390 × 697 mm |
| Weight | 25 kg |
| Compliance | Fully compliant with GB 5009.26–2023 |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0.003 mg – 50 mg N |
| Sample Weight | 0.5 mg – 1 g |
| Digestion/Combustion Time | 3–5 min per sample |
| Repeatability | < 0.5% RSD |
| Recovery Rate | > 99.5% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 370 mm × 800 mm × 500 mm |
| Carrier Gas Options | Helium (high sensitivity) or Argon (cost-optimized) |
| Sample Forms | Solid, liquid, paste |
| Optional Autosampler | 64-, 100-, or 144-position pneumatic autosampler |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | VAP 200 |
| Instrument Type | Laboratory Benchtop Distillation Unit |
| Water Consumption | ~5 L/min |
| Distillation Time | 2–4 min |
| Power Rating | 2200 W |
| Supply Frequency | 50/60 Hz |
| Dimensions (W×D×H) | 527 × 390 × 697 mm |
| Net Weight | 25 kg |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg sulfide |
| Recovery Rate | ≥99.5% |
| Power Supply | 230 V AC |
| Compliance | EN ISO 9001 certified manufacturing |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | VAPODEST 550C |
| Price | USD 92,000 (approx.) |
| Distillation Time | 12 min per sample |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Electric Heating Digestion Instrument |
| Automation Level | Semi-Automatic |
| Digestion Positions | 8 / 20 / 40 |
| Max. Heating Temperature | 430 °C |
| Temperature Control Accuracy | ±0.5% |
| Heating Principle | Aluminum Block Heating |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–200 mg N per sample |
| Steam Distillation Time | 3.5 min/sample |
| Repeatability | ±1% RSD |
| Sample Weight Capacity | ≤5 g (solid) |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Laboratory Benchtop System |
| Model | TTs 4 CAR |
| Heating Positions | 4 |
| Distillation Flask Capacity | 800 mL |
| Max Heating Temperature | 650 °C |
| Programmable Methods | 99 |
| Magnetic Stirring | Integrated |
| Rated Power | 2000 W |
| Order No. | 12-06144 |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Kjeldahl Nitrogen Determinator |
| Model | VAPODEST® 200 |
| Automation Level | Semi-Automatic |
| Nitrogen Range | 0.1–200 mg |
| Distillation Time | 2–4 min per sample |
| Repeatability | ±1% |
| Sample Weight (solid) | ≤5 g |
| Recovery Rate | 99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 mm × 390 mm × 697 mm |
| Compatible Acid Titration Range | Universal (any standard acid concentration) |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | VAPODEST 400 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic Steam Distillation System |
| Nitrogen Determination Range | 0.1–200 mg N |
| Distillation Time per Sample | 2–4 min |
| Repeatability | ±1% RSD |
| Sample Weight Capacity (Solid) | ≤5 g |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 mm × 390 mm × 697 mm |
| Cooling Water Flow Requirement | 5–7 L/min |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automatic |
| Repeatability | RSD < 0.5% |
| Sample Weight Capacity | up to 1 g |
| Nitrogen Recovery Rate | ≥ 99.5% |
| Power Consumption | 1400 W |
| Dimensions (L × W × H) | 600 × 550 × 722 mm |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | KI 11/26 |
| Max Temperature | 650 °C |
| Number of Heating Positions | 6 |
| Flask Capacity | 500 mL (standard), 750 mL (expanded neck) |
| Voltage | 400 V, 3P+N |
| Frequency | 50–60 Hz |
| Power Consumption | 3480 W |
| Dimensions (L×W×H) | 900 × 250 × 300 mm |
| Net Weight | 15 kg |
| Exhaust Configuration | Centralized waste gas duct with minimized overflow |
| Digestion Time (Typical) | ~2 h |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | VAP 550 |
| Detection Limit | 0.1234 mg/L |
| Measurement Range | 0.1234–500 mg/L |
| Instrument Class | Intelligent, Fully Automated Distillation-Titration System |
| Compliance | ISO 9001, ISO/IEC 17025, GLP, FDA 21 CFR Part 11 (via GERHARDT MasterControl Software) |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Imported |
| Model | TTs125 |
| Max Temperature | 650 °C |
| Heating Element | Special Infrared Alloy |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | SMA 8s |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 8 |
| Max Heating Temperature | 240 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Principle | Electrical Resistance Heating |
| Reagent Dispensing Channels | 0 (No reagent addition) |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | VAP450 |
| Instrument Type | Quartz Glass Distillation Apparatus |
| Heating Method | Electric |
| Cooling Method | External Circulating Chiller or Tap Water |
| Distillation Rate | 30 samples/hour |
| Heating Position | 1-place |
| Power Consumption | 2200 W |
| Voltage/Frequency | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 527 × 390 × 697 mm |
| Weight | 34 kg |
| Water Consumption | ~3 L/min |
| Typical Distillation Time | 3 min 30 s |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg |
| Recovery Rate | >99.5% |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Range | 0.1–200 mg N |
| Distillation Time | 2–4 min per sample |
| Repeatability | ±1% RSD |
| Sample Mass | 1 g |
| Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Linear Range | 0.1–200 mg N |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | CSB 8s |
| Digestion Method | Reflux Digestion |
| Heating Module | Single Aluminum Block |
| Batch Capacity | 8 samples |
| Temperature Range | 0–430 °C |
| Temperature Accuracy | ±0.5 °C |
| Digestion Vessel Volume | 300 mL |
| Timer Resolution | 0.0001 h (0.36 s) |
| Programmable Methods | 99 user-defined methods (up to 40 heating steps per method) |
| Preloaded Methods | 30 standard protocols |
| Power Control | Continuously adjustable heating power |
| Controller | Detachable, password-protected unit with audit trail and user access levels |
| Footprint | 51.5 × 48.3 cm |
| Safety Features | Motorized lift mechanism for sample rack, preheating function, thermal insulation, overtemperature protection |
Show next