Empowering Scientific Discovery

Gerhardt China

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGerhardt
OriginGermany
ManufacturerC. Gerhardt GmbH & Co. KG
Instrument TypeDumas Combustion Method
Automation LevelFully Automated Nitrogen Determinator
Nitrogen Range0.003 mg – 50 mg N
Sample Weight0.5 mg – 1 g
Digestion/Combustion Time3–5 min per sample
Repeatability< 0.5% RSD
Recovery Rate> 99.5%
Power Consumption2000 W
Dimensions (L×W×H)370 mm × 800 mm × 500 mm
Carrier Gas OptionsHelium (high sensitivity) or Argon (cost-optimized)
Sample FormsSolid, liquid, paste
Optional Autosampler64-, 100-, or 144-position pneumatic autosampler
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGerhardt
OriginGermany
ManufacturerC. Gerhardt GmbH & Co. KG
Instrument TypeKjeldahl Nitrogen Determinator
Automation LevelFully Automated
Nitrogen Determination Range0.1–200 mg N per sample
Steam Distillation Time3.5 min/sample
Repeatability±1% RSD
Sample Weight Capacity≤5 g (solid)
Nitrogen Recovery Rate>99.5%
Power Consumption2200 W
Dimensions (L×W×H)527 × 390 × 697 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC. Gerhardt
OriginGermany
ManufacturerC. Gerhardt GmbH & Co. KG
TypeKjeldahl Nitrogen Determinator
ModelVAPODEST® 200
Automation LevelSemi-Automatic
Nitrogen Range0.1–200 mg
Distillation Time2–4 min per sample
Repeatability±1%
Sample Weight (solid)≤5 g
Recovery Rate99.5%
Power Consumption2200 W
Dimensions (L×W×H)527 mm × 390 mm × 697 mm
Compatible Acid Titration RangeUniversal (any standard acid concentration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGerhardt
OriginGermany
ManufacturerC. Gerhardt GmbH & Co. KG
ModelVAPODEST 400
Instrument TypeKjeldahl Nitrogen Determinator
Automation LevelSemi-Automatic Steam Distillation System
Nitrogen Determination Range0.1–200 mg N
Distillation Time per Sample2–4 min
Repeatability±1% RSD
Sample Weight Capacity (Solid)≤5 g
Nitrogen Recovery Rate≥99.5%
Power Consumption2200 W
Dimensions (L×W×H)527 mm × 390 mm × 697 mm
Cooling Water Flow Requirement5–7 L/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGerhardt
OriginGermany
ManufacturerC. Gerhardt GmbH & Co. KG
Instrument TypeDumas Combustion Method
Automation LevelFully Automatic
RepeatabilityRSD < 0.5%
Sample Weight Capacityup to 1 g
Nitrogen Recovery Rate≥ 99.5%
Power Consumption1400 W
Dimensions (L × W × H)600 × 550 × 722 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC. Gerhardt
OriginGermany
ManufacturerC. Gerhardt GmbH & Co. KG
Instrument TypeKjeldahl Nitrogen Determinator
Automation LevelFully Automated
Nitrogen Range0.1–200 mg N
Distillation Time2–4 min per sample
Repeatability±1% RSD
Sample Mass1 g
Recovery Rate>99.5%
Power Consumption2200 W
Dimensions (L×W×H)527 × 390 × 697 mm
Linear Range0.1–200 mg N
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGerhardt
OriginGermany
ManufacturerC. Gerhardt GmbH & Co. KG
TypeVAP500C
Instrument CategoryKjeldahl Nitrogen Determinator
Automation LevelFully Automated
Nitrogen Detection Range0.1 mg N (absolute)
Distillation Time2–4 min per sample
Repeatability±1% RSD
Sample Weight Capacity10–160 g
Nitrogen Recovery Rate>99.5%
Power Consumption2300 W
Dimensions (L×W×H)960 mm × 600 mm × 1670 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGerhardt
OriginGermany
ManufacturerC. Gerhardt GmbH & Co. KG
Instrument TypeKjeldahl Nitrogen Determinator
Automation LevelSemi-Automatic
Nitrogen Determination Range0.1–200 mg
Distillation Time3.5 min
Repeatability±1%
Sample Weight Capacity≤5 g (solid)
Nitrogen Recovery Rate≥99.5%
Power Consumption2200 W
Dimensions (L×W×H)527 mm × 390 mm × 697 mm
Linearity Range0.1–200 mg N
Water Consumption~3 L/min
Operating Voltage/Frequency230 V AC, 50/60 Hz
Net Weight34 kg
Show next