Empowering Scientific Discovery

Guangzhou Yitongxing Instrumentation & Metering Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX220
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionAutomatic Deuterium Lamp Background Correction
Spectral Resolution0.2 nm
Sensitivity≤0.03 µg/mL for Cu (Flame), ≤0.4 pg for Cd (Graphite Furnace)
Relative Standard Deviation (RSD)≤0.5%
Detection Limit≤0.003 µg/mL for Cu (Flame), ≤0.4 pg for Cd (Graphite Furnace)
Baseline Stability≤0.003 µg/mL (Flame Cu), ≤0.4 pg (Graphite Furnace Cd)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKETT
OriginJapan
ModelPB-1D3
Measurement PrincipleElectrical Resistance
Sample TypesPaddy Rice, Brown Rice, Milled Rice, Barley, Wheat, Rye
Moisture RangePaddy Rice: 11–35%
Brown/Milled Rice11–20%
Barley/Wheat10–40%
Rye10–20%
Accuracy±0.1% (at ≤20%), ±0.5% vs. 105°C Oven-Drying Reference Method
Display128×64 Dot-Matrix LCD, Resolution: 0.1%
Temperature CompensationAutomatic Thermistor-Based Correction
Power SupplyAC 100 V (50/60 Hz) or Four 1.5 V AA Batteries
Dimensions & Weight250 × 240 × 125 mm, 3.5 kg
AccessoriesSample Pan, 15% Calibration Standard, Measuring Spoon, Hand Grinder Handle, Cleaning Brush, Power Cord, Instruction Manual
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelMAS-100
Detection PrinciplePurge-and-Trap GC-Cold Vapor Atomic Fluorescence Detection (GC-AFD)
ComplianceHJ 977–2018
Detector TypeIntegrated Miniaturized Cold Vapor Atomic Fluorescence Detector (AFD)
Column CompatibilityCapillary GC columns
Auxiliary Detectors SupportedFID, ECD, TCD, FPD, TSD
Mercury SpeciationMethylmercury, Ethylmercury
Sample MatrixAqueous solutions
Derivatization ReagentSodium Tetrapropylborate (NaBPr₄)
Trapping MediumTenax® sorbent tube
Carrier GasArgon
Post-Detector Mercury CaptureGold-coated Wire Trap with Active Vacuum Pump
Optical DesignMulti-stage stray-light suppression fluorescence cell
High-Temperature Module950 °C pyrolysis with nano-scale thermal insulation
Footprint<120 mm × 100 mm × 80 mm (AFD unit only)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (PRC)
ModelUV-2600i
Optical SystemSingle Monochromator
Detector TypePhotodiode Array (PDA)
Wavelength Range185–1400 nm
Wavelength Accuracy±0.1 nm
Wavelength Repeatability±0.1 nm
Spectral Bandwidth0.1–5.0 nm (variable)
Stray Light< 0.00002% T (at 220 nm and 340 nm)
Automation LevelMotorized Wavelength Scanning
Standard SoftwareLabSolutions UV-Vis
Hardware Validation ModuleIncluded
Dimensions (W × D × H)450 × 540 × 260 mm
Power ConsumptionReduced by 10% vs. previous Shimadzu UV models
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKETT
OriginJapan
ModelPM650
Measurement PrincipleHigh-Frequency Capacitance (50 MHz)
Sample TypeCereals & Seeds
Moisture Range1–40% w/w (varies by grain species)
Sample Volume240 mL
Operating Temperature0–40 °C
Moisture Accuracy±0.5% (vs. ASTM D4940 or ISO 712 dry-weight reference method, for samples ≤20% moisture)
Built-in CompensationAutomatic mass correction via integrated precision balance (0.01 g resolution), temperature compensation via thermistor
Calibration Offset Range−9.9 to +9.9 units (user-adjustable)
Additional OutputsBulk Density (g/L), arithmetic mean of up to 9 readings
DisplayLCD numeric readout
PowerFour 1.5 V AA alkaline batteries
Dimensions (W×D×H)125 × 205 × 215 mm
Weight1.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWQF-530
Instrument TypeLaboratory FTIR Spectrometer
Wavenumber Range350–7800 cm⁻¹
Spectral Resolution< 0.85 cm⁻¹
Signal-to-Noise Ratio (S/N)> 20,000:1 (at 2100–2200 cm⁻¹, 100% line)
Wavenumber Accuracy< 0.85 cm⁻¹
DetectorDLATGS (Deuterated Triglycine Sulfate) with Temperature Stabilization
Scan SpeedMicroprocessor-controlled, adjustable
