Empowering Scientific Discovery

Guangzhou Yitongxing Instrumentation & Metering Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ModelBeNano 90 Zeta
Particle Size Range (DLS)0.3 nm – 15 μm
Zeta Potential RangeNo Practical Limitation
Electrophoretic Mobility Range> ±20 μm·cm/V·s
Conductivity RangeUp to 260 mS/cm
pH Range2–12 (compatible with aqueous & low-ionic-strength media)
Temperature Control Range−10 °C to +110 °C
Temperature Accuracy±0.1 °C
Sample Volume (DLS mode)3 µL (capillary cell) / 0.75 mL (standard cuvette)
Detection Angles90° (size), 12° (zeta)
Laser Source50 mW solid-state laser, 671 nm
DetectorAPD (Avalanche Photodiode)
Correlator4000-channel digital correlator, 10¹¹ dynamic linear range
Optical Path StabilityPassive thermal stabilization, no daily alignment required
Data OutputHydrodynamic diameter (Dₕ), polydispersity index (PDI), zeta potential distribution, electrophoretic mobility, diffusion coefficient (D), intensity/volume/number-weighted size distributions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
ModelBT312
OriginLiaoning, China
ComplianceGB/T 21354–2008, ISO 3953:1993, USP <616>, ChP 2020 Edition (General Chapter 0991)
Vibration ModeVertical tapping + patented horizontal rotation
Sample StationsDual-position
ReportingIntegrated thermal printer
Application ScopeNon-metallic & metallic powders, pharmaceuticals, battery materials, abrasives, catalysts, R&D and QC laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelBetterSize2600
Price RangeUSD 21,000 – 28,000 (FOB)
Dispersion MethodDry & Wet Dispersal
Instrument TypeLaboratory Laser Diffraction Particle Size Analyzer
Measurement Range0.02–2600 µm (wet), 0.1–2600 µm (dry)
Repeatability≤ 0.5% (D50, certified reference material, wet mode)
Measurement Time≤ 10 s per analysis
Optical ConfigurationDual-orientation Fourier optical system with inclined sample cell
Detection Angle Range0.016°–165°
Number of Photodetectors92 (72 forward, 14 side, 6 backward)
Laser SourceHigh-power polarized fiber laser
AlignmentFully automated optical alignment
Software InterfaceSOP-driven automation
Operating SystemsWindows XP/7/8/10
ConnectivityUSB 2.0 or 3.0
Ultrasonic Power50 W
Circulation Tank Volume600 mL
Flow Rate (Wet)3000–8000 mL/min
Gas Pressure (Dry)0.1–0.8 MPa (adjustable)
Gas Flow Rate (Dry)400–6000 L/min
Sample Mass0.2–10 g
Resolution (Bimodal Separation)≥1.65 (ratio of nominal D50 values)
Accuracy≤ 0.5% (D50, NIST-traceable standard, wet mode)
ComplianceMeets ISO 13320:2020, ASTM E799-22, and GB/T 19077–2016 requirements for laser diffraction particle sizing