Data InterfaceEthernet (RJ-45), USB 2.0
SoftwareMainFTOS Suite v3.x
Regulatory Compliance21 CFR Part 11 compliant (audit trail, electronic signature, user access control), GLP/GMP-ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelMOC120H
Measurement PrincipleGravimetric Loss-on-Drying (Infrared Heating)
Sample Capacity0.5–120 g
Moisture Resolution0.01% or 0.1% (selectable)
Mass Resolution0.001 g
Moisture Range0–100% (w/w), 0–500% (dry basis)
Repeatability±0.02% (≥10 g sample)
Temperature Range30–180 °C (1 °C increments)
Heating SourceMedium-Wave Infrared Lamp (625 W max)
Power SupplyAC 100–240 V, 50/60 Hz
Dimensions220 × 415 × 190 mm (W×D×H)
Weight4.5 kg
Data Storage100 measurement records
Method Storage10 user-defined protocols
InterfaceRS-232C, Windows Direct Pass-through
Operating Environment5–40 °C, ≤85% RH
Sample PanStainless Steel (Ø130 mm × 13 mm depth)
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelMOC63U
Maximum Sample Capacity60 g
Minimum Sample Weight0.02 g
Minimum Display Resolution0.001 g / 0.01% or 0.1% (selectable)
Repeatability±0.15% (2 g sample), ±0.05% (5 g sample), ±0.02% (10 g sample)
Heating SourceHalogen Lamp
Heating Power400 W
Temperature Setting Range50–200 °C (1 °C increments)
DisplayBacklit LCD
Pan Diameter95 mm
Dimensions (W × D × H)202 × 336 × 157 mm
Weight4 kg
Operating Environment5–40 °C, ≤85% RH
Measurement ModesStandard, Rapid Dry, Slow Dry, Step Dry
Measurement Duration1–120 min (extendable up to 12 h)
InterfacesRS-232C (9-pin), DATA I/O, USB
Predefined Method Storage10 methods
Data Storage Capacity100 results
Optional AccessoriesTemperature calibration kit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginGuangdong, China
ModelUV1801
Optical SystemSingle-beam
DetectorPhotodiode Array
Wavelength Range190–1100 nm
Wavelength Accuracy±0.5 nm
Wavelength Repeatability±0.5 nm
Spectral Bandwidth1.0, 2.0, or 5.0 nm (user-selectable)
Stray Light≤0.05% T (at 220 nm with NaI solution
Display6-inch high-brightness blue LCD
Light SourcesImported deuterium lamp and tungsten-halogen lamp
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Power Consumption140 W
Dimensions (W×D×H)530 × 420 × 205 mm
Net Weight18 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKETT
OriginJapan
ModelPQ520
Measurement PrincipleCapacitance (with resistive correction)
Sample TypesPolished rice, brown rice, paddy rice, barley, wheat, rye kernels
Moisture RangePolished/brown rice: 11–20% w.b.
Paddy rice11–35% w.b.
Barley/wheat10–40% w.b.
Rye kernels10–35% w.b.
Accuracy±0.5% (for samples ≤20% moisture, w.b.)
Measurement Time<40 seconds per 100 grains (brown rice, average moisture display)
Temperature CompensationIntegrated thermistor-based automatic ambient temperature correction
Grain Count Setting10–1000 grains (user-selectable)
DisplayFluorescent segment display
Output InterfacesRS-232C (printer), USB (PC data export)
Operating Environment5–40°C, ≤85% RH
Power SupplyAC 100 V, 50/60 Hz
Dimensions & Weight320 × 254 × 382 mm (W×D×H), 9.0 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNittoseiko Analytech
OriginJapan
ModelCA-310
Measurement PrincipleCoulometric Karl Fischer Titration
Detection Range5 µg – 999.9999 mg H₂O
Sensitivity0.1 µg H₂O
Accuracy±3 µg (for 10–1000 µg H₂O)
RSD<0.3% (for >1 mg H₂O)
Electrolysis Current430 mA (516 mA in High-Speed Mode)
Titration Speed2.2 mg H₂O/min (36 µg H₂O/sec)
Display8.4-inch color LCD touchscreen
Max Channels4 (optional)
Data IntegrityGLP/GMP-compliant
Interface4× USB, 1× LAN
Operating Temperature15–40 °C
Humidity Limit≤85% RH (non-condensing)
Power SupplyAC 100–120 V / 80 VA or AC 230–240 V / 310 VA, 50/60 Hz
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0